USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Similar documents
USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Cabling Specifications

MACTek Corporation. USB HART Interface. Users Manual

Advantium 2 Plus Alarm

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Sip/Puff Switch User Guide

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

Single Station Remote Alarm

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Balun Bulletin- CCTV Systems- Termination

TTL to RS232 Adapter User Guide

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

T-Extender E-Extender

Zetron Desktop Microphone Manual F

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

CIC-50. T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems)

HDTV. Amplified Indoor Outdoor Antenna. indoor outdoor. 10 db Amplification. Paintable. Versatile TERRESTRIAL VHF UHF

LDG DTS-4/4R Desktop Coaxial Switch / Remote

F2400 FOM II Series Fiber Optic Modem Technical Manual

Wireless Base Station Single and Multiple Headsets

USER MANUAL. MODEL 1082/F idsl Modem with G.703 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

Boca s Family of Ethernet Products

Contents. Safety Warnings... 1

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

USB to RS-422/485 Serial Adapter

VPCCCare. Virtual PC Center Service Warranty Program

PagePac PAGEPAL V

Triple Expansion Chassis

MDC Series

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Cable Specifications. T3 Trunk Cabling APPENDIX

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

User's Guide. Integrating Sound Level Datalogger. Model Introduction

AS-801 Promotion-On- Hold Segregator. Version 2.10

Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Cable Pinouts. SRP I/O Module

24-Port Channelized E1/T1 Line Card Overview

Installation & User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Crestron C2N-ANLZ Cresnet Analyzer Operations Guide

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

About this Manual. Support for Your Product

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

16-Port and 24-Port 10/100 Switches

CABLE MODEM QUICK START

Coax Mapping Tester User's Guide.

I NTERFACE CABLE ADAPTER MODULE

Powerware Relay-Serial Card User s Guide

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Nest Learning Thermostat Installation Guide. Installation step-by-step

Directory chapter 04

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

ROTOR LOADER OWNER S MANUAL

Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide

Model SRMD Setra Remote Monitoring Display

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FriendlyNet PC Card for PowerBook computers

Sunny Boy Accessories SMA POWER BALANCER

2-Pair HDSL1 Adtran Fiber Optic Link System

User's Guide Integrating Sound Level Datalogger Model

PS 155 WIRELESS INTERCOM USER MANUAL

USB Rover port USB m Cat 5 Extender. User Guide

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

MS900AC-B-LS User Information

Telebyte 209 Short Haul Modem

User Manual PT-E-HIP

MTV-FS1 / FS1T / FSB375

How To Size A Stenner Pump

Stretch DisplayPort TM

System Wiring Design Guide

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Terayon DOCSIS Modem Installation. Guide

Hi5. HD-SDI/SDI To HDMI Video and Audio Converter User Manual. December 17, 2008 P/N For Hi5 Serial Number or Later

DDP-3 Engineering Guide

Instructions & Safety Information Models A220-20D and A220-20L Version 2

FOM-5A, 6A. Asynchronous Fiber Optic Modem

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :


Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

2x1 DisplayPort KVM. EXT-DPKVM-241 User Manual.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

UniStream CPU-for-Panel

Transcription:

USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

WARRANTY Patton Electronics warrants all Model 460 components to be free from defects, and will at our option repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. SERVICE AND SUPPORT All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at (301) 975-1007; http://www.patton.com: or, support@patton.com. NOTE: Packages received without an RMA number will not be accepted. Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 460. Technical Service hours: 8AM to 5PM EST, Monday through Friday. output by them are scaled to match the pulse shape requirements specified by the CCITT G.703 standard. The Model 460s come in the following versions (see below): 460 A shielded RJ-45 jack. 460M:Two male coaxial connectors (i.e., center conductor is a pin). 460F:Two female coaxial connectors (i.e., center conductor is a receptacle). 460-TBP A 4-position terminal block. 460M-TBP:Two male coaxial connectors (i.e., center conductor is a pin). 460F-TBP:Two female coaxial connectors (i.e., center conductor is a receptacle). 460MC Two male coaxial connectors at the end of a coax pigtail cable. (i.e., center conductor is a pin).see photo on front cover of manual. Terminal block connector CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive of the European Union (EU). A Certificate of Compliance is available by contacting Patton Technical Support. Model 460-TBP PRODUCT DESCRIPTION The Patton Model 460 Series allow 75 Ohm coax hardware to communicate with 120 Ohm twisted pair equipment. The Model 460 Series specifically address the ONP requirement that European PTTs offer 120 Ohm twisted pair terminations to their customers. Some PTTs and private carriers are standardized on 75 Ohm coax, or have customers whose CPE has only 75 Ohm coax connections. The Model 460 Series present a ready solution to this termination mismatch by allowing a bi-directional conversion of coax (75 Ohm) to a twisted pair (120 Ohm ), supporting data rates to E1 (2.048 Mbps). The signals 1 Model 460 S/N:9912130035 Lot: 00784 RJ-45 connector Model 460 2 connector

RJ-45 Jack and Terminal Block Descriptions Shielded RJ-45 Jack: Pins 1 and 2 are the balanced inputs. The balanced signals are converted to an unbalanced signal on the center conductor of the coax connector. The unbalanced signal from the coax connector is converted to balanced signals on pins of the RJ-45. The shield of the connector may be connected to RJ- 45 pin 6 by jumper JP2 (on). The shield of the connector is always connected to the shield around the RJ-45 connector. This connection may also be connected to RJ-45 pin 3 via JP1 (on). Terminal Block: Has a 4 pin terminal block for a twisted pair connection. The 460M has male coaxial connectors (i.e., center conductor is a pin) and the 460F has female coaxial connectors (i.e., center conductor is a receptacle). connector RJ-45 connector Twisted Twistedpair Pair Equipment CPE Pair 1 TX Shield RX Shield Pair 2 XMT 1 2 3 4 5 6 7 8 Shielded RJ-45 Jack Network JP1 Network GND Signal Signal GND CONFIGURATION NOTE: The Model 460-TBP does not require configuration; go to section INSTALLATION on page 2. The following section describes configuring the Model 460. The Model 460 Series are pre-set to work in most applications without additional configuration. The only parameter that is user-configurable is the shield connection between the 75 Ohm coax and 120 Ohm interfaces. The diagram on the following page shows how the shield is connected between the modular jack and dual BNCs. Removing the jumper breaks the connection. The Model 460 is most often used to bi-directionaly convert CPE twisted pair terminations to CPE coaxial terminations. RJ-45 (120 ohm) Jumper Coax BNC (75 ohm) Pin 3 (TX Shield)... JP1... Shield Pin 6 (RX Shield)...JP2... Shield The factory setting leaves both jumpers JP1 and JP2 (see figure above) in place, thus passing both shield connections through. To break one or both of the shield connections, follow the instructions on the next page. 1) Insert a flat blade screwdriver into the slot on the side of the Model 460 case and twist. The case will pop open, exposing the PC board. 2) Holding the PC board with the modular jack facing left, locate jumper JP1 toward the top of the board and JP2 toward the bottom of the board. Remove the desired jumper(s) to break one or both shield connections. NOTE: Do not lose the jumper(s). 3) Re-align the case halves and end inserts and snap the case halves back together. JP2 3 4

INSTALLATION The sections on the next page describe installing the following: Model 460 Model 460-TBP Refer to the appropriate section on the following page to install your unit. Equipment CPE Terminal block Clamp screws (4 places) Installing the Model 460 Do the following: 1) Refer to the pin configuration below when assembling the cable that will connect to the RJ-45 jack. RJ-45 Pin(s) Function 1 and 2...TX pair 3...TX shield 4 and 5...RX pair 6...RX shield 2) Plug the modular cable connector into the RJ-45 jack. 3) Connect the coaxial cables to the and connectors. Congratulations, you have finished installing the Model 460! Coax Equipment CPE Pair 1 Twisted XMT Pair Twisted-pair EquipmentCPE XMT Pair 2 PATTON MODEL 460 SERIES SPECIFICATIONS Transmission Line: ITU/CCITT G.703 (unstructured) Installing the Model 460-TBP Do the following: 1) Strip the outer jacket insulation from the twisted pairs about 1 inch. 2) Strip back the insulation on each of the wires about.25 inches. 3) Connect one pair of wires to the two XMT (transmit) positions on the terminal block. The Model 460-TBP is not polarity sensitive so either wire may connect to either pole. See figure at upper right. 4) Connect the other pair of wires to the two (receive) positions on the terminal block. 5) Connect the coaxial cables to the and connectors. Data Rate: Unbalanced Coaxial Connection: Balanced Twisted Pair Connection: Power Supply: 2.048 Mbps maximum Dual coax BNC connectors, male or female (RG 59 or 2002 coax) and Nominal Line Impedance = 75 Ohms Single 8-pin RJ-45 jack, shielded (two twisted-pair), Nominal Line Impedance = 120 Ohms and 4-position, removable terminal block None required, passive device Operating Temperature: 0-50 Celcius (32-122 Fahrenheit) 5 Coaxial Twisted Pair Isolation: Compliance: Dimensions: 1500V rms CE approved 0.8H x 1.7W x 2.7D in. (6.86H x 4.32W x 2.03D cm.) 6