Quick Installation and Setup for WinPower Software



Similar documents
Quick Installation and Setup for WinPower Software

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

EOS REBEL XS / 1000D Firmware Update Procedures Precaution

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Using the UPSMON-Plus Monitoring Software

Maintaining the Content Server

Belkin. Automatic Power Management Software. User s Manual

How To Set Up Ops Cser.Com (Pros) For A Pc Or Mac) With A Microsoft Powerbook (Proos) (Prosecco) (Powerbook) (Pros) And Powerbook.Com/

Winpower. User Manual. To find user manual in other languages and software updates, please visit for more information

Winpower. User Manual.

Using an Automatic Back Up for Outlook 2003 and Outlook 2007 Personal Folders

How do I use Citrix Staff Remote Desktop

MiraCosta College now offers two ways to access your student virtual desktop.

UPS Monitoring and Management Software

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

Installing Remote Desktop Connection

Amcrest 960H DVR Quick Start Guide

Acellus Lab Cart. User s Manual. Version 4B. Acellus Corporation Copyright 2010 Acellus Corporation. All Rights Reserved.

UPS MONITORING SOFTWARE USER MANUAL

Virtual Office Remote Installation Guide

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

SNMP Web Management. User s Manual For SNMP Web Card/Box

CANON FAX L360 SOFTWARE MANUAL

Step-by-Step Setup Guide Wireless File Transmitter

User s Manual. Management Software for Uninterruptible Power Supply Systems

1. Installing and configuring APC UPS Management

ren Winpower User Manual

System update procedure for Kurio 7 (For build number above 110)

Changing Your Cameleon Server IP

Procedure for updating Firmware of EZ4 W or ICC50 W

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

CMP-102U. Quick Installation Guide

How To Set Up Dataprotect

ENPS-MF1. 1 USB Port. Multifunctional Print Server. Quick Installation Guide V1.0

Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions

Step-by-Step Setup Guide Wireless File Transmitter

Steps for using MagicConnect

How to remote into the "Backup System"

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

Step by step guide for connecting PC to wired LAN at dormitories of University of Pardubice

PRINT CONFIGURATION. 1. Printer Configuration

Getting the most from your Maxtor OneTouch TM USB hard drive and Linksys Network Storage Link

TE100-P21/TEW-P21G Windows 7 Installation Instruction

Quick Installation Guide

How to Program a Commander or Scout to Connect to Pilot Software

Quick Start. Nighthawk X8 AC5300 Tri-Band WiFi Router Model R8500. Package Contents. NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA USA

SA-9600 Surface Area Software Manual

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Installing LearningBay Enterprise Part 2

progecad NLM User Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

Connecting the DG-102S VoIP Gateway to your network

Quick DDNS Quick Start Guide

If you need additional assistance please contact our Technical Support Center at 24 hours a day, 7 days a week.

Installation and Configuration User's Guide

1. Installing The Monitoring Software

User Guide for Windows 10

Guide to Installing BBL Crystal MIND on Windows 7

1. MOXA NPort Express TCP/IP to RS-232 server

SoundLAB Software Download Software from the Bogen website:

HOW TO USE OIT VIA THE WEB

Mobile Viewer s Access Instruction

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Remote Monitoring and Control of the R&S FSV with a Web Browser

A quick user guide for your LX Apollo DVR

F re Alarm Network etwo (FAN) T rou rou h Virt Vi ual u Private Network etwo (VPN) Dr. Dr Sa S mir H. Abdull--Ja J u a wad

TM Online Storage: StorageSync

Remote Desktop Instructions for the Remote PC Running Windows Vista

Deploying Windows Streaming Media Servers NLB Cluster and metasan

REMOTE DESKTOP SETUP INSTRUCTIONS

Brady IP Printer Installation Instructions

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

EASE Scan Tool Customers. SECTION I - Installation

CM1-Mini Wi Drive. Setup Guide Ver 0.1

Lab: Data Backup and Recovery in Windows XP

Authorware Install Directions for IE in Windows Vista, Windows 7, and Windows 8

Citrix Client Install Instructions

ViewPower User Manual

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

Wireless Setup Guide. Before you start please ensure:

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

1. Hardware Installation

Cloudvue Remote Desktop Client GUI User Guide

Nighthawk AC1900 WiF Range Extender

Installation and Configuration of VPN Software

Using TViX Network. NFS mode : You must install the TViX NetShare utility in to your PC, but you can play the TP or DVD jukebox without stutter.

BSDI Advanced Fitness & Wellness Software

USER MANUAL GRAVITAS SABRE SERIES WINPOWER PC SOFTWARE

PA500II Enterprise Mobile Computer

Infinity C Reference Guide

DSX-HSCS Hot Swap Comm Server

SentryPlus. Shutdown Management Software for Windows. User s Manual

IntraVUE Plug Scanner/Recorder Installation and Start-Up

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Accessing vlabs using the VMware Horizon View Client for OSX

Chapter 1 Installing the Gateway

Quick Installation Guide

SmartWatch Eco/Eco Compact

Transcription:

Quick Installation and Setup for WinPower Software A. On the WinPower Installation menu, simply follow on-screen instructions and key in the software serial number. The installation will be automatically proceeded. Enter the Right serial number here!! B. The software will start automatically after the Operation System is started. WinPower appears as a Green Plug icon in the right bottom corner of the Traybar.

It means the WinPower is running now. C. After you start the system and the WinPower is also running in the Traybar, you have to use Right Click on the Green Plug then click on Start the Monitor to switch on the main screen of the software. Right Click here then click on Start Monitor D. After step C, you would see the screen is switching on as below message. After it runs to 100% you will see the main screen of the software.

E. Here is the main screen of the software. Before you login the software as an administrator, you will see a (Read only) message on the title of the software. It means that you only can monitor the UPS and you cannot change any setting of the software or the UPS. F. To change settings, you need to log in WinPower as an administrator by going to Act as Administrator option of System section. The default password is Administrator.

The default password is Administrator

G. Now, you can find the information of (Read only) is gone. Hence, you can go access other sheets of the software to have your own setting for the software and the UPS now.

Function Explanation of Shutdown Parameter 1. To support the remote monitor/control function of WinPower, you need to have the similar connection as above. It means that the Agent is connected to the UPS via RS232/USB and the other Computers are protected via the AC Power only and all the computers are communicated under the same Network with LAN. 2. All the computers need to install the WinPower software to keep them with the same interface for remote shutdown application. If you don t install the WinPower on them then you would not able to do the remote monitor/control. 3. Owing to the fact that there is no RS232 cable connect to PC-A ~ PC-C, so you will see the message of no connection. Moreover, you would find that these PC is without the in the front of the PC listed in the WinPower monitor screen as below.

4. If all the computers are communicated within the same section of network, the software will detect all the PC which is installed the WinPower and show them in the left window of WinPower as above photo. Notes: Same section of network means the three front numbers of its IP address is the same just like 192.168.1.XXX. 5. If the IP address is out of the same section of the Agent, you have to key-in the IP manually for doing the remote monitor/control via Monitor -> Monitor Remote Device 6. There are two major parts of the sheet of Shutdown Parameter in the WinPower as below.

This part is used for the local Agent only. This part is used for the remote PC 7. There are three items will effect the UPS backup time of the local Agent as below. A. Battery Backup Time (AA minutes) B. Begin shutdown immediately while battery low/battery remaining time is below the setting value /battery capacity is below the setting value C. System shutdown need time (CC minutes) 7-1. In normal status, when the backup time reaches the value of AA minutes, the WinPower would send the command to shutdown the PC. After the CC minutes, the UPS would also shutdown automatically. It means the UPS will work in battery mode for AA+CC minutes.

7-2. If you enable the function of item B, once the UPS transfer to battery mode for XX minutes (XX<AA) and the UPS start to inform the low battery warning. Then the WinPower would send the command to shutdown the PC. After CC minutes, the UPS would also shutdown automatically. It means the UPS will transfer to battery mode for XX+CC minutes. 7-3. If you disable the function of item B, once the UPS transfer to battery mode for XX minutes (XX<AA) and the UPS start to inform the low battery warning. The UPS would still keep working till AA minutes. If the UPS could not support the load till AA minutes, the UPS and the load (PC) would shutdown directly when the battery is empty. If the UPS could support the load till AA minutes, when the backup time reaches the value of AA minutes, the WinPower would send the command to shutdown the PC. After the CC minutes, the UPS would also shutdown automatically. It means the UPS will transfer to battery mode for AA+CC minutes. 8. There are also two main functions on the operation of the Shutdown Remote Agent as below. The item of Shutdown means that when the UPS of the Agent is going to shutdown, the WinPower will send out the shutdown command to the remote PC of the IP that you added in the below space. The item of Discharge means that when the UPS of the Agent transfer to battery for XX minutes, the WinPower will send out the shutdown command to the remote PC of the IP that you added in the below space. Hence, you only can change the time setting when you select this item. If there are more than one UPS in the shutdown conditions list, you can set different shutdown condition of each UPS according your actual status. For example, if there are two UPS (UPS A and UPS B) in the shutdown conditions list, UPS A and UPS B supply power to the remote agent at the same time. Once there is no power for the remote agent, the remote agent will be shut down safely. You should set shutdown condition of UPS A and UPS B, the remote agent won t be shut down until all the condition of UPS A and UPS B is met. 9. Below setting is on the Agent.

9-1. Refer to the left setting, it means that the backup time of the UPS in USB is 10 minutes. 9-2. When the UPS of the Agent transfer to battery mode for 2 minutes, the Agent will send out the shutdown command to 172.168.1.2 & 172.168.1.3. 9-3. When the UPS of the Agent transfer to battery mode for 5 minutes, the Agent will send out the shutdown command to 172.168.1.5 9-4 When the UPS of the Agent is going to shutdown (10 minutes on this sample), the Agent will send out the shutdown command to 172.168.1.8

10. In Remote sides (PC-A, PC-B ), You have to enable the icon of Remote Shutdown by Agent at first. Click Add button in the Shutdown Options, enter IP address of the Agent in the pop up dialog. Press the OK button to finish the setting. After this, When the local Agent received the specified agent's shutdown signal, system can be shutdown in delay time. If you don t enter the IP address of the Agent, the remote PC would not implement the shutdown procedure after it receives the shutdown command from the Agent. 11. The new option: Multi-UPS input If there are more than one UPS supplying power to the local agent as below, you want to safely shut down or suspend the local agent before all UPS can t supply power to the local agent. You should select the Multi-UPS input option in the shutdown settings dialog of each UPS and set condition, refer to the following picture. The local agent won t be shut down or in suspend mode until all the condition of all UPS is met.