INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description



Similar documents
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Life Alarm Fire Alarm Controls

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

SECTION DETECTION AND ALARM

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

AC-115 Compact Networked Single Door Controller. Installation and User Manual

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

TrueAlarm Fire Alarm Systems

Fire Control Panels Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Alliance System Ordering Guide

DTW Works Master Specification Version 2006

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

INSTALLATION MANUAL PC2525. Version 1.1

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3

Using your LED Plus keypad

SILENT KNIGHT MODEL 5207

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Control/Communicator Installation Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

CATALOG NUMBER. Features. Description

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

EDWARDS SIGNAL SOLUTIONS DISTRIBUTED BY: Lee Dan Communications, Inc. Toll-Free:

D287/D288/D292/D293A/D293E

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

Operating the DS9400 Fire Alarm Control/Communicator

FIRE ALARM SYSTEM RECORD OF COMPLETION

TrueAlarm Fire Alarm Systems

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

Fire Alarm System Plans Review Checklist Property location Date of Review

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

FIRE ALARM SYSTEM RECORD OF COMPLETION

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

SECTION FIRE ALARM AND DETECTION SYSTEM

PLAN REVIEW GUIDE FOR FIRE ALARM

Release Control Fire Alarm Systems

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

SECTION FIRE ALARM SYSTEM

HM-W536 Install Guide

CB200W Water Leak Detection Panel Application Guide

SFC-200 SERIES LCD FIRE ALARM PANEL

Self Monitoring Power Supply (BPSM)

Conventional Fire Detection and Extinguishant Control System Specification

Fire Pump Controllers Remote Alarm Panels

Fire Alarm Control Panel. Family. Operating Manual

Premier M Plus & Infinity 8

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

SECTION FIRE ALARM AND DETECTION SYSTEMS

Repeaters and Mimics Data Sheet

EQUIPMENT SPECIFICATIONS

PFC-6030 Fire Alarm Control Panel

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

SECTION FIRE ALARM AND DETECTION SYSTEM

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

Contact ID as of 2/2/2015

DESTINY 1/19/96 # A

SECTION FIRE ALARM AND DETECTION SYSTEM

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Elite-RS Panel Installation Manual

VEGA Analogue Addressable Control Panels

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

TABLE OF CONTENTS FEATURES

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

C. Conform to requirements of Americans with Disabilities Act (ADA).

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

rpsa FIRE PROTECTION ENGINEERS

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Faraday Intelligent Fire Detection Systems

FIRE ALARM SYSTEM Section Page 1

System Introduction S E C T I O N 1

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Contact ID Event Definition Codes

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

FIREDEX Conventional Fire Panels

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

Always on the Lookout Perfect Protection against Burglary

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Transcription:

INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's MR-2100 and MR-2200 Intelligent input fire alarm control panels provide flexible and cost effective operation to satisfy system requirements for both economy and capability. Their modular design assures that as system needs and applicable codes evolve, fire alarm control panel functions can be updated as required. Optional networking modules allows the MR-2100 and MR-2200 to be connected to a Secutron network to provide additional input circuits, visual zones, programmable notification appliance (bell) circuits, and relays. Up to 254 control and annunciator units can be networked together. The network is a DCLR (Data Communications Link, Redundant) configuration loop. The MR-2100 models provide a single intelligent input Signaling Line Circuit for support of up to 198 intelligent devices; up to 99 detectors and up to 99 control/monitor modules. The MR-2200 models provide two SLCs for support of 198 devices on each allowing a total capacity of up to 396 intelligent devices; up to 198 detectors and up to 198 control/ monitor modules total. Option modules are available and can be conveniently field installed. Modules are available for: additional NAC output circuits & function relays, local LED annunciation, additional NAC power, and Central Station (DACT) or Remote Station (DACT or CITY Module) connection. Features Listed to UL 864, 9th edition MR-2100 provides a Single Intelligent Input Signaling Line Circuit (SLC) for up to 198 Intelligent Devices MR-2200 provides Dual Intelligent Input Signaling Line Circuits for up to 396 Intelligent Devices SLCs are selectable for either Class A (Style 6) or Class B (Style 4) operation Two Notification Appliance Circuits (NACs), Class A (Style Z) or Class B (Style Y); expandable to eight NACs with optional MRNC2 modules Four programmable functions relays, Form C; expandable to sixteen relays with MRRL4 modules Programmable cross-zoning functions, day/night mode, and selective control operations Two aux. power outputs, 500 ma @ 24 VDC each 6.0 A Power supply with integral battery charger provides 2.5 A for NACs and Auxiliary Outputs; Expandable to provide up to 7 A NAC Current Four additional communications ports for Dialer, PC Interface, Voice Evacuation System, and Remote Annunciators Optional Style 7 (DCLR) MR network peer-to-peer communications LCD/LED system status display with optional MRLD8 LED zone display modules (required for ULC listed applications) Surface/flush mount cabinet with dead front construction allows up to 12 Ah batteries internally mounted Battery charger is capable of charging up to 35 Ah mounted in an external battery cabinet Cabinet doors are removable for easy installation Terminal blocks are removable for easy wiring Operating program and database can both be uploaded/ downloaded using a Windows based PC with Secutron Programming Software Non-volatile event history log stores 1000+ events Programming the MR-2100/MR-2200 consists of two convenient and easy operations. Input circuit programming and special features (such as cross zoning functions, day/ night mode, selective control operations, etc.) is performed from an externally generated database produced on a Windows based PC. System parameters and control panel display and operation functions are conveniently programmed from the on board LCD and keypad. S6619 S6619 7135-1656:106 7170-1656:117 MEA approved 352-03-E Issue 4 SECUTRON INC. Page 1 of 6 Canada 25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3 Telephone: (905) 695-3545 Fax: (905) 660-4113 Web Page: www.secutron.com U.S.A. 4575 Witmer Industrial Estates, Niagara Falls, NY 14305 Telephone: (888) 695-3545 Fax: (888) 660-4113 E-mail: mail@secutron.com Not to be used for installation purposes.

Main Control Unit System controls consist of eight system switches, an LCD readout, and display entry switches. The display entry keypad is used for technical functions, system/detector maintenance, history recall, device and circuit disarming, and for manual operation of intelligent output modules, relay modules, and notification appliance (bell) circuits. Operator Keys There are eight operator keys. In the figure below, the keys are located on the lower left and are labeled System Controls. The LEDs associated with these keys are used to display function status. The top three keys are pre assigned and are: Acknowledge, Signal Silence, and System Reset. The bottom five keys are user-assignable, selected for the following functions: Lamp Test, Relay Disconnect, Test Mode, Signal Disconnect, Common Disconnect, General Alarm, Selectable Switch Function On, Switch Function Off, or Manual Restart. The panel local sounder will beep once when a valid key is pressed and beep three times if an invalid or unavailable key is pressed. Key presses are recorded in the history log. Intelligent Input Circuits Up to 99 intelligent detectors and up to 99 intelligent control/ monitoring modules may be connected per SLC for a total of 198 intelligent devices. MR-2100 models provide a single SLC output, MR-2200 models provide dual SLCs. Intelligent monitoring modules can be programmed for alarm or supervisory functions. Control modules are available for dry contact or supervised output functions. NAC Outputs Standard are two NACs rated 2 A maximum. NAC output voltage is a nominal 24 VDC, full wave rectified. NAC expansion can be up to eight NACs by using MRNC2 NAC expander modules. Auxiliary Outputs Two auxiliary power outputs are provided, each rated for 500 ma at a nominal 24 VDC, filtered and regulated. INSTRUCTIONS: SYSTEM CONTROLS Acknowledge Signal Silence System Reset User Assigned ALARM SUPERVISORY TROUBLE AC MONITOR BYPASS GROUND FAULT NAC TROUBLE MR-2100/2200 Main Control Panel SYSTEM DISPLAY AND PROGRAMMING ALARM SUPERV TROUBLE MONITOR 1 2 3 4 5 6 7 8 9 ENTER CLEAR HOME LAMP TEST Function Relays The panel comes with four programmable Form C function relays rated 2 A @ 30 VDC resistive. Total function relays can be expanded to 16 by using MRRL4 relay expander modules. Relays can be programmed as Common Alarm, Common Trouble, Common Supervisory, or general purpose functions. Power Supply and Expansion Transformer Each MR-2100 / MR-2200 fire alarm control panel is shipped with a 120 VAC / 240 VAC transformer. Total NAC power can be increased by adding a second transformer, MR-XPS. The standard power supply provides 2.5 A @ 24 VDC (full wave rectified, unfiltered) for the total of NAC and Auxiliary power output. With the addition of an optional transformer, the total NAC and Auxiliary power output is increased to 8 A with up to 7 A available for NACs. Display Information The Main Control Panel LCD readout is backlighted and displays 4 lines with 20 characters per line. With AC power present, the LCD backlighting turns off automatically within 5 minutes if no activity occurs. During AC power failure, the backlighting will turn off within 30 seconds without activity. During normal conditions the display is the main menu which includes the date and a 24 hour clock. During alarm conditions, the first or last (selectable) events of highest priority will be displayed instead of the main menu. A status summary screen lists the number of active alarm, supervisory, or trouble events indicating SYSTEM OFF NORMAL. Enclosure Details The enclosure includes the mounting box, outer door, dead front door, and hardware plate. It can be flush or surface mounted without requiring a separate trim ring. Both the outer door and dead front doors are removable. The hardware plate holds the main printed circuit board and transformer(s). This enclosure holds two transformers, up to three NAC or Relay expander modules, and one communicator module. The backbox is included with the fire alarm control panel and includes an outer lip around the perimeter to provide a built in trim for semi-flush mounting applications. The door conceals the outer lip and provides a neat and clean appearance for surface mounted box applications. Page 2 of 6 SECUTRON INC. Issue 4 Not to be used for installation purposes.

Optional Features NAC Expander Board Model MRNC2 NAC Expander Boards provide two additional NAC outputs. Up to three modules can be added within the basic enclosure and can be any combination of NAC or Relay expanders. NAC Expander Board NACs are rated for 2 A @ 24 VDC each, the same as the standard NACs. Compatible Products LCD Annunciator Model MR-2644 For remote information annunciation, model MR-2644 is an LCD status annunciator with display, general system status LEDs, and general function keys. (MR-2644 is not ULC Listed.) Relay Expander MRRL4 Relay Expander module MRRL4 provides four additional function relay outputs. Each relay provides a Form C contact rated 2 A @ 30 VDC resistive with dry contacts requiring connection to a power limited source. Eight Zone LED Module MRLD8 For local LED panel mounted zone annunciation, the MRLD8 module provides eight zones of LED annunciation, readily visible on the front of the control panel cabinet. Up to three LED modules can be mounted on the front of the cabinet. Each module has label pockets to locally identify zone locations. NOTE: An MRLD8 LED module is required for ULC listed applications. DACT Module - MRDL The optional Digital Alarm Communicator Transmitter (DACT) module is added to the system to provide Remote Station monitoring of system alarms, troubles, and supervisory conditions. Communications are available for : Contact ID, SIA, or 10/20 bps formats. Use of the DACT module requires that two telephone lines be provided for connection to the DACT. Service must be arranged with a Central Station monitoring facility for Remote Station Service. (MRDL is not ULC listed). MR-2644 Remote LCD Annunciator LED Annunciator Model MR-2614 Model MR-2614 is a status annunciator with LED zone display, general system status lights, and general function keys. It provides up to 72 LED zones with three status LEDs per zone. City Connection Module MRCTYB Optional module MRCTYB can be configured for remote Station (reverse polarity) or Municipal Master (local energy) service. The MRCTYB can transmit alarm, trouble, and supervisory conditions when configured for reverse polarity operation. Alarm conditions are only reported when configured for Municipal Master operation. Note: The MR-2100/MR-2200 accepts either the MRDL or the MRCTYB module. MR-2614 Remote LED Annunciator Peer-to-Peer Networking MR-2100/2200 control panels can be networked to other control units for up to a total of 254 network members, each using Style 7 (DCLR) loop communications. One control unit is designated as the master control unit for the network and diagnostics can be done at any control unit. Programming of each individual control unit is done at that unit. Each control unit operates independently in a standalone mode if network communications are lost. Issue 4 SECUTRON INC. Page 3 of 6 Not To Be Used For Installation Purposes.

Specifications Input Power 120 VAC, 60 Hz 2 A maximum 240 VAC, 50 Hz 1 A maximum Mechanical Overall Dimensions with Door Environmental Temperature Range 32 to 120 F (0 to 49 C) Humidity Range Signaling Line Circuit Ratings Voltage Max. number of devices Ratings are per transformer; one additional transformer may be added to increase capacity 16-7/8 W x 29-1/2 H x 5-1/4 D (429 mm x 749 mm x 133 mm) [see page 5 for mounting box detail] Up to 93% RH, non-condensing @ 90 F (32 C) maximum 24 VDC nominal, 27.5 VDC maximum Compatible devices Refer to list on page 5 Maximum line length Operation modes MR-2100, Single SLC: 198 total, 99 detector, 99 control/monitor modules MR-2200, Dual SLCs: 396 total, 198 detectors, 198 control/monitor modules 3045 m (10,000 ft) (12 AWG, 3.31 mm2) Available as Style 6 (Class A) or Style 4 ( Class B); T-tapping is allowed with Style 4 (Class B) connections only Notification Appliance Circuit Output Circuits, Standard and Expansion NACs NAC Output Ratings NAC Current, Standard with One Transformer NAC Current with Optional Transformer 2 A maximum per NAC; 24 V full wave rectified DC output; power limited Total of NACs + Auxiliary Power = 2.5 A maximum (if Aux. Power Total = 500 ma; NAC power = 2 A maximum) Total NAC current = 7 A maximum Total of NACs + Auxiliary Power = 8 A maximum (optional transformer MR12VAC or MR24VAC) Function Relay Output Circuits, Standard and Expansion Relays All Relays Power Output Circuits Auxiliary Power Outputs (two outputs) Battery Information Battery Charger Float Charge Charging Current Maximum Battery Capacity Communications Ports ANN (annunciator port) RS-232-2 (MV-2700 or GRID) CON4 (Dialer/City Module Port) J1 (Service port or serial printer port) Network Ports COM1, COM2 (Secutron MR peer to peer network, redundant DCLR) Network Wiring Parameters (maximum line resistance = 680 ohms) 2 A @ 30 VDC resistive; Form C contacts; requires power limited source Each output is rated 500 ma @ 24 VDC, filtered, regulated, and power limited; maximum ripple voltage = 600 mvpp current limited float charger for sealed lead acid batteries 27.5 VDC 2.7 A maximum, no auxiliary loads; 1.7 A nominal with 0.5 A on each Auxiliary output 12 Ah maximum size internal to cabinet; 35 Ah maximum size allowed, requires model MR2978 External Battery Cabinet Fixed baud rate @ 4800 bps; for use with MR-2614 or MR-2644 Annunciators (refer to individual product Installation Instructions for capacities and wiring distances) Fixed baud rate @ 9600 bps; 20 ft (6m) maximum distance; for use with MV-2700 Voice Evacuation System or GRID Graphical PC Display Fixed baud rate @ 4800 bps; for use with MRDL Digital Communicator Module or MRCTYB City Module Fixed baud rate @ 9600 bps; 6 m (20 ft) maximum distance; for use with Service/Programming PC (using Windows 95 or 98); or for serial input printer Standard Protocol: 10km (33,000 feet; 6.2 miles) maximum distance between nodes, minimum 28 AWG wires (0.081 mm2); Total panel capacity varies with programmable baud rate: up to 254 panels with 9600, 4800, and 2400; up to 200 panels at 1200 RS-232 Protocol: up to 20 m (66 ft), typically for connection to external modem Baud Rate 9600 4800 2400 1200 Maximum Capacitance 100 nf 220 nf 470 nf 680 nf Maximum Network Nodes 254 254 254 200 Page 4 of 6 SECUTRON INC. Issue 4 Not to be used for installation purposes.

Compatible Intelligent Devices Compatible Intelligent Devices Reference Information Model Description MRI-1251B Intelligent Ionization type smoke detector MRI-2251B Intelligent Photoelectric type smoke detector MRI-2251TB Intelligent Photoelectric type smoke detector with thermal element MRI-2251TMB Acclimate Intelligent Photo-Thermal Detector DNR Intelligent photoelectric duct smoke detector (No head included) MRI-5251B Intelligent Thermal detector, Fixed Temp. 135 F MRI-5251RB Intelligent Thermal detector, Fixed Temp. and Rate of Rise, 135 F MRI-5251H Intelligent Thermal detector, Fixed Temp. 190 F MRI- M500DM Intelligent Dual input monitor module MRI-M500M Intelligent Monitor module, Class A/B initiating MRI-M501M Intelligent Mini-monitor module, Class B initiating MRI-M502M Intelligent Monitor module for 2-wire smoke detectors Class A/B initiating MRI-M500S Intelligent Supervised control module MRI-M500R Intelligent Dual Form C relay module MRI-M500X Fault isolator module MR-2100 & MR-2200 Back Box Dimension Reference 14-1/2" (368 mm) 7/8" (23 mm) lip each side Door outline reference; dimensions: 16-7/8" W x 29-1/2" H x 1-1/4" D (429 mm x 749 mm x 172 mm) 16-1/8" (410 mm) 3/4" (19 mm) lip top and bottom 3" (76 mm) 4" (102 mm) 21-3/4" (552 mm) 26-1/2" (673 mm) 29" (740 mm) 5-1/4" (133 mm) 1-1/4" (32 mm) 27-1/2" (699 mm) 8-1/2" (216 mm) Issue 4 SECUTRON INC. Page 5 of 6 Not to be used for installation purposes.

Ordering Information MR-2100 and MR-2200 Fire Alarm Control Panels Model Description Standby Current Alarm Current MR-2100R MR-2100B MR-2200R MR-2200B Optional Panel Modules MRNC2* Single SLC Fire Alarm Control Panel, 120 VAC input, Red Single SLC Fire Alarm Control Panel, 120 VAC input, Beige Dual SLC Fire Alarm Control Panel, 120 VAC input, Red Dual SLC Fire Alarm Control Panel, 120 VAC input, Beige Dual NAC Expansion Module (output ratings are the same as standard NACs) 110 ma 175 ma 10 ma 65 ma MRRL4* Four Relay Module 5 ma 17 ma/relay MRLD8 Eight (8) LED Module; Quantity 3 maximum, 2 maximum if for Canada (Alarm current is for 3 devices in alarm, add 5 ma each if more) ULC listed applications require a minimum of one MRDL8 LED module 5 ma 15 ma (see current note) MR-XPS Expansion Transformer, 120/240 VAC NA NA MRDL** DACT Module 33 ma 60 ma MRCTYB** City Connection Module 20 ma 20 ma Optional Network Modules Port 1 Operation Port 2 Operation MR22NTWR Standard Standard MR22NTWR1 RS-232 Standard MR22NTWR2 Standard RS-232 MR22NTWR12 RS-232 RS-232 * Select any combination for up to 3 modules total. ** Quantity one maximum from these modules. Page 6 of 6 SECUTRON INC. Not to be used for installation purposes. Issue 4 Secutron reserves the right to make changes at any time without notice in prices, colors, materials, components, equipment, specifications and models and also to discontinue models. Modul-R is a trademark of Secutron Inc.