DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER



Similar documents
Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Secure your IT equipment with confidence... secure with NetClosure

InstaPATCH ZERO Solution Guide

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Dimensions (HxDxW) Total Cabinet Area 89.96x x 24 in/ 2,285 x 1, x mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.

Cabinets 101: Configuring A Network Or Server Cabinet

Rack Installation Instructions

Customized Server Cabinets

Rittal Liquid Cooling Series

ADC-APC Integrated Cisco Data Center Solutions

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Introducing an innovative team devoted to providing unparalleled customer service and support for ISPs, ASPs and Hosting applications.

Layer Zero. for the data center

Access Server Rack Cabinet Compatibility Guide

SERVER ROOM CABINET INSTALLATION CONCEPTS

Rack Systems Solutions

Key Considerations for Selecting Server Cabinets for Seismic Areas

How To Build A T7 Rack For Information Technology

Compaq Rack Options and Accessories. Monitors and Keyboards

Vantage Enclosure Systems

APC APPLICATION NOTE #92

Element D Services Heating, Ventilating, and Air Conditioning

Rack Hygiene. Data Center White Paper. Executive Summary

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

How To Fit A Dll 2420 And 4220 Rack Enclosure

Managing Data Centre Heat Issues

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Cabinet & Enclosure Systems

DELTA3-1. Delta 3 Data Centre Rack Solution

Installation. Basic Rack Power Distribution Unit for Blade Servers

DATA CENTER SOLUTIONS GUIDE

AU-110 racking guide NBXPN: 023

F-SERIES TERAFRAME HD CABINET SYSTEM

DCF Optimized Rack System Selection Guide

Cabinet Overview Frame Material & Construction. Shelves Fan Options Cable Trays Blank Panels Brush Cable Entry

How to Meet 24 by Forever Cooling Demands of your Data Center

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Storage Solutions. Maximize Storage & Optimize Space

Powerware Enclosure Solutions Product Focus

Rack Basics: Everything You Need to Know Before You Equip Your Data Center

Cabinet V800 V800 CABINETS

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

Data Center Components Overview

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

Choosing Close-Coupled IT Cooling Solutions

DCF Optimized Rack System

Layer Zero. for the data center

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Benefits of. Air Flow Management. Data Center

Thermal Optimisation in the Data Centre

Organizing and Managing Equipment Rooms

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

DATA CENTER SOLUTIONS

DATA CENTRES POWERED BY EXCEL

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

Energy-efficient & scalable data center infrastructure design

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

APC APPLICATION NOTE #112

Rack installation instructions

Data Center Cooling: Fend Off The Phantom Meltdown Of Mass Destruction. 670 Deer Road n Cherry Hill, NJ n n

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Free-Stand Cabinets PROLINE Network Switch Cabinets

How To Buy Anixter Data Center

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Great Lakes Data Room Case Study

Rack Blanking Panels To Fill or Not to Fill

Airflow Simulation Solves Data Centre Cooling Problem

In Row Cooling Options for High Density IT Applications

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Airflow Management Solutions

Data Center Racks. Vantage S2. Enclosure System. Switch N to Eaton.

ADC Structured Cabling Solutions

DIGITUS Network & Server Cabinets. UNIQUE Series

(Examples of various colocation sites)

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Driving Data Center Efficiency Through the Adoption of Best Practices

Data Centre Infrastructure Assessment

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Environmental Data Center Management and Monitoring

vantage S2 enclosure system

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Rack Cabinets. Rack Configuration. 19 inch

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

Server Chassis and Triplet Hardware v1.0

42U/45U 28" Wide Rack Installation & Service Guide

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Transcription:

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

EXECUTIVE SUMMARY Data center racks were once viewed as simple platforms in which to neatly stack equipment. As data center densities have increased, however, data center racks have come to play a vital role in the availability, reliability and flexibility of the IT infrastructure. The right rack enclosure can also reduce data center operational costs by preserving valuable floor space, optimizing cooling and increasing the efficiency of IT staff. Four factors have altered the landscape for data center rack selection: Increasing weight loads Offsite integration processes Multivendor IT environments Increased cooling costs Organizations need data center racks that can hold heavier loads and maintain their structural integrity when shipped fully loaded with equipment. Racks should also provide the flexibility to accommodate equipment from multiple vendors with varying locations for cabling and power distribution. High-density data centers further demand racks that provide maximum usable space, minimal air mixing, adequate clearances for airflow, and easy access for troubleshooting and reconfiguration of equipment. Although data center racks come in standard sizes, not all products deliver these capabilities. This whitepaper will discuss some of the key considerations in choosing racks for today s data center environment. It will then examine some of the characteristics that make DAMAC s Fastrack a superior choice to meet those requirements now and in the future. 2

A DAMAC WHITEPAPER STRENGTH AND STRUCTURAL INTEGRITY Organizations are demanding that their data centers deliver 24x7 availability, top performance and ever-increasing storage capacity. As a result, the physical data center infrastructure is under mounting pressure to support growing server and storage densities. Studies indicate that the average power density per rack will reach 12kW in 2014 double the average 6kW power density per rack in 2006. Equipment is also getting heavier due to increased data storage requirements and the cooling demands of next-generation processors. Five years ago, data center racks needed to hold about 2,000 pounds. Today, weight loads of 3,000 pounds or more are not uncommon. At the same time, many organizations are turning to offsite integration processes to minimize the disruption associated with installing, configuring and integrating equipment within the data center environment. System integrators rack and stack equipment in fully configured units for delivery to the customer s site. The structural integrity of the data center rack becomes even more critical in this scenario. The rack must not only hold the weight of the equipment when stationary but withstand the stresses of shipment. The transportation stresses mimic a seismic event that exerts force on both the x and y axes of the racks structural members. The typical data center rack is made of formed or folded sheet metal, a construction that provides vertical but not horizontal strength. Furthermore, most manufacturers save time, labor and material by using stitch welding rather than a continuous seam weld. As a result, weight loads must be limited to about 2,000 pounds for the rack to arrive with its original structural integrity. Otherwise these racks tend to become deflected when shipped fully populated with equipment. Poor-quality racks may buckle, damaging valuable equipment. But even if the rack appears undamaged when it is uncrated and moved into the data center, IT personnel often find it difficult to remove equipment from the rack for servicing. The deflection of the rack alters the distance between the rails such that the mounting area no longer follows Electronic Industries Alliance (EIA) specifications. THE DAMAC DIFFERENCE DAMAC s Fastrack is constructed of tubular steel, which lends itself to horizontal as well as vertical strength. In addition, each seam and joint is fully welded, eliminating the inherent failure points associated with stitch welding. 3

Fastrack can hold 3,500 pounds of equipment when stationary, enabling it to facilitate growing weight loads. More importantly, it will maintain the EIA specification within the mounting area when shipped fully populated with up to 3,000 pounds of equipment. Fastrack also features larger casters than competitive products. This provides greater floor clearance, making it easier to load and unload the rack from a shipping crate and move a fully populated rack on both flat and angled surfaces. A fully welded, seismic floor mounting plate is built into the base of the rack. The floor mounting anchor points and levelers are set outside of the equipment mounting area for easy accessibility when the rack is fully populated. Grounding provisions are included in the frame to tie the rack into the facility central ground. EASE OF USE AND FLEXIBILITY Data center racks have become taller, wider and deeper to accommodate increasing equipment densities. The most popular racks are 42U, 45U or 48U high, 24 inches or 30 inches wide and 42 inches or 48 inches deep. However, these industry-standard specifications do not indicate how much usable space is available inside the rack. This is an important consideration given that IT managers are building up cabinets in order to maximize valuable data center space. Any industry-standard rack will support the mounting of 19-inch equipment, but may not provide the capacity for growing cabling and power distribution requirements. Because space is at a premium in racks constructed from sheet metal, organizations often purchase larger cabinets to ensure that cables and power distribution units (PDUs) don not block access to equipment. While the value of orderly cabling may be worth the investment in a larger rack and associated floor space, a rack that can support cable management within a smaller footprint delivers a greater ROI. The dynamic nature of today s data centers also demands slide in, slide out component mounting and streamlined cable management. IT staff efficiency is another important factor.time savings equates to reduced costs as well as a more efficient and flexible environment. Single-piece panels held on by screws make it difficult to work on equipment in traditional racks. Poor cable and PDU management limits the flexibility, accessibility and ease of use of many cabinets. 4

A DAMAC WHITEPAPER THE DAMAC DIFFERENCE Because tubular steel is less bulky than sheet metal, Fastrack provides 20 percent more usable space than competitive products and thus more room for cabling and power distribution equipment. The top panel, side panels and doors are easily removed, making it easy to work on a fully populated rack. Side panels are recessed into the cabinet frame with slam latches for locking. This adds no width to the overall rack footprint and allows for zero clearance coupling between cabinets. The top panel has multiple cable pass-through ports to facilitate routing cables above the cabinet. Fastrack features a rear coffin section an industry first dedicated to PDU mounting and cabling. It recesses into the tubular steel frame of the cabinet, allowing easy access to the rear of the equipment. It is not necessary to unplug power strips or disconnect cables to service equipment from the back side. The coffin section includes standard PDU mounting provisions on both sides, making Fastrack field-configurable to the specific requirements of the equipment. There are multiple provisions to accommodate all popular PDU manufacturers, including ServerTech, Geist, Raritan and APC. The rear coffin section also includes a vertical cable manager with routing fingers set at each rackmount unit location to maintain the proper bend radius of the data cables. The cable manager can also be installed on the left or right side to meet the cable dressing requirements of the equipment. A locking cover ensures that cables do not drift out of position when the cabinet is shipped. COOLING EFFICIENCY High-density data centers demand effective thermal management. Because high temperatures and humidity can lead to equipment failure, proper cooling plays a key role in maximizing system availability and longevity. Most equipment is designed to draw chilled air in through the front and exhaust hot air through the back. As a result, industry best practices call for racks to be arranged with cabinet fronts facing each other (the cold aisle) and cabinet backs facing each 5

other (the hot aisle). This hot-aisle/cold-aisle configuration prevents hot exhaust air expelled from the back of one rack to be drawn into equipment across the aisle. Traditional racks often require airflow management accessories to make them compatible with hot-aisle/cold-aisle arrangements. Blanking panels and vertical airflow baffles must be added to prevent short cycling and ensure that hot exhaust air is not drawn back into the cool aisle. However, add-on equipment cannot provide the optimized airflow needed to support high-performance equipment in a high-density data center environment. Due to the increased heat load of next-generation servers, equipment manufacturers increasingly call for clearances of 6 to 11 inches to ensure proper airflow. It is important to select a data center rack with sufficient capacity and cabling management for unobstructed airflow through equipment. Cooling is one of the largest expenses in any data center, making cooling efficiency one of the most important considerations when selecting a data center rack. Airflow efficiency within the rack can lower operational costs dramatically by reducing the amount of chilled air that must be circulated. A rack that is built to enhance the facilities cooling system will reduce chilled air volumes even further. As a result, an investment in cabinets with advanced cooling features can pay big dividends. THE DAMAC DIFFERENCE DAMAC s energy-efficient cabinets are hot-aisle/cold-aisle ready and exceed active equipment airflow requirements. In addition, a built-in front perimeter air dam eliminates air mixing when the mounting rails are kept in the preset factory position. Air does not leak above, below or along the sides of equipment, helping to ensure that equipment is optimally cooled. The rear coffin section of the Fastrack cabinet further increases cooling efficiency by ensuring that cabling and PDUs do not block exhaust air from exiting the rear of the cabinet. The fully perforated mesh door also provides airflow of 82 percent or more. Customers are typically able to raise the temperature in their data centers a minimum of two degrees because of the high airflow design of Fastrack. This set point can be further increased if Fastrack is installed along with the DAMAC aisle containment system, which doubles or quadruples cooling efficiency by physically separating the hot and cold aisles. 6

A DAMAC WHITEPAPER CONCLUSION In terms of cost, the data center rack is relatively insignificant compared to value of the equipment it houses and the cost of the labor to configure and integrate that equipment. Nevertheless, it is a strategic component that must be carefully selected with today s data center challenges in mind. The right rack will provide the structural integrity, flexibility and cooling support needed in a high-performance, high-density data center environment. It will also enable offsite integration processes, arriving in perfect condition when shipped fully loaded with preconfigured, pre-integrated equipment. DAMAC s Fastrack has the strength to support growing equipment weight loads within the data center and in transit, along with superior ease of use and airflow optimization. It provides the features needed in today s dynamic multivendor data center environments, delivering reduced operational costs, increased efficiency and investment protection. 7

www.damac.com 14489 Industry Circle La Mirada, CA 90638 (877) 670-0496