Structural Pipe Lining Technology



Similar documents
Where life interacts with infrastructure.

SA Pipe Relining is dedicated to finding simple, non intrusive

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

DRAINAGE PIPE REPAIR & RELINING SOLUTIONS

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

The Town of Lakeshore Basement Flooding Information to Residents

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

SIDE SEWER CONDITION ASSESSMENT AND REPAIR RECOMMENDATIONS

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

Interactive Decision Tree Automates Sewer Rehabilitation Planning

We love the drains you hate! A partner you can depend on to deliver dedicated drainage maintenance services, 24 hours a day, 365 days a year

At the end of today s seminar you should be better. Recognize the causes of Sewer Lateral backup. Identify techniques to protect your home from

SASTT contact details:

REPAIRS TO DAMAGED SEWERS

by Leonard Friesenhahn, P.E.

Advance Systematic Engineering Sdn. Bhd. Kejutraan Sistematik Maju Sdn. Bhd. RC/

Sewer Rehabilitation Design Requirements

Township of Enniskillen. Asset Management Plan

Canada Pipe Lining Technology.

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

Home page Previous Next

Why Do I Have Sewer Smells In My Home or Business?

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

BELCO PIPE RESTORATION

CCTV PIPE INSPECTION AND EVALUATION RUNWAY 17L-35R

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

TREE ROOTS & SEWER LINE INTRUSION

ELASTOMERIC INLINE CHECK VALVES FOR CONTROL AND PREVENTION OF SANITARY SEWER OVERFLOW

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

UVDB empowered by Achilles

UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS

A Guide to Structural Waterproofing

Meeting the Challenge of Pipeline Emergency Repair

Sanitary Sewer Smoke Testing

Module 19: Roof drainage

St. Joseph, Missouri Water Protection Homeowners Guide to Your Sewer

Guaranteed Solutions for Solving Sewer Backups


INFORMATION PACK. Registered Company Address. Contact Names Robert Hatton Chris Jones. Telephone

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Prepare a drainage system layout and specification notes for a low- rise building.

First in Service First in Safety

PLANNING CAREFUL NORTH VANCOUVER PIPE BURST REQUIRES

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

Public Outreach Meeting

Preventing water damage in the basement

DEPARTMENT OF ENVIRONMENTAL QUALITY

Sewer Pipe & Manhole Rehab. Jack Keys Collection System & Inspection Services Supervisor Southern Clinton County Municipal Utilities Authority

Sewer systems: Failures and rehabilitation

Guidelines for closed circuit television (CCTV) inspection of newly constructed sewers

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

Branch out with lateral cutting & drain cleaning

Rainwater going astray. EPROPOX FC30 epoxy resin system to be prepared for a rainy day

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

Sewerage Operation and Maintenance. Tokyo Metropolitan Government Bureau of Sewerage Facilities Management Division, Pipeline Management Section

Waste Management. Infrastructure Rehabilitation in the U.S. Virgin Islands

PREVENTING WET OR FLO ODED BASEMENTS

Welcome to the DALROD e-brochure

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

Home Drainage & Causes of Basement Flooding. Water

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Rehabilitation or Replacement? That Is The Question

SPR PE Steel Reinforced Liner

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

What Causes Foundation Leaking?

DRAIN, WASTE AND VENT PLUMBING

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

foundation designed to keep water out of the basement.

SEWER CLEANING, INSPECTION AND ASSESSMENT

SELF-INSPECTION CHECKLIST Maintain Your Roof and Identify Potential Issues With Bloom s Comprehensive Self-Inspection Guide

How to Prevent Liquid Damage Property Losses

Waste Collection Systems

Premature Storm Drainage System Repairs and Replacement

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

The leader in trenchless rehabilitation

When considering Roof drainage design the following should be taken into account:

Transcription:

Structural Pipe Lining Technology

ABOUT US Nu Flow install innovative technologies to rehabilitate failing or deteriorating piping systems. These technologies are non-invasive, in-situ, and offer a greener alternative to pipe replacements. We are specialists in small diameter pipe rehabilitation and offer bespoke services for large diameter pipelines also. Nu Flow is a member of the Aquam Group, offering 300 years of accumulated experience in the water and gas pipeline industry.

BACKGROUND Over 300 Nu Flow licensees worldwide Approximately 25,000+ piping systems rehabilitated every year using Nu Flow s technologies Epoxies have an estimated 80 year lifespan and a corporate warranty rate of <1%

ABOUT NU DRAIN TECHNOLOGY A cured-in-place pipe (CIPP) system developed in 1998 by Nu Flow Technologies Creates a long-term, structural pipe inside the existing host pipe system without digging or destruction to buildings or landscape Best suited for pipe diameters of 20mm (¾ ) to 300mm (12 )

VERSATILE APPLICATIONS Vertical Sanitary Stacks Horizontal Sewer Branches Sewer Mains Roof Drain Systems Spot Repair Liners

Step 1. System Diagnosis & Set Up Step 3. Pipe Lining Step 2. Pipe Cleaning Step 4. Bladder Removal & Evaluation

BENEFITS OF USING NU DRAIN TECHNOLOGY Non-disruptive to building fabric No-digging required Preserves the life of the pipe Eco-friendly Cost effective Minimal downtime of systems Permanently repairs leaks Maintains pressure and flow Prevents future corrosion Safe and durable Watch Our Demo Video

NU DRAIN CASE STUDY: YORKSHIRE WATER Nu Drain technology used by Yorkshire Water to rehabilitate a number of clay and pitch fibre sewer drainage pipes in built-up residential areas. Pipes were all located in difficult to access spaces and experienced problems such as blockages, damaged pipes, and cracked joints Pipe replacement would have been extremely disruptive for local residencies and road users

NU DRAIN CASE STUDY: BEVERAGE ALCOHOL PRODUCER Global leader in beverage alcohol with iconic brands in spirits, beers and wines, located in Dublin, Ireland.. Drain system serving the production facility with pipe diameters ranging from 100mm (4 ) to 225mm (9 ) The drain system suffered multiple blockages, circumferential fractures, open joints, leaks, and collapsed and broken pipe sections Only alternative solution for the customer would have been to dig up and replace the entire system Our skilled technicians were able to rehabilitate the failing drain system using our unique pull-inplace technology, and did so without disrupting daily operations in the plant

NU DRAIN CASE STUDY: DUBLIN PORT 110m of concrete sewer pipeline running below a port terminal, security hut, ship docking area, and dock yard. Experienced system failure during times of high tide due to multiple open joints Nu Drain was used to seal all joints and prevent ingress of tidal water

NU DRAIN CASE STUDY: LANCASTER HALL HOTEL 40 year old sanitary drain pipes on 80 toilets 110mm (4 ) cast iron pipes suffering cracks and holes. Nu Flow are currently rehabilitating these pipes with the Nu Drain technology to offer a permanent solution The Hotel is remaining in operation whilst works are carried out

NU DRAIN CASE STUDY: AVIVA STADIUM Difficult to access 580mm (22 ) HDPE rainwater pipe which was a main outlet for rainwater off the stands. Problematic joints causing blockages, back-ups and leaks Failing system ran under the stadium arena and into the electrical supply room, therefore a costly shutdown to the busy stadium would have been required if the customer had chosen a traditional repipe Technicians gained access above the electrical room and were able to clean and fully reline the problematic area using the Nu Drain structural liner

To view more case studies please visit our website; www.nuflowtech.com Or for more information contact; info@nufloweurope.com UK: +44 844 543 3540 Kingsley Hall, 20 Bailey Lane, Manchester Airport, Manchester, UK, M90 4AN. Ireland: +353 (0)1 6510302 Unit H2, Maynooth Business Campus, Straffan Road, Maynooth, Co. Kildare, Ireland, W23 KH76.