Flowtite Jacking Pipe

Similar documents
TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Installation of Large Diameter Buried Pipes

SECTION NONREINFORCED CONCRETE SEWER PIPE

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

Green Thread Product Data

The Unique, Centrifugally Cast, Fiberglass-Reinforced, Polymer Mortar Pipe

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

Wastewater Capital Projects Management Standard Construction Specification

Repair or Replacement - Band-Aids vs. Surgery

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Rehabilitation or Replacement? That Is The Question

SPR PE Steel Reinforced Liner

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)


PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

Pipeline Replacement using Relining

SECTION DUCTILE IRON PIPE AND FITTINGS

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Royal Seal Gasketed Sewer Pipe

NON-CIRCULAR SEWER LINER INSTALLATION AND FUTURE PROJECTS IN LOS ANGELES

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

GRP Pipe systems. for Water, Sewage and Industrial Applications

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Summary 7/11/2012. Michigan Water Environment Association 2012 Annual Conference Boyne Mountain Resort

Trenchless Technology for Drainage Structures

DIVISION 4300 STORM DRAINAGE

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

CHAPTER 6 - SANITARY SEWER

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Series 4000 Fiberglass Pipe and Fittings

Meeting the Challenge of Pipeline Emergency Repair

Oil and Gas Pipeline Design, Maintenance and Repair

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

Trenchless Construction Technology and Issues

City of Lincoln, Nebraska STEVENS CREEK BASIN TRUNK SEWER TECHNICAL MEMORANDUM NO. 5 PIPE MATERIAL SELECTION TABLE OF CONTENTS

TECHNICAL SPECIFICATION

Introduction to Pressure Pipe Rehabilitation with CIPP

Structural Rehabilitation of Rigid Pipes. George McAlpine 1, Affiliate, ASCE

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

Appendix A: Acceptable pipe and fitting materials

APPLICATION OF GLASS-REINFORCED PLASTIC TO SEWER REHABILITATION

Carlon Bore-Gard and Boreable Multi-Gard Raceway

Beacon Hill Sewer District Standard Specifications

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

CONSTRUCTION OF NON-CIRCULAR SEWER REHABILITATION PROJECTS IN LOS ANGELES

Concrete Pipes. Concrete Pipes

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

TRENCHLESS TECHNOLOGY RESOURCE CENTRE TRENCHLESS TECHNOLOGY GUIDELINES

PRECAST CONCRETE BOX CULVERTS

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

Water Transmission & Sewer Force Main Renewal 16 through 60

Section SEWER PIPE INSTALLATION AND TESTING

SECTION UNDERGROUND ELECTRIC SERVICE

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

SECTION POLYVINYL CHLORIDE (PVC) PIPE

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

Sewer Line Rehabilitation

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Prestressed Concrete Pipe Fitness for Service and Repair

Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling

Greensboro s Pilot Program for Water Pipe Bursting Leads to Expanded City Wide Program

WEFTEC.06. Kent Von Aspern,* Collins Orton** *Carollo Engineers 2700 Ygnacio Valley Rd Suite 300 Walnut Creek, CA 94598

Annular Space Grouting of Slipline Products

SECTION STORM DRAINAGE SYSTEM

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Sewer network renovation using glass-fiber reinforced (GRP) pipe liners

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

Structural Testing of GeoPolymer Pipe/Culvert Lining

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54

Transcription:

U.S. COMPOSITE PIPE SOUTH, LLC. MEMBER OF KTI PIPE GROUP OF COMPANIES Flowtite Jacking Pipe 18585 Samuels Rd. Zachary, La. 70791 PH. 225-658-6166 Fax 225-658-0947 www.flowtitepipe.com Flowtite GRP Pipe Systems

Trenchless Technology Today s growing urban areas may make it impractical to make open trench excavations and disrupt the surface conditions in order to install, replace or renovate underground piping systems. Trenchless" technology includes the lining of existing pipes, called slip lining, where a new pipe is installed inside the existing deteriorating pipe. It can also include the microtunneling process of boring a hole and pushing or jacking the new pipe into the created excavation. U.S. Composite Pipe South has products/technology to meet these new application needs. Flowtite Jacking Pipe The Flowtite manufacturing process is unique in that it easily permits a custom product to be made to meet the specific project requirements. With the ability to make custom diameters and wall thickness, Flowtite can create the optimum pipe size to match the capacity of the equipment of the tunneling machines. This allows to have longer jacked pipe runs Flowtite Sliplining Pipe The Flowtite technology can create the optimum pipe size to match the inside diameter of an existing pipeline. This will provide the maximum flow capabilities while still permitting ease of installation. The ability to manufacture variable lengths (standard length 10, 20 or 40 feet) can further help reduce installation time. Reduced installation time means lower installed costs and less down-time for the pipeline that is being rehabilitated. Features Benefits 1 Minimizes the loss of interior dimension of the existing pipe, maximizes flow capabilities Easier, faster installation, less pipe line service down-time

Flowtite Jacking Pipe The Flowtite jacking pipe is a Fiberglass Reinforced Polymer (FRP) pipe produced on the continuously advancing mandrel process, ensuring a consistently uniform product foot-by-foot. Immune to galvanic and electrolytic corrosion. Its proven resistance to the acidic environment found in a sanitary sewer speaks well for its use in waste water applications. The Flowtite Jacking Pipe is manufactured using the continuous advancing mandrel process which represents the state of the art in FRP pipe production. This process allows the use of continuous glass fiber reinforcements in the circumferential direction. For a buried conduit, the principle stress is in the circumferential direction; thus, incorporating continuous reinforcements in this direction and not just chopped discontinuous roving such as in a centrifugal casting process, yields a higher performing product at lower cost. Using technology developed by material specialists, a very dense laminate is created that maximizes the contribution from three basic raw materials. Both continuous glass fiber rovings and chopped roving are incorporated for high hoop strength and axial reinforcement. A sand fortifier is used to provide increased stiffness with placement near the neutral axis in the core. With the Flowtite dual resin delivery system, the equipment has the capability of applying a special inner resin liner for severe corrosive applications while utilizing a less costly resin for the structural and outer portion of the laminate. The Flowtite Jacking Pipes are supplied in standard lengths of 10 and 20 ft; however shorter lengths are available upon request. www.flowtitepipe.com 2

Gorut Ports and Jacking Pipes for Intermediate Jacking Stations The inclusion of intermediate jacking stations will In order to facilitate the installation process, the allow the Flowtite Jacking Pipe to handle overall Flowtite Jacking Pipe can be supplied with grout jacking lengths. When intermediate jacking ports for the introduction of bentonite lubricant. stations are needed, special Flowtite "interjack" pipes can be manufactured with deep gasket grooves and thicker walls to accommodate this type of jacking technique. The installing contractor needs to supply the hydraulic jacking rams and the energizing medium. 3

Joint System The standard joint for a Flowtite jacking pipe incorporates a push on full fiberglass collar which is mounted integral to the pipe wall. The fiberglass collar mates against an EPDM or Nitrile rubber gasket firmly joined to the pipe wall. In order to ensure a uniform pressure transfer between the ends of the pipe, a ring made of soft wood is provided. The thickness of the wood ring is between 0.4 and 1.0 inch. Compression of the ring in high stress areas tends to redistribute any point load concentrations. The joint is designed to meet the performance requirements as specified in ASTM D4161. The requirements in ASTM D4161 are some of the more stringent for any pipe system in the world. Additionally this joint has been tested to an external hydrostatic pressure of 120 psi. This is the equivalent to having the water table at 277 ' on the top of a buried pipe. 4

Jacking Pipe Dimensions Nominal Diameter Pipe OD Nominal Pipe ID Nominal Wall Thickness Pipe Weight (lb/ft) Allowable Pushing Force SF=2.5 (tons) Allowable Pushing Force SF=3.0 (tons) 151 201 126 24 25.8 22.4 1.67 28 30.0 26.4 1.80 114 144 30 32.0 28.2 1.89 162 232 193 36 38.3 34.3 1.99 205 303 252 42 44.5 40.5 1.99 240 356 296 45 43.7 391 326 46.7 2.03 2.03 262 48 47.7 50.8 281 421 351 51 53.9 49.8 2.05 301 453 378 54 57.1 2.05 320 481 401 57 60 60.0 53.0 55.9 62.9 2.05 2.20 337 379 507 58.5 588 66.0 61.9 2.08 376 570 423 490 475 69.2 75.4 64.5 2.35 70.4 2.50 446 517 711 844 63 66 72 167 592 703 NOTES: 1. Outside diameters for pipes up to 48" (nominal) are in accordance with ASTM D3262 table 3 2. Different pipe dimensions are available upon request 5

Although the utmost care has been taken to ensure the accuracy of the contents of this brochure, US Composite Pipe South does not accept liability for errors or omissions in this publication. Customers must satisfy themselves of the suitability of a given product supplied or manufactured by US Composite Pipe South. U.S. COMPOSITE PIPE SOUTH, LLC. 18585 Samuels Rd. Zachary, La. 70791 PH. 225-658-6166 Fax 225-658-0947 www.flowtitepipe.com MEMBER OF KTI PIPE GROUP OF COMPANIES