MCAL Spectrophotometry. Spectrophotometry



Similar documents
Agilent Cary 60 UV-Vis

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Copyright by Mark Brandt, Ph.D. 12

instruments Analytical Instruments for Science

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

VWR SPECTROPHOTOMETERS

UV-VISIBLE SPECTROPHOTOMETER

Elemental Analyses by ICP-AES

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Using the Spectrophotometer

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

3 - Atomic Absorption Spectroscopy

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

SPECTROSCOPY. Light interacting with matter as an analytical tool

Lab #11: Determination of a Chemical Equilibrium Constant

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Application Note: Absorbance

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Experiment #5: Qualitative Absorption Spectroscopy

Simplicity. Reliability. Performance

Upon completion of this lab, the student will be able to:

Raman spectroscopy Lecture

Reaction Stoichiometry and the Formation of a Metal Ion Complex

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Clinical Laboratory Instrumentation

2 Spectrophotometry and the Analysis of Riboflavin

SPECTROPHOTOMETRIC MEASUREMENTS TECHNIQUES FOR FERMENTATION PROCESS BASE THEORY FOR UV-VIS SPECTROPHOTOMETRIC MEASUREMENTS

Ultraviolet Spectroscopy

Chem 131A: Absorbance of Riboflavin

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

where h = J s

73 Series Spectrophotometers

Project 2B Building a Solar Cell (2): Solar Cell Performance

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)

JASCO. FP-6000 Series Spectrofluorometer. Fluorescence Spectrophotometer

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors

UV-Vis spectrophotometers

Raman Spectroscopy Basics

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

UV-VIS-NIR Cary 4000, 5000, 6000i Spectrophotometers Preliminary Performance Data

UV-Visible Spectroscopy

Time out states and transitions

Introduction to flow cytometry

Chemistry 102 Summary June 24 th. Properties of Light

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

DNA quality: electrophoresis, spectrophotometry and fluorometry

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

The Measurement of Sensitivity in Fluorescence Spectroscopy

Quantitation of Peptides and Amino Acids with a Synergy HT using UV Fluorescence

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

INTERNATIONAL OLIVE COUNCIL

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

HUMBOLDT-UNIVERSITÄT ZU BERLIN MATHEMATISCH-NATURWISSENSCHAFTLICHE FAKULTÄT I

Spectral Measurement Solutions for Industry and Research

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

Introduction to Fourier Transform Infrared Spectrometry

2 Absorbing Solar Energy

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

Lecture 1: Basic Concepts on Absorption and Fluorescence

Measuring Protein Concentration through Absorption Spectrophotometry

UV-VIS VARIAN, INC. Cary 100/300 UV-Vis. S p e c t r o p h o t o m e t e r s

5.33 Lecture Notes: Introduction to Spectroscopy

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Anna Serdyuchenko, Victor Gorshelev, Mark Weber John P. Burrows University of Bremen, Institute for Environmental Physics

The Phenomenon of Photoelectric Emission:

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Molecular Spectroscopy

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Powerful Analytics based on Modern Spectrometers

OLIVÉR BÁNHIDI 1. Introduction

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

UV/VIS Spectroscopy. Summary. Contents

DMA-80 Direct Mercury Analyzer

A Beer s Law Experiment

Chemical analysis service, Turner s Green Technology Group

Concepts, Instrumentation and Techniques in Atomic Absorption Spectrophotometry

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

Light as a Wave. The Nature of Light. EM Radiation Spectrum. EM Radiation Spectrum. Electromagnetic Radiation

How to measure Chlorophyll-a

Spectrofluorophotometer

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

Blackbody Radiation References INTRODUCTION

Fig.1. The DAWN spacecraft

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Transcription:

MCAL Spectrophotometry Instruments include: Cary 50 UV-vis Spectrophotometer Eclipse Spectrofluorometer HPLC Diode Array and Fluorescence ICP-OES with CCD detection Spectrophotometry The instruments all have in common that they use the absorption or emission of light, in the form of electromagnetic radiation (EMR) as a means of measuring the presence and/or concentration of material in a solution. 1

Cary 50 and Eclipse Cary 50 Spectrophotometer Mainly used to measures concentration of an analyte in solution Concentration based on absorption of light (incident minus final light beam) by analyte (Beer-Lambert law) at specific wavelength Need standards due to different extinction coefficients of different analytes. 2

Concentration Based on Beer s Lambert Law that concentration is proportional to the absorption of certain energy in the form of light A(absorbance) = εcd ε = extinction coefficient (constant for each compound) d = path length of cuvette =1cm c = concentration of analyte Cary 50 Uv-Vis spectrophotometer Detector diodes Mirrors Cuvette holder Grating Beam splitter Xenon light 3

Grating Scan Grating motor 4

Varian Cary 50 UV-Vis spectrophotometer Dual beam (split beam), Czerny-Turner monochromator, 190 1100 nm wavelength range, approximately 1.5 nm Lamp full spectrum Xe pulse lamp single source quartz overcoated optics, room light immunity, central control by PC with Windows interface. Grating holographic, 27.5 x 35 mm, 1200 lines/mm, blaze angle 8.6 at 240 nm Beam splitting system Detectors 2 silicon diode detectors. Czerny-Turner monochromator 5

Xenon Lamp Xenon Flash Lamp Advantages The maximum scan rate is 24,000 nanometers (nm) per minute. Scan190 1100 nm in less than 3 seconds. Measure samples up to 3 Abs The Xenon lamp has a very long lifetime 3 x 10 9 flashes Room-light immunity 6

Photosensitive Sample Uv-Vis Experiment The analysis involves solving a set of simultaneous equations which describe the absorbance behavior of a mixture of vitamins; B 1 (thiamine) and B 6 (pyridoxine) at different wavelengths. The number of equations, and likewise the number of wavelengths, equals the number of components in the mixture 7

Scan of Vitamin B 1 and B 6 B 6 B 1 Simultaneous Equations Mixture of B 1 and B 6 : A 245 = ε B1(245) C B1 + ε B6(245) C B6 A 290 = ε B6(290) C B6 + ε B1(290) C B1 8

Spectrofluorometer Mainly used to measure the concentration of fluorescing compounds. Advantage - high sensitivity Disadvantage - low number of compounds fluoresce But - can make compounds fluoresce by binding a fluorescent compound Motors Grating ample holder Gr Dr Filte Xenon lamp Detector photomultiplier 9

Emmission monochromator Excitation monochromator Gratings Sample PMT Reference PMT Xenon lamp Beam splitter Sample holder (cuvette) 10

Emission Scan Eclipse Spectrofluorometer 250 200 Intensity (a.u.) 150 100 50 0 300 400 500 600 Wavelength (nm) HPLC with Diode Array Detector Fluorescence detector Diode Array Detector 11

Diode Array The diode array uses a broad emission light source two diode arrays and dual-pathlength flow cells. All the light is allowed to pass through the sensing cell and subsequently the light is dispersed by means of a holographic grating and the dispersed light allowed to fall on an array of diodes. Diode Array 12

Diode Array The light (photons) generated electric charge carriers discharges the diode capacitor The amount of charge needed to recharge capacitors is proportional to number of photons detected by each diode, which is proportional to light intensity. HPLC Experiment Identification of unknown compounds by their retention time. Determination of concentration by use of 1) external standard curve, 2) internal standard or standard 3) or standard addition. 13

Four view display shows the chromatogram, 3D, absorbance and spectrum plots Cary 50 Scan Caffeine 204 273 14

140,000 135,000 130,000 125,000 120,000 115,000 110,000 105,000 100,000 95,000 90,000 85,000 80,000 75,000 70,000 65,000 60,000 55,000 50,000 45,000 40,000 35,000 30,000 25,000 20,000 15,000 10,000 5,000 0-5,000 µv TH4 mix 11_11_17_2011 3_19_57 PM.DATA [STAR 800-363] -10,000 RT [min] 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 9/24/2015 Diode Array Screen Quinine and Caffeine Fluorescence detection Exc λ = 347, Em λ = 448 Quinine rt = 12.1 42 mau TH4 mix 11_11_17_2011 3_19_57 PM.DATA [335 Ch 2 ] 40 38 36 Uv detection λ = 213, 273 34 32 30 Caffeine 28 26 24 rt = 9.6 22 20 18 16 14 12 10 8 6 4 2 0-2 -4-6 RT [min] 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 15

HPLC Experiment - Light Sources Fluorescence detector uses Xenon lamp which has wavelength region of 250-600 The HPLC Diode Array uses two lamps a deuterium lamp with wavelengths from 160 to 380 and tungsten halogen lamp which covers wavelengths from 240 to 2500. HPLC Experiment Concentration Determined by External Standard EXTERNAL STANDARD 6 5 4 AREA 3 2 1 0 0 2 4 6 8 10 12 CONCENTRATION 16

700-ES Series Simultaneous ICP s ICP-OES Experiment Determine the mineral content of solid samples of: Grains Mining rock Water Feeds and foods Surfaces 17

Radial Plasma Central Channel Fireball Viewing Volume Viewing Height Work coil Spraychambers Sturman-Masters Aerosol to Torch -double pass Glass Cyclonic - smaller volume To Plasma Sample Inlet Sample Flow Pump to Drain To Drain 18

Need source of excitation Need way of measuring light emission Varian Simultaneous ICP Optics Detector Chip Prism Crossdisperser Echelle Grating Light from Plasma 19

Echelle Grating 20

Varian Simultaneous ICP Optics Torch Detector Chip Echelle Grating Prism Crossdisperser 720-ES Series CCD Detector 21

VistaChip CCD detector The CCD (charge coupled device) 70 000 pixels, arranged to exactly match the two dimensional image from the echelle optics. continuous wavelength coverage from 167 785 nm. trace and major concentrations can be measured simultaneously, 22

Motor Mirror 23

720-ES Series CCD Detector Order 88 167 nm Order 19 785 nm 24

Axial verses radial torch sensitivity ICP Experiment Determination of mineral content in commercial products (product labelling, nutrient requirements, mining). Dry ashing of sample Burns off organic material leaving ash (minerals) Acid digestion of sample Dissolves minerals or can dissolve total sample including organic material (wet ashing) Concentration determined by external standard,standard addition, and internal standard. 25

Concentration of unknown Standard Addition 0.5 2621.76 1 4633.48 1.5 5991.37 7000 6000 5000 4000 Intensity 3000 2000 1000 0-1.5-1 -0.5 0 0.5 1 1.5 2-1000 -2000-3000 Concentration EXTERNAL STANDARD 6 5 EMMISSION 4 3 2 1 0 0 2 4 6 8 10 12 CONCENTRATION 26