NIR Chemical Imaging as a Process Analytical Tool



Similar documents
In this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging

Multivariate Chemometric and Statistic Software Role in Process Analytical Technology

Quality by Design Approaches to Analytical Methods -- FDA Perspective. Yubing Tang, Ph.D. FDA/CDER/ONDQA AAPS, Washington DC October 25, 2011

Chemometric Analysis for Spectroscopy

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Qualitative NIR Analysis for Ingredients in the Baking Industry

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Spectral Measurement Solutions for Industry and Research

Pharmaceutical Quality Systems: US Perspective

Multivariate Tools for Modern Pharmaceutical Control FDA Perspective

Automotive Applications of 3D Laser Scanning Introduction

Back to Basics Fundamentals of Polymer Analysis

LabRAM HR. Research Raman Made Easy! Raman Spectroscopy Systems. Spectroscopy Suite. Powered by:

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

PARTICLE SIZE. By: Philo Morse, MS, and Andrew Loxley, PhD. INTRODUCTION are not as stringent as for scattering techniques.

The importance of normalisation when comparing tablet properties

LabRAM HR Evolution. Research Raman Made Easy!

Industrial Process Monitoring Requires Rugged AOTF Tools

O2PLS for improved analysis and visualization of complex data

Cytell Cell Imaging System

FT-IR Microspectroscopy in Forensic and Crime Lab Analysis

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT

Asian Journal of Food and Agro-Industry ISSN Available online at

MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers

Method Development and Validation for Particle Size and Shape Measurements

Process Analytical Technology (PAT) Capabilities and Implementations under QbD Principles QbD and PAT Department

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

Potential use of handheld Raman devices as tools for screening medicines for quality

Visualization methods for patent data

The identification of tablets and capsules containing barbiturates by MATR infrared spectroscopy

1 Laboratory #5: Grating Spectrometer

Fig.1. The DAWN spacecraft

h e l p s y o u C O N T R O L

11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

How Landsat Images are Made

LC-MS/MS for Chromatographers

Guideline on Process Validation

Chapter Test B. Chapter: Measurements and Calculations

Fusion Pro QbD-aligned DOE Software

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Product Range Overview

INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING

NIRCal Software data sheet

WATERS QUANTITATIVE ANALYSIS solutions

SIMCA 14 MASTER YOUR DATA SIMCA THE STANDARD IN MULTIVARIATE DATA ANALYSIS

Spectrum 10 Spectroscopy Software

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Applications. Blue IF 039, Green IF 062, Yellow IF 022, Orange IF 041, Red IF 090,Dark Red IF 091 IR pass IF 092, IF098, IF 093 Surface 1 5/2 0.

TABLET ROUGHNESS INSPECTION WITH 3D PROFILOMETRY

Big Data: Rethinking Text Visualization

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Enhancement of Breakdown Strength and Energy Density in

Measurement & Analytics Measurement made easy

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

Uses of Derivative Spectroscopy

Investigation of Solid-Phase Peptide Synthesis by the Near-Infrared Multispectral Imaging Technique: A Detection Method for Combinatorial Chemistry

GIANT FREQUENCY SHIFT OF INTRAMOLECULAR VIBRATION BAND IN THE RAMAN SPECTRA OF WATER ON THE SILVER SURFACE. M.E. Kompan

Combinatorial Chemistry and solid phase synthesis seminar and laboratory course

MetaMorph Software Basic Analysis Guide The use of measurements and journals

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Theremino System Theremino Spectrometer Technology

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

Validation and Calibration. Definitions and Terminology

M.Sc. in Nano Technology with specialisation in Nano Biotechnology

Experiment #5: Qualitative Absorption Spectroscopy

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

A novel method for the synthesis of peptides

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Workshop B Control Strategy

Realization of a UV fisheye hyperspectral camera

Engineering Standards Advance PAT

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

Implementing New USP Chapters for Analytical Method Validation

Digital Remote Sensing Data Processing Digital Remote Sensing Data Processing and Analysis: An Introduction and Analysis: An Introduction

Guidance for Industry

Zeiss 780 Training Notes

APPENDIX N. Data Validation Using Data Descriptors

Measuring of optical output and attenuation

5.3 Cell Phone Camera

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

MiSeq: Imaging and Base Calling

Monitoring and Control Tools for Implementing PAT

16 th IOCCG Committee annual meeting. Plymouth, UK February mission: Present status and near future

2.3 Spatial Resolution, Pixel Size, and Scale

SSO Transmission Grating Spectrograph (TGS) User s Guide

ON-LINE ANALYSIS - WHAT HAS BEEN DONE? Mr P de Waal Blue Cube Systems (Pty) Ltd

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Transcription:

NIR Chemical Imaging as a Process Analytical Tool NIR chemical imaging greatly extends the capability of NIR spectroscopy, and is the only PAT-applicable blend monitoring technique that gives both statistical and direct information about individual sample components on the micro scale. By E Neil Lewis, Linda H Kidder and Eunah Lee at Spectral Dimensions, Inc Dr E Neil Lewis received a PhD in Chemistry from the Polytechnic of Wales in the UK, and did a postdoctoral fellowship at the National Institutes of Health (NIH) in the Laboratory of Chemical Physics in the USA. He was tenured by the NIH in 1992 and subsequently held the position of Senior Biophysical Researcher. In 1999, he left to lead a new effort as a Founder and President of Spectral Dimensions, Inc, a company that develops and manufactures infrared chemical imaging systems. He is the author of a number of patents and has published over 60 peer-reviewed scientific papers and book chapters on the subject. He is the recipient of numerous awards including: the Meggers Award in 1992 and 1994, presented by the Society of Applied Spectroscopy; the Heinrich award in 1995, presented by the Microbeam Analysis Society for Outstanding Young MAS Scientist; the Outstanding Contribution to the Physical Sciences award in 1997, presented by the Washington Academy of Sciences; and the 2004 Williams-Wright Award presented by the Coblentz Society. Dr Linda Kidder graduated from Williams College with a BA in Chemistry, and received a PhD in Physical Chemistry from the Johns Hopkins University, where she was the recipient of the Sonneborn and Ernest Marks Fellowships. Her career in spectroscopic imaging began during her post-doctorate at the NIH, working with Neil Lewis in the Laboratory of Chemical Physics. Dr Kidder is a co-founder of Spectral Dimensions, and has been with the company since its inception. She currently holds the position of Vice President of Operations. Eunah Lee received a PhD in Physical Chemistry from Syracuse University in New York, researching Raman optical activity and transition current density. This was followed by a post-doctoral appointment studying high pressure Raman spectroscopy at Urbana-Champaign. She joined Spectral Dimensions in 2001 as an Applications Scientist; her main role has been to develop data-processing strategies and protocols for novel applications of NIR Chemical Imaging, with a particular emphasis on pharmaceutical applications. Innovations in Pharmaceutical Technology issue 17. Samedan Ltd. 2006 While it is generally assumed that the manufacturing steps performed to transform a collection of raw materials into a finished pharmaceutical product significantly impact manufacturability and product performance, an understanding of these phenomena seem to be either illusive or even worse neglected. In fact, it has led some sources to label the apparently simple process of dry-blending pharmaceutical ingredients as a black art or even alchemy (1). A chief reason why this process is not well-characterised is the lack of analytical technology capable of delivering detailed information of the blending process at both the macro- and micro-scale. In addition to providing blending data for all components active pharmaceutical ingredients (APIs) and excipients alike an ideal technique would also perform these measurements in real-time and non-invasively that is, without having to remove sample from a blend vessel. The accepted standard in the industry is currently to perform HPLC on samples that have been removed from the vessel. This approach is time-consuming and not considered to be compatible with US FDA Process Analytical Technology (PAT) regulations (2), as it does not provide an understanding of the blending process it simply gives an assessment of whether or not an end-point has been reached with respect to the bulk distribution of the active ingredient. Non-wet chemistry approaches that may be appropriate for PAT are being evaluated by the industry, including near-infrared (NIR) chemical imaging, single point NIR spectroscopy, acoustic spectroscopy and effusivity. Except for NIR chemical imaging, these alternative techniques can only deliver data on macro-scale blending characteristics, as they track only average mixing

Figure 1: The typical data construct for chemical imaging the hypercube The data is shown as a series of wavelength-resolved images and spatially resolved spectra (1a). An image at a single wavelength (1b) has contrast based on the strength of the spectral features at that wavelength. Areas of the sample that have a relatively weak spectral signature will appear dark, and areas that have a strong spectral feature at that wavelength will appear bright. The spectra in 1c correspond to individual spatial regions of the sample. a b c 3 2 y axis, k wavelengths Normalised Intensity 1 0-1 λ axis, m pixels 2mm -2 1,200 1,400 1,600 1,800 2,000 2,200 2,400 Wavelength (nm) χ axis, n pixels progress, and cannot monitor the micro-mixing characteristics and domain sizes of individual components. NIR chemical imaging, though, can provide quantitative information about both the spatial and chemical characteristics of individual blend components at the micro scale. As such, it can be utilised to elucidate domain sizes and spatial distributions of both the API and excipients simultaneously. It is the only method of those considered to be relevant to PAT that is a primary technique that is, it does not need to be correlated with other physical properties, or results from other methods. NIR CHEMICAL ANALYSIS A typical NIR chemical imaging instrument collects many thousands of spatially distinct NIR spectra simultaneously in a single data-set. These spatially resolved data can be acquired over a microscopic or macroscopic portion of a sample, and provide qualitative and quantitative insight into the functionality of heterogeneous samples such as pharmaceutical tablets, polymer laminates, or agricultural and biological materials. First commercialised five years ago, NIR chemical imaging is a relatively new addition to the analytical toolbox; however, its demonstrated utility in solving real-world problems has encouraged its rapid acceptance. Currently, NIR chemical imaging instrumentation is predominantly deployed in laboratory settings for product development and formulation R&D, and as a trouble-shooting tool for manufacturing. Because it builds on the analytical capabilities of NIR spectroscopy, it is a well-understood and well-characterised tool, and the underlying physical principles of how and why it works are fully established and accepted. It retains many of the attributes of traditional NIR bulk spectroscopy such as minimal sample preparation, flexible sample presentation, robust and easy-to-use instrumentation, and rapid data acquisition. It can also get around some of the more tricky aspects of NIR spectroscopy such as the need for calibration sets and transfer of calibration between instruments. Although novel analytical techniques tend to begin their life cycle viewed as more of an art form than a science, the most useful and robust techniques do move into the mainstream. NIR imaging has made that transition and is deployed in a variety of industrial settings elucidating novel critical product performance attributes. Although novel analytical techniques tend to begin their life cycle viewed as more of an art form than a science, the most useful and robust techniques do move into the mainstream. NIR imaging has made that transition and is deployed in a variety of industrial settings elucidating novel critical product performance attributes. In addition, by providing robust, reliable and automated data collection capabilities, coupled tightly with quantitative, statistical, objective, reproducible and automated data processing tools, NIR chemical imaging has moved rapidly from a specialised technology into a routine and highly desirable quantitative analytical tool. Robust instrumentation, modular software that enables

the development of turnkey solutions and instrument platforms that transition from R&D to process environments are just some of the attributes that contribute to the usefulness of NIR chemical imaging as a routine QA/QC tool. Current developments in chemical imaging have focused on the implementation of numerical strategies, algorithms and routine software tools to automate data-mining and enable turnkey analytical solutions to be developed. INSTRUMENTATION AND DATA COLLECTION PROTOCOL The basic data construct for global spectroscopic imaging systems is shown in Figure 1a. The data-set, commonly referred to as a hypercube, consists of a sequence of images of a sample recorded over a series of infrared wavelengths or frequencies. The data can be viewed as a collection of frequency-resolved images (see Figure 1b) or as a spectroscopist would view it a series of spatially resolved spectra (see Figure 1c). The chemical image in Figure 1b is that of a whole tablet, demonstrating a field of view (FOV) of approximately 13 x 10mm. In this example, because the full data-set contains 81,920 spectra, a single micro-spectrum samples a location on the tablet surface of approximately 40x40 microns. This magnification is configurable, and can be increased or decreased by the simple selection of the appropriate image formation optics. a b Figure 2: NIR chemical images of a 50:50 API/excipient model pharmaceutical blend The images 2a, 2b and 2c show the blend progress at three blending-times: 3, 6 and 10 seconds respectively. The API appears as red domains and the excipient appears as blue areas in the image. The image is a single channel image from the data-set at 1632nm, where there is a significant spectral difference between the API and excipient. To create a hypercube, data can be collected one image at a time, one spectrum at a time or one line image at a time. However, not all of these approaches are relevant for process instrumentation. Building up a data-set through point- or line-mapping which are both mechanically-driven scanning approaches does not afford the speed necessary for process monitoring applications. In addition, because of the delicate moving parts, they are not as rugged an instrumental approach as global imaging. Furthermore, some of the unique capabilities of global imaging such as the ability to have standards or pure components in the same field of view as the sample are negated with the point- and line-mapping approaches. Global imaging using a solid state tunable filter and focal plane array a common approach to NIR imaging is currently the only approach relevant to process applications. Below, we describe a specific focal plane/tunable filter approach that provides a no-moving parts, solid state and rugged instrument platform. c IMAGING OF BLEND PROGRESSION As an example of the qualitative and quantitative information that NIR chemical imaging can provide for pharmaceutical blending, we present a simple example a 50:50 blend of lactose and an active pharmaceutical ingredient (API). NIR spectral information can be used to produce images that visualise the abundance, distribution and domain size of the API within the lactose matrix. The images reveal the extent of the blending at each time interval. Data was processed by taking a second derivative and normalising the results. Figure 2 shows

Figure 3: Histogram representations of the corresponding images in Figure 2 Figures a-c correspond to the 3-6- and 10-second blend images, respectively. a b c -0.2-0.1 0 0.1 0.2 0.3-0.2-0.1 0 0.1 0.2 0.3-0.2-0.1 0 0.1 0.2 0.3 Intensity at 1,632nm Intensity at 1,632nm Intensity at 1,632nm Table 1: Statistical analysis of the image data shown in Figures 3a to 3c 3 seconds 6 seconds 10 seconds Mean value -0.0332-0.0357-0.0301 Standard deviation 0.048 0.042 0.036 Skew 1.944 1.648 1.522 Kurtosis 5.882 5.565 5.698 NIR chemical images of this model pharmaceutical blending process at the three blending-time intervals: 3, 6 and 10 seconds respectively for 2a, 2b and 2c. The contrast in these images is based on the strong API feature (red domains) relative to lactose (blue background) at 1632nm. Looking at these images, an observer could make several subjective observations; the API domain sizes appear to decrease with increased blending time, and also appear to become more homogeneously distributed. However, for a technique to be useful in a process monitoring application or any analytical application the results obtained must be objective, reproducible, automated and quantitative. NIR chemical imaging is able to do this. One approach for deriving numerical information is to represent image data as histograms, enabling statistical and objective analysis of the images. Figures 3a-3c show the histogram representation of the 3, 6 and 10 second blend images, respectively. Table 1 summarises the resulting statistical analysis. Qualitatively, the brighter the pixel, the more similar it is to API, and these pixels appear to the right on the x-axis. The more homogeneously the API is distributed, the narrower the distribution will be. The standard deviation values in Table 1 decrease with increased blending time, verifying that the blend is becoming more homogeneous that is, the distribution of pixel intensities is becoming narrower, and the bulk of pixels are becoming more similar to each other. population of pixels with high API content. As the skew decreases with blending time, it means that these high API content domains are mixing with lactose and moving toward a mean blending value. The final category in the table, kurtosis, is a measure of the peakedness of a distribution, or alternatively the size of the tails. A large positive number indicates that the distribution tails are large, implying that a significant population of pixels does not lie close to the mean. There is no trend relating kurtosis and blending time, although the 6- and 10-second values are lower than the 3-second value. In other words, although we can see progress of mixing in the overall homogeneity based on standard deviation and skew values, there are still noticeable domains of API present in the mixture. This is visualised in the images, where API-rich domains are still readily apparent after 10 seconds of blend time. It is worth noting here that other methods for monitoring pharmaceutical blending produce a single average value for the composition at any given Figure 4: A schematic representation of the spatial distribution of two components present in a 50:50 proportion as blending progresses Red and yellow squares show domains of API and excipient, and orange squares indicate domains of mixed API and excipient. As blending progresses, the mixture evolves from isolated domains of pure API, to smaller yet still distinct API domains, and ultimately to a purely homogeneous distribution of API and excipient. A positive skew indicates that the tail on the right side of the distribution is longer in this case, representing a

measurement point. From these data distributions, it is obvious that the average value (centre of the distribution) is only one measure of the state of the blend and the range of states reflected in the distribution width is also critically important. A schematic representation of six different blends all with 50% API is shown in Figure 4. Red and yellow squares show domains of API and excipient, and orange squares indicate domains of mixed API and excipient. As blending progresses, the mixture evolves from isolated domains of pure API domains, to smaller yet still distinct API domains, and ultimately to a purely homogeneous distribution of API and excipient. The overall brightness of these images moves towards a mean represented by the orange squares. Obviously, the definition of a homogeneous pixel is also a function of magnification. If the image is broken down into even smaller pixels, orange regions may appear as a collection of solid red and yellow pixels again. Interestingly, a bulk approach such as HPLC would discern no difference between these six blends. And in most circumstances, the extreme variation in homogeneity between these blends would directly influence physical characteristics such as dissolution. The ability to characterise the heterogeneity of a sample is what distinguishes NIR chemical imaging, and makes it such a valuable analytical tool. PROCESS INSTRUMENT PROTOTYPE A prototype NIR chemical imaging blend monitor mounted to a V-blender is shown in Figure 5. This implementation is an LCTF-based global imaging system, in which an imaging fibre bundle is used to collect and transmit NIR spectral information from the blend to the NIR imaging spectrometer. The same type of data analysis that has been demonstrated in this article can be performed with this system. Its utility for blend monitoring in a process environment is currently being evaluated. Further development to simplify the implementation, streamline data acquisition and turnkey data analysis is underway. CONCLUSION NIR chemical imaging is the only PAT technique currently being considered for blend monitoring that gives both statistical and direct information about individual sample components on the micro scale. It has evolved from being a specialised laboratory-based analytical technique providing mostly qualitative assessment of sample heterogeneity into a robust process-ready technique that provides reliable quantitative data derived directly or indirectly, from single or multiple samples. Today, NIR chemical imaging is being used to measure spatial heterogeneity and component distribution in powder blends, and make direct measurements of coating thickness, particle sizes and associated distribution statistics in complex multi-component samples. In addition, it is being used to locate and identify contaminants in single or multiple samples, and perform conventional NIR spectroscopy in a high-throughput modality. All of this is being accomplished using both microscopic and macroscopic optics on samples that differ in size by several orders of magnitude. The authors can be contacted at nlewis@spectraldimensions.com References 1. The Art and Science of Formulation Development: A CRO s Perspective, Paul Stach, AAPS News Magazine, 20-22, May 2004. 2. PAT A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance, United States Food and Drug Administration, September 2004. Figure 5: A prototype NIR chemical imaging blend monitor mounted to a V-blender