Reticulation sewers in basements Technical guidelines



Similar documents
Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

SECTION GRAVITY SANITARY SEWERS

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

SANITARY SEWER SPECIFICATIONS

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

SECTION STORM DRAINAGE TABLE OF CONTENTS

Policy 11: Land Development Guidelines

PART 5 : WASTEWATER DRAINAGE

Jay R. Smith Mfg. Co.

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

Hanson Building Products. precast basement solutions

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

SECTION FACILITY STORM DRAINAGE PIPING

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

GUERNSEY OIL INSTALLATION GUIDELINES

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Top 10+ Mistakes of DWV plumbing design

Residential Deck Safety, Construction, and Repair

Building over or close to a public sewer

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Excerpts from the Canadian National Building Code (NBC)

16. Storm water drainage

Chapter 3 Pre-Installation, Foundations and Piers

See Appendix A for additional information, or contact ASTM directly.

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

OAR52 A-1 (September, 1981)

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

2010 Residential Water Heater Replacement Check List

Standard Specification for the Laying of Sewer Lines and Appurtenances in the Hurunui District

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Annex B

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Section SEWER PIPE INSTALLATION AND TESTING

Walking and Working Surface Checklist:

PMA ONLINE TRAINING Venting for Plumbing Systems

REPAIRS TO DAMAGED SEWERS

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Guide to working on Public Sewers

Saferand easierinstallation

DIVISION 4300 STORM DRAINAGE

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

Couplings. Drain Couplings Standard Couplings Large Diameter Couplings Adaptor Couplings Flexible Saddles Bushes

Prepare a drainage system layout and specification notes for a low- rise building.

Elevating Your House. Introduction CHAPTER 5

Current as of 11/10/08 1 of 1

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

Uncovered Decks & Porches

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

Why Do I Have Sewer Smells In My Home or Business?

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Separation of common services (above and below ground) INDUSTRY BULLETIN. Background. Separation distances. Proximity of services below ground

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

2006 Codes. Please verify the following before calling for inspection

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Guidelines for closed circuit television (CCTV) inspection of newly constructed sewers

Element D Services Plumbing

SMITH MFG. CO. PROTECT YOUR INVESTMENTS. Automatic Backwater Valve SMITH MORRIS GROUP INTERNATIONAL.

WATER SERVICES ASSOCIATION OF AUSTRALIA WATER SUPPLY CODE OF AUSTRALIA

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Puddle Flange. FRANK Puddle Flange

Gas Meter Clearances and Service Installation Requirements

Underground Service Requirements and Instructions

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition

GUIDELINES FOR DESIGNERS BUILDING AND CONSTRUCTION WORKS WITHIN PROXIMITY TO CORPORATION SERVICES

Fall protection systems and practices Duty to have fall protection Protection at or above 6' level.

Plumbing for retail food businesses

Residential Plumbing BCN 1058

INDEX. Sec. No. Items Page Nos.

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

UltraTech International, Inc. Canadian Secondary Containment Requirements

- 5 - Table1. Maximum Compartment Volumes

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Standard terms and conditions

3A General Information A. Concepts... 1 B. Conditions... 1

SECTION GROUND WATER STORAGE TANKS

Self-Home Inspection Checklist

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Residential Inspection Guidelines

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Connex. Mortarless Masonry Block System

Transcription:

Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to reticulation sewers ranging from DN150 to DN225. We will accept works that observe these guidelines. Previous inadequate practices must discontinue. Who Developers, architects, hydraulic services consultants, engineers, Water Services Coordinators and designers. Why The aim is to avoid internal sewer surcharges by improving the planning, design and construction of sewers in basements. Document current at 29 April 2015 Page 1

Contents 1 Introduction 3 2 Planning 3 2.1 Hydraulics and servicing options 3 2.2 Building layout 3 2.3 Access to pipe 3 2.4 Pipe alignment 4 2.5 Separation from other services 4 2.6 Maintenance structures 4 2.7 Property connection 4 2.8 Structural independence 5 2.9 Future connections 5 3 Pipework 5 3.1 Pipes and fittings 5 3.2 Pipe support 5 3.3 Maintenance structures 5 3.4 Protection from damage 6 3.5 Vehicular barriers 6 3.6 Penetration 6 3.7 Labelling 6 3.8 Acceptance testing 6 Figure 1 Illustration of ground floor layout... 7 Figure 2 Example of future connection provision... 8 Figure 3 Basement wall pipe penetration details... 9 Document current at 29 April 2015 Page 2

1 Introduction Sydney Water currently allows reticulation sewers to be laid in building basements. This often restricts operation and maintenance access. There have also been a number of surcharge incidents that have disrupted services and damaged property. This is often due to unsympathetic building layout, inadequate design and substandard workmanship. The Sydney Water edition of WSA 02 Sewerage Code of Australia applies to reticulation sewers. These technical guidelines outline how the code can be adapted and applied inside a building basement. We will accept works that observe these guidelines. This document covers reticulation sewers of size from DN150 to DN225 laid within building basements. Sewers larger than DN225 are generally not allowed in basements without our approval. 2 Planning 2.1 Hydraulics and servicing options We will only accept a basement sewer proposal if you can demonstrate that there is no other suitable servicing option, such as relaying the existing sewer outside the building footprint or outside the property boundary. The capacity of an existing sewer may not be sufficient for future growth. In this case, the new sewer must be re-sized to convey the forecast peak flow from its catchment area, assuming the area is fully developed according to the current and planned land-use zoning. The latest Sewerage Flow Schedule tool must be used to estimate the flow, and size and grade the new sewer. The latest tool can be downloaded from the Sydney Water website. 2.2 Building layout Sewers may surcharge due to blockage or heavy wet weather. Surcharges can cause obnoxious smells, property damage and possible personal injury. Your building plan must recognise the need to design out these undesirable consequences. An example of a well-planned ground floor building layout is shown in Figure 1. The alignment and reduced levels of the sewer are restricted and dictated by the hydraulics of the gravity flow. It is usually not possible to retrofit the sewer onto a floor plan without either compromising the intended floor use or reducing sewer performance. 2.3 Access to pipe The sewer pipe and all its appurtenances must be fully visible. Access must not be obstructed by walls, beams and columns. The clearance between the external wall of the sewer pipe and any obstructing surface must be at least 150 mm. You must provide a passageway to the pipe which is safe and unobstructed at all times for Sydney Water maintenance staff carrying light equipment. You must provide us with an acceptable 24-hour access arrangement. Document current at 29 April 2015 Page 3

2.4 Pipe alignment The sewer should take the most direct route possible with minimum changes in direction. The corridor occupied by the sewer must be clear of obstructions to maintain the required uniform grade. Any change in direction should preferably occur at a maintenance structure. In other cases, we will only allow it to be within 50 m of a maintenance structure, with no bends in between. The sewer must not have short radius bends of over 45 o. Any greater change in horizontal direction must be made using multiple bends. 2.5 Separation from other services The line of the sewer must be clear of other services that may damage or obstruct inspection of the pipe. Any electrical supply cable, gas pipe or water services must be at least 300 mm away. Services crossing the sewer must have minimum clearance of 150 mm under or above the pipe. The sewer must not be directly above any drinking water or fire sprinkler tanks, or their associated pumping installations. The sewer must not be located inside air plenums. 2.6 Maintenance structures Maintenance structures must be provided for visual or CCTV inspection and for drain clearing. The distance between maintenance shafts (MSs) must not be over 120 m. The shaft of these structures must be raised to the proposed ground floor level. Unless you have our approval, the access cover must not be lower than the original ground level before development. These structures should be positioned so that any surcharge is easily visible and will drain away from the building. They should not be in habitable areas or where property damage is likely during surcharge events. The access covers of these maintenance structures must be readily accessible. A standing space for vehicles carrying jetting hoses or CCTV cameras must be available within 50 m of each cover. We require a clear unobstructed passageway (minimum 1 m wide and 2.4 m headroom) for staff and equipment to reach the maintenance structures. Maintenance holes must have a clear, unobstructed working space of at least a metre around the rim of the covers and at least 2.4 m headroom above. For maintenance shafts, the space may be reduced to 600 mm around the rim of the covers. We may require you to install additional maintenance holes (MHs) or maintenance shafts (MSs). You must talk to us before finalising the building layout. 2.7 Property connection The property or the plumbing stack must connect at a maintenance structure. The point of property connection must be shown in your submitted drawings. To avoid potential sewer surcharge for sanitary fixtures in basements, they must be connected to the sewer through a pumping installation, in accordance with the requirements of AS 3500.2 and the Plumbing Code of Australia. Document current at 29 April 2015 Page 4

2.8 Structural independence The sewer and its associated structures must be attached to, or supported by the building. It must not be fully or partially enclosed inside any building elements, such as beams, walls or slabs. 2.9 Future connections We may require you to provide for connections to any future upstream or downstream sewers. The installed pipe stub must be in line with and at the grade of the sewer. Your submitted drawing must show the position and invert level of the pipe stub. An example of this is shown in Figure 2. 3 Pipework 3.1 Pipes and fittings Pipes and fittings must be: ductile iron pressure pipes complying with the requirements of AS 2280:2012 or cast grey and ductile iron non-pressure pipes, with Watermark certification, complying with the requirements of AS 1631-1994. Joints must be elastomeric-ring or bolted gland joints. All pipes and fittings must be, as a minimum standard, externally coated with cold-applied bitumen, and internally lined with calcium aluminate cement or a polymeric lining suitable for use in a sewage environment. You must not use pipe fittings with access doors or hatches, as they can present a potential flooding hazard when opened in surcharge conditions. 3.2 Pipe support Supports must be designed to take: the load of the water-filled pipe plus 115 kg at each point of support a nominal internal hydrostatic thrust load of 10 m head, or the height from the support to the surcharge relief point, whichever is the greater. There must be at least two supports per pipe barrel length. The spacing of supports must not be over 3 m for both graded and vertical pipes. Additional supports must be installed at bends, junctions or closing pipe lengths. Pipe supports may be in the form of hook bolts, saddle clamps, rod hangers and cantilever brackets. Lateral restraints must be provided to fix the pipe in steady and firm position without side-sways. They must be made of mild steel with hot-dip galvanised zinc coating complying with AS4680. 3.3 Maintenance structures Maintenance holes must be reinforced concrete structures attached to or supported by the structural members of the building. Precast concrete construction is not allowed. Document current at 29 April 2015 Page 5

Prefabricated PE or PVC maintenance shafts must be encased in concrete. The riser may be in grey or ductile iron. Maintenance shafts may also be made of stainless steel, or other noncombustible and corrosion resistant materials. 3.4 Protection from damage Where the clear headroom of the sewer from the floor is less than 1.8 m, you must have appropriate barriers to prevent mechanical damage caused by floor users. Vehicular barriers must be installed if the sewer is located near parking spaces, driveways or vehicular ramps. 3.5 Vehicular barriers Vehicular barriers must be designed to the following horizontal imposed loadings: 30 kn for light vehicle traffic areas (parking, garages, driveways and ramps restricted to cars, light vans, etc) not exceeding 2,500 kg gross mass. 240 kn for light vehicle traffic at the end of straight ramps over 20 m in length and intended for downward travel. 40 kn for medium vehicle traffic areas (vehicles between 2,500 kg and 10,000 kg). For guardrails, the impact force should be assumed to act at 0.5 m above floor level for light traffic areas and at 1 m for medium traffic areas. 3.6 Penetration Pipes must not be embedded in concrete walls or beams. There must be openings in the structural element for the pipe to pass through, which are at least 150 mm larger than the pipe barrel external diameter. For external walls, the annular space between the opening and the pipe must be sealed against water penetration using an EDPM mechanical seal (See Figure 3). The designer may require an articulated pipe joint, immediately at the buried side of any external wall. 3.7 Labelling The pipework must be labelled with markers complying with the requirements of AS 1345 Identification of the contents of pipes, conduits and ducts. The markers must have: the words Sewer Sydney Water on a black label with a white outer contrasting border an arrow indicating the direction of flow white, uppercase letters at least 28 mm high. Markers must be printed labels made of durable materials and fixed to the pipe wall. They must be placed next to junctions, wall penetrations and the like, and at spacing not greater than 8 m along the pipework. 3.8 Acceptance testing The completed sewer pipe must be tested for leaks either by the vacuum test or pressure test methods, as described in WSA 02 (Sydney Water Edition) Sewerage Code. All maintenance holes and shafts must be tested using the vacuum pressure test method outlined in the code. Document current at 29 April 2015 Page 6

Figure 1 Illustration of ground floor layout Document current at 29 April 2015 Page 7

Figure 2 Example of future connection provision Document current at 29 April 2015 Page 8

Figure 3 Basement wall pipe penetration details Document current at 29 April 2015 Page 9 SW264 04/15 Sydney Water. All rights reserved.