SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial



Similar documents
SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Model #: SMART2200CRMXL

Internet Office 500VA Tower Standby 120V UPS with USB port

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

BC Pro UPS System Standby UPS System

Internet Office UPS System Standby UPS for PCs, workstations and more

Uninterruptible Power Supply

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Tough Decision: On-Line or Line-Interactive UPS?

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course Tripp Lite.

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

MAJORSINE Power Inverter

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

PowerGem Pro Uninterruptible Power Supply

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

R5000 Uninterruptible Power System (UPS) Overview

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Smart-UPS On-Line 230 V

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

R5000 Uninterruptible Power System (UPS) Overview

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Back-UPS Pro 1300/1500 Installation and Operation

Dell Smart-UPS 1,500 3,000 VA

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

LAP ENERGIA PARA DATACENTERS

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Installation and Operation Back-UPS 1250, 1300, 1500

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

USER MANUAL Online UPS 1K/2K/3K Rack

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

VISION UPS UPS PRODUCT CATALOGUE

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

UNINTERRUPTIBLE POWER SUPPLY (UPS)

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

User Manual 1K/2K/3K Online UPS

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

USER MANUAL Online UPS 1K/2K/3K

EKOS Cart. Instructions for Use

Online UPS. PowerWalker VFI 1000R/1U

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Cisco Nexus 7000 Series Power Supply Modules

Technical Data. back-up time in minutes 100% load % load

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Specification Requirements DBL 700MX and 1000MX Series UPS

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

The UPS for the highest security in industry and data centres

How To Use A Power Supply Unit (Upu)

Phase Modular Finally the benefits of Modular ups are for all

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Product Snapshot. Powerware 5125 Family Uninterruptible Power System. Introducing the expanded Powerware 5125 family of UPSs.

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

PE8216/PE8324. Energy Intelligence Solutions

Intersection Preassembled 19-inch Rack

Eaton 93PM UPS Where aesthetics meet intelligence.

User s Manual AURORA 1.2K/2.2K

IBM 11000VA LCD 5U Rack Uninterruptible Power Supply IBM System x at-a-glance guide

User s Manual Before using the inverter, you need to read and save the safety instructions.

HP R12000 and R18000 DirectFlow UPS User Guide

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP 480/277 Volt Solutions. Overview

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Transcription:

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Single all-in-one rack / tower housing installs in only 4 rack spaces (4U) with a maximum installed depth of only 20.7 in. / 52.6 cm. Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional SNMP/Web and contact-closure communications card accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. L6-30P input, plus two L6-30R and two L6-20R outlets. External battery packs are field replaceable and hot swappable. $250,000 connected equipment insurance; Features Highlights 5kVA / 5000VA / 4500W on-line double-conversion UPS; 0.9 power factor 200/208/220/230/240V 50/60Hz output; high efficiency economy mode option 4U Rack/Tower compatible; Hot-swappable batteries USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card options Front panel LEDs with detailed LCD monitoring and control Tripp Lite SU5000RT4UHV 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise 1 / 6 screen Expandable runtime with optional external battery packs NEMA L6-30P input (3 wire); L6-30R & L6-20R outputs Package Includes SU5000RT4UHV UPS System 4 post rackmount rails PowerAlert software and complete cabling

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions L6-30P input plug; 2 L6-30R and 2 L6-20R UPS supported outlets Included rail kit supports 4U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU5000RT4UHV) Optional 2-9USTAND supports upright tower placement (1 required for SU5000RT4UHV) Maximum installed rack depth of only 20.7 in. / 52.6cm inches Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode Corrects brownouts to 156V at full load (100V at 50% load or less) Corrects overvoltages to 290V at full load (300V at 90% load or less) Supports 50/60Hz operation for worldwide frequency compatibility Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network-grade AC surge and noise suppression Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part# RELAYIOCARD) Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED/LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off (EPO) via built-in interface Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement BP192V12-3U external battery packs are field replaceable and hot swappable Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating) $250,000 connected equipment insurance Specifications OUTPUT Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared Output Volt Amp Capacity (VA) 5000 Output kva Capacity (kva) 5.0 2 / 6

Output Watt Capacity (Watts) 4500 Output kw Capacity (kw) 4.5 Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported Frequency Compatibility Frequency Compatibility Details Output Voltage Regulation (Line Mode) Output Voltage Regulation (Economy Line Mode) Output Voltage Regulation (Battery Mode) Output Receptacles Output Circuit Breakers Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 200V; 208V; 240V 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating) +/- 2% +/- 10% +/- 2% (2) L6-20R; (2) L6-30R 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered Pure Sine wave Pure Sine wave INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported Nominal Input Voltage Description UPS Input Connection Type 24A (200V), 24A (208V), 23.6A (220V), 23A (230V), 21.7A (240V) 200V AC; 208V AC; 240V AC Factory configured to 208V L6-30P UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3 Recommended Electrical Service Input Phase 30A Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility 3.5 minutes (4500 watts) 11 minutes (2250 watts) Supports extended runtime with optional external battery packs BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U (limit 1) DC System Voltage (VDC) 192 Battery Recharge Rate (Included Batteries) 6 hours from 10% to 90% (typical, full load discharge) 3 / 6

Internal UPS Replacement Battery Cartridge Battery Access Battery Replacement Description RBC5-192 (qty 1) Front panel battery access Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction Online, double-conversion power conditioning 2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less) 2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less) LEDS ALARMS & SWITCHES LED Indicators Front Panel LCD Display Audible Alarm Alarm Cancel Operation Switches 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual) Unique audible alarms for all major UPS, environmental and power conditions (see manual) Alarm cancel switch 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads SURGE / NOISE SUPPRESSION UPS AC Suppression Response Time EMI / RFI AC Noise Suppression Instantaneous Yes PHYSICAL Included Mounting Accessory Description Installation Form Factors Supported with Optional Accessories Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) 4 post rackmount installation accessories included 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND) Rackmount 6.85 x 17.5 x 20.7 17.4 x 44.5 x 52.6 Rack Height (U Spaces) 4 UPS Power Module Weight (lbs.) 113.6 UPS Power Module Weight (kg) 51.6 UPS Shipping Dimensions (hwd / in.) 12.7 x 23.6 x 29.1 UPS Shipping Dimensions (hwd / cm) 32.3 x 60 x 73.9 4 / 6

Shipping Weight (lbs.) 151.8 Shipping Weight (kg) 68.9 Cooling Method UPS Housing Material Fan Steel ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 5% to 90% (non-condensing) AC Mode BTU / Hr. (Full Load) 1767 AC Economy Mode BTU / Hr. (Full Load) AC Mode Efficiency Rating (100% Load) AC Economy Mode Efficiency Rating (100% Load) Operating Elevation (ft.) Audible Noise Operating Elevation (m) 638 90% 96% 0 to 6560 ft. / 0 to 2000 m 65 db at 1m front side 0-2000 m COMMUNICATIONS Communications Interface Network Monitoring Port Description PowerAlert Software Communications Cable WatchDog Compatibility USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Two contact closure monitoring options available - RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module) Included USB, DB9 serial and EPO cables included Yes LINE / BATTERY TRANSFER Transfer Time Transfer Time (Economy Mode) Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) No transfer time (0 ms.) in online, double-conversion mode 8 ms. typical power failure response in optional economy mode 156V (full load) / 100V (50% load or less, derates linearly) 280V (full load) / 300V (90% load or less) SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported 5 / 6

High Availability UPS Features Green Energy-Saving Features Automatic inverter bypass; Hot swappable batteries High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications UPS Certification Details Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances) IEC 61000-4-5 1995 B Surge Immunity WARRANTY Product Warranty Period (Worldwide) Connected Equipment Insurance (U.S., Canada & Puerto Rico) 2-year limited warranty $250,000 Ultimate Lifetime Insurance 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 6 / 6