Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems



Similar documents
System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

Epdm Flat Roofing Systems

Roofing Systems. New Applications / Re-Roofing / Maintenance

CONIROOF : Tailor-made Solutions for your Roof CONIROOF

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Site Inspection Report

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

The formation of roof waterproofing details calls for

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Low Energy Low Carbon Buildings

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Firestone RubberGard The EPDM reference

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Ubiflex. Non-lead flashing system

CHAPTER 7: Building Systems ROOFING SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

The existing roof angle change terminations and flashings when sound and intact can be reused.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

VM ZINC : standing seam Guidelines for specification and installation

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

RHEPANOL RHEPANOL FK ROOF COVERING SYSTEM

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane


Low Energy Low Carbon Buildings

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

BLACK JACK ALL WEATHER ROOF COATING

Your guide to home maintenance. Flat Roofs

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

The Harold J. Becker Company, Inc.

Rooflight INSTALLATION INSTRUCTIONS

Mechanically Fastened

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Polymeric membrane for roof waterproofing

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

GREEN ROOF SYSTEMS ADVANCED LIQUID ROOFING SYSTEMS GREEN ROOF INFORMATION AND DESIGN GUIDE GREEN ROOF SYSTEMS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Building Regulations for the Conservation of Fuel and Power

Asphalt Shingle Application Requirements

Proteus Waterproofing roof systems are tested to the most rigorous international standards, ensuring they will easily deal with our climate.

SECTION THERMOPLASTIC MEMBRANE ROOFING

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

SEAMS SEAMING USING SEAM TAPE

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS

Residential Roofing Guide

ITEM THERMOPLASTIC MEMBRANE ROOFING

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

SECTION STANDING SEAM METAL ROOFING

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

WATERPROOFING FOR CONCRETE STRUCTURES

DENSO WATERPROOFING SYSTEMS

Bituminous Sheet Flat Roofs: Their repair and maintenance

DELTA Premium Moisture Management Systems for Foundations.

Including. Rubershield-Pro. Breather Membrane

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

3 Installation. 9 Roof Edges... p Wall Terminations... p Membrane Repair... p Miscellaneous... p

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

12.1 Schlüter -KERDI-BOARD

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

SikaProof A Technology

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

3 BUILT-UP ROOFING THE RUBEROID BLUE BOOK

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

3 Installation. 3. Installation. EPDM Installation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

Syphonic Roof Drainage

Product Catalogue. Roofing and Waterproofing Membranes

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Consultants Handbook

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

INSTALLATION GUIDE. americanwick.com WICK (9425)

Monarflex Vapour Control Layers

Medicam house, Saint Germain Lambron - Architect: Trinh et Laudat - Contractor: Entreprise Duche. Roofing with VMZINC

Please read the entire document before purchasing and installing any of these products

SECTION PREFORMED METAL STANDING SEAM ROOFING

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Multi-layer Insulation Blanket for Roofs

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Technology at its best. Benefits

FLAGON PVC SINGLE-PLY ROOF WATERPROOFING SYSTEMS FLAGON SFc, SFb AND SV ROOF WATERPROOFING SYSTEMS

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, RBA Project No

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'

Transcription:

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems

Introduction A complete range of Memtec Roofing and Waterproofing Single Ply PVC Membranes to suit any type of roof, including all accessories. Memtec BBA certificate holder, number 12/4946 Long life expectancy in excess of 25 years. BBA confirmed. 15 and 20 year product guarantees. Maintenance free. UV resistant. Self extinguishing. Rot proof and high ageing resistance. Root penetration resistant. Thermofusible laps and seams electrically hot air welded without the requirement of dangerous naked flame or hot bitumen. Membranes are mesh reinforced providing maximum dimensional stability both crosswise and lengthwise. Vapour permeable, no blisters. Low temperature pliability minus 25 degrees centigrade without cracks. Can either be mechanically fixed, fully bonded or loose laid and ballasted. Lightweight, fast, clean installation. Excellent aesthetic appearance. Modern efficient performance and cost effective over many years. Special note for home owners of domestic property Single Ply PVC membrane roofing and waterproofing systems have now been employed in the main UK commercial and industrial roofing and waterproofing industry for some 40 years. Millions of square metres have been installed over that period and is part of the main reason for the dramatic decline in the use of old fashioned outdated bituminous felt and asphalt type roof covering systems. MEMTEC Modern efficient performance cost effective flat roofing systems Modern Memtec Single Ply PVC membrane roofing and waterproofing systems are now accessible and available to home owners of domestic property. If you are building a new house, house extension, conservatory or garage or are requiring new roof coverings to the existing flat roofed areas of your property then you should be considering a Memtec Single Ply PVC membrane roofing or waterproofing system which will give you a modern, efficient and cost effective performance over many years. (Please note an experienced installer should always be employed). 1

Rochester Riverside Development Kent Three apartment blocks, bin and cycle store. 2500m 2 of Single Ply PVC membrane roof coverings, colour light grey. Photo courtesy of Denne. Memtec Single Ply PVC Roofing and Waterproofing Systems are suitable for all flat roof situations and can be either mechanically fixed, fully bonded or loose laid and ballasted. Typical specifications are: Warm roof, cold roof, roof terrace and green roof (i.e roof garden). Can be applied to most roof deck substrates such as timber, metal, concrete and roof screeds. Can be applied to gutter substrates such as metal, timber and concrete. Totally suitable for existing roof refurbishment projects whereby an insulated or non insulated overlay system/specification can be applied over the existing roof coverings (in most cases) without the need to strip them. Can be applied to bituminous felt, asphalt (with stone chippings removed) and mineral finish felt. Can replicate the appearance of Traditional Metal Roofing Systems such as Lead Roof Coverings by adding timber mop roll battens and Memtec cover flashings (i.e see page 3 of this brochure) and also Zinc Metal Standing Seam Roof Coverings by adding Memtec decarib PVC Profile type roof decoration. Memtec Products are not susceptible to theft as they have no re-sale value unlike the actual Lead and Metal Products which do have a re-sale value. Generally by employing the Memtec Product against the Traditonal Lead and Metal Products a cost saving of approximately fifty percent can be achieved. Can be applied to sloping mansard and dormer roof areas and if decorated, as above mentioned, will replicate metal standing seam or lead roll type roof coverings which could be of particular interest for church, religious, traditional and listed type buildings. Please carefully note building control regulations should always be consulted when considering an existing roof refurbishment project in regards to the requirement to install insulation to comply with current legal obligations. 2

General Applications Typical upstand flashing to kerb in foreground and parapets beyond A traditional lead roll covered roof is replicated by employing the Memtec Single Ply PVC Membrane and lead roll batten flashings in colour lead (dark) grey Showing upstand flashing Actual traditional lead covered roof on adjoining property. MEMTEC Modern efficient performance cost effective flat roofing systems 3 Memtec Single Ply PVC membrane roof with lead roll flashing roof decoration Please note the above photographs are for illustrative purposes only

Typical Specifications MECHANICAL FIXED SYSTEMS Mechanical fixed system cold roof specification Mechanical fixed system warm roof specification NB. Items 6 and 7 can be thermally broken, fastener type. 1. Roof deck substrate 4. Memtec Single Ply Membrane types MF or MF-FB 6. Plate washer and fastener ADHESIVE BONDED SYSTEMS Adhesive bonded adhered system cold roof specification 1. Roof deck substrate 8. Memcol adhesive 4. Memtec Single Ply Membrane types BM, BM-FB or MF-FB EXISTING ROOF REFURBISHMENT OVERLAY SYSTEMS Existing roof refurbishment non insulated adhesive bonded overlay system 1. Roof deck substrate 2. Vapour control layer 3. Insulation board 4. Memtec Single Ply Membrane types MF or MF-FB 6. Plate washer and fastener membrane fastening type 7. Plate washer and fastener insulation fastening type Adhesive bonded membrane warm roof specification 1. Roof deck substrate 2. Vapour control layer 3. Insulation board NB. Vapour control layer type bituminous felt and insulation board can be bonded with cold applied adhesive. or Vapour control layer type polyethylene can be loose laid and the insulation board mechanically fixed. 4. Memtec Single Ply Membrane types BM, BM-FB or MF-FB 8. Memcol adhesive Existing roof refurbishment insulated adhesive bonded overlay system NB. Item 4 can also be mechanically fixed as an option therefore item 8 can be omitted. NB. Items 3 and 4 can be mechanically fixed as an option therefore item 8 can be omitted. 1. Existing roof deck substrate 5. Existing roof covering s bituminous felt or asphalt with stone chippings removed 8. Memcol adhesive 4. Memtec Single Ply Membrane type BM-FB or MF-FB Please carefully note building control regulations should always be consulted when considering an existing roof refurbishment project in regards to the requirement to install insulation to comply with current legal obligations. 1. Existing roof deck substrate 5. Existing roof covering s bituminous felt or asphalt with stone chippings removed 8. Memcol adhesive 3. Insulation board 4. Memtec Single Ply Membrane types MF-FB, BM or BM-FB 4

Mechanically fixed system installation guide 1 Setting out of the pressure plate washers along the main field sheet edge and layout of the main field sheet overlap 2 Mechanical fixing of the membrane main field sheet 3 Hot air welding the overlap seam 4 Mechanical fixing of the drip edge trim MEMTEC Modern efficient performance cost effective flat roofing systems 5 Cover flashing main field sheet to drip edge trim 5

6 Cover flashing main field sheet to PVC faced drip edge trim 7 Hot air welding of the cover flashing 8 Adhesive application to upstand substrate 9 Adhesive application to upstand flashing 10 Hot air welding of the upstand flashing to the Memtec metal PVC faced 2.8 chase trim 11 Installed upstand detail with preformed corners All photos are for illustration purposes only and we reserve the right to amend and/or change details at any time without prior notice. 6

Adhesive bonded system installation guide 12 Adhesive application to deck substrate and membrane main field sheet 13 Membrane main field sheet bonded to deck substrate 14 Hot air welding of the overlap seam 15 Mechanical fixing of roof perimeter peel stop restraint bar 16 Adhesive application to upstand substrate and upstand flashing 17 Installing the membrane upstand flashing MEMTEC Modern efficient performance cost effective flat roofing systems 7 18 Hot air welding of the upstand flashing to the Memtec metal PVC faced 2.3 wall counter flashing trim 19 Hot air welding of the upstand flashing to the horizontal area main field sheet

20 Silicone sealant application to 2.3 wall counter flashing trim 21 Drip edge trim and membrane cover flashing 22 Hot air welding of roof decoration type decarib PVC profile (optional) 23 Installing a pipe flashing 24 Pipe flashing detail 25 Silicone sealant application to pipe flashing collar (note also requires a stainless steel jubilee clip or nylon cable tie) 26 Testing all hot air welded seams with a seam testing probe 27 General overview and appearance that can be achieved 8 All photos are for illustration purposes only and we reserve the right to amend and/or change details at any time without prior notice.

Products Memtec membrane type BM-FB and MF-FB fleece backed for mechanical fixed or bonded systems. Colours light or lead (dark) grey Memtec membrane types MF or BM non fleece backed for mechanical fixed or bonded systems. Colours light or lead (dark) grey Geotextile for isolation-separation to bituminous and polystyrene surfaces Memtec PVC decarib profile roof decoration to imitate a metal standing seam roof appearance. Colours light or lead (dark) grey Memtec metal PVC faced chase wall trim colours light or lead (dark) grey Memtec metal PVC faced drip edge trim colours light or lead (dark) grey. All size requirements catered for including bespoke sizes MEMTEC Modern efficient performance cost effective flat roofing systems 9 Memtec metal PVC faced 2.3 wall counter flashing trim colours light or lead (dark) grey Galvanised steel peel stop perimeter restraint bar for adhesive bonded systems

PVC internal corner colours light or lead (dark) grey PVC external corner colours light or lead (dark) grey Aluminium self adhesive tape. Application to insulation board joints with adhesive bonded systems Thermally broken washer and fixing for mechanically fixed membrane system to a warm roof specification i.e insulated Thermally broken washer and fixing for securing insulation board to roof deck. ie mechanical fixed method Pressure plate washer and fixing for lap fix mechanical fixed membrane system to a cold roof specification ie uninsulated Drive rivet fixings for Memtec metal trims to concrete or brickwork Vertical drain rainwater outlet, various diameters available Horizontal drain rainwater chute scupper Rainwater overflow PVC leafguard for vertical drain type rainwater outlets Memtec reserves the right to amend, change or substitute its products for equal similar approved products without prior notice. Memcol adhesive types CA and WB for bonded systems membrane types BM, BM-FB and MF-FB 10

Memtec Services Product Sales and Supplies including all accessories to complete and complement the system. Courier delivery service throughout the UK available (charges apply). Product Technical Advice and Support available. Product Installation Advice and Support available. Product Installation Guidance Classes available (charges apply). Product Literature and Samples available upon request. Our Senior Staff have over forty years experience of working within the main UK Single Ply PVC Membrane Roofing and Waterproofing Industry. We offer a Professional, Experienced and Friendly Service. For all further information contact Memtec Limited or visit our website. Memtec Limited Unit A, Brightside Westfield Sole Road Boxley Maidstone Kent ME14 3EH Tel: 01634 869806 Fax: 01634 682436 Email: info@memtec.co.uk Website: www.memtec.co.uk MEMTEC Modern efficient performance cost effective flat roofing systems