Global Data Center Solutions



Similar documents
CyrusOne Global Data Center Solutions

CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY.

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

Digital Chicago. 600 south FeDeraL - chicago grand ave - FranKLin ParK 350 east cermak - chicago

RAGINGWIRE. THE WORLD S MOST TECHNOLOGICALLY ADVANCED DATA CENTERS!

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

OPERATOR - FACILITY ADDRESS - DATE

AT&T Internet Data Center Site Specification Washington-DC Area (Ashburn, VA)

Data Centre Infrastructure

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Data Center CH1. Elk Grove Village, IL

colocation. perfected. Overview

colocation. perfected.

How To Visit An Internet Data Center

X-tier Data Facility. Prepared by X-tier SAE Corporation

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

CASE STUDY. Nirvanix, Inc. Finds a Secure and Reliable Data Center and a Strategic Partner for Cloud Services at CyrusOne

Data Centre Barrie, Ontario

19 Site Location, Design and Attributes. Site Location, Design and Attributes

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Datacentre South London Data sheet

How To Build A Data Center For Ragingwire

Nirvanix, Inc. Finds a Secure and Reliable Data Center and a Strategic Partner for Cloud Services at CyrusOne

VOLICO. Colocation Hosting. Enterprise Hosting Solutions

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

colocation. perfected.

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

AT&T Internet Data Center Site Specification Dallas Area (Allen, Tx)

Seattle London

Experience Matters...

Santa Clara, CA 95054

NY2 21 CRITICAL MEGAWATTS 280,000 SQUARE FEET

Our Hosting Infrastructure. An introduction to our Platform, Data Centres and Data Security.

Assessment of Existing Data Centers for Critical Facilities Round Table Group

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

N O W A V A I L A B L E

LEVEL 3 DATA CENTER SERVICES IN SAN FRANCISCO HOUSE POWER-INTENSIVE APPLICATIONS AND SUPPORT BUSINESS CONTINUITY

Global Data Center & Colocation Facilities

Datacentre Maidenhead P1 Data sheet

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

Chicago 1 (CHI-1) Data Center

Tier IV Enterprise - Class Data Center

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

The Sky for the Cloud : CyrusOne Data Centers. Fred Holloway Vice President, Partner Ecosystem CyrusOne, LLC

Datacentre Reading East 2 Data sheet

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

Pacnet Hong Kong CloudSpace2 Technical Specifications. Upholding the Principles of Efficiency and Sustainability in Data Center Design

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

Scalable. Affordable. Flexible. Fast.

1301 Fannin. Houston Data Center & Office Facility

House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data

CASE STUDY. CyrusOne Helps City of Houston to Go Green and Reduce Energy Consumption through Data Center Consolidation

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

Secure I Reliable I Flexible COPT DC Hornbaker Road, Manassas, Virginia

LDeX Group. Colocation Solutions for High Expectations

Subject: County of Los Angeles Data Center Space Requirement

Wholesale Data Center Suites Available Now

COMMODITIZING THE DATA CENTER MARKET

Colocation Buyer s Guide and Checklist. A Playbook for Technology Managers

Building a data center. C R Srinivasan Tata Communications

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Datacentre South Gyle 1 Data sheet

CHICAGO S PREMIERE DATA CENTER

ISOMEDIA COLOCATION

GREENSBORO TYSONS CORNER, VA

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Data Center:Build-to-Suit

EXECUTIVE REPORT. Seven Critical Success Factors for Choosing A Reliable Data Center Provider

NeuStar Ultra Services Physical Security Overview

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

Data Center Checklist

Data Centers in Hong Kong Powering business success

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Data Centre Southeast AMS 5, Netherlands Highly connected, premium data centre.

Data Center Infrastructure & Managed Services Outline

Transcription:

Global Data Center Solutions Corporate Contact: 1649 W Frankford Road, Carrollton, TX 75007 (866) 297-8766

Leader in Global Data Center Colocation Built for tomorrow. Ready today. CyrusOne has quickly emerged as a global leader in enterprise, data center colocation services. The company s ability to bring on new data center inventory in record time, around the globe, allows it to accommodate the data center requirements of the Fortune 1000. Unsurpassed in Customer Satisfaction Receive excellent customer service from day one. CyrusOne has one of the industry s highest repeat customer scores and client satisfaction ratings. With 25 data centers worldwide, CyrusOne continues to add to its portfolio high performance data centers that are efficiently designed to power, cool and secure large, high density server environments. CyrusOne s state-of-the-art facilities, flexibility, scale, and expert solutions delivered through personalized service, are the best choice for global businesses seeking mission-critical data center solutions. OF CUSTOMERS WOULD RECOMMEND CYRUSONE

Our locations Top global 3000 companies have colocated in the most advanced data centers on the planet for more than a decade. Strategically located to take advantage of ample access to power and high-density connectivity, CyrusOne data centers avoid the risk of natural disasters. Learn how this global presence can help meet your data center needs. CyrusOne Data Centers +2 +6 Thailand Cambodia Vietnam +2 +5 +2 +5 +2 Malaysia Singapore Malaysia United Kingdom United States Arizona Phoenix/Chandler Data Center Illinois Chicago Metro Data Center Kentucky Florence Data Center Ohio - Mason Mason Data Center Ohio - Cincinnati Blue Ash Data Center Cincinnati Data Center Gold Coast Data Center Hamilton Data Center Lebanon Data Center North Cincinnati Indiana Blackthorn Monroe Texas - Houston Houston Galleria Data Center Houston West Data Center Texas - Austin Met Center I Data Center Met Center II Data Center Texas - Dallas Carrollton Data Center Carrollton Mega Center Dallas Downtown Data Center North Dallas/Lewisville Data Center Texas - San Antonio San Antonio Data Center International UK London Data Center Singapore Jurong Data Center

Houston Galleria 100,000 sq. ft. 100,000 sq. ft. data center / 64,000 sq. ft. of raised white floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) 13.5MW of critical capacity Dual input PDU s with static transfer switches Backed by generator power 3,300 belly tank each plus an added 6,000 gallon external tank for every generator Combo of cooling technologies including DX and closed loop chilled water using multiple 500 ton Trane chillers 36 & 24-inch raised floor design Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Perimeter fence Central location to dozens of hotels, restaurants, and other amenities

Houston West Bldg #1 162,000 sq. ft. 162,000 sq. ft. data center / 112,000 sq. ft. of raised white floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Efficient, divisible floor plates Extra layer of physical security including hurricane shutters, extra diesel on-site, outside of flood zone Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) 28MW of critical capacity Dual input PDUs with static transfer switches Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 3,300 belly tank each plus an added 6,000 gallon external tank for every two generators Utilizing Stultz 70-ton CRAH units with electronically communicated (EC) variable-speed fans Highly efficient multiple 500 ton chillers with fast restart and adaptive controlled microprocessors Ability to scale as density increases Redundant water feeds with on-site storage tank and city well Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Central location to dozens of hotels, restaurants and other amenities

Houston West Bldg #2 160,000 sq. ft. Will support up to 160,000 sq. ft. data center / 80,000 sq. ft. of raised white floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 200 wpsf with the ability to support over 1,000 wpsf Efficient, divisible floor plates Extra layer of physical security including hurricane shutters, extra diesel on-site, outside of flood zone Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) Can accommodate up to 24MW of critical capacity Dual input PDUs with static transfer switches 2.25 MW Dedicated Diesel generators 5,000 gallon belly tanks at each generator Utilizing Stultz 100-ton CRAH units with electronically commutated (EC) variable-speed fans Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors Ability to scale as density increases Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Central location to dozens of hotels, restaurants and other amenities

Houston West Bldg #3 640,000 sq. ft. (Completion Q4 of 2014) Will support up to 640,000 sq. ft. campus / 450,000 sq. ft. raised floor Planned - SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 200 wpsf with the ability to support over 1,000 wpsf Efficient, divisible floor plates Extra layer of physical security including hurricane shutters, impact resistant glazing, extra diesel on-site, outside of flood zone Carrier-neutral and part of CyrusOne IX (Internet Exchange) Multiple shippping docks Can accomodate up to 86MW of critical capacity Dual input PDUs with static transfer switches 2.25 MW Dedicated Diesel generators 5,000 gallon belly tanks at each generator Utilizing Stultz 200-ton CRAH units with electronically commutated (EC) variable-speed fans Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors Extra layer of physical security including impact resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Central location to dozens of hotels, restaurants and other amenities

Northern Virginia 420,000 sq. ft. 420,000 sq. ft. campus at full build / 115,000 sq. ft. Phase 1 Planned - SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 200 watts/sf with the ability to support over 1,000 watts/sf. Efficient, divisible floor plates Carrier-neutral facility 100% Uptime service level agreement on power Up to 48MW of critical capacity Multiple levels of redundancy available within the same footprint (i.e. N, Distributed Redundant, 2N, or a combination) Dual-Input PDUs with Static Transfer Switches (STS s) 2.25MW dedicated diesel generators 6,000-gallon belly tanks for each generator (supports critical load for 48-hours) with diverse refueling agreements Utilizing Stulz 200-ton CRAH units with electronically communicated (EC) variable-speed fans Highly-efficient 500-ton Trane chillers with rapid restart and adaptive controlled microprocessors Ability to scale as density increases in an N+1 central plant design and an N+20% air-side design Reinforced physical structure including perimeter fence with sliding entry and exit gates Secure entry with man traps and security monitoring area comprised of steel-lined walls for security, and bullet resistant glass On-site security guards 24-hours per day, 365-days per year Man traps, biometric and key card (color-coded) security for rigid access control CyrusOne Loudoun County Tech Center Site Plan - February 12, 2014 2014 Gensler. All right Very Early Smoke Detection Apparatus (VESDA) system, sampling air in parts per million coupled with a zoned dual-action, interlocking dry-pipe sprinkler system Conveniently located near dozens of hotels, restaurants and other amenities Ten minutes from Dulles International Airport and 30 minutes from Ronald Reagan Washington Airport

Lewisville 200,000 sq. ft. 200,000 sq. ft. data center / 110,000 sq. ft. raised floor space SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) 26.5MW of critical capacity Fault tolerant power design Onsite dedicated substation providing redundant underground feeds connected to redundant 25MVA transformers Two independent power grids Onsite substation fed by 3 separate substations (Argyle, Carrollton, and Lewisville) Multiple MGE 8000 625kVA UPS systems; each power leg has a dedicated UPS with battery backup Dual input PDUs with static transfer switches Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 3,300 belly tank each plus an added 6,000 gallon external tank for every two generators 36/48-inch raised floor design Utilizing Stultz 70-ton CRAC units with electronically communicated (EC) variable-speed fans Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors Chilled water loops Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Perimeter fence Common area and kitchen; Custom office spaces 9 Minutes from DFW International Airport

Carrollton 670,000 sq. ft. Largest data center in the state - will support up to 670,000 sq. ft. data center / planned for 400,000 sq. ft. raised white floor, and 60,000 sq. ft. office space One of the most efficient in the country Massive Modular Scale; holds six 747s, 4 football fields, 15 Space Shuttles and 2 Washington Monuments SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) Wholesale and retail colocation options Flood zone rating is Zone X (low risk) Seismic zone rating is Zone 0 (lowest risk) Commercial zone rating is light industrial Can accommodate up to 60MW of critical capacity 150 200+ watts per sq. ft. Diverse power delivered by two independent circuits 750kVA Mitsubishi UPS systems; each power leg has a dedicated UPS with battery back-up Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 5,000 gallon belly tank per generator Modular/Scalable cooling design Hybrid cooling systems unique indirect evaporative with redundant DX 80% free cooling Indirect evaporative cooling units provide best in class efficiency Utilizes free air cooling NO CRAC/CRAH units on datacenter floor NO water on datacenter floor. 35 ft. ceiling height from datacenter floor Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Perimeter fence Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled 60,000+ office space, Common areas, Recreation center, Premium customer offices and kitchen Helicopter pad; 9 Minutes from DFW International Airport Gordon grid dropdown ceiling; No height restrictions on cabinets

Austin Met Center I 45,000 sq. ft. 45,000 sq. ft. data center/ 17,000 sq. ft. raised white floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, concurrently maintainable design High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) 2.2MW of critical capacity Diverse power delivered by two independent circuits Dual input PDUs with static transfer switches Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 3,300 belly tank each plus an added 6,000 gallon external tank for every two generators Utilizing Stultz CRAH units with electronically communicated (EC) variable-speed fans Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass of each facility Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Perimeter fence 7 minutes from Austin International Airport

Austin Met Center II 70,000 sq. ft. Will support up to 70,000 sq. ft. data center / 41,000 sq. ft. raised floor, with 3 adjacent land pads available for growth SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) Wholesale and retail colocation options Worksite recovery: customizable to fit client needs Up to 9MW of critical capacity Two 400 MW capacity substations with dual underground, concrete encased feeds from electrical substations Multiple MGE 8000 625kVA UPS systems; each power leg has a dedicated UPS with battery backup Dual input PDUs with static transfer switches Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 3,300 belly tank and 12,000 gallon external tank Batteries are isolated in a different room from the UPS 48-inch raised floor design Utilizing Stultz 70-ton CRAH units with electronically commutated (EC) variable-speed fans Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors (ability to scale as density increases) Redundant closed loop chilled water cooling design Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Triple authentication man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Perimeter fence 16 hotels and 15+ restaurants within three-mile radius of the data center Seven minutes from Austin-Bergstrom International Airport Secure parking for customers and visitors

San Antonio #1 83,000 sq. ft. 83,000 sq. ft. data center / 44,000 sq. ft. raised floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Wholesale and retail colocation options Only enterprise rated datacenter in the city Low cost of power in this market Low risk from disasters including hurricanes, tornados and earthquakes Land and Building owned, not leased Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) 12MW of critical capacity 150 200+ watts per SF Two 200 MW substations provide power to the site Regulated utility provider CPS Energy Dual input PDUs with static transfer switches Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 5,000 gallon belly tank per generator Closed loop chilled water cooling design Utilizing Stultz 100-ton CRAH units with electronically communicated (EC) variable-speed fans Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control 30,000 sq. ft. office space Minutes from International Airport Gordon grid dropdown ceiling

San Antonio #2 372,000 sq. ft. 372,000 sq. ft. campus upon two phase completion Up to 196,000 sq. ft. of raised white floor across multiple phases Planned - SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable; supports 250 wpsf with the ability to support over 1,000 wpsf Carrier-neutral, as well as dark-fiber connectivity option CyrusOne s second enterprise-rated datacenter in the city Can accommodate up to 36MW of critical capacity Configurable to multiple levels of redundancy (e.g. N, 2N) per customer needs (2) 53 MVA transformers provide power to the site Regulated utility provider CPS Energy 400 kva dual-input PDUs with static transfer switches Scalable 2.25 MW MTU dedicated generators with space for further densification 6,000 gallon belly tank for each generator Closed loop chilled water cooling design Stultz 200-ton CRAH units with electronically commutated (EC) variable-speed fans Trane 500-ton highly efficient chillers with fast restart and adaptive controlled microprocessors Security guards on-site 24 hours a day, 365 days a year Man traps, biometric, and key card (color coded) security for rigid access control Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled Over 20,000 sq. ft. of Class A office space across two phases Fitness center, numerous break rooms, and collaboration areas Minutes away from several hotels and restaurants

Phoenix #1 1,000,000 sq. ft. Planned to be the largest data center campus in the state up to 1,000,000 sq ft campus / 40 acre land purchase One of the most efficient in the country SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4} High Performance Computing (HPC) capable, supports 250 wpsf with the ability to support over 1,000 wpsf Highly efficient power and cooling Historically free of seismic activity, tornados, and hurricanes Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange) Can accommodate up to 90MW of critical capacity (Campus) 110 MW onsite substation Dual underground power feeds to onsite substation Dual Input PDU s with Static Transfer Switches Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity 5,000 gallon belly tank Hybrid cooling system combining evaporative and chilled water technology Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors Inverted roof design with no columns on the raised floor for efficient hot air removal Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Cabinet and cage security options include individual locks biometric scanners Perimeter fence with a dual interlocked, pre action dry-pipe system State-of-the-art offices Fitness center, staging room, hoteling space

Phoenix #2 102,000 sq. ft. 102,000 sq. ft. data center Master planned for 60,000 sq. ft. of raised white floor across two data halls Planned certifications: SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4 High Performance Computing (HPC) capable; supports 250 wpsf with the ability to support over 1,000 wpsf Carrier-neutral, as well as dark-fiber connectivity option CyrusOne Chandler South Ellis Rendering 05/08/2014 Building 4 05/08/2014 Ability to hold up to 12 MW of critical capacity Configurable to multiple levels of redundancy (e.g. N, 2N) per customer needs (2) 53 MVA transformers provide power to the site Regulated utility provider SRP Energy 375 kva dual-input PDUs with static transfer switches Scalable 2.25 MW MTU dedicated generators with space for further densification 6,800 gallon belly tank for each generator Closed loop chilled water cooling design Stultz 200-ton CRAH units with electronically commutated (EC) variable-speed fans Trane 500-ton highly efficient chillers with fast restart and adaptive controlled microprocessors Security guards on-site 24 hours a day, 365 days a year Man traps, biometric, and key card (color coded) security for rigid access control Over 8,000 sq. ft. of Class A one-story office space Speculative office space, conference rooms, break rooms, and collaboration areas Minutes away from several hotels and restaurants

Chicago 30,000 sq. ft. 30,000 sq. ft. data center / 14,000 sq. ft. raised floor white space Expansion space available for custom data halls or office space SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA High Performance Computing (HPC) capable, supports 150 wpsf Carrier-neutral, as well as dark-fiber connectivity option Separate cable tray for fiber and copper 9MW of critical capacity Multiple levels of redundancy available within same footprint Both a 1.5MW and a 2MW transformer 150kVA PDUs with single feed Scalable 2.4 MW Cummins dedicated generators 8,000 gallon site capacity 24 and 36-inch raised floor design Glycol cooling loop Utilizes CRAC unit with 420 ton cooling capacity Biometric security scans of facility Biometric and key card (color coded) security for rigid access control 20 minute drive to Chicago O Hare Airport 10 National Chain Hotels within one mile 20 miles west of the heart of downtown Chicago

Cincinnati Downtown 400,000 sq. ft. 400,000 sq. ft. data center/ 212,000 sq. ft. raised floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA High Performance Computing (HPC) capable Carrier-neutral, as well as dark-fiber connectivity option Built to Fujita F2 wind rating Cincinnati s primary switching facility on FEMA priority list 13MW of critical capacity 7 Dedicated Substations in the building which are not shared with other buildings Facility has 6 independent power feeds, extremely reliable utility infrastructure 25kVA single input PDUs with automatic transfer switches Scalable 2 MW Cummins dedicated generators 40,000 gallon fuel capacity for site (2-20K gallon tanks) 24 or 36-inch raised floor design Highly efficient multiple 1200 ton York Centrifugal chillers Multiple 115-ton Huntair ACU with electronically commutated (EC) variable-speed fans; other levels/halls utilize 30 and 40 ton CRAC units Closed loop chilled water cooling with redundant feeds for makeup water 7 levels of security for access Reinforced physical structure including concrete bollards of each facility Man traps, revolving entrance doors; key card security for rigid access control Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million FM200 or FE-25 clean gas suppression in a full flood deployment 15 Minute drive to Greater Cincinnati/Northern Kentucky International Airport Major Metropolitan Downtown; 10 National Chain Hotels within four blocks; 40 peering arrangements, harden Bell constructed building

North Cincinnati 151,000 sq. ft. Can support up to 151,000 sq ft / 65,000 sq ft raised white floor Used for production colocation, back-up and recovery and business continuity SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA High Performance Computing (HPC) capable DWDM (high availability/high reliability) networking connectivity options for customers who are in other CyrusOne mid-west data centers (North Cincinnati, Downtown Cincinnati, Florence and Hamilton) Carrier-neutral facility with diverse fiber feeds 100% SLA on power and environmentals Used for production colocation, back-up and recovery and business continuity Up to 13.5MW of critical capacity Industry leading PUE Diverse power delivered by two independent circuits 8-2 MW generators 300 kva single input PDU fed from dual input static transfer switches 40,000 gallon fuel tank capacity 48-inch raised floor design Chilled Water System Configuration Unique cooling technology: Utilizes 115-ton Huntair ACU Fan-wall technology 150+ watts per square foot of density Free cooling under 45 degree Fahrenheit utilizing four 900 ton plate and frame heat exchangers 6 levels of security for access Reinforced physical structure Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled 40 miles to both Greater Cincinnati/Northern Kentucky International Airport and Dayton International Airport 10 Hotels within 10 miles 30 minutes from downtown Cincinnati

London 5,000 sq. ft. 5,000 sq. ft. raised floor within 200,000 sq. ft. data center 12 acres campus Carrier-neutral, as well as dark-fiber connectivity option Up to 150 Watts per foot Diverse power delivered to the site by 2 independent 132 KVA feeds 1500KVA Diesel generators 94 MW of power 29.5-inch (750mm) raised floor design Airedale Chillers Highly efficient multiple 500 ton Trane chillers with fast restart and adaptive controlled microprocessors (ability to scale as density increases) Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass X-Ray Scanners of each facility Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Located in Goldsworth Park Trading Estate

Singapore 5,000 sq. ft. 5,000 sq. ft. raised floor within 210,000 sq. ft. data center High Performance Computing (HPC) capable, supports 150 wpsf Carrier-neutral facility Scalable densities Diverse power delivered by two independent power grids 36 Generators 31.5-inch (800 mm) raised floor design Closed loop chilled water cooling design 31.65MW of total capacity with dual chilled water loops 5 Chilled Water Risers Reinforced physical structure including concrete bollards, steel-lined walls for security, and bullet resistant glass of each facility Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid access control Underground entry points

Other Data Center Locations BLACKTHORN 8,500 sq. ft. data center / 3,400 sq. ft. raised floor white space SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA Multiple levels of redundancy available within same footprint 24-inch raised floor design MONROE 15,000 sq. ft. data center / 6,100 sq. ft. colocation space SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA Multiple levels of redundancy available within same footprint Slab and 12-inch raised floor design FLORENCE 140,000 sq. ft. data center / 55,000 sq. ft. white space available SSSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA Multiple levels of redundancy available within same footprint BLUE ASH 15,000 sq. ft. data center/ 6,000 sq. ft. raised white floor Up to 900 kw available 14-inch raised floor design 20, and 22 ton Liebert Downflow Chilled Water CRAC units GOLD COAST 25,000 sq. ft. data center/3,000 sq. ft. raised white floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA 1.2 MW Caterpillar dedicated generators 24-inch raised floor design DX cooled MASON 75,000 sq. ft. data center/35,000 sq ft raised white floor SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA Multiple levels of redundancy available within same footprint 24-inch raised floor design HAMILTON 83,000 sq. ft. data center SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA 550 gal tank per generator with 30,000 gallon site capacity

Other Data Denter Locations NORTH HOUSTON GREENS POINT 15,000 sq. ft. data center CARROLLTON TECHNOLOGY CENTER 10,000 sq. ft. data center DOWNTOWN DALLAS 3,000 sq. ft. data center DALLAS MIDWAY 10,000 sq. ft. data center