Communicating Thermostat System Installation Manual



Similar documents
Installation Instructions

Install Guide 3M-50. Caution. Caution

Bluetooth HC-06 with serial port module Easy guide

HEAT PUMP PROGRAMMABLE THERMOSTAT

How to read this guide

PM1122 INT DIGITAL INTERFACE REMOTE

LOW VOLTAGE CONTROL CIRCUIT WIRING

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

for Windows Media Center User's Guide

User Manual THR840DUK Digital Thermostat

Chapter. PLC Communications

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

EDI Distributor Control Interface Wiring and Setup Instructions

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Table of Contents. 1 - Specifications Installation Wiring User controls...7

8 Channel Status Input Panel model SIP-8

HEAT HEAT COOL HEAT PUMP COOL

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

T7560A,B,C Digital Wall Module

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Table of Contents. Creating a VC1000 Network... 3

Chapter. Getting Started. In This Chapter...

T-100-R Installation Guide

Install Guide CT101. Caution. Caution

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Digital Adapter Easy Setup Guide

PPM Users Manual Signature Software

INSTALLER S & OWNER S MANUAL

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

RS232 Programming and Troubleshooting Guide for Turbo Controls

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 (

RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)

-Helping to make your life betterwww.person-to-person.net

Accessing Diagnostics using a Dialup Modem

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

System Requirements. Hiro H50113

Installation Guide Solar Connect-11

Using HyperTerminal with Agilent General Purpose Instruments

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

INSTALLATION & SERVICE MANUAL. Display Panel

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

PowerLogic Sub Meter Display (SMD and SMDOPN)

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.

IP SERIAL DEVICE SERVER

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Troubleshooting and Diagnostics

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

TC02 Curtain heater controller

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Getting Started with IntelleView POS Administrator Software

Application/Connection Examples

Date Rev. Details Author

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

1 Getting Started. Before you can connect to a network

LiteKeeper 4 & 8 Programming Guide and User Manual

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Electronic Control Devices The European Product Catalogue 2007

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

LTM-1338B. Plus Communications Manual

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Table of Contents. GETTING STARTED...1 Technical Support...1 Scanner Configuration...2 Login and Select a Mode...4

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Simon XT/XTi CDMA Module V4 Installation Instructions

Global Monitoring + Support

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Setting Up the ZigBee Ethernet Gateway

L5354 ControlNet Communications Interface

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

QUICK INSTALLATION GUIDE

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

LIEBERT VNSA Installation Sheet

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

SAFEPATH 4 Telephone Zone Controller

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

PCI/PXI ETHERNET ADAPTERS

F453. TiF453. User guide 10/11-01 PC

How To Control A Thermostat

Keep it Simple Timing

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

Business/Home GSM Alarm System. Installation and User Manual

Transcription:

THE EST IN INDOO I OMFOT UTOMTED HV ommunicating Thermostat System Installation Manual PT OF THE PILIE INDOO I OMFOT SYSTEM

OMMUNITING THEMOSTT SYSTEM INSTLLTION MNUL This manual will guide the installer through the installation, wiring and checkout of an prilaire Model 8870 ommunicating Thermostat System. Instructions for the prilaire 8840 Series communicating thermostat system are found in a separate document (DP 10004345). portion of the command set is found in ppendix 2 in this manual. For a complete command set with programming suggestions, see the programming manual (DP 10005756). ontact esearch Products orporation for these documents at 888-782-8638. THEE E 14 STEPS INVOLVED IN THE INSTLLTION OF OMPLETE SYSTEM. Step 1 GET LL THE OMPONENTS YOU WILL NEED 1 Step 2 DISONNET POWE TO LL HV EQUIPMENT ND/O ZONE ONTOL PNELS 2 Step 3 UN THE EQUIED S 3 Step 4 LOTE ND MOUNT THE UTOMTION SYSTEM OMPONENTS 4 Step 5 ONNET THE ONTOL S TO THE HV/ZONE SYSTEM ND THEMOSTTS 6 Step 6 ONNET THE OMMUNITION ND POWE S TO THE DISTIUTION PNEL ND THEMOSTT 8 Step 7 ONNET MULTIPLE DISTIUTION PNELS 9 Step 8 ONNET POTOOL DPTE TO THE DISTIUTION PNEL ND HOST OMPUTE O UTOMTION SYSTEM 10 Step 9 POVIDE POWE TO THE DISTIUTION PNEL 11 Step 10 TUN ON POWE TO LL HV EQUIPMENT ND TO THE THEMOSTTS 11 Step 11 HEK-OUT HV SYSTEM OPETION 11 Step 12 DDESS THE THEMOSTTS ND SET HIGHEST DDESS 12 Step 13 SETUP OMPUTE FO OMMUNITION SYSTEM HEKOUT 13 Step 14 HEK-OUT OMMUNITIONS TO THE THEMOSTT NETWOK 16 ppendix 1 SPEIL ONSIDETIONS FO INSTLLING THE MODEL 8870 WITH THE 8840 SEIES OMMUNITING THEMOSTT 17 ppendix 2 PILIE OMMND SET 19 EXT NETWOK INTEONNETION WOKSHEET 21 WNING 1. 120 volts may cause serious injury from electrical shock. Disconnect electrical power to the HV system before starting installation. This system is a low-voltage system. 2. Improper installation may cause serious injury from electrical shock. This system must be installed by a qualified contractor in accordance with NE Standards and applicable local and state codes. esearch Products orp.

Step1 GET LL THE OMPONENTS YOU WILL NEED OMPONENTS YOU WILL NEED (see ILLUSTTION 1) One prilaire Model 8870 ommunicating Thermostat for each zone or single zone HV system One prilaire Model 8818 Distribution Panel per eight (8) thermostats in the system One prilaire Model 8811 Protocol dapter per 32 thermostats or one per Model 8823 system controller 4 to 8 conductor thermostat cable depending on equipment stages (18 20 gauge) ategory 5 communication wire (4-pair twisted cable) One 24V transformer, ungrounded (part number 8027) per 8818 Distribution Panel S-232 or S-485 based automation system such as the prilaire Model 8823 System ontroller OPTIONL: prilaire Model 8061 Temperature Support Module or Model 8062 Temperature/Humidity Support Module ILLUSTTION 1 System omponents Model 8870 Thermostat S-422 ommunicating Thermostat controls single or multi-stage heat/cool or heat pump HV systems. TOOLS YOU WILL NEED Small flat head screwdriver for terminal screws (1/8 wide tip) Medium size flat/phillips head screwdriver for component mounting screws Volt/ohm meter omputer with available com port (S-232) and terminal emulator such as HyperTerminal (for system checkout) Wire strippers Small level (use to mount components level, required for appearance only) + - + - + - + - + - + - + - + - 24V + - + - EF FUSE SPE FUSE Model 8818 Distribution Panel Switches in the Distribution Panel allow power or communications to be turned off at each individual thermostat to make installation and troubleshooting easy. MIN - + - + - + - + - + - + - + - + POWE X TX X TX X TX DT S-485 ENLE S-485 DT S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 Model 8811 Protocol dapter Use to convert S-485 communication signal from prilaire ommunication System to S-232 communication signal readable by host computer. Supports up to 32 thermostats. Model 8061 and 8062 Support Modules Up to four can be connected to a single thermostat to sense temperature or relative humidity at a location remote from the thermostat. 1

MODEL 8870 THEMOSTT The Model 8870 Thermostat is field configurable to operate single and multi-stage separate heating and cooling equipment (such as furnace and air conditioner or roof top units), or single and multi-stage heat pump systems. menu driven set up, using the message center display of the thermostat, can be used to configure many other features. Network communication is non-isolated, full duplex S-485 (S-422). The terminals are the transmit pair while the terminals are the receive pair. This nomenclature uses the computer or host as the reference, so transmit refers to the lines on which the host transmits data to the thermostat while receive refers to the lines on which the host receives data from the thermostat. The baud rate is selectable between 9600 and 19200. Up to 64 uniquely addressed thermostats may reside on the same thermostat network. MODEL 8818 DISTIUTION PNEL The Distribution Panel is a switch controlled communication bus that can be wired to eight (8) prilaire Model 8870 thermostats. This allows thermostat communication (transmit, receive or both) to be turned on and off at one convenient location which simplifies installation and trouble shooting. Each thermostat station on the distribution panel has an on/off switch for power. This allows isolation of any one thermostat to simplify troubleshooting. Order one Distribution Panel per eight thermostats. Step 2 MODEL 8061 ND MODEL 8062 SUPPOT MODULES Support modules are used to either monitor or control temperature or humidity at a location other than the thermostat. They communicate with the thermostat using a S-485 protocol. Up to four support modules may be wired to a thermostat, with each module able to support two sensors. The Model 8061 has one onboard temperature sensor and room for one offboard temperature sensor (sensor #1 & sensor #2) while the Model 8062 has one onboard temperature sensor (sensor #1) and one onboard humidity sensor (sensor #2). ll sensors can be configured as either a control sensor (replaces thermostat temperature sensor as control variable) or a monitor sensor (read only). n offboard sensor such as a Model 8051 Flush Mount Sensor can replace sensor #1 on the Model 8062 or both on the Model 8061. Each support module is addressed and each sensor value can be accessed through thermostat commands. See sensor literature for additional information. FO ESE OF INSTLLTION ND TOULE SHOOTING DO THE FOLLOWING: Use ategory-5 cable for all communication wiring. heck and recheck to ensure connection to the proper terminals before powering up the thermostats. Use wire color as a guide and be consistent. Use a Distribution Panel on all systems with more than one zone. The trouble shooting benefits will outweigh the cost of the Distribution Panel. DISONNET POWE TO LL HV EQUIPMENT ND/O ZONE ONTOL PNELS If the thermostats are wired to a zone control panel, there is generally one set of input terminals supplying power to the thermostats and dampers. This must be disconnected. If the thermostats are wired directly to HV equipment, the power must be shut off at the equipment. This can generally be accomplished by turning off the disconnect switch located near the equipment. If an obvious disconnect switch is unavailable, you will need to turn the circuit off using the fuse or circuit breaker. emove the fuse or shut down the circuit breaker serving the equipment. UTION Failure to disconnect power could result in damage to the HV equipment or thermostats. Leave power disconnected until all other electrical connections have been made and checked for accuracy. 2

Step 3 UN THE EQUIED S (SEE ILLUSTTION 2) 1. un thermostat cable from each thermostat to the appropriate HV system or zone control panel. Use 4 through 8-conductor thermostat cable depending on the type of equipment and number of equipment stages. un one more wire than would be required if connecting to a mechanical thermostat. If you are using remote temperature or humidity support modules as part of your installation, now is the time to run the additional wires for these items. separate ategory 5 cable must be run from thermostat to support module. 2. t the HV/zone control system, use a piece of tape to label the location of the thermostat on the cable as you go. 3. un ategory-5, 4-pair twisted cable (8-conductor) from each thermostat to the Distribution Panel. 4. t the Distribution Panel, use a piece of tape to label the location of the thermostat on the cable as you go. 5. un ategory-5 wire from the Distribution Panel to the Protocol dapter. If more than one Distribution Panel is used, run ategory-5 wire between each panel. 6. un two-conductor thermostat cable from the Model 8027 Transformer to the Distribution Panel. You can use ategory-5 wire, but you must use one pair of wires per terminal. ILLUSTTION 2 un Wire For System ZONE DMPES 2- THEMOSTT LE SINGLE ZONE HV EQUIPMENT SEE ZONE ONTOL SYSTEM INSTLLTION LITETUE FO OMPLETE ZONE SYSTEM WIING EQUIEMENTS INSTLLTION TIP: USE PIEE OF TPE TO IDENTIFY WHIH THEMOSTT EH LE IS UN TO USE 2- THEMOSTT LE TO ONNET OFF- OD SENSOS SUH S THE MODEL 8051 FLUSH MOUNT SENSO TO SUPPOT MODULES. 2- THEMOSTT LE ZONE ONTOL SYSTEM 1000 FT. MX. SUPPOT MODULE MODEL 8027 PLUG-IN TNSFOME (FO OMMUNITION SYSTEM) 4000 FT. MX. 4000 FT. MX. THEMOSTT 3 THEMOSTT 1 4000 FT. MX. DISTIUTION PNEL 4000 FT. MX. THEMOSTT 2 POWE X TX X TX X TX DT ENLE DT S-485 S-485 S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 4000 FT. MX. THEMOSTT 4 TEGOY 5 (4-PI TWISTED) OMMUNITION NOTE: TOTL DISTNE FOM POTOOL DPTE TO THEMOSTT NOT TO EXEED 4,000 FEET THEMOSTT LE 5 thru 8 ONDUTO 3

Step 4 LOTE ND MOUNT THE UTOMTION SYSTEM OMPONENTS 1. Thermostats and sensors are to be located according installation instructions provided with the units. The thermostat has four configuration dip switches on the circuit board that must be set according to the equipment the thermostat will be controlling. Sensors have six configuration dip switches that must be properly set. The installation manuals provided with the products detail how the switches are to be set. eview the Network Interconnection Worksheet (ILLUSTTION 3) which shows how all the communication components are connected together and write down the location of, or a name for, each thermostat in the system. This will assist in the software set-up. dditional copies are available in the back of this manual. IMPOTNT! THE FEW MINUTES SPENT WITING DOWN THE INFOMTION SUGGESTED IN THESE STEPS WILL SVE TEMENDOUS MOUNT OF TIME DUING THE EST OF THE INSTLLTION. 2. Mount the zone control panel(s) if the HV system(s) is zoned. efer to the zone control panel installation instructions. 3. The prilaire Distribution Panel must be mounted indoors in an accessible location such as a closet or utility room. ll thermostats will be wired to the Distribution Panel, so adequate workspace will be important. There are wire access holes on the top, bottom, sides and back of the Distribution Panel. 4. The Model 8811 prilaire Protocol dapter must be placed within six feet of the host computer or S-232 port of the automation system. The Protocol dapter does not get fastened down. ll the cables and connectors needed to attach the Protocol dapter to the computer or automation system are included with the adapter. 5. The Model 8027 Plug-in Transformer is used to power the communication system. The transformer is wired to the Distribution Panel. Locate this transformer in the same space as the Distribution Panel if possible. 4

ILLUSTTION 3 Network Interconnection Worksheet LOTION DDESS LOTION DDESS LOTION DDESS LOTION DDESS T-5 T-5 T-5 T-5 Fill Out and Leave with System Software Package JO TITLE: JO LOTION: DTE: INSTLLING ONTTO: T-5 DISTIUTION PNEL LOTION / NME T-5 T-5 DISTIUTION PNEL T-5 T-5 T-5 TO DISTIUTION PNEL POWE X TX X TX X TX DT ENLE DT S-485 S-485 S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 LOTION DDESS LOTION DDESS LOTION DDESS LOTION DDESS 5

Step 5 ONNET THE ONTOL S TO THE HV/ZONE SYSTEM ND THEMOSTTS qualified HV technician should perform this step to ensure proper termination. 1. Make sure the HV system power is off. 2. The Thermostat Installation Instructions show wiring diagrams for several different HV equipment types. Use DIGMS 1 & 2 as a reference only. Use color coding where possible. DO NOT TUN ON THE HV SYSTEM POWE YET! DIGM 1 Typical Heating / ool Wiring Schematic MULTI-STGE FUNE 2ND STGE HET FN ELY L2 1ST STG OOL 2ND STGE Y2 OOL W2 1ST STGE OOL Y1 1ST STGE W1 HET 24 V 120 V L1 MULTI-STGE / 2ND STG OOL G Y2 Y1 USE 18-20 G. THEMOSTT LE. NUME OF ONDUTOS EQUIED DEPENDS ON THE HV SYSTEM EING ONTOLLED S S S S EF - + - +.V.-Heat () H.V.-ool (O) G HUM W1 DEH Y1 W2 Y2 UTION! ENSUE HV SYSTEM POWE IS OFF EFOE WIING EFE TO THE THEMOSTT INSTLLTION SHEET FO INTENL SHEMTI, THEMOSTT HEK-OUT POEDUES ND OTHE HV WIING DETILS DIGM 2 Typical Heat Pump Wiring Schematic OUTDOO HET PUMP UNIT USE 18-20 G. THEMOSTT LE. NUME OF ONDUTOS EQUIED DEPENDS ON THE HV SYSTEM EING ONTOLLED EV VLVE HET 1ST STG OMP. UTION! ENSUE HV SYSTEM POWE IS OFF EFOE WIING 2ND STG OMP. Y2 Y1 EV VLVE OOL O DEFOST W1 SEVIE L INDOO LOWE/HET UNIT 2ND STGE UX. HET W2 6 FN ELY L2 1ST STGE UX. HET 24 V 120 V L1 W1 EFE TO THE THEMOSTT INSTLLTION SHEET FO INTENL SHEMTI, THEMOSTT HEK-OUT POEDUES ND OTHE HV WIING DETILS G S S S S EF - + - +.V.-Heat () H.V.-ool (O) G HUM W1 DEH Y1 W2 Y2

OMMUNITION SYSTEM WIING DIGM 3 shows all communication system wiring with terminations. Steps 6 through 8 provide additional detail for each wiring step. DIGM 3 System ommunication Wiring 7.5V XFM Model 8811 POTOOL DPTE POWE X TX X TX X TX DT S-485 ENLE S-485 DT S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 LU/WHT /WHT LU/WHT LU UTOMTION SYSTEM 2- TSTT LE N LU S S S S T1 T2 T3 T4 Model 8051 FLUSH MOUNT SENSO ED/WHT /WHT T-5 Model 8061 O 8062 SUPPOT MODULE 40V XFM + - + - + - + - + - + - + - + - LK/WHT Model 8027 PLUG-IN TNSFOME 24V /WHT LU LU/WHT T-5 + - + - EF FUSE SPE FUSE MIN Model 8818 DISTIUTION PNEL - + - + - + - + - + - + - + - + /WHT LU LU/WHT N /WHT LU LU/WHT N /WHT LU LU/WHT N T-5 T-5 T-5 N N LU LU/WHT LU /WHT N LU/WHT LU /WHT N LU/WHT LU /WHT S S S S EF - + - +.V.-Heat () S S S S EF - + - +.V.-Heat () S S S S EF - + - +.V.-Heat () H.V.-ool (O) G HUM W1 DEH Y1 W2 Y2 Model 8870 THEMOSTT H.V.-ool (O) G HUM W1 DEH Y1 W2 Y2 Model 8870 THEMOSTT H.V.-ool (O) G HUM W1 DEH Y1 W2 Y2 2- TSTT LE Model 8870 THEMOSTT 7

Step 6 ONNET THE OMMUNITION ND POWE S TO THE DISTIUTION PNEL ND THEMOSTT 1. MKE SUE THT LL SWITHES IN THE DISTIUTION PNEL E OFF! 2. onnect the communication wires. DIGM 4 shows how each thermostat is to be wired to the distribution panel. Use the wire colors shown in DIGM 4 to help ensure proper, consistent connections. 3. onnect the EF terminal of each thermostat to the Distribution Panel EF terminals if: More than one transformer is used to power the thermostats in the network Installation is in an environment that has excessive electromagnetic interference from fluorescent lights, motors, or other EMI generating devices, such as in an industrial or office setting DIGM 4 Thermostat ommunication Wiring + - + - + - + - + - EF OMMUNITION TEMINL DEFINITIONS +/- EEIVE (reference automation system) +/- TNSMIT (reference automation system) EF GOUND EFEENE (see Note) THEMOSTT VOLTGE (hot) THEMOSTT VOLTGE (common) /WHT - + - + + - /WHT LU LU/WHT N See NOTE ON EF T-5 N /WHT LU/WHT LU /WHT S S S S EF - + - +.V.-Heat () H.V.-ool (O) G HUM W1 DEH Y1 W2 Y2 NOTE ON EFEENE onnect the EF terminals if: More than one transformer is used to power the thermostats in the network Installation is in an environment that has excessive electromagnetic interference from fluorescent lights, motors, or other EMI generating devices, such as in an industrial or office setting 8

Step 7 ONNET MULTIPLE DISTIUTION PNELS 1. MKE SUE THT LL SWITHES IN THE DISTIUTION PNEL E OFF! 2. If more than one Distribution Panel is used in the thermostat network, the communication lines must be daisy-chained together. Use the wire colors shown in DIGM 5 to help ensure proper, consistent connections. DIGM 5 Multiple Distribution Panels POWE X TX X TX X TX DT S-485 ENLE S-485 DT S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 LU/WHT /WHT ED/WHT LK/WHT LU/WHT LU /WHT T-5 WHEN ONNETING MULTIPLE DISTIUTION PNELS, ONNET THE "EF" TEMINLS FO EH THEMOSTT TO THE "EF" TEMINL OF THE ESPETIVE DISTIUTION PNEL ND ONNET THE EF TEMINLS OF EH DISTIUTION PNEL TO EH OTHE. T-5 /WHT LU LU/WHT /WHT LU LU/WHT /WHT /WHT LU LU/WHT /WHT + - + - EF + - + - EF + - + - - + - + + - + - - + - + DISTIUTION PNEL #1 DISTIUTION PNEL #2 9

Step 8 ONNET POTOOL DPTE TO THE DISTIUTION PNEL ND HOST OMPUTE O UTOMTION SYSTEM 1. MKE SUE THT LL SWITHES IN THE DISTIUTION PNEL E OFF! 2. Use ategory-5 wire to connect the main communication terminals on the Distribution Panel with the Flying Leads of the protocol adapter (see DIGM 6). 3. onnect the S-232 port of the protocol adapter to the computer or automation system. 6 ft. flat cable with J-11 connectors, and an J-11 to D9 transition connector are provided with the protocol adapter. Some computers use 25-pin connectors on serial ports, which requires a D25 connector. D9 connector fits a 9-pin port. D9 to D25 transitions are available at most computer retail stores. 4. Power up the Protocol dapter with the plug-in transformer provided. The Power LED on the Protocol dapter along with the Enable LEDs should light up when power is applied. DIGM 6 Protocol dapter Wiring + - + - 7.5 V Transformer provided w/ protocol adapter POWE /WHT LU X TX DT S-485 LU/WHT LU/WHT /WHT ED/WHT LK/WHT X TX ENLE S-485 X TX DT S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 + - + - EF DISTIUTION PNEL T-5 LU/WHT LU /WHT 1 2 3 4 5 6 ONNETO END VIEW - + - + able and D9 connector provided with protocol adapter FLYING LEDS POTOOL DPTE PIN-OUTS S-485 J-11 ONNETOS S-232 J-11 ONNETO S-485 ONNETIONS SIGNL x+ Tx- Tx+ x- OLO /WHT + ED/WHT - LK/WHT + LU/WHT - 1 NOT USED 2 + 3-4 + 5-6 NOT USED S-232 ONNETION S-232 input to automation system or connect to computer com port 1 - TS: lear to Send (Outgoing - pulled high) 2 - TS: equest to Send (Incoming - ignored) 3 - SG: Signal Ground 4 - D: eceive Data (incoming) 5 - TD: Transmit Data (outgoing) 6 - TS: Data-Set-eady (outgoing - pulled high) 10

Step 9 POVIDE POWE TO THE DISTIUTION PNEL 1. MKE SUE THT LL SWITHES IN THE DISTIUTION PNEL E OFF! 2. Use a 2-wire thermostat cable to connect the load terminals of the Model 8027 Plug-in Transformer to the 24V terminals of the Distribution Panel (see DIGM 3). 3. Plug-in the transformer. 4. NO LEDs ON THE DISTIUTION PNEL SHOULD E ON. Step 10 TUN ON POWE TO LL HV EQUIPMENT ND TO THE THEMOSTTS 1. Turn on power to the HV and/or zone control systems. 2. Go to the Distribution Panel and verify that no LEDs on the Distribution Panel are on. If none are on, proceed to # 3. If any LED is on, immediately unplug the transformer that powers the Distribution Panel. If any LED is on, it is likely that ILLUSTTION 4 Power Switches the HV system transformer is powering the thermostat. Go to the thermostats, remove thermostat from the base and check the wiring. There must be no jumper between the H or + - + - EF and terminal. The ategory 5 cable used to wire communications and power should supply the only wires connected to the thermostat and terminals. 3. Turn on the main power switch then turn on the power switch to one of the thermostats (see MIN ILLUSTTION 4). The green LED 24V next to the power switch should go on, and the corresponding thermostat display should power up. DO NOT TUN ON NY OTHE SWITHES. Step 11 HEK-OUT HV SYSTEM OPETION + - + - + - + - 4. One by one, turn on only the power switches (not the communication switches) for each thermostat. Verify that the green LED comes on and that the thermostat display powers up. Use the thermostat buttons to verify that the thermostat is controlling the equipment operation. checkout procedure is supplied in the installation instructions with the thermostat. This procedure will verify only that the thermostat operates the equipment. ommunication system checkout will be performed next. FUSE - + - + - + - + Each thermostats power LED lights when the switch is turned on 11

Step 12 DDESS THE THEMOSTTS ND SET HIGHEST DDESS IMPOTNT! THESE STEPS MUST E DONE T EH THEMOSTT FO OMMUNITION TO WOK POPELY. 1. Press the Mode and Enter buttons simultaneously through the thermostat. It may take a couple of tries to get them pressed together. This will enter the Thermostat Set Up Menu. The first menu item that will appear on the message center display is an informational item that indicates that only the Scroll Up, Scroll Down (two buttons located immediately to the right of the message center display) and the Enter buttons are used in thermostat set up. This will remain on the display for approximately 5 seconds or until any of the three aforementioned buttons is pressed. Thermostat Set Up is a series of sub-menus available to customize the thermostat in various ways. The thermostat Owners Manual and Installation Manual outline the thermostat set up features. The following steps will guide only through the ommunications Set Up sub-menu (see ILLUSTTION 5). ILLUSTTION 5 Setting the Thermostat ddress 2. Press the Scroll Down button until the ommunications Set Up menu shows on the display. 3. Press the Enter button to select this sub-menu. 4. The first sub-menu item is Set Thermostat DDESS. Press the Enter button to select this item. 5. Set the address between 1 and 64 using the Scroll Up and Scroll Down buttons. (If using Model 8840 thermostats, see ppendix 1.) Each thermostat must have a unique address (i.e. no two thermostats can have the same address) Start with address 1 and increment by 1 for each new address do not skip an address. This will help to speed communications. Write down the address for each thermostat on the Network Interconnection Worksheet (see ILLUSTTION 3). 6. fter the address has been selected, press the Enter button to store the address. 7. Use the Scroll Up and Scroll Down buttons to set the Number of Stats On Network to the highest address that will be on the thermostat network. This will be equal to the total number of thermostats on the network, unless one or more addresses are skipped. IMPOTNT! THIS NUME MUST E SET THE SME T EH THEMOSTT 8. fter setting the number of thermostats on the network press Enter. The next item will be to Set UD ate. The thermostat defaults to 9600 baud (bits per second). If you want to change to 19200 baud operation, continue with #9. If you want to operate at 9600 baud, press the Scroll Down button to get to the EXIT screen for the ommunications Set Up sub-menu and go to #10. 9. Press Enter to set the baud rate. Use the Scroll Up or Scroll Down button to toggle between 9600 baud and 19200 baud. Press Enter when the baud rate desired is showing. 10.Press Enter to EXIT the ommunications Set Up sub-menu. This will return you to the main menu. 11.Press the Scroll Down button until EXIT is displayed. Press the Enter button. The thermostat will then reset and return to normal operation. 12

Step 13 SETUP OMPUTE FO OMMUNITION SYSTEM HEKOUT 1. onnect the Protocol dapter S-232 output to a computer with Windows 95, 98, Windows 2000 or Windows NT. This may already have been done in Step 7. 2. Turn on the computer. 3. From the Start menu, select POGMS ESSOIES OMMUNITION HYPETEMINL (see ILLUSTTION 6). HyperTerminal is a terminal emulator program provided with Windows that will be used to test the communication system. ILLUSTTION 6 ccess HyperTerminal If you now have the HYPETEMINL folder available, skip the next step and go to #6. 4. If the OMMUNITIONS or HYPETEMINL folder is not present, you will need to add this program to your Windows setup. From the Start menu, select SETTINGS ONTOL PNEL, then select (double click) the dd/emove Programs icon. Select the Windows Setup tab, and place a in the ommunications component box. This will add HyperTerminal to your Windows setup. Go back to #3 and get into the HyperTerminal folder as described. 5. Double click the Hypertrm icon. You will then be asked to name the new connection and select an icon. Type in any name you want (the shorter the better) and select the atom-like symbol at the end of the Icon list (see ILLUSTTION 7). Then click OK. ILLUSTTION 7 New onnection 13

6. This will bring up a onnect to dialog box. From the pull down next to onnect using:, select the om port to which the Protocol dapter is connected (see ILLUSTTION 8). Start with om port 1 (or the next lowest available number) if you are unsure which one to use. lick OK. ILLUSTTION 8 Select om Port 7. OM1 Properties dialog box should appear. Use the pull-down menus or type in the following for each selection (see ILLUSTTION 9): its per second: 9600 (or 19200 if thermostats are configured for this baud rate) Data bits: 8 Parity: None Stop bits: 1 Flow control: none lick OK. ILLUSTTION 9 onnection Properties 14

8. From the File pull-down menu, select Properties. This will bring up a Properties dialog box. 9. Select the Settings tab. Make the following selections (see ILLUSTTION 10): Terminal keys trl+h Emulation: uto Detect Telnet terminal: NSI ackscroll buffer lines: 500 ILLUSTTION 11 SII Setup ILLUSTTION 10 Terminal Settings 10.Then select the SII Setup button. This will bring up an SII Setup dialog box. Make the following selections (see ILLUSTTION 11): Echo typed characters locally ppend line feeds to incoming line ends Wrap lines that exceed terminal width NOTE: 1. IF USING N EXISTING HYPETEMINL ONNETION YOU MY NEED TO UNHEK THE SEND LINE FEEDS OX. 2. THE MODEL 8870 HS N EXPNDED OMMND SET. EFE TO DP 10004345 FO THE MODEL 8840 SEIES OMMND SET. 11.lick OK to put away both dialog boxes. 12.Verify that you have a connection between the computer and the Protocol dapter. Have the Protocol dapter within eyesight of the computer keyboard. Type any character and confirm that the S-485, Data, TX LED and the S-232, Data, X LED (see DIGM 6 on page 10) on the Protocol dapter flash as you type. The LEDs flash very quickly. 13.Press Enter to clear the command line. Note: On Windows 98 computers, HyperTerminal does not echo typed characters (doesn t show them on the screen as you type) locally. Do not be concerned. This can be a little confusing, but does not affect the checkout of the thermostat communication system. If you were unable to verify a connection, specify a different com port. Go to the File pull down menu, and select Properties. hange the onnect using: setting to a different port by using the pull down menu options. Start typing and look for the Protocol dapter LEDs to flash. epeat until you have successfully verified connection between the computer and communication system, or until you run out of com ports to choose from in the onnect using: pull down. If there is still no communication you are going to have to consult a computer professional. 15

Step 14 HEK-OUT OMMUNITIONS TO THE THEMOSTT NETWOK 1. t the computer type SN? (it does not matter if it is small or capital letters) then press Enter. You should get no response because none of the communication switches to the thermostats have been turned on yet. 2. Go to the Distribution Panel and turn on the communication switches for the thermostat with address #1 (see ILLUSTTION 12). 3. Type SN? and press Enter. The computer should respond SN1. This indicates that the thermostat with address #1 is communicating. If no response, type in SN? and press Enter again. If it still does not appear, go to the Distribution Panel make sure the communication switches for the thermostat with address #1 are on. If the SN response contained a number other than one, the communication switches you turned on were for an address other than number one. Now is the time to verify that the thermostat names/locations match the addresses shown on the Network Interconnection Worksheet (ILLUSTTION 3). There is room on the Distribution Panel label (on the inside cover of the Distribution Panel enclosure) to write the address and thermostat name with the corresponding terminal connections. 4. Type SN ID? and press Enter. The computer should respond SN1 MODEL# 8870 EV: Vx.x - P 2002; where x.x represent the current firmware revision level. This is done to determine if the communication is robust. The large amount of data being transmitted by the thermostat may be corrupted if there is interference on the communication lines. If the response is not exactly as shown, there is a communication signal problem. The most likely sources are a loose terminal connection, incorrect wire type, damaged wire, electrical interference or incorrect power supply. Look at all the terminal connections and look at the wire where the insulation was stripped. If the wire appears kinked, trim the wire and carefully strip the insulation. lso, make sure the wires connected to the thermostat and terminals is connected to the corresponding Distribution Panel and terminals for that particular thermostat. If this doesn t help, connect the EF terminal of all the thermostats to the two EF terminals on the Distribution Panel. 5. Go to the Distribution Panel and turn off the communication switches for address #1 and turn on the communication switches for address #2. 6. epeat this process to verify communications to all thermostats one address at a time. Each time you turn on the communication switches to a new thermostat, a new SN number should respond. If this is not the case, go to the thermostats and address them as indicated in Step 12. 7. Finally, go to the Distribution Panel and turn on all the communication switches. 8. Type SN ID? then press Enter. ll thermostats should respond as shown in #4. Make sure the number of responses equals the number of thermostats in your system, and that the responses are complete and accurate. 9. Once you have successfully completed this procedure you have verified that proper communication exists between the computer and all of the thermostats. To test out all of the functions of the thermostat, use the software or automation package being installed with this system. You can check out other thermostat functions using HyperTerminal: go to the prilaire ommand Set section on page 19. ILLUSTTION 12 om Switches + - + - + - + - EF - + - + LED flashes when communications are transmitted LED flashes when communications are received 16

ppendix 1 SPEIL ONSIDETIONS FO INSTLLING THE MODEL 8870 WITH THE 8840 SEIES OMMUNITING THEMOSTT If adding a Model 8870 thermostat to a system using 8840 series thermostats (8844, 8846, 8847 or 8848), you must change the power supply installation, modify the addressing method and remove terminating resistors from the Model 8811 protocol adapter. 1. separate power supply is required for Model 8870 thermostats and 8840 series thermostats. This requires different wiring. If using a Model 8800-8808 ommunication Panel, see DIGM 7 for wiring schematic. If using a Model 8818 Distribution Panel you must use the 8840 series thermostat with an 8809 Sub-base to allow S-485 communications to be connected directly to the Distribution Panel. See DIGM 8 for wiring schematic. NOTE: 1. IF USING N EXISTING HYPETEMINL ONNETION YOU MY NEED TO UNHEK THE SEND LINE FEEDS OX. 2. THE MODEL 8870 HS N EXPNDED OMMND SET. EFE TO DP 10004345 FO THE MODEL 8840 SEIES OMMND SET. DIGM 7 dding an 8870 Thermostat MODEL 8870 THEMOSTT Model 8027 PLUG-IN TNSFOME IMPOTNT! YOU MUST USE SEPTE POWE SUPPLY FO 8870 THEMOSTT(S). T-5 8800-8808 MODEL OMMUNITION PNELS N LU LU/ WHT / WHT 4 ON OFF ON OFF 24V ON ON 24Vc OFF O L K D 2/ Y ON OFF ON OFF OFF N LU/WHT LU /WHT 8 S S S S EF - + - +.V.-Heat () ommunication ard H.V.-ool.-ool (O) G HUM W1 DEH Y1 W2 Y2 IMPOTNT! YOU MUST DDESS 8840 SEIES THEMOSTTS HIGHE THN NY MODEL 8870 THEMOSTT ON THE NETWOK. LK1 LK2 S2 S1 S+v Model 8027 PLUG-IN TNSFOME 1 2 Y2 W1 Y1 G 24V 24V(c) W2 8840 SEIES THEMOSTT 2- TSTT LE 485 SEIL IN O L K D ON ON OFF OFF POWE 24V UTION! TUN LL DISTIUTION PNEL SWITHES OFF EFOE DOING NY WIING. 17

DIGM 8 dding an 8840 Series Thermostat MODEL 8870 THEMOSTT UTION! TUN LL DISTIUTION PNEL SWITHES OFF EFOE DOING NY WIING. + - + - + - + - 40V XFM MODEL 8818 DISTIUTION PNEL 24V 2- TSTT LE FUSE MIN 40V XFM Model 8027 PLUG-IN TNSFOMES - + - + - + - + /WHT LU LU/WHT N /WHT LU LU/WHT 2- TSTT LE N T-5 T-5 LU MODEL 8809 OMMUNITING SU-SE /WHT LU/WHT N ED LK LU N LU/WHT LU /WHT ommunication ard IMPOTNT! YOU MUST USE SEPTE POWE SUPPLY FO 8840 SEIES THEMOSTTS. S S S S EF - + - +.V.-Heat () YEL/LU ED LK MODEL 8848 SHOWN LK1 LK2 S2 S1 S+v 1 2 H.V.-ool.-ool (O) G HUM W1 DEH Y1 W2 Y2 Y2 W1 Y1 G 24V 24V(c) W2 IMPOTNT! YOU MUST DDESS 8840 SEIES THEMOSTTS HIGHE THN NY MODEL 8870 THEMOSTT ON THE NETWOK. 2. IMPOTNT! When addressing the thermostats, the Model 8870 thermostat(s) must either be the first addresses on the network, or there must be one address skipped between 8840 series thermostats. For example, if one Model 8870 thermostat were to be added to an existing four 8840 series thermostat network then the 8870 thermostat must be addressed #1 or #6. hange the existing address #1 to be #5 and add the 8870 as address #1, or simply add the new thermostat as address #6. IMPOTNT: Set Number of Stats On Network to 32 and Set UD ate to 9600. 3. Unplug the Model 8811 Protocol dapter power supply and S-232 connection. emove the four screws securing the cover to the base. emove the pin jumpers (shunts) labeled JP9 (see ILLUSTTION 13 for relative location). eplace the shunts on just one of the pins. ILLUSTTION 13 emove Terminating esistors POTOOL DPTE WITH OVE EMOVED JP9 Place these 2 jumpers on just one pin J11 onnectors 18

ppendix 2 PILIE OMMND SET SN# [ommand] [? or =] [Value (use with = only) ] Enter full command set and detailed explanation of the command set is available for those who want to write their own software. ontact esearch Products orporation at 888-782-8638 to request a copy of DP 10005756. Upper or lower case letters may be used for all commands. Invalid characters will immediately invalidate a command, so the use of backspace or delete is not allowed (applies mainly when interacting with the thermostat using HyperTerminal). ll commands will begin with the characters SN. Immediately following the SN, without any intervening spaces (blanks), will be the address (#) from 1 to 64 of the Model 8870 Thermostat with which you are communicating. Single digit addresses may be sent as a two digit address with a leading zero. Omitting the address, or using a 0 (zero) in place of a space makes the command global, and all connected thermostats will respond. Following this initial command sequence, spaces may be inserted at this point only, for clarity between commands. The next portion is the command or variable [ommand]. The table on page 20 describes the basic commands. The next portion [? or =] is the action to be performed:? corresponds to state your value while = corresponds to set your value. Spaces are allowed between the command and the action. The final portion, [Value], is used only if a command or variable is to be set. The value must follow the action with no intervening spaces. carriage-return Enter is used as the terminator for the command string. Line feeds (LF) should not be sent with commands as this is a recognized SII character and invalidates any command received between the line feed and the next carriage return. EXEPTION: The command SN? or SN0? will respond with all connected thermostats returning their address. OMMND ESPONSE SYNTX The Model 8870 will respond by supplying the information requested or by confirming the completion of an action command. The response syntax is generally the same as that used for commands, but no spaces separate command, action or value. esponses are sent in upper case SII format. Should a command not be recognized, no response will be forthcoming there is no EO message. Unless otherwise noted as ead Only or Write Only, all commands are ead and Write. Inquiries can be made with all commands (with the exception of LTON) to determine the existing value of a variable. Inquiry is done using the following syntax: SN [address number, or <blank> or 0 (zero) for global] OMMND?; where command is the variable whose value is desired. 19

OMMND DESIPTION VLUE ommunication ontrol ommands ommand esponse ontrol Silent / Quiet / Normal 1 hange of State (OS) HV relays ON/OFF 2 OS Temperature ON/OFF 3 OS emote Temperature ON/OFF 5 OS Set Points ON/OFF 6 OS Network Override ON/OFF 7 OS Mode ON/OFF 8 OS Fan ON/OFF HOLD User Hold Status ON / OFF NME Location Name <String> ID eport Model No. and software rev. ead Only Thermostat Sensing ommands SLE ommand Temperature Scale F / (Fahrenheit/elsius) TEMP, T eport Thermostat oom Temperature ead Only HUM eport Thermostat oom Humidity ead Only (requires humidity control sensor) SM Identify all external sensors connected ead Only to a thermostat s local communication network xsy eport value of any sensor on thermostat s ead Only (x = 1-4; y = 1,2) local communication network OT eport Thermostat emote Outdoor Temperature ead Only eport Thermostat emote Outdoor Temperature ead Only OH eport Thermostat emote Humidity ead Only Thermostat HV Operational ommands MODEL 8870 SI OMMND SET SH Heat Mode Set Point Two or three digit integer: 40 88 for F; 4 31 for SH++ Increment heat set point Integer value which when added to the current heat set point does not fall outside the SH limits SH-- Decrement heat set point Integer value which when deducted from the current heat set point does not fall outside the SH limits S ool Mode Set Point Two or three digit integer: 42 90 for F; 6 33 for S++ Increment cool setpoint Integer value which when added to the current cool set point does not fall outside the S limits S-- Decrement cool setpoint Integer value which when deducted from the current cool set point does not fall outside the S limits S urrent Mode Set Point Two or three digit integer (see next two commands) SP++ Increment current mode set point Integer value which when added to the current mode set point does not fall outside the SH and S limits SP-- Decrement active setpoint Integer value which when deducted from the current mode set point does not fall outside the SH and S limits MODE, M Thermostat Mode of Operation / /H /E/OFF (uto/ool/heat /EMHT/Off)Humid/Dehum when operating as a humidity controller FN, F Fan Switch Setting /ON (uto/on) HV, H eport HV elay States ead Only uxiliary Information ommands EQUIPONFIG eports the setting of the thermostat ead Only configuration dip switches LTON Turns on backlighting for 10 seconds. No Value equired for this ommand 20

LOTION DDESS LOTION DDESS LOTION DDESS LOTION DDESS T-5 T-5 T-5 T-5 Fill Out and Leave with System Software Package JO TITLE: JO LOTION: DTE: INSTLLING ONTTO: T-5 DISTIUTION PNEL LOTION / NME T-5 T-5 DISTIUTION PNEL T-5 T-5 T-5 TO DISTIUTION PNEL POWE X TX X TX X TX DT ENLE DT S-485 S-485 S-232 Model 8811 Protocol dapter Power 7.5V S-485 S-485 S-232 LOTION DDESS LOTION DDESS LOTION DDESS LOTION DDESS 21

DP 10005754 1.5.4.02 1015 E. WSHINGTON VE. MDISON, WI 53703 PHONE: 888/782-8638 FX: 608/257-4357 www.aprilaire.com