REGTRONIC OPERATING INSTRUCTIONS



Similar documents
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Conductive Level Switch FK 2 Technical Data:

LCD Readout Digital Pressure Switch

PTU Series Transducer Digital Display Indicator User s Manual

Electronic Pressure Switch EDS 300

How to read this guide

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

Transmitter Interface Program

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

F453. TiF453. User guide 10/11-01 PC

Multifunction devices

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Inwall 4 Input / 4 Output Module

Panel Meters and Controllers Modular Panel Meter Type EDM 35

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

RAINCONTROL LCD Special

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

zamak nitrile rubber self-extinguishing technopolymer aluminum

EVAL-UFDC-1/UFDC-1M-16

Sierra S-Series Smart Interface Software User Manual

Combi switchbox with integrated 3/2 way pilot valve

Single channel data transceiver module WIZ2-434

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

D-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

AC-115 Compact Networked Single Door Controller. Installation and User Manual

OEM-EP Pressure Controllers

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Proportional pressure regulators VPPE

Single sub-base valve

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

INSTALLATION MANUAL XM3 Reader

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

MotorData. Car diagnostics made easy. MotorData Client Software User Manual

PPM Users Manual Signature Software

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

ViZion Installation Guide

Installation manual. Version

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Ordering Part Numbers:

SenseLink TM. End-Point Controller. Addendum

Vibration Monitoring System Adash 3600

Application/Connection Examples

Limited Service Fire Pump Controllers Features

Programmer/Controller

PowerShield SNMP Adaptor

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700

Business/Home GSM Alarm System. Installation and User Manual

RF Etch Monitor. Introduction

K-Type Thermocouple Sensor User s Guide

Software User Guide UG-461

NC-12 Modbus Application

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

WD-AMX Water Detection Controllers

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Controller Automation, Model II+

Color Mark Sensor with Red or Green LED E3S-VS

4/2-Way Pneumatic Solenoid Valve

Proximity Switches RS (Reed Switch)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

zamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool

Bluetooth HC-06 with serial port module Easy guide

PM1122 INT DIGITAL INTERFACE REMOTE

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

RN-XV-RD2 Evaluation Board

PHONE MANAGER INDEX. page

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

W150: Miniature photoelectric switch series with completely integrated electronics

T3 Mux M13 Multiplexer

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

PIEZOMETER AIRFLOW MEASURING RING

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

MANUAL PC1000R

Digital Keypad Use s Manual

Transcription:

REGTRONIC OPERATING INSTRUCTIONS

1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure: FS+ at least 1 bar, max 11 bar 24Vdc power supply IP65 index of protection LED indicating pressure achieved and digital output active Graphical display and keypad to display the pressure, unit of measurement and parameter setting. 0-10 V analog output signal 2. SETTINGS Press and together to access the setting menu. Select the parameter using the arrow keys. Press to return to the previous page. During setting, pressure regulation is NOT active. 2.1 2.1.1LANGUAGE Italiano English Deutsch Español Français Select LANGUAGE using the arrow keys, then press. Select the desired language using the arrow keys, then press 2.1.2 UNIT OF MEAS. bar PSI MPa Select UNIT OF MEAS. using the arrow keys, then press Select the desired unit of measurement using the arrow keys, then press 2.1.3 CONTRAST Manual display contrast adjustment Select CONTRAST using the arrow keys, then press. Select the value using the arrow keys, then press. Compensation as a function of temperature is automatic. 2.2 2.2.1 INPUT 0 / 10 V 0 / 5 V 4 / 20 ma RS232 Keypad Select INPUT using the arrow keys, then press. Select the type of input using the arrow keys and then press. For the type of analog input (0/10V-0/5V-4/20mA), use an appropriate analog signal. For the type of RS232 input, use the communication protocol described in chapter 12. For the type of keypad input, set the pressure value using the arrow keys. When you press the display buttons, the set pressure appears; when you release them, the preset pressure is displayed. 2

2.2.2 DEADBAND This indicates the pressure range in proximity to the set pressure, within which regulation is active. The deadband is + and - the set value. It is advisable to enter low values, 10 or 15 mbar, only if high regulation accuracy is required. High accuracy involves more work for the solenoid valves. + BM SET - BM Regolation ON Regolation OFF Regolation ON Select DEADB using the arrow keys, then press. Enter the value using the arrow keys, then press. 2.2.3 FULL SCALE This indicates the maximum preset pressure. The analog command is divided over the Full Scale. The analog output signal indicates that the preset pressure is 0-10V for 0-10 bar. Examples with maximum preset pressure 3, 5 and 10 bar 10 V (20 ma) Set [volt] 10 Out analogico 5 3 0 (4 ma) 3 5 10 FS bar 0 3 5 10 [bar] For optimal regulation, the feed pressure must be FS + 1 bar 2.2.4 RS232 Enables serial transmission, irrespective of the type of input. 3

2.3 DIGITAL Two digital outputs are available, one PNP and one NPN. They can be configured independently as normally open or normally closed. The P ON (P+) and P OFF (P-) activation/deactivation thresholds are unique. 2.3.1 PRESSURE SWITCH CONFIGURATION (P) P ON P OFF Select using the arrow keys, then press. Select CONFIGUR. to select the operating mode, then press. Select PRESSURE SWITCH, then press. PRESSURE SWITCH mode, shown with CONFIGUR. P. has been selected. Use the arrow keys to select PRESSURE SWITCH and press. Select P ON and press. Enter the desired activation pressure and press. Select P OFF and press. Enter the desired deactivation pressure and press. Press to exit the menu. ON OFF 2.3.2 SET (S)REFERENCE This function can be used to make a "variable" setting for the pressure switch. Out is activated when the preset pressure is reached, with a tolerance defined by P+ and P-. SET OUT OFF OUT ON OUT OFF P+ PRESSURE P- Select using the arrow keys, then press. Select CONFIGUR. to select the operating mode, then press. Select SET. REF and press. SET REFERENCE mode, shown with CONFIGUR. S. has been selected. Use the arrow keys to select PRESSURE SWITCH and press. Select SET.REF and press. Select P+ and press. Enter the upper tolerance pressure and press. Select P- and press. Enter the lower tolerance pressure and press. Press to exit the menu. 2.3.3 TYPE OF CONTACT This function is used to identify whether the digital output is normally open or normally closed. Select TYPE OF CONTACT and click. Select TYPE PNP or TYPE NPN, click and enter the type of contact. Click to exit. 2.4 Serial number Software version Hour counter: indicates the operating time in hours. 4

2.5 Utility used for checking correct operation of the two solenoid valves. P IN P OUT Select and press. Select PIN and press. The in solenoid valve activates and the pressure increases. Press. The in solenoid valve deactivates and pressure stabilizes. Select POUT and press. The out solenoid valve activates and pressure decreases. Press, the out solenoid valve deactivates and pressure stabilizes. bar P 2.6 PASSWORD This is a three-digit code used to protect the set configuration. Select with the arrow keys and click. On the setting page, use the arrow keys to enter the desired value and click to confirm. The system then displays the confirmation message "PASSWORD SAVED. Select PASSWORD and click to enable/disable the function. If the password set to ON, it prevents access to the configuration menu. When you press + together to access the configuration menu, you are prompted to enter the password. Enter the saved password. You can use the arrow keys to change the value or click to change the field. If the password is set to OFF, it is not enabled. If you forget the password, contact the manufacturer to obtain a password reset code. 3. ACCESS TO THE MENU Press to display the set parameters. Press and together to access the parameter setting menu. Use the up and down arrows to scroll through the menu and modify the parameters. PRESSURE 7.00 bar OUT SET PARAMETERS INPUT 0/10 V UNIT MEAS. BAR P DEAD BAND 0.050 F SCALE 7.5 LANGUAGE ITA T= 40.5 C PC ON SERIAL NO 00100 SW VERS 03.01 ITALIANO GERMAN ENGLISH SPANISH FRENCH + LANGUAGE ENG UNIT MEAS. BAR CONTRAST 40 bar MPa PSI CONTRAST 40 5

3. ACCESS TO THE MENU INPUT 0/10 V DEAD BAND 0.050 F. SCALE 10.0 PC ON 0/10V 0 / 5 V 4 / 20 ma RS232 KEYPAD DEAD BAND 0.050 bar F.SCALE 10.0 bar INPUT 0/10 V DEAD BAND 0.050 F. SCALE 10.0 PC OFF PRESS.SWITCH RIF. SET CONFIGUR. PRESS.SWITCH RIF. SET CONTACT TYPE P PON 7.0 POFF 5.0 PON 7.0 bar POFF 5.0 bar P+ 2.0 P- 1.0 P- 1.0 bar P+ 2.0 bar TYPE PNP TYPE NPN NO NO TYPE PNP TYPE NPN NC NO 6

SERIAL NO 00010 SW VERS. 03.01 H.-METER 00001 PIN 0 POUT 0 PIN 0 POUT 0 PIN 1 POUT 0 PIN 0 POUT 1 PIN 0 POUT 0 PIN 0 POUT 0 PASSWORD ON 10.00 bar PASSWORD PASSWORD - - - 1 - - PASSWORD 12 - PASSWORD 123 SALVATA PASSWORD 123 7

4. TECHNICAL DATA 1/8 1/4 Fluid MIN inlet pressure bar MAX inlet pressure bar Temperature range C Pressure regulation range Flow rate at 6.3 bar ΔP 0.5 Nl/min Flow rate at 6.3 bar ΔP 1 Nl/min Exhaust flow rate at 4 bar with 0.1 bar overpressure Nl/min Exhaust flow rate at 4 bar with 0.5 bar overpressure Nl/min Installation position Weight gr Class of protection Power supply Input signal (input impedence) Voltage Current Serial ports Manual Output signal Analog Digital Linearity Hysteresis Repeatability Sensitivity/Dead-band Output pressure display Analog output accuracy Temperature characteristics Response time with ΔP 1 bar and with 100 cc volume Accuracy Unit of measurement Minimum resolution Filtered, unlubricated air. The air must be filtered at at least 10 μm Regulation pressure +1 bar 11 0 50 0.05 10 bar (settable full scale) 770 1490 1050 1700 320 500 650 1200 in any position 380 385 IP 65 24 Vcc ± 10% I max 110 ma 0 5 Vcc, 0 10 Vcc (approx. 168 KΩ) 4 20 ma (approx. 100 KΩ) RS 232 Keypad 0 10 Vcc (1 V=1bar) - 1 ma max PNP open collector output: max 24V 60 ma NPN open collector output: max 24V 60 ma ± 0,5% (Full scale) ± 0,2% (Full scale) ± 0,2% (Full scale) setting range 10 100 mbar ± 0,3% (Full scale) bar, Mpa, PSI 0.01 bar - 0.001 MPa - 0.01 PSI ± 0,4% (Full scale) max 2 mbar / C 0.2 sec N.B. The features shown refer to the static condition only. With air consumption on the output side, the pressure may vary. 5. INSTALLATION AND OPERATION 5.1 PNEUMATIC CONNECTION Pneumatic connection is via the threaded holes in the body. It is important for the regulator pressure not to exceed 11 bar and the compressed air to be filtered at 10μ and dried, to prevent impurities or excessive condensate from causing a malfunction. The supply pressure must always be higher than the preset pressure. The regulator pressure must be at least 1 bar higher than the full scale value. If a silencer is mounted on the outlet, the flow rates and response times may vary. Check the silencer periodically for clogging and replace if necessary. 5.2 ELECTRICAL CONNECTION This is by means of M12 female circular 8-pin connector (to be ordered separately). Refer to the wiring diagram below. Wrong connections may permantenly damage the regulator. 8 5.2.1 CONNECTOR PIN CONFIGURATION 1 = TX (RS232) (WHITE) 2 1 2 = RX (RS232) (BROWN) 3 = set 0-10 V / 0-5 V / 4-20 ma (GREEN) 3 (YELLOW) 8 4 = digital out 0-24 V NPN 5 = analog out 0-10 V (GREY) 4 6 6 = digital out 0-24 V PNP (PINK) 5 7 = 0 V (GND) (BLUE) (RED) 8 = power supply +24V Regulator connector colours' sequence in compliance with viewed from above Metal Work prewired connectors. 7

5.2.2 DIGITAL OUT CONNECTION Pin 4 NPN Digital OUT PNP Digital OUT Pin 6 LOAD LOAD +24 V 0 V 5.3 OPERATING PRINCIPLE Using a software algorythm, the control circuit compares the input signal with the output pressure measured by the pressure sensor. When there is a change, it activates the inlet and outlet solenoid valves to re-establish an equilibrium. This gives an output pressure that is proportional to the input signal. N.B.: removing the power supply, the outlet pressure doesn t get discharged 5.3.1 FUNCTION DIAGRAM FEED INPUT SIGNAL CONTROL CIRCUIT SIGNAL INLET SOLENOID VALVE OUTLET SOLENOID VALVE P PRESSURE SENSOR IN OUT 6. FLOW RATE CHARACTERISTICS 10 1/8 1/4 ON EXHAUST ON REGULATION ON EXHAUST ON REGULATION 10 9 9 8 D 8 D 7 C 7 C Inlet pressure [bar] 6 5 4 B Inlet pressure [bar] 6 5 4 B 3 A 3 A 2 2 1 1 0-1800 -1600-1400 -1200-1000 -800-600 -400-200 0 200 400 600 800 1000 1200 Flow rate [Nl/min] A = 2.5 bar C = 6.3 bar B = 4 bar D = 8 bar 0-1800 -1600-1400 -1200-1000 -800-600 -400-200 0 200 400 600 800 1000 1200 1400 1600 1800 Flow rate [Nl/min] 9

7. TROUBLESHOOTING PROBLEM The display does not come on The unit does not respond or responds wrongly to the setpoint The unit does not reach the desired pressure The display shows an unreal value The display is difficult to read. The unit adjusts continually. Other problems. POSSIBLE CAUSES No 24V power supply. Wrong input signal configuration. Setpoint too low The full-scale setting is at a lower pressure than desired The supply pressure is too low Wrong unit of measurement. Poor contrast. Air leak in the circuit after the unit Continuous variation in volume Deadband too small Contact the manufacturer SOLUTION Check the power supply, make sure it is enough and check the wiring is in accordance with the wiring diagram Configure the appropriate type of input from the menu Check the signal wire is connected to the right pin Provide a suitable setpoint Set the full scale correctly Increase the supply pressure Check the unit of measurement. Adjust the contrast. Eliminate the leak Normal behaviour; the unit has to keep adjusting the maintain the preset pressure Increase the deadband 7.1 LIST OF ALARMS ALARM +V NPN DOUT SHORT-CIRCUIT ALARM 0V PNP DOUT SHORT-CIRCUIT ALARM LOW VDC ALARM 0V P. INP SHORT-CIRCUIT ALARM 0V P. OUT SHORT-CIRCUIT ALARM P. INP DISCONNECTED ALARM P. OUT DISCONNECTED ALARM ANALOG SET ALARM PRESSURE OUT OF RANGE ALARM POSSIBLE CAUSES NPN output to power supply unit has shortcircuited PNP output to earth has shortcircuited Supply voltage below 18V Supply solenoid valve has shortcircuited. Drain solenoid valve has shortcircuited. Fill solenoid valve disconnected. Drain solenoid valve disconnected. Occurs with 4/20 ma input when the current exceeds 23mA. Downstream pressure exceeds 10200 mbar. SOLUTION Eliminate the cause of the shortcircuit. Switch the unit off and back on again to reset the alarm. Eliminate the cause of the shortcircuit. Switch the unit off and back on again to reset the alarm. Increase to a sufficient voltage Switch the unit off and back on again. If the alarm persists, contact the manufacturer. Send the unit a correct input signal. Switch the unit off and back on again the reset the alarm. Check to see if the drain is blocked. The alarm resets automatically when the pressure drops below the threshold. 10

8. SERIAL COMMUNICATION PROTOCOL Communication protocol can be used to configure and control the regulator via an PC serial port. To activate serial communication, set the RS232 to ON on the set-up page. The communication protocol is 2400 8 N 1 (8 bits, no parity, 1 stop bit) and the commands are in ASCII format. All commands are the following type: cnnnnn where (Escape) prepares the unit to receive commands, c is the command and nnnnn is the associated parameter, the length of which depends on the actual command. The available controls are shown herewith below Set Unit of measurement Sets the unit of measurement. The command is the following type: cn Where n = 0 = pressure in bar 1 = pressure in MPA 2 = pressure in psi If n is not one of these values, the unit does not change. Set type of input Sets the type of control.the command is the following type: dn Where n = 0 = 0-10V input 1 = 0-5V input 2 = 4-20mA input 3 = keypad input 4 = serial input If n is not one of these values, the type of control does not change Set Deadband Sets the deadband. The command is the following type: bnnn Parameter nnn must always be 3 digits. The value must be expressed in mbar. Set Full Scale Sets the full scale. The command is the following type: Ennnnn Parameter nnnnn must always be 5 digits. The value must be expressed in mbar (e.g. E7000, the set full scale is 7000 mbar). Digital output configuration Sets the type of digital output and the activation/deactivation values. The command is the following type: O1sssssxxxxx where: 1 = type of output (0 = pressure switch 1 = reference) sssss = output activation threshold xxxxx = output deactivation threshold Parameters s and x must always be 5 digits. The value must be expressed in mbar. 11

Set Pressure Sets the pressure to reach. The command is the following type: Pnnnnn Parameter nnnnn must always be 5 digits. The value must be expressed in mbar (e.g. P01001, the set pressure is 1001 mbar). Read preset pressure Displays the preset pressure value. This command requires no parameters. It is the following type: p The response is: pnnnnn Parameter nnnnn represents the pressure in mbar (e.g. p05600, the preset pressure is 5.60 bar) Read configuration Displays a string with complete module configuration. This command requires no parameters. It is the following type: i The expected response is: i05322b050c0d2e10000o10500002000 where: 05322 = the pressure reading 050 = the deadband (b = the set deadband code) 0 = the unit of measurement (c = the set unit of measurement code) 2 = type of control (d = the set type of control code) 10000 = the full scale (E = the code) 1 = type of output (0 = pressure switch 1 = reference) (O = the code) 05000 = output activation threshold 02000 = output deactivation threshold The type of parameter is indicated before the value, except for pressure. 8.1 SERIAL CABLE CONNECTION DIAGRAM M12 connector 9-pin D-Sub connector Pin 1 (TX) Pin 2 Pin 2 (RX) Pin 3 OV Pin 5 12 IM01-07/2009