MVX-Series Diesel Engine Air Shut Down Valves



Similar documents
MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

SELECTION, APPLICATION & MAINTENANCE

SELECTION, APPLICATION & MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

World proven safety solutions for diesel engines

SELECTION, APPLICATION AND MAINTENANCE

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Toroidal Conductivity Sensor

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Operators manual Basic water heater

Baumann Way Bronze or Stainless Steel Control Valve

Coolflo Safe Touch Shower Mixing Valve ST20015CP

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

Original Assembly Guide

Diesel Engine Exhaust Spark Arrestors Selection, Application and Maintenance

INSTALLATION INSTRUCTIONS BL-8704

Turbocharger system components, servicing

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

INSTALLATION INSTRUCTIONS MK-8704

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

PRESSURE REDUCING CONTROL VALVE

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Installation Instructions

Assembly and instructions

Front axle components, overview

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

Stainless Steel Single and Dual Circulation Kits

REMOVAL AND INSTALLATION

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

K17.11 DOOR BOLTS K17 DOORS

Installation Instructions S

Givare NC-SRS 280 och 880

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

6 Crankcase Ventilation

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

MANDATORY SERVICE BULLETIN

How To Order A Direct Flow Air Cleaner

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Model 43AP Pneumatic Controller, Style B

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

kymanual or Automatic - it s your Choice

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Saferand easierinstallation

F-Series Camera Mounting Accessories

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

High Flow Air Cleaner Assembly

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Rack installation instructions

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Proportional pressure regulators VPPE

V47 Series Temperature Actuated Modulating Water Valves

Installation Instructions

FIRE FIGHTING MANUAL AND REMOTE-CONTROLLED. Simple cabling just 2 power lines. Common Electronic Optimal reach

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flow rates

Triac Printed Circuit Board Replacement

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

Stainless Steel Valves For the Sanitary Industries

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Richter Twin Piston Quarter-turn Actuators

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

COUNTERBALANCE VALVES

STABITHERM INSTALLATION & SERVICE BOOKLET

INSTALLATION INSTRUCTIONS

EC DECLARATION OF CONFORMITY FOR MACHINES

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Installation, Maintenance, & Repair Series 4000B/LF4000B

How To Replace A Reverse Osmosis Water Tank

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Electromagnetic Flow Meter

Hose and Tube Fittings Series 1-3

Fixtures - Parts - Accessories to shampoo bowls

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Transcription:

MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303 but with twin pull cables. The installation and maintenance instructions given for MVX-303 are otherwise generally applicable. Valve Numbers MVX-301 MVX-302 MVX-303 MVX-501 MVX-502 MVX-503 MVX-801 MVX-802 MVX-803 CE248 (4) MVX_0509

DESCRIPTION a range of mechanically actuated diesel engine air intake closure valves based on standard Chalwyn 3, 5 and 8 butterfly valves. suitable for both hazardous and non-hazardous area applications where a cable operated stop control combined with a valve mounted reset lever is required. available in basic flange mounted form or fitted with hose adaptors or an integral flame trap housing. Body and disc manufactured in corrosion resistant hard anodised aluminium with PTFE coating. spindle and mechanism made from 316 stainless steel. Typical Arrangement: Valve Types MVX-301, MVX-501 and MVX-801 PUSH Type Stop Button Reset Lever Optional Hose Adaptors Cable Length Options - see under Selection A B C1 C2 (min) C2 (max) Typical Arrangement: Valve Types MVX-302, MVX-502 and MVX-802 PUSH Type Stop Button Reset Lever Cable Length to suit installation A Cable Length Options - see under Selection Optional Hose Adaptor (one each side) C1 C2 (min) C2(max) B 2 MVX ValVEs CE 248 (4)

Typical Arrangement: Valve Types MVX-303, MVX-503 and MVX-803 PULL Type Manual Stop Reset Lever A Cable Length Options - see under Selection Optional Hose Adaptor (one each side) C1 C2(min) B C2(max) Main Dimensions (mm) Valve Types Nominal Bore Diameter A B C 1 C 2 minimum & maximum MVX-301 MVX-302 MVX-303 76 (3 ) 190.0 190.0 223.0 111.5 37.5 82.5 to 112.5 MVX-501 MVX-502 MVX-503 127 (5 ) 246.0 246.0 279.0 167.0 45.5 102.0 to 157.5 MVX-801 MVX-802 MVX-803 203 (8 ) 346.5 346.5 377.5 257.0 56.0 136.5 to 185.5 Note: Maximum temperature of the engine intake air at the MVX valve not to exceed 150 C. (see also Installation - page 5). 3 MVX ValVEs CE248(4)

SELECTION Determine the size and position of the MVX valve to be installed. Within the various constraints imposed by the application, the valve should be as generously sized as possible Check that the valve can be positioned such that the reset lever will be easily and safely accessible and that a reasonably straight run is available for the shut down cable. select the cable length required from the options listed below. Remote Push Button and Cable options for use with PULL Cable Assembly Options (to suit valves Handle RTD-100 (To suit valves MVX-301/302, MVX-501/502 or MVX- MVX-303, MVX-503, or MVX-803) 801/802) assembly part No. length (meters) RBC--100 1.0 RBC-150 1.5 RBC-200 2.0 RBC-300 3.0 select the required length of the manual shut down cable from the table. alternative lengths may be available on request. Cable part No. length (meters) ClD-100 1.0 ClD-150 1.5 ClD-200 2.0 ClD-300 3.0 select the required length of the manual shut down cable from the table. alternative lengths may be available on request. also order handle RTD-100. If the valve is to be fitted into a hose as opposed to flange mounted, suitable hose adaptors may be selected from the table below for ordering with the valve. Hose Adaptor Options 76mm (3") Bore Valves adaptor To suit Hose Bore Part Number mm (inches) HaX-320 38 (1 1 / 2 ) HaX-322 44.5 (1 3 / 4 ) HaX-301 51 (2) HaX-302 54 (2 1 / 8 ) HaX-303 57 (2 1 / 4 ) HaX-304 60 (2 3 / 8 ) HaX-305 63.5 (2 1 / 2 ) HaX-306 67 (2 5 / 8 ) HaX-307 70 (2 3 / 4 ) HaX-308 73 (2 7 / 8 ) HaX-309 76 (3) HaX-312 82.5 (3 1 / 4 ) HaX-314 89 (3 1 / 2 ) HaX-319 102 (4) 127mm (5") Bore Valves adaptor To suit Hose Bore Part Number mm (inches) HaX-501 89 (3 1 / 2 ) HaX-502 92 (3 5 / 8 ) HaX-503 95 (3 3 / 4 ) HaX-504 98 (3 7 / 8 ) HaX-505 102 (4) HaX-506 105 (4 1 / 8 ) HaX-507 108 (4 1 / 4 ) HaX-508 111 (4 3 / 8 ) HaX-509 114 (4 1 / 2 ) HaX-510 117.5 (4 5 / 8 ) HaX-511 121 (4 3 / 4 ) HaX-512 124 (4 7 / 8 ) HaX-513 127 (5) HaX-518 140 (5 1 / 2 ) HaX-523 152 (6) 203mm (8") Bore Valves adaptor To suit Hose Bore Part Number mm (inches) HaX-807 178 (7) HaX-808 203 (8) 4 MVX ValVEs CE 248 (4)

INSTALLATION 1. In the case of a naturally aspirated engine, the Chalwyn MVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an intake flame trap is also fitted, the MVX valve must be installed upstream (air cleaner side) of the flame trap. 2. To avoid excessively high intake air temperatures at the MVX valve when fitted to a turbocharged engine, it may be necessary to fit the MVX valve either upstream of the turbocharger or downstream of the intercooler (where fitted). again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. 3. Where more than one MVX valve is installed on an engine, as in the case of an engine with multiple intake pipes, the shut down valves must be arranged to all close simultaneously. intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. 8. For values with the pull handle cable operated manual shut down, fit the T handle assembly RTD-100 through a suitable Ø20mm (3/4"dia) hole in a bulkhead or mounting bracket as follows. Release the handle locknut. Remove the handle,handle locknut and upper locknut and washer. Thread handle body through the bulkhead/bracket. Refit upper locknut and washer. adjust lower and upper locknuts to position handle and tighten. Refit handle locknut and handle. Tighten locknut. 4. The valve may be installed either horizontally or vertically. 5. If hose adaptors are used, the mating hose should be of a reinforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 6. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. The possibility of a hose collapse on closure of the shut down valve must be avoided. 7. any engine crankcase breather connections into the intake system between the MVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine T HANDLE HANDLE LOCKNUT BULKHEAD or MOUNTING BRACKET HANDLE BODY STOP CABLE UPPER LOCK NUT LOWER LOCK NUT 5 MVX ValVEs CE248(4)

OPERATION Prior to starting the diesel engine, the MVX valve must be latched open by rotating the reset lever clockwise as far as possible. Once latched, the reset lever will remain in the latched open position until manually released by the remote stop button. To carry out an emergency closure of the MVX intake valve to stop the engine, operate the manual stop control. No attempt should then be made to restart the engine until the MVX valve is again latched open. MAINTENANCE MONTHLY: Check that the fasteners locating the MVX valve and any associated intake systems or support bracket fasteners are securely tightened. Check that any flexible hoses between the MVX valve and engine are free from damage and suitable for further service. Run engine, preferably at low idle. Operate the stop button. The engine should stop within a few seconds. If not, check that the shut down cable is properly adjusted and that there are no leaks in the intake system between the MVX valve and the engine. If this does not resolve the problem, remove the MVX valve and return to Chalwyn for further investigation. 6 MVX ValVEs CE 247 (4)

7 MVX ValVEs CE247(4)

Chalwyn by AMOT www.chalwyn.com a division of Roper Industries limited UK Western Way Bury st Edmunds suffolk, IP33 3sZ Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 USA 8824 Fallbrook Drive Houston TX 77064 Tel: +1 (281) 940 1800 Fax: +1 (713) 559 9419 CHalWyN REsERVEs THE RIgHT TO update THIs PRODuCT specification WITHOuT PRIOR NOTICE.