IntesisBox KNX LG Air Conditioning



Similar documents
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

KNX Panasonic Air Conditioners

IntesisBox KNX Mitsubishi Heavy Industries AC

Modbus Server SAMSUNG Air Conditioners

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox KNX Modbus RTU master

IntesisBox KNX - LON

IntesisBox KNX Modbus TCP master

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server Fidelio IP

IntesisBox ASCII Server - LON

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Inwall Room Temperature Unit

IntesisBox DK-RC-KNX-1

Electronic Control Devices The European Product Catalogue 2007

IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines

Telephone- and leased line modem for industrial applications TD-36

Rack mounted telephone- and leased line modem for industrial applications

TX OPEN RS232/485 module

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic Control Devices The European Product Catalogue 2007

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

User manual Compact Web PLC WP240 series IEC-line

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

1 Serial RS232 to Ethernet Adapter Installation Guide

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

OZS Web server. For LPB/BSB plants

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

KNX Interface. User Manual PM00A00IRI

Product and Application Description

PCS0100en Persy Control Services B.V. Netherlands

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

One Port Serial Server Users Manual Model ESP901, ESP901E

Waveguide Access Point WGA631. Product Guide

I STAR COMPUTER CO., LTD

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

FX07 Field Controller

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Model: DC-A2IO Advanced HVAC Controller

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA RF/RF High Single

ABB i-bus EIB Logic Module LM/S 1.1

Energy Communication Unit (ECU)

Loop-IP6702 TDMoEthernet

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Inwall 4 Input / 4 Output Module

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

IntesisBox ME-AC-ENO-1C

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Unidirectional Transmitter/ Receiver Units Introduction

PowerCommand iwatch 100

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PXM20-E. Operator unit DESIGO PX

Research RF Sputtering Packages

Product and functional description

ewon COSY 141 Installation Guide

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Cisco TelePresence MSE 8000

Digital input modules

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

RRV934. Multi-controller. Synco living

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

Remote Monitoring and REC 501 Control Unit Product Guide

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Thyristor-controlled power supplies and battery chargers

Uninterruptible Power Supply

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

TrueAlarm Fire Alarm Systems

HARTING mcon 1000 Introduction and features

Loop-IP6510 Multiple WAN Router/Bridge

HMI display Installation Guide

HARTING econ 3000 Introduction and features

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

EDI Distributor Control Interface Wiring and Setup Instructions

BridgeWay Fixed Base Radio Telecom VoIP Gateway

ABB i-bus KNX Fan Coil Controller FC/S 1.1

RY2 miniature industrial relays

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Energy Communication Unit (ECU)

Product Information DBT-CEV CHARGING SOLUTIONS FOR ELECTRIC VEHICLES CATALOGUE

Transcription:

IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit s EIA485 bus. Simple configuration using the software LinkBoxEIB supplied with the purchase of IntesisBox with no additional cost. Integrates 1 LG Air Conditioners in your KNX projects. Four models available: o Ref. LG-AC-KNX-4, with capacity of up to 4 indoor units. o Ref. LG-AC-KNX-8, with capacity of up to 8 indoor units. o Ref. LG-AC-KNX-16, with capacity of up to 16 indoor units. o Ref. LG-AC-KNX-64, with capacity of up to 64 indoor units. Configuration Software LinkBoxEIB (Only needed for configuration) RS232 IntesisBox LG-AC-KNX-4 LG-AC-KNX-8 LG-AC-KNX-16 LG-AC-KNX-64 Figure 1.1 Typical System integration using the IntesisBox KNX LG AC 1 This integration requires in some cases additional cards installed in the outdooor units of the LG AC system, the model of additional card will depend in each case of the line of indoor units used (see details in the figure above). 1 / 5

2. Configuration Software: LinkBoxEIB LinkBoxEIB Visual engineering tool, easy of use, for IntesisBox s configuration and monitoring compatible with Microsoft Windows operating systems, supplied with the purchase of IntesisBox. Multi-window tool allowing to monitor simultaneously the communication activity with both protocols (systems), real time values for all the points allowing to modify any value (very useful for test purposes), console window showing debug and operation status messages, and configuration windows to configure all IntesisBox s parameters and points. Point's configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the IntesisBox s parameters and points while in off-line (not connected to the IntesisBox). Connection to the IntesisBox for download the configuration and monitoring by using serial COM of the PC (serial cable also supplied). Allows configuring all the external protocols available for IntesisBox KNX series. Upgrades for this software tool available free of charge whenever a new version or feature is available. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox KNX series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. 2 / 5

3. LG to KNX integration Property EIS type Signal type Description / Status (R/W) On / Off Start/Stop AC/VENT Unit 0 OFF, 1 ON Mode AC Mode 0 COOL, 1 HEAT, 2 DRY, 3 FAN, 4 AUTO Mode (VENT unit) 0 NORMAL, 1 HEAT EXCHANGE, 2 AUTO Mode::Cool 0 Inactive, 1 Active Only one of these objects will Mode::Heat 0 Inactive, 1 Active be set / read to 1 at the Mode::Dry 0 Inactive, 1 Active same time (all objects will be updated on bus upon a Mode Mode::Fan 0 Inactive, 1 Active change) Mode::Auto 0 Inactive, 1 Active Setpoint Temperature EIS 5 Float (2byte) R/W Temperature Set Point (only integer numbers allowed) 16..30 ºC Ambient Temperature Swing EIS 5 Float (2byte) R Ambient Temperature (only integer numbers) Read: 10ºC to 40ºC AC Swing 0 Stop, 1 Start Fan Speed AC Fan Speed 0 AUTO, 1 LOW, 2 MID, 3 HIGH FanSpeed::Auto 0 Inactive, 1 Active Only one of these objects will FanSpeed::Low 0 Inactive, 1 Active be set / read to 1 at the same FanSpeed::Mid 0 Inactive, 1 Active time (all objects will be updated FanSpeed::High 0 Inactive, 1 Active on bus upon a Mode change) Remote Restriction Error Sign Error Code Filter Alarm 10 Counter (16bit) R/W Remote Control Enablement / Disablement 0 Remote control enabled, 1 Remote control disabled Error Code / Communication error with the Indoor Unit 0 No error present, 1 Error code present, or communication error with the indoor unit Error Code More info in User Manual Filter Alarm Status 0 No alarm, 1 Filter alarm present Filter Alarm Reset 1 Switching (1bit) W (This parameter is not applicable for AC units) Filter Alarm Reset Write: 1 Filter alarm reset (This parameter is not applicable for AC units) 3 / 5

4. Technical characteristics Envelope Plastic type PC (UL 94 V-0). Size: 107mm x 105mm x 58mm. Color Grey. RAL 7035. Power 9 to 30VDC +/-10% 1.4W. 24VAC +/-10% 1.4VA. Power connector is a 2 pole plug-in screw terminal block. Mounting options Wall DIN rail EN60715 TH35. KNX (EIB) 1 x KNX TP1 (EIB) opto-isolated (Plug-in screw terminal block 2 poles) RS485 (LG) 1 x RS485 connector (Plug-in screw terminal block 2 poles) LED indicators 1 x Power. 2 x KNX activity (Tx, Rx). 2 x RS485 (Tx, Rx). 1 x KNX programming/bus. 1 Push buttons 1 x KNX programming. Console RS232. DB9 female connector (DCE). Configuration Via console. 2 Firmware Allows upgrades via console. Operational -40 C to +70 C temperature range Operational 5% to 95%, non condensing humidity range Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Certifications CE 1 Not operational for the moment. Reserved for future use. 2 Along with the device it is also supplied a standard DB9 male - DB9 female 1.8 m. cable for configuring and monitoring the device using a PC via serial COM. The configuration software, compatible with MS Windows operating systems, is also supplied. 4 / 5

5. Dimensions Power RS485 / LG KNX 58 mm Console 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections: 100 mm 115 mm 130 mm 5 / 5