David C. Barrow Elementary School 100 Pinecrest Drive, Athens, GA 30605



Similar documents
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

POST AND FRAME STRUCTURES (Pole Barns)

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Seattle Public Schools Building Excellence IV Projects Under Construction

Chapter 6 ROOF-CEILING SYSTEMS

CPA Steel Stud Framing Page 1 of 11

Saint Cloud Business Center

Technical Assignment 2 TABLE OF CONTENTS

Vertex BD. Leading Software Solution for Cold Formed Steel Construction

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Building Condition Assessment: North Howard Street Baltimore, Maryland

REQUEST FOR BOARD ACTION HENDERSON COUNTY BOARD OF COMMISSIONERS. ATTACHMENTS: 1. Construction Management Update

Expected Performance Rating System

8/18/14. Introduction to. Framing. Terminology and Concepts

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

ABOUT CWB CERTIFICATION/ QUALIFICATION The work CWB does on behalf of our clients can be divided into five main categories:

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Basic Requirements for Residential Plan Review _

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Page & Turnbull imagining change in historic environments through design, research, and technology

Residential Building Permits

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Mark Cramer Inspection Services, Inc.

Structural Assessment Report

MULTI-RESIDENTIAL BUILDING SOLUTIONS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

Code of Standard Practice for Timber Frame Structures

Slavic Village Building Condition Review

PDmB, Inc. Definitions

Building Condition Assessment: West Lexington Street Baltimore, Maryland

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

ESSENTIAL CURRICULUM ARCHITECTURAL DESIGN ACADEMY

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

How To Design A Post Tensioned Deck For A Building

Scope of EN Clarification Document

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Additions and Alterations

Chapter 3 Pre-Installation, Foundations and Piers

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute

EAST LYME HIGH SCHOOL

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

WEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204

Olilo's AEC Design Services. SrinSoft Inc, Partners of

Construction Technologies Career Field Pathways and Course Structure

PART 1 GENERAL 1.1 SECTION INCLUDES

Connection Solutions

Project Report. Structural Investigations Hotel del Sol Yuma, Arizona

Photos showing the change in condition from 2006 to 2012 are located in Appendix A.

6 RETROFITTING POST & PIER HOUSES

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Facility Assessment for East Main Street, Huntley, IL

COMMONLY USED RESIDENTIAL BUILDING CODES

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

START STRONG. THE SUMMIT

3rd Annual Design Drafting Contest

Timber Frame Construction

Contractor s Statement of Responsibility for Seismic-Force-Resisting Systems This form is to be filled out by the contractor.

MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

14 September Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste St. Paul, MN 55102

TIMBER FRAME STANDARD DETAILS SEPTEMBER 09

WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Property Inspection. 83A Ascot Avenue North New Brighton Christchurch STRUCTURAL REPORT

Elevating Your House. Introduction CHAPTER 5

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Design Development Quality Management Phase Checklist Project Phase Checklist Series

A Homeowner s Guide to Building Permits

17,280 square feet Overview:

Marketing Coordinator Bootcamp Session 2: ABCs of AEC

GYPSUM AREA SEPARATION FIREWALLS GA

EARTHQUAKE DESIGN OF BUILDINGS

ISO Types 1-6: Construction Code Descriptions

Patio Covers / Carports

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

LIGHT FLOOR AND WALL FRAMING

Commercial And Industrial Steel Buildings

Construction Technology COURSE OUTLINE

RENOVATION AND RESTORATION OF OLD BUILDINGS IN SRI LANKA

TechPractices: Home Front Homes:

Engineered Wood Foundations

Building Construction. Lightweight construction. Conventional Construction

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Lesson Plan Course Title: Construction Technology

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

INFORMATION BULLETIN NO.

Transcription:

David C. Barrow Elementary School 100 Pinecrest Drive, Athens, GA 30605 Winner of the 2014 Cold-Formed Steel Engineers Institute (CFSEI) Design Excellence Award May 2014 The David C. Barrow Elementary School provides facilities for elementary school education from pre-kindergarten through Grade 5. The original structure was built in 1923 from wood framing with brick veneer. Over the years, the school had undergone several renovations and additions, but in 2010, the school district decided that the aging structure needed a major overhaul. The options included: 1) completely closing and relocating the school, 2) completely demolishing the old school and building a new one, or 3) renovating the existing building and providing a major addition. The project team decided to go with the third option, as long as the relocation of the students would only last for one school year. Photo by SP Design Group The design and construction challenges posed by the architectural demands of renovating rather than building a new school, the one-year timeframe for construction, and the budget requirements of the Clarke County School District provided unique solutions that only cold-formed steel (CFS) could provide. The school was completed in summer 2013. 1

Scope of the Project The project scope was two-fold: 1) to renovate the portion of the building which housed the administrative offices and classrooms for pre-kindergarten through first grade, and 2) to construct a new two-story addition that included classrooms for second through fifth grades, a media center, specialty classrooms, a gymnasium, and a new dining facility. Cold-Formed Steel is Chosen for Cost-Competitiveness and Innovation Panelized CFS framing was chosen as the primary structural material for the addition and as both primary and secondary structural material for the renovation. DSi Structures and network partner Odom Construction fabricated and installed the CFS materials, while DSi Engineering provided the design and panel drawings. Renovations to the original section included new CFS framed partitions, ceilings, and a new entry/reception area with both loadbearing and non-loadbearing cold-formed steel walls, columns and rafters. The new two-story addition is loadbearing CFS panelized construction. The floor system for the second story is composite concrete with open web bar joists, bearing directly on the CFS panels. All panels have 100% welded Loadbearing panelized CFS walls in front of existing brick structure under renovation. Load distribution members negated the need for alignment framing. Composite headers reduced framing above the openings. Photo by DSi Structures connections. Shear walls are made from X-braced CFS prefabricated panels, both along the central corridor and in the demising walls between classrooms. Abuseresistant gypsum sheathing was used for the classroom and hallway areas. The roof is framed with CFS trusses at 4 feet on center. At either end of the new addition are masonry structures housing the food preparation and dining facility on one end, and the gymnasium on the other. The loadbearing masonry walls support CFS trusses one story at the kitchen area, and two stories at the gymnasium area. All trusses are framed from back-to-back C- shaped webs and chords. Although several other construction types were considered for the two-story classroom addition, loadbearing CFS was not only price-competitive, but also allowed the project to be completed in time for the opening of the 2013-2014 school year. Design innovations such as composite beams with the poured concrete slabs, load 2

distribution members, special alignment techniques for the shear walls, and composite slabs with bar-joists allowed the loadbearing steel portion of the project to be completed in only a few weeks. The Design and Construction Process Working with the design team, DSi Structures, DSi Engineering, and Odom Construction coordinated both construction and schedule to meet the owner requirements for construction timeframe and classroom appearance. Shear resistance was provided by CFS strapping welded to both bearing panels and partitions. Strap braced walls were shop fabricated and bolted in place. Photo by DSi Structures Through its in-house software program development firm DSi Digital, DSi Structures used its proprietary Intelli- Model software to integrate the panel design with the architectural and structural design. Using 100% Building Information Modeling (BIM) technology, the panels and shear walls were laid out in 3D along with the composite floor system using Ecospan floor joists. The innovative DSi header system allowed for combined use of the slab turn-down, along with the composite CFS top-of-wall load distribution member, to provide the most efficient header design both during the concrete pour and after the concrete reached full design strength to carry live and other loads through the system. This BIM layout and panelization allowed for clash detection and prevention, as well as integration with plumbing and HVAC. Headers at the top of the wall rather than directly above the openings allowed for ductwork to penetrate the non-bearing cripple studs above doors rather than requiring special box-outs or headers. The panels were fabricated on compression jig tables and all connections were welded, which allowed for ease of handling and accuracy in panel construction. Stud fabrication machinery was coordinated with the structural design. All materials were cut-to-length to eliminate waste both on-site and in the shop. The panels were quickly dropped into place, plumbed, braced, and the next panel was ready to set in a matter 3

of minutes. The CFS design team considered construction and safety issues and provided design of the OSHA-required safety rails and safety harness tie-off points on the CFS panel system. Solving Complex Problems Design coordination allowed for very few complexities in both the design and construction. However, the design and construction of the curved front entry and rafters for the entry roof did provide some challenges, since this area was not pre-panelized, and member lengths and angles varied around the radius. This portion was field-framed and thus produced the largest amount of scrap for the entire structure, but was still less than typical wood or non-cfs projects. Design Integration Trusses were shop fabricated from back to back unpunched C Because of the flexibility of the CFS sections: all members cut to length, out of the stud fabrication bearing system, no design changes were machine, with very little scrap. Photo by DSi Structures needed to accommodate the CFS system. In addition, the CFS wall system and composite joist floor system were integrated so that alignment issues were avoided. All bearing panels incorporated load distribution members to eliminate alignment and coordination problems between trusses, bearing floor joists, and wall framing. The alignment framing required by AISI S200, North American Standard for Cold-Formed Steel Framing General Provisions, was negated by both the load distribution members and preplanning where heavy joist and truss loads would fall. School s in Session The teamwork exhibited by the members of the design and construction teams, combined with the innovations and inherent durability, straightness and quality of CFS framing, enabled the Clarke County School District to complete the project on time and under budget. The team gets an A+ from the children and the community for creating a safe, attractive and economical learning environment. 4

Project Participants and Further Information Project Owner: Clarke County School District Ted Gilbert, Associate Superintendent for District Services Athens, GA Ph: 706.546.7721, ext. 18264 Email: gilbertt@clarke.k12.ga.us Project Architect of Record: Larry N. Pope, AIA SP Design Group, Architects and Engineers Macon, GA Ph: 478.477.7465 Email: larry@spdesigngrp.com Engineer of Record for Structural Work: Thad Gilliam, P.E., LEED AP BD+C Principal, GW Design Group, LLC Atlanta, GA Ph: 770.457.0065 Email: TGilliam@gwdesigngroup.com Construction Manager: David Moore, President Piedmont Construction Group, LLC Macon, GA Ph: 478.405.8907 Email: dmoore@piedmontconstructiongroup.com Cold-Formed Steel Specialty Engineer: Steve Haddad, P.E. Vice President, DSi Engineering, LLC Norcross, GA Ph: 770.375.4511 Email: shaddad@dsi-engineering.com Cold-Formed Steel Specialty Contractor: Danny Odom Chief Operating Officer, Odom Construction Systems, Inc. Knoxville, TN Ph: 865.579.5015 Email: danny.odom@odomconstruction.com 5

For More Information: Maribeth Rizzuto, LEED AP BD+C Managing Director, Cold-Formed Steel Engineers Institute Director, Education and Sustainable Construction, Steel Framing Alliance 25 Massachusetts Avenue NW, Suite 800 Washington, DC 20001 Tel: 800-79-STEEL or 412.921.1060 Email: MSRizzuto@aol.com 6