Direct Attach Cable with Micro Coaxial Wire for Data Center



Similar documents
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

Communication, Signal & Data Cables

High Speed Cables for Enterprise Data Solutions Business Unit Telecommunication Systems

Coaxial Cables for Medium-Frequency Applications

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

Quick Reference Guide High Speed Input/Output Solutions

LOW LOSS CABLE PAG. 1

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

75 Ω Transmission System

XFP Optical Receiver, 80km Reach

MYTHBUSTING Takes on Shielded Cabling

MICROCABLES. A complete vision of your connectivity needs. Catalogue

The ABC of Direct Attach Cables

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

How to Choose the Right Cable Category

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

10/100/1000BASE-T SFP Transceiver

RX-AM4SF Receiver. Pin-out. Connections

I-PEX MHF4 Micro Coaxial Connector

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Cable Analysis and Fault Detection using the Bode 100

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

ELECTRICAL CHARACTERISTICS OF LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) INTERFACE CIRCUITS PN May 2000

AMP CO Plus Insert for Cat. 6 A Applications

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Datacenter Performance

Wideband Driver Amplifiers

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

Networks. The two main network types are: Peer networks

Ethernet Patch Cord Wiring

PRODUCT SPECIFICATION

Subject: Glenair MIL-PRF Conduit Surface Transfer Impedance Test

GaAs Switch ICs for Cellular Phone Antenna Impedance Matching

Feasibility of 25 Gb/s Serial Transmission Over Copper Cable Assemblies

Specification SFTP CAT6 Network Cable 23AWG CU

with Component Rating A Simple Perspective

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?

Data Communications Competence Center

Twinax Intra Pair Skew Comparison Report Various Lengths and Competitors Tested

Uniprise Solutions COAX 101. White Paper.

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

Measurement Results of 3m QSFP-to-4SFP Breakout Cable for Non-FEC 25Gbps/lane Server Connections

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

GORE Aerospace Cables

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

LONGLINE 2km XFP Optical Transceiver

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3

Introduction to Digital Subscriber s Line (DSL)

STRANDED AND SOLID CONDUCTOR

Intel Ethernet SFP+ Optics

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Broadcast and Commercial AV Cabling MASTER CATALOG

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

TECHNICAL SPECIFICATION

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Signal Types and Terminations

X2 LR Optical Transponder, 10Km Reach

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Optical Interconnect Technology for High-bandwidth Data Connection in Next-generation Servers

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

21/03/2013 Center Cable, S.L Camino del Barranco,4-6 P.I. Las Arenas de Pinto Pinto (Madrid) Tlf

Copper Patch Cords. Impact On Network Performance and Reliability

EECC694 - Shaaban. Transmission Channel

HARAX circular connector

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

Times Microwave Systems Hermetically Sealed Assemblies

INTERNATIONAL STANDARD

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

10GBASE -LRM, 220m Reach GX LRMC

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

LOXONE 12 Channel Amplifier

11. High-Speed Differential Interfaces in Cyclone II Devices

Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.

Transcription:

FEATURED TOPIC Direct Attach Cable with Micro Coaxial Wire for Data Center Yasuhiro MAEDA*, Kensaku SHIMADA, Yuki ISOYA, Tatsunori HAYASHISHITA and Michiko HARUMOTO ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- In data centers, direct attach cables with twinax wire have been used to date in order to avoid defects such as skew. However these cables have drawbacks of being thick and hard. In the background of a recent trend of the rack highly dense with switches and servers, which is common in many data centers, there is a growing need for thin and flexible cable that provides better wiring operation and heat dissipation for intra-rack wiring of up to 3 m. Sumitomo Electric Industries, Ltd. developed novel thin and flexible direct attach cables (SFP+ and QSFP+) by using the advanced micro coaxial wire technology cultivated through information appliance products. ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Keywords: direct attach cable, micro coaxial wire, SFP+/QSFP+, data center 1. Introduction With the rapid increase in the use of mobile information devices such as smart phones and tablets in recent years, data traffic on the Internet is exploding, and data centers to support data traffic are increasingly important. With this background, the data transfer rate and the server density per rack in data centers are increasing. Currently, a data transfer rate of 1 Gb/s between a switch and a server in the rack is becoming predominant, and devices to support a data transfer rate of 4 Gb/s are becoming available. Direct attach cables, such as Small Form Factor Pluggable Plus (SFP+) and Quad Small Form Factor Pluggable Plus (QSFP+), are mainly used as media to support high transfer rates between these devices in the rack. Conventionally, twinax wire* 1 with a high skew performance has been mainly used for direct attach cables. However, since conventional direct attach cables are thick and hard, there is an increasing need for thin and flexible cables for high-density rack wiring of up to 3 m that offer ease of installation and operation and high heat dissipation performance. To meet this need, we have successfully developed direct attach cables (SFP+, QSFP+) that are thinner and more flexible than conventional ones, using our advanced micro-coaxial wire* 2 technology, which we have developed for information appliance products. This report presents the outline of the design of the cables and their characteristics, as well as the evaluation results of the characteristics of SFP+ and QSFP+ using the developed cables. 2. Brief Description of the Direct Attach Cables Table 1 briefly describes the developed direct attach cables. SFP+ and QSFP+, which are the form factor for transfer rates of 1 Gb/s and 4 Gb/s (4 1 Gb/s), respectively, are connected to a cable terminal. Generally, the diameter of conventional 1 m SFP+ and QSFP+ twinax cables is more than 4 mm and 6 mm, respectively. The diameter of the 1-m micro-coaxial cables is small, with 3.2 mm for SFP+ and. mm for QSFP+. Table 1. Outline of the direct attach cables Form factor SFP+ QSFP+ Transmission rate 1 Gb/s 4 Gb/s Compatible standards 1GSFP+Cu (SFF-8431) 4GBASE-CR4 (IEEE82.3) QDR (Infiniband) Number of cores in cable 4 cores (2 pairs) 16 cores (8 pairs) Cable diameter Wire gauge External view 3.2 mm (1m) 3.6 mm (3m) AWG34 (1m) AWG32 (3m). mm (1m) 6.4 mm (3m) AWG34 (1m) AWG3 (3m) 3. Brief Description of the Cable Design 3-1 Cable design and construction Figure 1 shows the cross sections of the developed cables. SFP+ and QSFP+ are for 1-lane bidirectional signal transmission and for 4-lane bidirectional signal transmission, respectively, and have 4 cores (2 pairs of wires) and 16 cores (8 pairs of wires) in the cable. 3-2 Transmission characteristics of the cables The skew is one of the most important parameters that affects the signal transmission characteristics of cables. SFP+ and QSFP+ use the differential signal transmission method. The skew is the time difference after signal transmission between positive and negative signals in the transmission of differential signals. A differential signal is defined as the voltage difference SEI TECHNICAL REVIEW NUMBER 8 APRIL 21 21

2 N = 64 SFP+ Braided shield Jacket QSFP+ Braided shield Jacket Filler 2 1 1 Fig. 1. Cross section of the cables 1 2 3 4 6 7 8 9 1 Skew [ps/m] between the positive and negative signals. Therefore, the magnitude of the skew affects the voltage difference (differential amplitude). That is, the magnitude of the skew affects the signal transmission characteristics of the cable in proportion to the frequency of the signal. It is important in controlling the skew to reduce the difference in characteristics between two coaxial wires to make them a pair as much as possible. More specifically, it is necessary to make the physical length and signal delay time of the two coaxial wires as equal as possible. For example, for a 1-m cable, a skew of 4.7 ps/ m occurs if there is a difference in length by only 1 mm between the two coaxial wires (because the average signal delay time of the coaxial wire is 4.7 ns/m). We reduced the effect of flattened shape or non-perfect circular cable shape on the difference in the physical length as much as possible by arranging coaxial wires concentrically and making a pair of two adjacent coaxial wires to reduce the difference in the physical length when making a multi-core cable. As the signal delay time (Td) is given by Td = dielectric constant/speed of light, the difference in the dielectric constant of the insulation material covering the center conductor of the coaxial wire directly affects the skew. Since the dielectric constant is specific to a material, selection of an insulation material is certainly important. To aim at a skew of less than 1 ps/m required for a transmission rate of 1 Gb/s, a variation in the small air layer between the center conductor and the insulation material cannot be ignored. We focused on the variation in the air layer and achieved a low skew in a coaxial construction by stably controlling the variation in the longitudinal direction. Figure 2 shows a typical example of the skew of differential pair wires in an SFP+ (1 m) cable using the developed micro-coaxial wire. Figure 3 shows a typical example of insertion loss. The skew is to 6 ps/m at a maximum and low enough for a transmission rate of 1 Gb/s, or signal transmission at a signal interval of 1 ps per bit. The insertion loss of the coaxial wire is similar to that of the twinax wire. In addition, the coaxial wire shows no significant attenuation in a specific frequency range called suck-out, which appears in conventional twinax wires. Similar results to the SFP+ (1 m) cable shown in the figure were obtained for other cables shown in Table 1. Insertion loss [db/m] 1 1 2 2 Fig. 2. Typical skew Twinax wire 3 1 1 2 Fig. 3. Typical cable insertion loss 3-3 Mechanical properties of the cables Table 2 shows the results of a flexibility test of coaxial and twinax SFP+ (1 m) cables. The load was measured when the cable was bent 1. A cable with a lower value of load is more flexible. The coaxial wire multicore construction provides much higher flexibility than the twinax construction. The load is more than times lower for the former than for the latter. The level of flexibility directly affects the reliability of the cable. Table 3 shows the insertion loss measured by bending the coaxial and twinax SFP+ (1 m) cables a specified number of times under the same conditions. While the twinax wire broke before being bent 1, times, the coaxial wire did not break until it had been bent 1, times and it maintained its signal transmission characteristics. As shown in Photo 1, the coaxial SFP+ (1 m) cable was folded at several points at a radius equal to its diameter, and the insertion loss was measured in the folded state. Figure 4 shows the measured insertion loss. A conventional twinax wire degrades or breaks due to the contact that occurs when the cable is placed or inserted and removed or when the server rack is 22 Direct Attach Cable with Micro Coaxial Wire for Data Center

opened and closed. When the coaxial wire multi-core cable was folded at a radius equal to its diameter, the signal transmission characteristics were not affected, indicating that the risk of degradation is very low. Table 2. Flexibility test results (bending load) Sample Twinax wire Unit No.1..38 No.2.49.362 No.3..42 Table 3. Bending durability test Number of bending cycles Insertion lossat. GHz [db/m] Twinax wire 4.7 4.7 1, 4.6 No electrical conduction, 4.7-1,.2-1, 6.1-16, No electrical conduction - N m 4. Evaluation Results of the SFP+ and QSFP+ Cables 4-1 Evaluation results of the SFP+ cable SFP+ is a form factor specified by a multi-source agreement (MSA), an industry standard for communication modules. The electrical interface specifications, including transmission characteristics, are defined in SFF-8431 (1). SFP+ (a passive cable) is specified as 1GSFP+Cu in SFF-8431 (1). Table 4 shows the main parameters related to the transmission characteristics. Figures to 8 show the evaluation results (3 m) of each parameter. Vcm is the common mode voltage* 3 output after cable transmission and a parameter most susceptible to the skew of the cable. The obtained value of Vcm proves that the developed low skew micro-coaxial wire has sufficient performance conforming to the specification. dwdp and VMA Loss are the parameters indi- Table 4. Main parameters of 1GSFP+Cu Parameter Minimum Maximum Unit Output AC Common Mode Voltage (Vcm) 13. mv (RMS) Difference Waveform Distortion Penalty (dwdp) 6.7 dbe VMA Loss 4.4 dbe VMA Loss to Crosstalk Ratio (VCR) 32. db 2 2 1 1 (13. mv) Photo 1. Cable folding test 1 2 3 4 6 7 8 9 1 11 12 13 14 1 Vcm [mv] Fig.. Output AC Common Mode Voltage (Vcm) w/o folding (solid line) 2 Insertion loss [db/m] 1 1 2 2 w/ folding (dashed line) 2 1 1 (6.7 dbe) 3 1 1 2 1 2 3 4 6 7 dwdp [dbe] Fig. 4. Effect of folding on insertion loss Fig. 6. Difference Waveform Distortion Penalty (dwdp) SEI TECHNICAL REVIEW NUMBER 8 APRIL 21 23

2 2 1 1 (4.4 dbe) Table. Main parameters of 4GBASE-CR4 Parameter Minimum Maximum Unit Insertion Loss at.162 GHz (IL) 3 17.4 db Integrated Crosstalk Noise (ICN) See Fig.1 mv (RMS) (min.) 1 2 3 4 6 1 m 2 VMA Loss [dbe] Fig. 7. VMA Loss Insertion loss (IL) [db] 1 1 2 3 m (max.) 2 1 1 (32. db) 2 1 2 3 4 6 7 8 Fig. 9. Insertion Loss (IL) 3 32 34 36 38 4 42 44 VCR [db] Fig. 8. VMA Loss to Crosstalk Ratio (VCR) 12 1 8 (max.) cating the level of degradation of a signal waveform after cable transmission. VCR is the tolerance to crosstalk* 4 between opposing lanes. It has been confirmed that these parameters are satisfactory. These results are for 3-m cables, for which the property requirements of the specifications are more severe. Satisfactory results were obtained similarly for 1-m cables. 4-2 Evaluation results of the QSFP+ cable As with SFP+, QSFP+ is a form factor specified by MSA, but its electrical interface specifications are not defined in MSA. Communication standards, such as Ethernet* and InfiniBand* 6, are referenced for QSFP+. This report presents the results of evaluation against 4GBASE-CR4 (2), an Ethernet standard for passive cables for a transmission rate of 4 Gb/s (4 1 Gb/s). Table shows the typical transmission performance parameters of 4GBASE-CR4. Figures 9 and 1 show the typical evaluation results. IL is a parameter indicating signal attenuation, which increases with an increase in the skew of the cable. It has been confirmed that with small variations among lanes, the obtained value of IL is sufficient to the specification. ICN is a parameter indicating the tolerance to crosstalk from the other seven lanes (3 lanes in ICN [mv] 6 4 2 1 m 2 4 6 8 1 12 14 16 18 2 Insertion loss at.162 GHz [db] the same direction and 4 lanes in the opposite direction). The coaxial wires in the cable must have a high shield performance to meet this property. It has been confirmed that with both high flexibility and shield performance, the developed coaxial wire has satisfactory properties for both 1-m and 3-m cables. 7. Conclusion We have reduced the skew of a micro-coaxial wire and have successfully developed thin, flexible and robust direct attach cables (SFP+, QSFP+) for use in 3 m Fig. 1. Integrated Crosstalk Noise (ICN) 24 Direct Attach Cable with Micro Coaxial Wire for Data Center

data centers, which have transmission characteristics as good as conventional twinax direct attach cables. We believe that these products will make a significant contribution to improving the ease of installation and operation and in heat dissipation performance for highdensity, high-speed signal wiring in the rack. Contributors (The lead author is indicated by an asterisk (*).) Y. MAEDA* Assistant General Manager, Sumitomo Electric Wire Inc. Technical Terms *1 Twinax wire: A twinax wire is made of two insulated signal wires and a drain wire placed in parallel and wrapped with conductive tape. *2 : A coaxial wire is made of a single insulated signal wire surrounded by a braided external conductor. Two coaxial wires are required for differential signal transmission. *3 Common mode voltage: The common mode voltage is a voltage in the same phase generated between two signal wires. It is generated due to an amplitude difference or a phase difference (skew) between negative and positive signals. *4 Crosstalk: Crosstalk refers to the leakage of a transmission signal from one transmission channel to another. In this report, it refers to the leakage of a signal from one lane to a specific lane in a direct attach cable. * Ethernet: Ethernet is a communication network standard. It is widely used as a practical Local Area Network (LAN) standard. *6 InfiniBand: InfiniBand is a high-speed interface standard developed by the InfiniBand Trade Association (IBTA) for servers or external storage devices. K. SHIMADA Optical Communications R&D Laboratories Y. ISOYA Sumitomo Electric Wire Inc. T. HAYASHISHITA Sumitomo Electric Wire Inc. M. HARUMOTO Group Manager, Optical Communications R&D Laboratories References (1) SFF-8431 Specification for Enhanced Small Form Factor Pluggable Module SFP+ Rev 4.1 (July 6, 29) (2) IEEE 82.3ba -21 Media Access Control Parameters, Physical Layers, and Management Parameters for 4 Gb/s and 1 Gb/s Operation SEI TECHNICAL REVIEW NUMBER 8 APRIL 21 2