FIELDPOINT BUS EXTENDER CABLE



Similar documents
Set Up Your MXI -Express x1 System

NI PXI Installing Your PXI Board INSTALLATION GUIDE

Set Up Your MXI -Express x4 System

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Installation. Basic Rack Power Distribution Unit for Blade Servers

PITCHED ROOF STRUCTURES

Required Supplies for Installing Check Tag Assembly

CompactRIO crio-9052

Replacing a Vantage Vue Transmitter

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

NI USB-6008/6009 OEM USER GUIDE

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

SAN25 ( <00>)

AU-110 racking guide NBXPN: 023

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

AMF112 ( <00>) 13mm (1/2 in.)

Complete System Shelter

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

AMF112 Instruction Manual

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

HP 16/18-Port Cable Management Kit Installation Guide

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Wall-Mounting your HP computer. User Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

RAIN COLLECTOR S HELF MANUAL

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

Rack Installation Instructions

Coupling Microsoft Excel with NI Requirements Gateway

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

INSTRUCTIONS: LocknCharge Laptop Carts

Mazda CX up B

NI-XNET Hardware and Software

Installation Instructions

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Home Signal Distribution Kit for Satellite TV Plus SIRIUS

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

Installing Your 960 or 980 Server into a Rackmount Cabinet

Part Name/Description Part Number Quantity. Power Cable

XL PREMIUM OIL COOLER KIT

CoolWave r 2 Phase Control Board and Cable Replacement Kits

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

KNX Interface. User Manual PM00A00IRI

Vantage Pro2 Temperature/Humidity Sensor Replacement Kit

Small form factor bay converter and hard drive installation

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Directory chapter 04

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

50 TO 60 INSTALLATION INSTRUCTIONS v1.0

Unpack and Install the Devices, Accessories, and Cables

A701 ( <01>)

Hollow or Cinder Block Wall Mount Job Aid

Cabinets 101: Configuring A Network Or Server Cabinet

NI 653x Cable Adapter

PCI/PXI ETHERNET ADAPTERS

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

SECURITY SYSTEM SMART SIREN KIT

LABVIEW DSP TEST TOOLKIT FOR TI DSP

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Allen-Bradley HP AC Line Filter Kit

Home Signal Distribution Kit for Cable TV Plus SIRIUS

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

INSTALLATION MANUAL MODEL RP-100

LabVIEW DSP Test Integration Toolkit for TI DSP

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

PCS300 Universal IP Reporting Module V1.0

Using NI CompactDAQ Controllers

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

The power module is Feature Number 8800-F2-901.

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

MCR1900 Media Converter 19-Slot Chassis

Mazda CX up B

BRACKET LOCKING SCREW

INSTALLATION INSTRUCTIONS MULTI-MOUNT KIT Part Number: Application: Warn HP PowerPlant P/N 71800

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

Rack installation instructions

CENTERLINE Motor Control Centers Splicing Horizontal Ground Buses

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

LabVIEW Report Generation Toolkit for Microsoft Office

HP UPS R1500 Generation 3

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

R O A D M A S T E R, I N C.

GPS AutoSteer System Installation Manual

V Installation instructions, accessories. Digital radio DAB. Volvo Car Corporation Gothenburg, Sweden. V70 (08-) 2011 Volvo Cars Europe

EZ-Steer Assisted Steering System

INSTALLATION INSTRUCTIONS

DC Series Digital Conversion Alarm Operator s Manual

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Quick Start Guide. RV0xx Series Routers

AZEK Rail Install Guide

Transcription:

INSTALLATION GUIDE FIELDPOINT BUS EXTENDER CABLE If you have space constraints, you can use the FieldPoint Bus Extender Cable to mount a FieldPoint bank in two or three rows. Caution You should not use more than two FieldPoint Bus Extender Cables per FieldPoint bank. Caution Disconnect power from the network module and terminal bases before you install the Bus Extender Cable. Do not disconnect a Bus Extender Cable while the FieldPoint bank is powered on. Choosing a Configuration Before you begin installing the Bus Extender Cable, choose a configuration for the FieldPoint bank. With the Bus Extender Cable, you can mount rows of modules with terminal blocks together (bottom-to-bottom) or with terminal blocks apart (top-to-top). Mounting modules with terminal blocks together lets you use one wiring conduit for two rows of modules and is the recommended method due to cooling considerations. You should install higher-powered I/O modules on top in this configuration to further help with cooling. Figure 1 shows configuration examples with two rows. You can use up to three rows. Blocks Together Blocks Apart (Recommended due to better cooling) network module I/O modules more I/O modules more I/O modules network module I/O modules Figure 1. FieldPoint Bank Configuration Options FieldPoint, National Instruments, NI, and ni.com are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 322174C-01 1998 2002 National Instruments Corp. All rights reserved. February 2002

Figure 2 shows the dimensions for mounting the terminal bases with the terminal blocks together. Dimensions are given in inches [millimeters]. 1.76 [44.6] 1.05 [26.7] female end 1.11 [28.2] and network module 6.70 [170] 0.59 [14.9] Cable Mounting Holes 14.0 [355] male end Figure 2. Mounting with Blocks Together FieldPoint Bus Extender Cable 2 ni.com

Figure 3 shows the dimensions for mounting the terminal bases with the terminal blocks apart. Dimensions are given in inches [millimeters]. 1.76 [44.6] 1.05 [26.7] male end 2.00 [50.8] 0.59 [14.9] 1.11 [28.2] Cable Mounting Holes and network module female end 9.30 [236] Figure 3. Mounting with Blocks Apart Installing the Bus Extender Cable You can install the FieldPoint bank on a DIN rail or on a panel. Installing the bank on a wall or a panel is the more secure installation option and may prevent accidental disconnection. Installing the Bus Extender Cable on a DIN Rail Follow these steps to install the Bus Extender Cable on a DIN rail: 1. Install the FieldPoint bank on the DIN rail. Refer to the Quick Start Guide for the network module you are using. 2. Make sure power is disconnected from the FieldPoint bank. National Instruments Corporation 3 FieldPoint Bus Extender Cable

3. Plug in the Bus Extender Cable. The female end of the cable plugs into the terminal base closer to the network module. The male end of the cable plugs into the terminal base farther from the network module. The cables are keyed to prevent improper installation. If you have the optional DIN rail mounting kit, part number 777609-02, follow steps 4 5. If you do not have the optional DIN rail mounting kit, go to step 6. 4. Place the mounting bracket on the DIN rail and slide it under the mounting tab of the Bus Extender Cable. 5. Drive the long screw that came with the DIN rail mounting kit through the mounting tab of the Bus Extender Cable and the mounting bracket. Drive the short screw that came with the DIN rail mounting kit through the other end of the mounting bracket, and use the split lock washer. The imum tightening torque for each screw is 0.95 N-m or 8.4 lb-in. The Bus Extender Cable installed with the mounting bracket should appear as shown in Figure 4. 1 2 3 1 Long screw 2 Mounting bracket 3 Short screw with split lock washer Figure 4. Installing the Bus Extender Cable on a DIN Rail with a Mounting Bracket FieldPoint Bus Extender Cable 4 ni.com

6. If you are not using a mounting bracket, and you intend to mount the DIN rail to a panel, use the long metal spacer that came with the Bus Extender Cable. Drill pilot holes for the cable mounting hole according to the dimensions in Figure 2 or 3. Then place the long spacer under the mounting tab of the Bus Extender Cable and drive a screw through them as shown in Figure 5. 1 1 Long spacer Figure 5. Installing the Bus Extender Cable on a DIN Rail with a Metal Spacer Installing the Bus Extender Cable on a Panel Follow these steps to install the Bus Extender Cable on a panel: 1. Drill pilot holes into the panel according to the dimensions in Figure 2 or 3. 2. Install the FieldPoint bank on the panel. Refer to the Quick Start Guide for the network module you are using. 3. Make sure power is disconnected from the FieldPoint bank. 4. Plug in the Bus Extender Cable. The female end of the cable plugs into the terminal base closer to the network module. The male end of the cable plugs into the terminal base farther from the network module. The cables are keyed to prevent improper installation. National Instruments Corporation 5 FieldPoint Bus Extender Cable

5. Place the short spacer under the mounting tab of the Bus Extender Cable and drive a screw through them into the pilot holes you drilled on the panel. The Bus Extender Cable installed on a panel should appear as shown in Figure 6. 1 1 Short spacer Figure 6. Installing the Bus Extender Cable on a Panel Powering Up the FieldPoint Bank You can now connect power to the FieldPoint bank. Remember to disconnect power first, if you need to remove the Bus Extender Cable at a later time. FieldPoint Bus Extender Cable 6 ni.com