Nano Meter Stepping Drive of Surface Acoustic Wave Motor



Similar documents
ENS 07 Paris, France, 3-4 December 2007

DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD

Alternative Linear Motion Systems. Iron Core Linear Motors

INTERFERENCE OF SOUND WAVES

A METHOD OF PRECISE CALIBRATION FOR PIEZOELECTRICAL ACTUATORS

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

E190Q Lecture 5 Autonomous Robot Navigation

Lamb wave mode conversion in CFRP plates

Lab 9: The Acousto-Optic Effect

Laser-induced surface phonons and their excitation of nanostructures

LOCATION DEPENDENCY OF POSITIONING ERROR IN A 3-AXES CNC MILLING MACHINE

Fabrication of Complex Circuit Using Electrochemical Micromachining on Printed Circuit Board (PCB)

Describing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power

Safakcan Tuncdemir 1, William M. Bradley *2. 1. Introduction

Linear Parameter Measurement (LPM)

Acousto-optic modulator

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

Proposal for a Slot Pair Array Having an Invariant Main Beam Direction with a Cosecant Radiation Pattern Using a Post-Wall Waveguide

The Acoustical design of Mobile phones

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

AIR RESONANCE IN A PLASTIC BOTTLE Darrell Megli, Emeritus Professor of Physics, University of Evansville, Evansville, IN dm37@evansville.

Fast Varifocal Lenses Based on KTa 1-x Nb x O 3 (KTN) Single Crystals

SCS Directory Accreditation number: SCS 0115

An Electromagnetic Micro Power Generator Based on Mechanical Frequency Up-Conversion

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range

Keysight Technologies How to Choose your MAC Lever. Technical Overview

2.5-inch Hard Disk Drive with High Recording Density and High Shock Resistance

Active noise control in practice: transformer station

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

COMPETENCY GOAL 1: The learner will develop abilities necessary to do and understand scientific inquiry.

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves

Dynamic wave dispersion and loss properties of conventional and negative Poisson's ratio polymeric cellular materials 1 INTRODUCTION

Introduction to acoustic imaging

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

A New SAW Device Simulator Based on Mason s Equivalent Circuit Model

Encoders for Linear Motors in the Electronics Industry

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :

MICRO DROPLET GENERATION TECHNOLOGY

BIOMEDICAL ULTRASOUND

Surface Profilometry as a tool to Measure Thin Film Stress, A Practical Approach. Gianni Franceschinis, RIT MicroE Graduate Student

FXA UNIT G485 Module Ultrasound. Candidates should be able to :

Current Probes, More Useful Than You Think

INTERACTION BETWEEN MOVING VEHICLES AND RAILWAY TRACK AT HIGH SPEED

EDUMECH Mechatronic Instructional Systems. Ball on Beam System

Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves

Synthetic Sensing: Proximity / Distance Sensors

Finite Element Modeling of 2-D Transducer Arrays

A Guide to Acousto-Optic Modulators

Scientific Exchange Program

SAW and MWC filters key components for mobile terminals and base-stations

Dynamic Force Calibration Methods for Force Transducers. Yusaku FUJII Gunma University

Experiment 5. Lasers and laser mode structure

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

arxiv:astro-ph/ v1 15 Sep 2005

Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging.

Sample Questions for the AP Physics 1 Exam

Digital demodulator unit of laser vibrometer standard for in situ measurement

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE

Piezoelectric Driven Non-toxic Injector for Automated Cell Manipulation

Acceleration levels of dropped objects

Free piston Stirling engine for rural development

Spectrum Level and Band Level

METHOD STATEMENT HIGH STRIAN DYNAMIC TESTING OF PILE. Prepared by

A Practical Guide to Free Energy Devices

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

1) The time for one cycle of a periodic process is called the A) wavelength. B) period. C) frequency. D) amplitude.

Profile rail guides LLR

A Planar Capacitive Micro Positioning Sensor

Vibrometry. Laser Vibrometers Optical Measurement Solutions for Vibration Product Brochure

1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids

Active and passive structural health monitoring system based on arrays of ultrasonic guided waves transducers

Moving Magnet Actuator MI FFA series

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Using light scattering method to find The surface tension of water

Andrea Bulletti and Lorenzo Capineri. 1. Introduction

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Non-Contact Vibration Measurement of Micro-Structures

The Design and Characteristic Study of a 3-dimensional Piezoelectric Nano-positioner

4.4 WAVE CHARACTERISTICS 4.5 WAVE PROPERTIES HW/Study Packet

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Proof of the conservation of momentum and kinetic energy

Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections

Dynamics-based Structural Health Monitoring Using Laser Vibrometry

Address for Correspondence

A Surveillance Robot with Climbing Capabilities for Home Security

Physics 6C, Summer 2006 Homework 2 Solutions

The University of the State of New York REGENTS HIGH SCHOOL EXAMINATION PHYSICAL SETTING PHYSICS. Wednesday, June 17, :15 to 4:15 p.m.

The Sonometer The Resonant String and Timbre Change after plucking

Turbine Design for Thermoacoustic

Motors and Generators

Transcription:

Proc. of 1st IEEE Conf. on Nanotechnology, Oct. 28-3, pp. 495-5, (21) Maui, Hawaii Nano Meter Stepping Drive of Surface Acoustic Wave Motor Takashi Shigematsu*, Minoru Kuribayashi Kurosawa*, and Katsuhiko Asai** *Tokyo Institute of Technology, Department of Advanced Applied Electronics, G2-66, 4259 Nagatsuta, Midori-ku, Yokohama, 226-852, Japan tucker@ae.titech.ac.jp, mkur@ae.titech.ac.jp **Matsushita Electric Industrial Co., Ltd., Advanced Technology Research Laboratories, 3-4 Hikaridai, Seika, Souraku, Kyoto 619-237, Japan kasai@crl.mei.co.jp Abstract A high resolution, from nanometer to sub-nanometer, stepping drive of a surface acoustic wave (SAW) motor is presented in this paper. A step displacement was controlled easily by a number of driving waves from centimeter order to nanometer order. Reduction of the driving waves down to 25 cycles, at 1 Vpeak driving voltage and 3 N pre-load condition, brought about 2 nm stepping drive with our experimental setup at open loop condition. We also demonstrated a sub-nanometer stepping drive. These experimental results indicate that the surface acoustic wave motor has an ability of subnanometer positioning with centimeter stroke. 1. Introduction An ultrasonic motor is a motor which uses ultrasonic vibration a type of elastic vibration- to obtain a driving force, which then drives the motor using friction [1]. Surface acoustic wave motor is a kind of ultrasonic motor that uses 9.6 MHz Rayleigh wave, a kind of surface acoustic wave, for friction drive. Conventional ultrasonic motors, which use micrometer order vibration for friction drive, have sub-micrometer positioning [1]. Surface acoustic wave motor uses nanometer order vibration for friction drive. On the analogy of conventional ultrasonic motors, we have suggested surface acoustic wave motor s possibility of RF Power Rayleigh Wave Pre-Load Slider Electrode (IDT) SAW Device (Stator Transducer) Fig.1 Schematic view of a surface acoustic wave motor. nanometer order stepping drive [2][3]. Due to the technical limit of measuring equipments, we have only reported 4 nm [4] and 25 nm [5] stepping drives. This paper describes the stepping drives of surface acoustic wave motor, down to sub-nanometer order, measured with a laser Doppler vibrometer that has 2 pm resolution. 2. Principle A schematic view of a surface acoustic wave motor is illustrated in Fig.1. A surface acoustic wave device (stator transducer) is made of 127.8 q y-rotated x- propagating LiNbO 3 substrate. RF electrical power (9.6 MHz) is transduced to Rayleigh wave at the interdigital transducer (IDT) with piezoelectric effect. Surface particles of propagating Rayleigh wave move in elliptical motion, as illustrated in Fig.2. This kind of particles elliptical motion is utilized for conventional traveling wave type ultrasonic motors. However, the vibration amplitude of a surface acoustic wave device is extremely smaller, about 2 nm with 1 Vpeak driving voltage, due to the high driving frequency. The elliptical motion of surface particles yields friction driving force with a slider surface. A slider is made of silicon substrate being processed with Amplitude 2nm Pre-Load Friction Slider Elliptical Motion of Particles Rayleigh Wave Stator Transducer Wavelength 4 µo Fig.2 Principle of a surface acoustic wave motor.

surface micro fabrication technology to obtain output mechanical power efficiently [6][7]. Pre-load of the slider that means pushing the slider against the stator transducer enlarges friction force between the stator transducer and the slider. The large frictional force brings about large output force of the motor. 3. Experimental Setup An experimental setup is shown in Fig.3. The setup is consists of a fixed part and a movable part. A 6x15x1 mm 3 stator transducer and a linear guide rail are the fixed part, and they are fixed in parallel. At each end of the stator transducer, inter digital transducers (IDTs) are deposited. The dimensions of the IDT are 4 µm in pitch, 1 µm in electrode strip width and 9 mm in aperture size, as illustrated in Fig.4. The IDT is composed of 2 strip electrode pairs and the resonance frequency for Rayleigh wave propagation is 9.6 MHz. A movable part comprises a 4x4x.3 mm 3 silicon slider, a steel hemisphere and a linear guide stage. The movable part moves along the linear guide rail. The silicon slider is glued on the steel hemisphere. The steel hemisphere is connected with the linear guide stage so that the silicon slider contacts a stator transducer surface properly. The movable part is schematically illustrated in Fig.5. A laser beam of the laser Doppler vibrometer was incident on the steel hemisphere to measure the step motion of the silicon slider. The pre-load is given by a coil spring so that the pre-load adjusted easily. Burst driving voltages were applied to the IDT every.2 ms to drive the surface acoustic motor in stepping motion. The waveform of the applied burst driving voltage is schematically shown in Fig.6. An example of stepping drive motion is shown in Fig.7, where the driving voltage was 1 Vpeak, the driving waves were 5 cycles, and the pre-load was 3 N. Step motions were observed every.2 ms when the driving voltages were applied. Each step displacement was about 2 nm. 15 mm 1 mm 3 mm 1 mm 6 mm 9mm.4mm.1mm 2Pairs Fig.4 Geometry of the stator transducer and IDTs. Steel Hemisphere Linear Guide Stage Washer Silicon Slider Fig.5 Schema of the driving part of the setup. Electrode (IDT) SAW Device (Stator Transducer) Silicon Slider Hemisphere Time Drive Direction Pre-Load Linear Guide Stage N Cycles Burst Period Fig.6 Waveform of the driving voltage. Fig.3 Photograph of the experimental setup.

4. Characteristics of Stepping Drive Figure 8 shows stepping drive motion in detail. This motion is the same motion of Fig.7, but it is enlarged to examine the detailed step motion. Two parts composed a single step, where the driving voltage was applied; the Rayleigh wave was excited, and vice versa. When the Raylegih wave is excited, friction with surface particles of the stator transducer yields the driving force to the silicon slider. The friction driven displacement is defined in Fig.8, as the displacement during the driving voltage is applied. It is the first part of the step motion and is the actual driven displacement due to the friction between the stator transducer and the silicon slider. The second part is where the driving voltage is not applied; the Rayleigh wave has passed away. There is no driving force to the silicon slider at this part, but extra displacement seems to be yielded in Fig.8. It was caused by the inertia of the linear guide stage. The mass of the linear guide stage was 9.42 g, and the one of the silicon slider with glued hemisphere was.89 g. The mass of the linear guide stage was much larger and the friction with the linear guide rail was existed. Then the response of the linear guide stage was slower. Hence, the silicon slider (and the glued hemisphere) was dragged when the Rayleigh wave had passed away. It indicated that the movable part of the experimental setup did not move as a single mass. Namely, the movable part behaved as the two connected masses. One was the lighter slider part that consisted of the silicon slider and the steel hemisphere, and the other was the heavier linear guide stage part. 2 15 1 5 2 µs 5.2 µs 2 nm.5 1 1.5 2 Fig.7 The stepping drive motion; the driving voltage was 1 Vpeak, and the driving waves were 5 cycles, and the pre-load was 3 N. The burst period was.2 ms. After the friction drive, vibration occurred as shown in Fig.8. This vibration happened at the connection of the movable part s two masses. The washer and the steel hemisphere were used for the connection of these two parts to make contact the silicon slider against the stator transducer properly. The friction drive of the silicon slider makes elastic deformation at this connected region during the first part of the step motion. The elastic deformation causes the followed vibration of the second part of the step motion. Friction Driven Diplacement [nm] 5 4 3 2 1.1.2.3.4.5 Fig.8 Detail of the stepping drive; the driving voltage was 1 Vpeak, the driving waves were 5 cycles, and the pre-load was the 3 N. The burst period was.2 ms. It is the same condition of the Fig.7. 7 6 5 4 3 2 1 2 µs 5.2 µs Friction Driven Displacement Step Displacement 2 4 6 8 1 12 Number of Waves Fig.9 Friction driven displacement against the number of driving waves; the driving voltage was 1 Vpeak, and the pre-load was 3 N.

Friction Driven The friction driven displacements of stepping drives were measured for estimation of the friction drive, instead of the step displacement. The driving waves were varied from 2 cycles to 1 cycles, while the driving voltage was 1 Vpeak, and the pre-load was 3 N. The friction driven displacement against the number of the driving waves is shown in Fig.9. The friction driven displacement increased with the square of the number of the driving waves. The friction driven displacement of.5 nm was obtained at the 2 cycle driving waves. Friction Driven 2 15 1 5 4 Cycles 6 Cycles 8 Cycles 8 9 1 11 12 13 [Vpeak] Fig.1 Friction driven displacement against the driving voltage; the driving waves were 4, 6, and 8 cycles, and the pre-load was 3 N. 1 8 6 4 2 4 Cycles 6 Cycles 8 Cycles 1 2 3 4 5 Pre-Load [N] Fig.11 Friction driven displacement against the pre-load; the driving voltage was 1 Vpeak, and the driving waves were 4, 6, and 8 cycles. The driving voltage was varied from 9 Vpeak to 12 Vpeak, while the driving waves were 4, 6 and 8 cycles, and the pre-load was 3 N. The friction driven displacement against the driving voltage is shown in Fig.1. The friction driven displacement increased with the square of the driving voltage at each driving waves. The pre-load was varied from 2 N to 4 N, while the driving voltage was 1 Vpeak, and the driving waves were 4, 6 and 8 cycles. The friction driven displacement against the pre-load is shown in Fig.11. The friction driven displacement decreased in inverse proportion to the pre-load. 5. Nano Meter Stepping Drive Changing of the number of the driving waves is the easiest way to obtain desired stepping drive at open loop condition. The friction driven displacement increased with the square of the number of the driving waves as previously shown in Fig.9. Then, the nanometer order stepping drives were examined with reduction of the driving waves, while the driving voltage and the pre-load were maintained at 1 Vpeak and 3 N. With the 4 cycles of the driving waves brought about 8 nm stepping drive as illustrated in Fig.12. It was the finest stepping drive we obtained without signal processing of the measured motion into the less noise data signal. The drift of the laser Doppler vibrometer deserved about 5 to 1 nm, then it was uncertain to obtain the stepping drive motion under 5 nm with single shot of measurement. 8 7 6 5 4 3 2 1 2 µs 4.2 µs 8 nm.5 1 1.5 2 Fig.12 The 8 nm stepping drive; the driving voltage was 1 Vpeak, the driving waves were 4 cycles, and the pre-load was 3 N. The burst period was.2 ms.

Figure 13 shows the stepping drive motion with 25 driving waves, as the driving voltage was 1 Vpeak and the pre-load was 3 N. It is the averaged motion of 28 times stepping drives. The step displacement was about 2 nm, and the friction driven displacement was about 1 nm. It was the finest stepping drive of the experimental setup. It seems that the inertia and the vibrations due to the elastic deformation were significant in these nanometer range of stepping drives. The beginning several cycles of the vibration followed after the friction drive had almost same amplitude of the friction driven displacement that was about 1nm. The vibration becomes a problem at the sub-nanometer range stepping drive as shown in Fig.14. This graph shows the stepping drive motion with 2 driving waves, while the driving voltage was 1 Vpeak, and the preload was 3 N. It is also the averaged motion of 3 times stepping drives. Mean traveling motion of.5 nm in each step with sub-nanometer vibration was observed. The friction driven displacement and the vibration amplitude caused by the elastic deformations were similar quantity at all the time of the stepping motion. This motion is no more called stepping drive, but.5 nm friction driven displacement was verified. Namely, the sub-nanometer step motion was masked with the vibration due to the compliance of the structure. 25 2 15 1 5 2 µs 2.6 µs 2 nm.5 1 1.5 2 Fig.13 The finest stepping drive, 2 nm step, motion of the experimental setup; the driving voltage was 1 Vpeak, the pre-load was 3 N, and the driving waves were 25 cycles. The burst period was.2 ms. It was the averaged motion of 28 times. 6. Vibration of The Movable Part The simplified mechanical model of the movable part is proposed in Fig.15 considering the compliance of the structure. The elastic connection between the steel hemisphere and the washer was indicated by the spring. When the Rayleigh wave is excited, the driving force is given to the silicon slider. The silicon slider is driven to the direction to compress the spring. The compressed spring thrusts the linear guide stage in the meanwhile. After the Rayleigh wave passed away, there is no driving force to the silicon slider and then the silicon slider is thrust back by the elastic force of the compressed spring. In this way, the slider part, namely the silicon slider and the glued hemisphere, starts vibration according to the mass of the slider part and the elastic constant of the spring. 5 4 3 2 1.5 nm 2 µs 2.1 µs.5 1 1.5 2 Fig.14 The stepping drive motion of 1nm; the driving voltage was 1 Vpeak, the pre-load was 3 N, and the driving waves were 2 cycles. This friction driven displacement was about.5 nm. The burst period was.2 ms. It was the averaged motion of 3 times. Linear Guide Rail Elastic Force Force Elastic Force Slider Resistance against Linear Guide Stage Stator Transducer Fig.15 The simplified mechanical model of the movable part.

On the other hand, the linear guide stage thrusts by the inertia that is given by the first movement of the driven slider part. As previously indicated, the mass of the linear guide stage was 9.42 g and the mass of the slider part, the slider and the glued hemisphere, was.89 g. The mass of the linear guide part was about 1 times larger than the slider part. Hence, the linear guide stage does not vibrate as the slider part does. The linear guide stage responds slower to the elastic force of the compressed spring. 7. Conclusion The nanometer stepping drives of the surface acoustic wave motor were examined. The finest stepping drive of the experimental setup was the 2 nm step motion. Although, the sub-nanometer step motion masked with the vibration is indicated. Then reduction of the vibration due to the compliance of the structure is required. The rigid structure will perform a fine subnanometer stepping motion. 8. Acknowledgement This work was supported by the Grant-in-Aid for the Development of Innovative Technology of the Ministry of Education, Culture, Sports, Science and Technology of Japan. 9. References [1] S. Ueha and Y. Tomikawa, Ultrasonic motors- Theory and Applications, Oxford, Clarendon Press, 1993. [2] M. Kurosawa, M. Takahashi and T. Higuchi, Ultrasonic Linear Motor Using Surface Acoustic Waves, IEEE Trans. Ultrason., Ferroelect., Freq. Cont., vol.43, no.5, pp.91-96, 1996. [3] N. Osakabe, M. Chiba, M. K. Kurosawa and T. Higuchi, Experimental Estimation of Surface Acoustic Wave Linear Motor, Proc. of Int. Conf. on Micromechatronics for Info. and Precis. Equip. Tokyo, pp.265-268, 1997. [4] M. K. Kurosawa and T. Higuchi, Surface Acoustic Wave Motor, Proc. of 3rd Int. Heintz Nixdorf Symp., Paderborn, Germany, pp.113-118, 1999. [5] M. K. Kurosawa, State-of-the-art surface acoustic wave linear motor and its future applications, Ultrasonics 38, pp.15-19, 2. [6] M. Takasaki, M. K. Kurosawa and T. Higuchi, Optimum contact conditions for miniaturized Surface acoustic wave linear motor, Ultrasonics 38, pp.51-53, 2. [7] M. K. Kurosawa, H. Itoh, K. Asai, M. Takasaki and T. Higuchi, Optimization of Slider Contact Face Geometry for Surface Acoustic Wave Motor, Proc. of Micro Electro Mechanical Systems, Interlaken, Suisse, pp.252-255, 21.