MAXSYS. High-End Integrated Security from DSC



Similar documents
MAXSYS. High-End Integrated Security from DSC

Seamless Security Solutions NORTH AMERICAN EDITION

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

SECTION DETECTION AND ALARM

Always on the Lookout Perfect Protection against Burglary

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Security Alarm - Fire Alarm system Central Monitoring Services Promotion Packages

FIRE DETECTION Note: Your installer must enable the fire detection portion of this equipment before it becomes functional.

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

LYNX. The Best in Wireless Home Security...

Simon XTi Installation Guide

Solution Ultima ICP-CC488 Home security you can rely on

From Tyco Security Products PRODUCT CATALOG EUROPE, MIDDLE EAST & AFRICA

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Expansion Modules & Accessories

Solution Ultima ICP-CC488 Home security you can rely on

PC4020 v3.0 Installation Manual DLS-2 v1.3

Teldat Security IP & Wireless GSM/GPRS Alarm Communicators

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

A VOLUTION. S series. Avolution S Series Security System. ASSA ABLOY, the global leader in door opening solutions

System Introduction S E C T I O N 1

From Tyco Security Products PRODUCT CATALOG

GSM ALARM SYSTEM USER MANUAL

wireless alarm system reliable protection for small-size buildings

Security with you in mind. As your needs change, NetworX security systems grow with you.

Solution 144 The Integrated Access Control & Alarm System made for your business

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Alliance System Ordering Guide

Security with you in mind. As your needs change, NetworX security systems grow with you.

PowerCode Wireless. Fully supervised wireless system. Features

GE Concord 4 Quick User Guide

NetworX. Security with you in mind. As your needs change, NetworX security systems grow with you.

$329. Security Systems OPTIONS. (WGUARD) WatchGuard DIY KIT

868 Mhz. Wirefree DIY. Friendly. Easy Fit Range of Alarms

Security Systems Intrusion Alarm

PC1616 / PC1832 / PC1864

Omni 600 control panel with 8 zone LED keypad

Installation Manual. PC5O1O Version 2.O (UL) DLS-3 version 1.3 or later

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Ademco Vista-20P/First Alert FA-168C Basic Commands

VISTA Plus Series INFORMATION FOR SECURITY DEALERS. Build Your Business with VISTA... the Industry s Leading Residential Control

How To Control A Control Panel With A Pager And A Power Control Unit

Residential & Commercial Alarm Systems by Gross Security, LLC

Intrusion. IC60 security meets design. Answers for infrastructure.

INTERFACING SECURITY SYSTEMS TO HOMEVISION

Control/Communicator Installation Manual

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Your Canadian Security Specialists. Eddie D Orazio

728 SERIES REFERENCE & INSTALLATION MANUAL 728+ VERSION series

Spectra SP Expandable Security Systems

Application Notes Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.

VR8. User Guide Intruder Alarm System

System off. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

MORE THAN 100 NEW FEATU

Digiplex Control Panel (DGP-848) - V4.1

Reference & Installation Manual

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

ICP-CC488. Installation Guide ICP-CC488 Control Panel

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Using your LED Plus keypad

Commander 2000 Control Panel

PC1616/PC1832/PC1864 User Manual

HOW TO REDUCE OR PREVENT FALSE ALARMS

Hills wireless security alarm DIY range

All tested. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

ERS-2400B. PERS-2400B Personal Emergency Reporting System

Doc 10. UTM Standards: Card Access Security System

User's Manual. For use with ProSYS 16, ProSYS 40, and ProSYS 128

Fully Supervised Wireless Alarm Control Solution

NX-10-V3 wireless system. To wire or not to wire?

INSTALLATION MANUAL PC2525. Version 1.1

APR-PRT3 Printer Module: C-Bus Programming Instructions

NX-8V2 Control Panel Installation Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

S100. GSM House Alarm System.

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

High Security and Access System EVO48 V1.20 EVO192 V1.20

Solution 16 plus Security at your fingertips

NetworX Series. NX-216E Zone Expander Module Installation and Startup

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

Tattletale Portable Alarm System

United Security Products Automatic Dialers are a NEW BREED of Security

Internet/Intranet Alarm Communications. Maximize security and convenience with Internet/Intranet alarm communications

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Simon XT Installation Guide

PC1616 / PC1832 / PC1864

System off. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

January 1, RE: TG-7FS Sole Path Cellular Alarm Communicator. To whom it may concern:

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

NESS D Zone Control Panel and Dialler OWNER S MANUAL

Transcription:

High-End Integrated Security from DSC

COMPREHENSIVE SECURITY THAT S NOT COMPLICATED Managing a business takes a lot of work, passion and commitment. That s why it s important that the same effort be made when choosing a security system. After all, properly protecting the people and other valuable assets that comprise a successful business are not something you want to jeopardize. There was a time when building security consisted of little more than burglar alarms, motion detectors and a few smoke detectors. Clearly times have changed and the need for a premium security system is real. In keeping with new times and new technologies, DSC has defined the meaning of security, as is evident with MAXSYS. The security system allows a host of value-added and life-safety features to be integrated to provide peace of mind for years to come. Security concerns, whether they are intrusion, fire, alarm communications, access control, automation, wireless/addressable expansion or structured cabling, can be tailored to meet specific needs. MAXSYS is truly a single-system solution that is ideal for commercial, industrial and institutional facilities, as well as large or multi-level residential units. s s Fully integrated security solutions High-end, premium quality security

INTRUSION CONTROL PANELS Every business is unique. With MAXSYS you can choose the best combination of technologies to expand security needs as necessary. s s s COMBUS expansion Addressable loop expansion Wireless expansion KEYPADS The MAXSYS LCD keypad puts security and convenience at your fingertips. The keypad offers end-users simple one-button activation of five programmable function keys. For urgent situations, keypad-activated emergency keys send an alarm signal to the central monitoring station, which in turn, notifies the proper authority (police, fire or emergency services). 16-128 Zone Control Panel PC4020 16 zones on main control panel Supports up to 16 hardwired keypads Expandable to 128 zones using hardwire, wireless modules and addressable zones COMBUS hardwired expansion 8 partitions 1,500 user codes (4 or 6 digit) 3,000-event buffer 9 account and 3 phone numbers 1 supervised bell zone Built-in telephone line and siren supervision Auto SIA and Contact ID formats Supports GS3050-A/GS3050-I GSM universal wireless alarm communicators and T-Link /T-Link TL250 network/internet alarm communicators Full upload/download support with DLS download software Programmable-Message LCD Keypad LCD4501 Connect up to 16 keypads Large, backlit, 2-line, 32-character display Plain-language display of zone status, system status, trouble conditions, event buffer, system instructions, date and time Ready, Armed and Trouble LEDs 5 programmable function keys 4 keypad-activated alarms: - Panic, Auxiliary, Fire and Duress Backlight boost

GSM ALARM COMMUNICATIONS GSM universal wireless alarm communicators are an effective backup or alternative to traditional telephone lines and work by connecting the alarm control panel to the GSM network to provide protection against accidental line cuts. GSM Universal Wireless Alarm Communicators GS3050-A: Compatible with any control panel 4 inputs for the activation of voice messages and SMS dialer (optional NC2/VOX voice board module required for voice dialer) 2 SMS messages available on each input Programmable voice/sms dialer-channel activation 8 telephone numbers available for the voice/sms dialer function 5 outputs (open collector) Output control via SMS messaging Dual-band (900 MHz and 1,800 MHz GSM networks) SIM card (not included) programmable via any GSM cellphone or PC with the Windows compatible GS3050-A Software Application Compatible with standard central monitoring station receivers, like Sur-Gard 7-segment status display Supports Contact ID, 10 bps and 20 bps protocols, and in areas with optimum signal strength, SIA and CESA protocols GS3050-I: The GS3050-I includes all of the same features as the GS3050-A, with the following exceptions. Dual-band: - I version (850 MHz/1,900 MHz networks) - IW version (900 MHz/1,800 MHz networks) 4 outputs (open collector) Optional NC2/VOX voice board module is not available Not equipped with 7-segment status display Includes GS3050-I Software Application INTERNET & NETWORK ALARM COMMUNICATORS The award-winning DSC T-Link family of Internet and network alarm communicators saves customers money by taking advantage of their existing Internet/Intranet networks to create fully supervised security solutions between protected premises and the central monitoring station. Internet Alarm Communicator T-LINK TL250 T-Link TL250 Internet alarm communicators provide an always-on, two-way line of IP communication between DSC control panels and central monitoring station receivers. It works over the Internet or local LAN/WAN networks and installs easily, even behind firewalls. Network Alarm Communicator T-LINK Low-cost T-Link network alarm communicators transmit alarm signals securely over an existing LAN/WAN network and then through the Internet to a central monitoring station. This is an ideal application for banks or large retail chains where significant networks have already been established and are being used for various purposes. WIRELESS EXPANSION Use the PC4164-433 wireless receiver to support up to 64 wireless zones and 16 wireless keys. Up to eight backup receivers can be installed on one system. Choose wireless devices from the innovative line-up of DSC wireless solutions. Multiple receivers for larger coverage area or overlap New technology for greater signal range and accuracy Long-life lithium batteries Attractive, compact designs Easy to install, program and use

ADDRESSABLE LOOP EXPANSION The Addressable Multiplexed Loop (AML) provides the ultimate in simple, flexible and affordable zone expansion. Save time and money by connecting any addressable detector anywhere on the two-wire AML loop to create up to 128 addressable zones. Addressable Passive Infrared Detector AMB-300 Based on the Bravo 3 hardwire motion detector Patented MLSP (Multi-Level Signal Processing) Interchangeable lenses: -Wall-to-wall lens (standard), curtain lens, pet-immune lens and corridor lens Built-in tamper switch Addressable Pet-Immune Passive Infrared Detector AMB-600 Based on the Bravo 6 hardwire motion detector Patented MLSP (Multi-Level Signal Processing) Provides pet immunity up to 85 lbs (38 kg) Built-in tamper switch Addressable Ceiling-Mount Passive Infrared Detector AMB-500 Based on the Bravo 5 hardwire motion detector Patented MLSP (Multi-Level Signal Processing) Coverage diameter based on mounting height Built-in tamper switch Addressable Glassbreak Detector AMA-100 Based on the Acuity TM hardwire glassbreak detector Detects all types of breaking glass -Plate, laminated, safety and tempered Can be tested using the glassbreak simulator (AFT-100) Built-in tamper switch Addressable Photoelectric Smoke Detectors FSB-210 SERIES Automatic drift compensation Easy-maintenance removable smoke chamber Non-contact sensitivity reading with handheld test meter (FSD-100) Self diagnostics UL listed Addressable Point / Contact Modules AMP-700 / AMP-701 / AMP-701NP / AMP-702 / AMP-704 / AMP-704F AMP-700 door/window contact with built-in reed switch AMP-701 door/window contact with normally closed input AMP-701NP universal addressable point module AMP-702 fire point module with normally open, EOL resistor supervised input AMP-704 4-zone door/window contact with normally closed, single or double EOL inputs AMP-704F 4-zone normally open fire input module Loop Repeater / Isolator Module AMX-400 Can be used to repeat and re-power the AML loop to allow for longer wire runs: -Requires 12 VDC power source Will isolate the wire run in the event of a problem Adds additional 170 ma Loop Isolator Module AML-770 Can be used to isolate burglary detectors from fire detectors on the same wire run

DATA INTERFACE MODULES With the installation of data interface modules (PC4401), MAXSYS control panels are able to interface with leading manufacturers of home and building automation products and audio distribution systems to create seamless, fully integrated control solutions. Data Interface Module PC4401 Connect up to 4 modules Capable of performing as either a bidirectional RS-232 interface, PC-Link isolator, printer module or DVACS * communicator (Canada only) * DVACS is a registered trademark of Electro Arts Ltd. Scarborough, Ontario, Canada. MODULES Real-time zone status Fully programmable 4-wire hook-up to COMBUS FCC and IC listed MAXSYS zone expanders can add eight zones or 16 zones where needed. Simply connect them to the COMBUS for flexible, efficient and distributed zone expansion. 8 /16 Hardwire Zone Expanders PC4108A / PC4116 PC4108A adds 8 hardwire zones PC4116 adds 16 hardwire zones AUX power rated at 250 ma (PTC protected) Power Supply/ Relay Output / COMBUS Repeater Module PC4204CX Connect up to 16 modules Fully supervised for AC failure, low battery and AUX failure 4 programmable form C relays: - Rated at 3 Amps @ 12 VDC 16-Output Module PC4216 Provides 16 programmable outputs: - Rated at 50 ma @ 12 VDC Connect up to 9 PC4216 modules per system POINT & GRAPHIC ANNUNCIATORS When emergencies occur, make certain operating and emergency personnel are able to understand the nature of an alarm and are able to communicate the information needed for swift and effective action. With MAXSYS point or graphic annunciators important, context-sensitive information is never more than a glance away. The annunciators can display up to 144 zone, partition and system events. 32 / 64 Point & Graphic Annunciators PC4632 / PC4664 Egg-crate backplate for flexible LED locations Pre-printed point display transparency Clear transparencies (2) for custom graphics

MAXSYS FIRE PRODUCTS MAXSYS fire products provide all the equipment needed to integrate full commercial fire into any security application. MAXSYS fire products are only approved for North American regulations. PC4020CF LCD4521 PC4701 PS4350R PC4204CXCF PC4702BP Commercial Fire Panel PC4020CF Includes all the features of the PC4020 plus: - PC4050CR cabinet - PC4701 module - Built-in 16 VAC, 40 VA transformer Programmable Fire-Message LCD Keypad LCD4521 Includes all the features of the LCD4501 keypad Red bezel Fire function keys: - Silence Trouble, Silence Bells, Fire Reset, Fire Drill and Lamp Test Dual-Line Dialer Module PC4701 Dual, supervised phone line connections 1 2-wire Class B/Style B supervised smoke alarm zone 1 Class B/Style B waterflow zone Fire alarm and fire trouble form C relays External Battery Charger PS4350R Includes PS4085 multi-rate charger module Includes PT1012 transformer, 12 VDC, 160 VA Space for 60 Ah of rechargeable batteries Commercial Fire Power Supply PC4204CXCF Includes all the features of the PC4204CX Includes PC4052CR cabinet Built-in 16 VAC, 40 VA transformer Dual-Zone Bell Panel PC4702BP Connect up to 4 modules Provides 2 alarm notification circuits: - Rated at 1.8 Amps @ 24 VDC each Fully supervised outputs for open, short and ground fault PTC protected Includes: - PC4052CR red cabinet - 28 VAC, 180 VA transformer

ACCESS CONTROL Monitoring and restricting the individual entry of tens or perhaps a thousand people within a building is not easy. To protect it from theft or damage, MAXSYS allows simple and affordable access control integration with its alarm systems. 2-Reader Access Control Module PC4820 Connect up to 16 modules Multiple reader technologies 2 supervised lock outputs: - 250 ma per output 64 user access levels 99 date schedules 4 holiday groups Arm/Disarm partitions via access control PC4053 beige cabinet included Readers MAXSYS supports a wide range of 26-bit Weigand readers: - Polaris, ioprox, Shadowprox, HID and Kantech XSF Technologies Request-to-Exit Detector T-REX Passive infrared request-to-exit detector with patented X-Y Targeting and DSP (Digital Signal Processing) MAXSYS ACCESS CONTROL KIT This affordable package is the perfect access control starter kit. It has all the essentials you need: control panel, access control module, reader and keys in one low-cost package. And, if needed, the system can be easily expanded. 1 PC4020 control panel 1 PC4820 access control module 1 P225W26 ioprox reader 10 P40KEY ioprox dual-encoded proximity keys

DLS2002SA SYSTEM ADMINISTRATOR SOFTWARE DLS2002SA System Administrator software is the perfect solution for large or multi-location business applications using the MAXSYS control panel. The software is simple to use and gives users the ability to view and change codes, access cards and schedules, as well as view system status, arm/disarm partitions, and view, sort and print the event buffer. The software can be found in the Products area of the DSC website under the password-protected software section. CONCOURSEE X P STRUCTURED CABLING ConcourseEXP is the best value in residential structured cabling. It provides new home builders and home-system integrators with the convenience of a single, comprehensive family of cable management products that are easy to use in applications of all sizes and complexity. ConcourseEXP enclosures and low-voltage modules have been designed to provide seamless integration with MAXSYS control panels and modules. HOME AUTOMATION Imagine a security system that controls home lighting automatically. With MAXSYS control panels lights can be programmed to automatically turn on and off according to a daily, weekend or monthly schedule. These tasks can be controlled by turning any touchtone phone into a fully functional keypad that can be used to monitor and control a security system from home or from anywhere in the world. Telephone Interface & Automation Control Module ESCORT 4580 Turns any touchtone telephone into a talking keypad Programmable labels: - 6 words per label - 240+ word library Built-in X-10 interface: - Supports up to 32 X-10 devices - 16 schedules, 8 modes Available in English, Spanish and French

INTEGRATED SYSTEMS TECHNOLOGY ADDRESSABLE EXPANSION ALTERNATE COMMUNICATIONS FSB-210 SERIES ADDRESSABLE AMB-600 PHOTOELECTRIC ADDRESSABLE SMOKE DETECTORS PET-IMMUNE PASSIVE INFRARED DETECTOR AMA-100 ADDRESSABLE GLASSBREAK DETECTOR AMB-500 ADDRESSABLE CEILING-MOUNT P ASSIVE INFRARED DETECTOR AMP-700/AMP-701 AMP-701NP/AMP-702 AMP-704/AMP-704F ADDRESSABLE CONTACT MODULES AMB-300 ADDRESSABLE PASSIVE INFRARED DETECTOR 2-WIRE ADDRESSABLE LOOP(S) GS3050-A GSM UNIVERSAL WIRELESS ALARM COMMUNICATOR T-LINK TM TL250 INTERNET ALARM COMMUNICATOR GS3050-I GSM UNIVERSAL WIRELESS ALARM COMMUNICATOR T-LINK TM NETWORK ALARM COMMUNICATOR SERIAL INTERFACE PC4401 DATA INTERFACE MODULE AML-770 LOOP ISOLATOR MODULE AMX-400 LOOP REPEATER/ ISOLATOR MODULE FIRE ALARM WIRELESS EXPANSION 4-WIRE COMBUS WLS925L-433 WLS904PL-433 WIRELESS DOOR/ WIRELESS PASSIVE WINDOW CONTACT INFRARED DETECTOR WLS914-433 WIRELESS PET-IMMUNE P ASSIVE INFRARED DETECTOR FSA-210/410 SERIES 2/4-WIRE PHOT OELECTRIC SMOKE DETECTORS LCD4521 PROGRAMMABLE FIRE-MESSAGE LCD KEYPAD PC4632/4664 32/64 POINT & GRAPHIC ANNUNCIAT ORS PS4350R EXTERNAL BATTERY CHARGER WLS912L-433 WIRELESS GLASSBREAK DETECTOR WS4916 WIRELESS PHOTOELECTRIC SMOKE DETECTOR PC4164-433 WIRELESS RECEIVER PC4701 DUAL-LINE DIALER MODULE PC4702BP DUAL-ZONE BELL PANEL WS4939 4-BUTTON WIRELESS KEY PC4204CXCF COMMERCIAL FIRE POWER SUPPLY WINDOWS SOFTWARE INTRUSION ACCESS CONTROL PC4204CX POWER SUPPLY/ RELAY OUTPUT/ COMBUS REPEATER MODULE LCD4501 PROGRAMMABLE- MESSAGE LCD KEYPAD PC4820 2-READER ACCESS CONTROL MODULE T-REX TM REQUEST-TO- EXIT DETECTOR DLS2002SA SYSTEM ADMINISTRATOR TM SOFTWARE A UTOMATION DLS2002 DOWNLOADING SOFTWARE PC4108A/PC4116 8/16 HARDWIRE ZONE EXPANDERS PC4216 16 PROGRAMMABLE OUTPUT MODULE MULTIPLE READER TECHNOLOGIES ESCORT TM 4580 TELEPHONE INTERFA CE & AUTOMATION CONTROL MODULE LOCAL/REMOTE CONTROL WITH VOICE PROMPT

LISTINGS AMERICAN LISTINGS Category Description Applicable Standard APAW Police station alarm units (commercial burglary) UL365, UL1635 AMCX Central station alarm units (commercial burglary) UL1610, UL1635 AOTX Local alarm units (commercial burglary) UL609, UL1635 NBSX Household burglar alarm units UL1023 UTOU Control units and accessories UL985 UOJZ Control units system (commercial fire) UL864 ALVY Access control system units UL294 CANADIAN LISTINGS Description Central station fire alarm system units Central monitoring station burglar alarm system units Local alarm units (commercial burglary) Household burglar alarm system units Household fire warning system units Access control system units Applicable Standard CAN/ULC-S527 CAN/ULC-S302 CAN/ULC-S303 CAN/ULC-S310 CAN/ULC-S545 UL294 EUROPEAN LISTINGS This product is in conformity with EMC directive 89/336EEC, R&TTE directive 1999/5/EC and low voltage directive 73/23/ECC based on results using the harmonized standards: CISPR Class B, EN50130-4, TBR21, EN60950-1. A USTRALIAN LISTINGS The product carries the A-Tick, Australian compliance mark, indicating that it meets the minimum safety and network integrity standards set by the ACA and can legally be connected to the telecommunications network in Australia. P/N 30000350 R001 Printed in Canada CHINESE LISTINGS Certification under MII (Network Access License) and CCC (Burglar Alarm Systems) CCC Standard: General Specifications for Burglar-Alarm Control Units GB 12663-2001 MII standards: GB/T 15279-2002,YD/T 868-1996, YD/T 968-2002, YD/T 965-1998, YD/T 993-1998 Distributed by: For product information www.dsc.com Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. 2006 2006 05