Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2



Similar documents
Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

MS/MS analysis of Polyphenols

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Overview. Purpose. Methods. Results

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

A Streamlined Workflow for Untargeted Metabolomics

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

LC-MS/MS for Chromatographers

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

RapidFire for High Throughput Screening in early Drug Discovery

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Mass Spectrometry Based Proteomics

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Pesticide Analysis by Mass Spectrometry

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

New drugs of abuse? A case study on Phenazepam & Methoxetamine

AMD Analysis & Technology AG

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

for mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry

How To Test For Contamination In Large Volume Water

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Background Information

Waters Core Chromatography Training (2 Days)

Chemical analysis service, Turner s Green Technology Group

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

XEVO TQ MS PHARMACEUTICAL APPLICATION NOTEBOOK

is a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals.

Instrumentation. Sample pretreatment

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

High Resolution LC-MS Data Output and Analysis

Analyst Software. Advanced User Guide

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry

Supplementary Materials and Methods (Metabolomics analysis)

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Analyzing Small Molecules by EI and GC-MS. July 2014

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Transcription:

Technical ote Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Alek. Dooley, Carmai Seto, esham Ghobarah, and Elliott B. Jones verview: Integration of UV and MS data is highly desirable for biotransformation studies. For example, in vitro metabolic stability studies can provide qualitative metabolism data, as well as kinetics for the parent compound using the MS data. Relative quantitation of metabolites detected can also be performed and integration of UV data is very useful for this aspect of the workflow. Manual processing and correlation of both data streams is time consuming. ere, we show qualitative and quantitative data collected by acquiring both mass spectrometric and UV data in the same experiment, and then processing and correlating both data types automatically in LightSight software version 2.2. Introduction: Drug metabolism studies often require estimation of relative abundances of metabolites detected in addition to structure elucidation. While MS based detection is a powerful technique for detection and structure elucidation, small changes in the structure and functional groups present in a metabolite can often lead to major differences in ionization efficiency and fragmentation. Therefore, it is often difficult to estimate metabolite concentrations based on the MS signal in the absence of a reference standard for quantitation. By comparison, UV absorbance is considered to provide a more uniform response which allows for estimation of relative abundances of metabolites. Integration of MS and analog data processing is highly desirable as it allows the drug metabolism scientist to perform structure elucidation based on the MS/MS data, estimate concentration based on the UV data, and generate one integrated report. In this technical note, we describe the use of LightSight software version 2.2 to study the in vitro metabolism of bromocriptine using a QTRAP LC/MS/MS system in combination with integrated UV detection, data processing and reporting. Experimental Conditions: omocriptine was incubated at 50 μm in rabbit liver microsomes using an ADP regenerating system under oxidative conditions at 37 C. After 1 hour, the incubation was quenched with an equal volume of acetonitrile. The supernatant was then diluted 1:5 with water for injection. This gave a final concentration of 5 μm for bromocriptine in the T 0 control.

A 5μL volume of sample was injected onto a Phenomenex Polar-RP PLC column (2 x 50 mm, 4µm). The mobile phase consisted of water (A) and acetonitrile (B), each containing 0.1% formic acid. The gradient (Figure 1) was optimized to ensure sufficient separation of metabolites over a wide polarity range relative to the parent, which eluted at 60% B. Prior to the mass spectrometric analysis, the LC eluent was fed through a Shimadzu SDP20AV dual wavelength detector, set to 302 nm. Predictive multiple reaction monitoring with information dependant acquisition (pmrm-ida) methods were created using LightSight software v2.2 and run on a 4000 QTRAP hybrid triple Figure 1. LC Gradient used to analyze bromocriptine incubations. quadrupole linear ion trap mass spectrometer. With prior knowledge of the parent drug s MS/MS fragmentation, theoretical MRM transitions for metabolites can be generated based on a particular biotransformation set. The pmrm experiments were built using the Phase I comprehensive biotransformation set included in the LightSight software. A total of 166 MRM transitions were included in the pmrm survey scan linked to a single enhanced product ion (EPI) dependent scan. The EPI experiment was acquired at a scan rate of 4,000 Da/sec with dynamic fill time turned on. Structural elucidation and assignment of the MS/MS fragments was performed with the assistance of the ACD/Labs software package. Results and Discussion: Figure 2 shows the molecular structure of bromocriptine, with the sites of MS/MS fragmentation indicated along with the nominal mass of the fragment. The m/z 346 fragment ion was chosen as the Q3 mass for the pmrm method. Compounds with a higher lambda maximum (λ max ) above the typical background solvent absorbance at 100-150 nm, will yield excellent data quality that correlates nicely with MRM data. Therefore bromocriptine which has a λ max of 302 nm was a suitable choice. If there is complementary analog data (PDA, UV, or ADC data such as β-ram) available, LightSight software will correlate the MS data with the analog data and vice versa. The potential metabolites table in the software reports metabolites from both data streams, providing for the integration of both data types as well as ensuring that any potential metabolite that is only detected in one data stream is still reported. Using the Figure 2. The MS/MS fragmentation of bromocriptine LightSight software, a total of 14 metabolites were detected and identified including 11 oxidative metabolites; a summary of the MS and UV data for these metabolites is shown in Table 1. Figure 3 shows the correlation between the MS data and the UV trace performed in the LightSight software

Figure 3. Correlation of UV and MS data in the Processing Workspace of LightSight software version 2.2. R.T. (min.) - Peak Area - % Area - Peak ID Biotransformation Mass Shift Expected m/z Q1 / Q3 R.T. (min) Peak Area % Area Peak eight Analog Analog Analog M1 Demethylation -14 640.2 640.2 / 299.9 6.84 6.39E+04 0.5 7.00E+03 M2 Demethylation -14 640.2 640.2 / 299.9 7.19 3.47E+05 2.9 3.12E+04 M3 Loss of 30-30 624.2 624.2 / 299.9 7.5 3.62E+05 3.1 3.36E+04 M4 Tri-xidation 48 702.2 702.2 / 345.9 7.83 5.33E+04 0.4 7.40E+03 M5 Di-xidation 32 686.2 686.2 / 345.9 8.45 4.28E+05 3.6 5.61E+04 8.48 2.53E+01 2.9 M6 Di-xidation + ydrogenation 34 688.2 688.2 / 347.9 8.63 2.61E+05 2.2 3.40E+04 8.65 1.65E+01 1.9 M7 Tri-xidation + ydrogenation 50 704.2 704.2 / 347.9 8.74 5.39E+05 4.5 3.61E+04 8.65 1.65E+01 1.9 M8 Di-xidation 32 686.2 686.2 / 345.9 8.84 3.52E+06 29.7 4.05E+05 8.86 1.88E+02 21.3 M9 xidation 16 670.2 670.2 / 345.9 9 9.20E+05 7.8 1.10E+05 9.02 7.61E+01 8.6 M11 xidation + ydrogenation 18 672.2 672.2 / 347.9 9.23 1.69E+06 14.3 1.74E+05 9.25 1.70E+02 19.2 M10 Di-xidation 32 686.2 686.2 / 345.9 9.23 7.46E+05 6.3 8.06E+04 9.25 1.70E+02 19.2 M12 xidation 16 670.2 670.2 / 345.9 9.26 1.78E+06 15 1.87E+05 9.25 1.70E+02 19.2 Parent 0 654.2 654.2 / 345.9 9.73 5.25E+05 4.4 5.94E+04 9.7 1.57E+01 1.8 M13 xidation 16 670.2 670.2 / 345.9 9.83 2.52E+05 2.1 3.04E+04 M14 xidation 16 670.2 670.2 / 345.9 10.19 3.19E+05 2.7 4.51E+04 10.2 3.57E+01 4 Parent 0 654.2 654.2 / 345.9 10.71 4.46E+04 0.4 5.80E+03 Table 1. omocriptine metabolites identified using LightSight software sorted by retention time.

The metabolites included single, di-, and tri-oxidations of bromocriptine. The proposed structure of some of the metabolites is shown in Figure 4. Figure 5 shows the comparison between a tri-oxidation metabolite of bromocriptine and the parent MS/MS spectra. The pmrm transition that corresponds to the triple-oxidation metabolite shows 4 clear peaks in the MS chromatogram, and the UV trace further confirms that these peaks are potential metabolites (see Figure 6). 3 C R + 2 3 C R R =, 2 or 3 R =, 2 or 3 M9, M12, M13, M14: xidation M4: Tri-xidation M5, M6, M8, M10: Di-xidation M11: xidation + ydrogenation M6: Di-xidation + ydrogenation M7: Tri-xidation + ydrogenation Figure 4. Proposed structures for metabolites of bromocriptine detected in the microsomal incubation.. C + 3 + 3 C +MSMS of 686.2 (Di-xidation) Intensity, cps Intensity, cps 1.0e6 8.0e5 6.0e5 4.0e5 2.0e5 0.0e0 +MSMS of 654.2 (Parent) 1.5e5 1.0e5 5.0e4 0.0e0 207.2 301.0 205.9 303.1 222.1 286.0 221.0 258.0 299.0 329.0 223.2 264.2 270.1 339.0 179.0 191.2 271.9 315.0 249.2 346.0 355.1 383.0 398.2 100 150 200 250 300 350 400 450 500 550 600 650 700 124.0 C + 3 + m/z, Da 100 150 200 250 300 350 400 450 500 550 600 650 700 m/z, Da 426.1 426.4 C + C + 301.1 207.2 346.2 303.0 383.0 258.1 206.2 298.9 221.3 224.0 286.1 348.4 355.1 385.1 260.3 275.2 302.5 193.3 426.1 153.0 178.2 428.2 327.1 357.2 234.1 3 C - 2 636.4 668.2 654.1-2 686.3 Figure 5. The comparison between bromocriptine (bottom panel) and a di-oxidation metabolite reveals that all the fragments at or below m/z 426.1 are common between both spectra Therefore, the sites of metabolism do not occur on these portions of the parent drug.

Figure 6. The selected ion chromatogram for the di-oxidation metabolites of bromocriptine (top) and the UV chromatogram (bottom). Conclusions: LightSight software version 2.2 efficiently identifies, confirms, and quantitates metabolites using both MS and analog data. Identification and structure elucidation based on the MS and MS/MS data, and relative quantitation based on UV were both performed in a singe integrated workspace.. For Research Use nly. ot for use in diagnostic procedures. The trademarks mentioned herein are the property of either Life Technologies Corporation, Applied Biosystems/MDS Analytical Technologies or otherwise, their respective owners. 2009 Applied Biosystems LLC and MDS Inc. Joint wners. All rights reserved. eadquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone 650.638.5800 Toll Free 800.345.5224 www.appliedbiosystems.com International Sales For our office locations please call the division headquarters or refer to our Website at www.appliedbiosystems.com/about/offices.cfm