Instructions for transferring the SINUMERIK HMI to an external screen



Similar documents
Remote Monitoring and Control of the R&S FSV with a Web Browser

AVer EVC. Quick Installation Guide. Package Contents. 8. Mini Din 8 pin MIC Cable. 1. Main System. 9. HDMI Cable. 2. Camera. 10.

Infinity C Reference Guide

Remote Monitoring and Control of the R&S FSL with a Web Browser

Immotec Systems, Inc. SQL Server 2005 Installation Document

Elluminate Live! Access Guide. Page 1 of 7

Install MS SQL Server 2012 Express Edition

Elluminate Live! Access Guide. Page 1 of 7

Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents

Interactive Whiteboard Functionality Overview Choosing Pen Style Erasing / Modifying Writing Undo / Redo

Self Help Guide. Please read the following carefully; Synopsis: Requirements: A Computer with a working RJ45 LAN Port All Belkin Modem Routers

Guide to Setting up Internet Connection Sharing for Windows

Network Projector Operation Guide

Access Grid Setup Instructions

The initial set up takes a few steps, but then each time you want to connect it is just a two set process.

How to Program a Commander or Scout to Connect to Pilot Software

Interfacing Basler GigE Cameras With Cognex VisionPro 7.2

Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)

TE100-P21/TEW-P21G Windows 7 Installation Instruction

Quick Installation Card

801.11n Wireless Broadband Router

Step by step guide for connecting PC to wired LAN at dormitories of University of Pardubice

Host Installation on a Terminal Server

CONNECTING THE RASPBERRY PI TO A NETWORK

Remote Access and Control of the. Programmer/Controller. Version 1.0 9/07/05

Debug Failed to connect to server!

X Series Application Note 43:

BR-800. ProHD Broadcaster. Easy Set-Up Guide V 1.01

V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

ShareLink 200 Setup Guide

Integration of DTV Recorder Generator DVRG into a TCP/IP Network

Creating a Client-To-Site VPN. BT Cloud Compute. The power to build your own cloud solutions to serve your specific business needs.

802.11n Wireless Broadband Router WNRT-625

Installation and Connection Guide to the simulation environment GLOBAL VISION

Quick Installation Card

HOW-TO-GUIDE. Installer Service Tool: Downloading Data and Event Logs for the Eltek Theia

Quick Start Guide NVR DS-7104NI-SL/W NVR. First Choice For Security Professionals

(1) Network Camera

Scan to SMB(PC) Set up Guide

WIRELESS TRAINING SOLUTIONS. by vlogic, Inc. L a b 0.3 Remote Access Labs

Self Help Guide IMPORTANT! Configuring Your Router With Your Modem. Please read the following carefully; This Guide refers to the following Products:

Configuring a customer owned router to function as a switch with Ultra TV

Initial Setup. How To Run A Mac Server:

Quick Start Guide. Sendio System Protection Appliance. Sendio 5.0

CMP-102U. Quick Installation Guide

Connecting the DG-102S VoIP Gateway to your network

Recommended Network Setup

Introduction. Before you begin. Installing efax from our CD-ROM. Installing efax after downloading from the internet

AVer EVC. Quick Installa on Guide. Package Contents. 8. Mini Din 8 pin MIC Cable 9. HDMI Cable

How to Remotely View Security Cameras Using the Internet

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

8/16-Port IP KVM Switch IKVM-8010 / IKVM Quick Installation Guide

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

Application Note 8: TrendView Recorders DCOM Settings and Firewall Plus DCOM Settings for Trendview Historian Server

Service & Support. How do you create a communication of RDP with an Industrial Thin Client SIMATIC ITC? Thin Client.

Technical Support Information

NTP Receiver/Software Installation Guide

Important Notes for WinConnect Server VS Software Installation:

Network/Floating License Installation Instructions

CONNECTING TO DEPARTMENT OF COMPUTER SCIENCE SERVERS BOTH FROM ON AND OFF CAMPUS USING TUNNELING, PuTTY, AND VNC Client Utilities

DUKANE Intelligent Assembly Solutions

Remote Connectivity to XV, XP and epro units running Visual Designer

educ Office Remove & create new Outlook profile

Metasys System Direct Connection and Dial-Up Connection Application Note

Movie Cube. User s Guide to Wireless Function

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

Remote Desktop In OpenSUSE 10.3

Setting up your laptop to print to the student lounge printer

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

SETTING UP REMOTE ACCESS ON EYEMAX PC BASED DVR.

DATA PROJECTOR XJ-A147/XJ-A247/XJ-A257 XJ-M146/XJ-M156 XJ-M246/XJ-M256. XJ-A Series. XJ-M Series. Network Function Guide

Ultra Thin Client TC-401 TC-402. Users s Guide

SCDSB Video Conferencing

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

How to install and use CrossTec Remote Control or SchoolVue in a Virtual and or Terminal Service environment

Enabling NAT and Routing in DGW v2.0 June 6, 2012

Quick Network Setup Guide

29 ThinManager Troubleshooting Guide

C-more Remote Access with Apple ipad or iphone Tutorial

Setup for Windows XP Connect to your Windows XP machine with: FileBrowser, NetPortal & ServerControl

EasyMP Multi PC Projection Operation Guide

SGUL VPN Connection Guide for Windows 10

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

ipad Installation and Setup

Instructions. Setup of Teamviewer VPN. programming remotely With STEP7.

Amcrest 960H DVR Quick Start Guide

1. Hardware Installation

Attachment E ACCESSING THE FCC NETWORK USING WINDOWS 95/98 FOR ULS FILING

Using LifeSize systems with Microsoft Office Communications Server Server Setup

One of the following messages will appear in red when DisplayStudio is not properly connected to a media player on the wireless network.

Application Note Configuring the UGate 3000 for use with ClipMail Pro and ClipExpress

Configuring the WT-4 for ftp (Ad-hoc Mode)

Printing Options. Netgear FR114P Print Server Installation for Windows XP

Connecting to the Staff Desktop Service

19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS

SSL Enforcer Documentation

Transcription:

Instructions for transferring the SINUMERIK HMI to an external screen SINUMERIK 828D with UltraVNC-Viewer and Notebook In many cases it may be useful to transfer the SINUMERIK HMI on an external monitor, be it a notebook, a monitor or other display or projector. In particular, for training purposes or presentations is a great representation of SINUMERIK HMI very helpful. About the RJ45 Ethernet port on the front of the SINUMERIK 828D a connection between the controller and notebook will be established using the UltraVNC Viewer. The SINUMERIK HMI appear as an extra window on the notebook. This signal can be transferred to another monitor or other display. A detailed description of the procedure can be found in this document.

Table of Contents 1. Introduction 2 2. Startup and Configuration 3 3. Troubleshooting 11 4. Further information and internet 14 1. Introduction To display the contents of the SINUMERIK HMI on an external display, you need a physical connection and special software, which transfers the image of the controller (server) to another laptop / computer (client). From the notebook or the computer the signal can then be passed on to another monitor / display. UltraVNC (even Ultr @ VNC, UVNC) is a Virtual Network Computing software for Microsoft Windows operating systems and is used for remote maintenance of computers. This has powerful techniques for intercepting the server screen (SINUMERIK HMI). From the client (laptop / computer), the controller can be operated remotely and via mouse and keyboard. To transfer the SINUMERIK HMI to an external monitor, you need the following components: SINUMERIK 828D Network cable (connecting SINUMERIK 828D and notebook / computer) External monitor / screen / display / TV VGA / HMDI cable (connecting laptop / computer to the external display) notebook / computer with a Windows operating system UltraVNC-Viewer (OpenSource Software www.uvnc.com) The following descriptions are intended for operators of CNC machines who have experience with or knowledge of the SINUMERIK CNC with SINUMERIK Operate user interface. Basic knowledge of network technology and experience with the Windows operating systems are helpful. 2/14

2. Startup and Configuration Steps on the SINUMERIK 828D 1. Connect network cable to the front of the SINUMERIK 828D. 2. Press the Diagnostics softkey in the machine basic screen at the control. 3/14

3. Press the Remote diagnostics softkey. 4. Press the Change softkey. 4/14

5. Make settings as shown in the screen. Click OK to complete. 5/14

Steps at the PC/Notebook/Computer 6. At the PC open the properties of the LAN ports (For Windows 7: Control Panel> Network and Internet> Network Connections). Highlight the LAN port and select the context menu Properties. Highlight Internet Protocol (TCP / IP) and click Properties. Make sure, that IP address automatically is activated. Then connect network cable to PC. 6/14

7. The assigned IP and the control IP(Standard gateway) can be seen under the status of the LAN port in the "Network support" tab. 8. Install UltraVNC on your PC. Current Version Download UltraVNC (http://www.uvnc.com/downloads/ultravnc.html). Download from older versions on www.sinupedia.de. UltraVNC Windows 32bit http://www.sinupedia.de/images/downloads/computer_files/windows/ultravnc_1_1_8_x86_setup.exe UltraVNC Windows 64bit http://www.sinupedia.de/images/downloads/computer_files/windows/ultravnc_1_1_8_x64_setup.exe 7/14

9. Open UltraVNC and enter the IP of the controller (192.168.215.1). Standard IP of the front-panel interface X127. The screen contents can be scaled under Options. Click the Connect button in order to connect to the controller. 8/14

10. A password query may appear after the Connect button has been pressed. The password is password. 11. The control now displays the following screen that has to be confirmed with OK within 10 seconds. 9/14

12. The PC screen on one monitor can now be transferred via a video output (VGA, HDMI etc) to an external monitor, projector or similar device. 10/14

3. Troubleshooting If, despite these instructions, it proves impossible to set up a VNC connection, the reason might be the SINUMERIK firewall settings. 1. Press the Setup softkey in the machine basic screen. 11/14

2. Press the System data softkey. 3. Look for the INI file "basesys" in the system data manager. See screenshot for folder structure. 12/14

4. Open the basesys.ini file and search for the word "FIREWALL" using the search function. 5. Remove the semi-colon in front of the entry. As a consequence, the ports are enabled. Close the file, switch off the machine at the main switch and then switch it on again. 13/14

4. Further information and internet Manuals and information from the Siemens AG Manuals and detailed information about our products can be found at the following Websites: DOConWEB (www.automation.siemens.com/doconweb) Service & Support Portal (www.support.automation.siemens.com) SINUMERIK Website (www.siemens.com/sinumerik) 14/14