CONFIGURABLE SAFETY RELAYS



Similar documents
CONFIGURABLE SAFETY RELAYS

MSI-s/R. Modular Safety Interface. CONNECTING AND OPERATING INSTRUCTIONS Original Instructions. without prior notice /05.

SAFETY LIGHT CURTAINS

Safety automation solutions

SMS 4 / SMS 5 safety mat Product information

E-STOP relays, safety gate monitors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Preventa Machine Safety Products

PNOZsigma - Base units

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Safety Relays ESM/ESM-F

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

Digital display DA 48

Contact expander modules

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Safety Manual BT50(T) Safety relay / Expansion relay

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Contact expansion modules

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Smart DeviceNet Remote I/O Terminals

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

E-STOP relays, safety gate monitors

HERZ-Thermal Actuators

Machine Safety Design: Safety Relays Versus a Single Safety Controller

Electronic Control Devices The European Product Catalogue 2007

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Safety technique. Emergency stop module BO 5988 safemaster

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Original instructions Tina 3A/Aps Adaptor unit

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Quick Connect. quick - simple - efficient.

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Three-phase monitoring relay CM-PFE

Electrical connection

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Barcode Reader Series BCL 31, BCL 32, BCL 34

E-STOP relays, safety gate monitors

NX safety stand-alone

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, GLP, EM, and EMD) Selection Guide

E-STOP relays, safety gate monitors

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Digital input modules

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Inductive sensor NI10-M18-Y1X-H1141

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

PNOZ s3. Safety relays. Operating Manual EN-10

Tina 2A/B Adaptor unit

E-STOP relays, safety gate monitors

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Thermistor motor protection

38 Series - Relay interface modules A

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Multizone Application >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

E-STOP relays, safety gate monitors

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Model: DC-A2IO Advanced HVAC Controller

Flexible Counter Series in DIN size 24 x 48 mm

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PHOENIX CONTACT Features

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

DALI RC BASIC SO. Control unit Operating instructions

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SAFETY MANUAL SIL Switch Amplifier

38 Series - Relay interface modules A

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

How To Use A Flowmeter

J TB/TW Temperature limiter, temperature monitor

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

MINI MCR-SL-R-UI(-SP)

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Remote Monitoring and REC 501 Control Unit Product Guide

RM4TG20 three-phase network control relay RM4-T - range V

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MasterINTERFACE 39 Series - Relay interface modules

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Preset Counter signo 721

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Transcription:

MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional E-STOP control device or Safety Switch can be connected (MSI-sx/Rx) Relay switching cycle counting for preventive maintenance (MSI-sx/Rx) Potential-free safety-related switching outputs Contact load rating, 5 A Plug-in connection terminals and output modules Interface for PC-supported diagnostics and easy start-up Housing width, 35 mm When increased functionality is required in automated production processes, the configurable MSI-s and MSI-sx are preferred over simple. These configurable MSI type 4, in accordance with IEC/ EN 6496-, can be flexibly connected as the link between opto-electronic protective devices and the machine control unit. In addition to standard functions such as start/restart interlock and contactor monitoring they also feature a type test monitoring. The MSI-sx ("extended") model also enables the connection of E-STOP control devices or Safety Switches. Furthermore switching cycles can also be counted and automatically signal when a pre-selected value is reached. Preventive maintenance is possible with this warning in good time before a device failure, which in turn provides additional reliability with regard to system availability. Typical areas of application MSI-s/R as interface module between opto-electronic protective devices, type 4, type 3 or type and the machine control system MSI-sx/Rx for systems with combined application of Light Beam, Safety Switches and E-STOP control devices; stop category 0 (IEC 6004-) TNT 35 p. 478

MSI-s/R, MSI-sx/Rx Safety Switches Important technical data, overview Type in accordance with IEC/EN 6496- (Annex A) SIL in accordance with IEC 6508 and SILCL in accordance with IEC/EN 606 Performance Level (PL) in accordance with EN ISO 3849- Category in accordance with EN ISO 3849 Stop category in accordance with IEC/EN 6004- Type 4 Up to 4 (depending on the category of the upstream protective device) 0 Supply voltage 4 V DC, ±0 % Response time to 64 ms depending on safety sensor Safety-related switching outputs (OSSDs) Secondary switching device (SSD), only MSI-sx/Rx Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D) Functions MSI-s/R: relay outputs (NO) MSI-sx/Rx: 3 relay outputs ( NO, NC) Relay output (NO) 0...+55 C -5...+70 C 35 mm x 99 mm x 3.6 mm Max. number of type AOPDs or E-STOP control devices (category ) Max. number of type 4 AOPDs or E-STOP control devices (category 4) MSI-s/R MSI-sx/Rx 4 Start/restart interlock (RES), optionally with/without Static contactor monitoring (EDM) Dynamic contactor monitoring (EDM) Cross circuit monitoring PC diagnostics interface Relay switching cycle counter for preventive maintenance System error signal output Secondary switching device (SSD) output Features Further information Page Ordering information 45 Electrical connection 45 Technical data 453 Dimensional drawings 455 Accessories ordering information 456 BG geprüft Safety Locking Safety Command Configurable Accessories Glossary Product Finder www.leuze.com/interfaces/ 45

Ordering information MSI-s/R, MSI-sx/Rx Included in delivery: Connecting and operating instructions Functions: Start/restart interlock, contactor monitoring, PC diagnostics interface MSI-s/R, MSI-sx/Rx Art. no. Article Description Safety-related switching outputs (OSSDs) 549900 MSI-s/R Configurable MSI Safety Relay relay outputs 54990 MSI-sx/Rx Configurable MSI Safety Relay,extended functions 3 relay outputs Electrical connection, MSI-sx/Rx connection example +4V +4V -A5 -K5 -W 4 S00-M3C-M0 -W 3 4 5 6 -K4 -K3 L+ L- -A 4 -A 3 4 5 6 -A3 4 5 4 3 6 7 3 4 +4V n.c. Test Start Restart +4V EDM RES active OSSD OSSD +4V T T S S S3 S4 Test AOPDs Reset EDM SOLID-4E / SD4T FE 3 5 SOLID-4E / SD4R-E FE 7 8 MSI-sx/Rx Diagn. RS3 9 MSIfault State 8 FE (via DIN rail) Rx-Output Warn. State OSSD OSSD3 5 7 6 0 OSSD SSD 3 -W 3 SH -W 7 S -K3 -K3 A A -K4 A A PE Var. A -K3 -K4 -K4 -K5 -K5 Var. B L- -K5 L- A A L+ PE Configurable MSI-sx/Rx Safety Relay with SOLID-4 Safety Light Curtain and S00 Safety Switch Please observe the operating instructions of the components! 45 We reserve the right to make changes 5-0_MSI-S_SX.fm 00 Leuze electronic GmbH + Co. KG

MSI-s/R, MSI-sx/Rx Safety Switches Technical data General system data Type in accordance with IEC/EN 6496- (Annex A) Type 4 SIL in accordance with IEC 6508 and SILCL in accordance with IEC/EN 606 Performance Level (PL) in accordance with EN ISO 3849- Service life (T M ) in accordance with EN ISO 3849- Probability of a failure to danger per hour (PFH d ) in nop = 4,800 accordance with the average number of annual nop nop = 8,800 activations (for the calculation formula, see EN ISO 3849-:008, chapter C.4. and C.4.3) nop = 86,400 With DC (ohmic load) With AC (ohmic load) Number of cycles until 0 % of the components have With DC3 (inductive load) a failure to danger (B 0d ) With AC5 (inductive load) Low load (0% nominal load) Category in accordance with EN ISO 3849 Up to 4 (depending on the category of the upstream protective device) Stop category in accordance with IEC/EN 6004-0 Supply voltage 4 V DC, ±0 % ms with connection of type 4 AOPD with transistor output Response time 64 ms with connection of type 4 AOPD with relay output 64 ms with connection of type AOPD 64 ms with connection of Safety Switches (electro-mechanical) Restart delay time 00 ms Safety class II Protection rating IP 0 Ambient temperature, operation 0...+55 C Ambient temperature, storage -5...+70 C Relative humidity Max. 93 % Dimensions (W x H x D) 35 mm x 99 mm x 3.6 mm Mounting on 35 mm DIN rail Connection system Plug-in, encoded screw terminals up to.5 mm Current consumption Approx. 00 ma without external load Safety-related switching outputs (OSSDs) MSI-s/R: relay outputs (NO) MSI-sx/Rx: 3 relay outputs ( NO, NC) Secondary switching device (SSD), only MSI-sx/Rx Relay output (NO) Switching voltage, switching current (for OSSDs) 60 V DC, 50 V AC, 5 A maximum, 0 ma minimum Test interval, 00 ms Test outputs T and T Test pulse width delayed, 4 ms each Response time, type AOPD on test request,...8 ms Control inputs Start/restart interlock (RES) Potential-free NO contact (button or key switch) Contactor monitoring (EDM) Feedback of positive-guided contacts of sequential contactors Safety Locking Safety Command Configurable Accessories Glossary Product Finder www.leuze.com/interfaces/ We reserve the right to make changes 5-0_MSI-S_SX.fm 00 Leuze electronic GmbH + Co. KG 453

Technical data Signal outputs OSSD status Start/restart interlock status Additional signal outputs MSI-sx/Rx MSI error Pre-selected switching cycles reached Connectable safety sensors Safety sensors (AOPDs) Safety Switch/E-STOP control device pnp transistor output pnp transistor output Push-pull transistor output Push-pull transistor output MSI-s/R: type 4 or type 3 AOPD or up to type AOPDs MSI-sx/Rx: Up to type 4 or type 3AOPDs or up to 4 type AOPDs MSI-s/R: Up to Safety Switches in accordance with EN 088 and E-STOP command device in accordance with EN ISO 3850 MSI-sx/Rx: Up to 4 Safety Switches in accordance with EN 088 and E-STOP command device in accordance with EN ISO 3850 Please note the additional information in the connecting and operating instructions and at www.leuze.com/interfaces. 454 We reserve the right to make changes 5-0_MSI-S_SX.fm 00 Leuze electronic GmbH + Co. KG

MSI-s/R, MSI-sx/Rx Safety Switches Dimensional drawings Configurable MSI-s/R and MSI-sx/Rx Safety Locking 4 5 3 3 4 5 6 6 7 8 3 4 5 6 3 4 5 6 7 8 Safety Command Warn. Diagn. Diagn. State Locked Fault Rx - Output 7 8 9 0 S3 & S4 S & S MSI Fault MSI- sx 9 0 3 4 State Locked Fault R - Output 8 9 7 0 MSI S & S Fault MSI- s 9 0 3 4 99.0 35 Configurable Dimensions in mm Our 3D CAD models can be found under: www.leuze.com/3d-cad-models. Accessories Product Finder Glossary 35 3.6 www.leuze.com/interfaces/ We reserve the right to make changes 5-0_MSI-S_SX.fm 00 Leuze electronic GmbH + Co. KG 455

Accessories ordering information Art. no. Article Description Length, design Diagnostics set 54993 MSI-SWC MSI diagnostics set contains: MSI diagnostics software*, Ger/Eng user's guide, diagnostics cable, 3 m Diagnostics cable 549953 CB-MSI/D9-3000 Diagnostics connecting cable 3 m 549955 CB-MSI/D9-5000 Diagnostics connecting cable 5 m 549950 CB-MSI/D9-0000 Diagnostics connecting cable 0 m Power supplies 5006 LOGO! Power Power supply, 0/30 V AC --> 4 V DC /.3 A, regulated *) MSI diagnostics software All configurable MSI have an RS 3 diagnostics interface for the PC-supported visualization of input and output states, and internal system states. This allows wiring and cabling errors, insufficient input information and the system status to be quickly and easily detected. You will find more information at www.leuze.com/interfaces. 456 We reserve the right to make changes 5-0_MSI-S_SX.fm 00 Leuze electronic GmbH + Co. KG