Nucor VR16 II TM Vertical Rib Standing Seam Roof System



Similar documents
METAL BUILDING SYSTEMS

PRODUCT SPECIFICATIONS

Standing Seam Roof Systems

SECTION STANDING SEAM METAL ROOF

CHAPTER 7: Building Systems ROOFING SYSTEMS

VERTICAL LOCK Table of Contents

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DENVER MODEL 30 X 30 SPECIFICATIONS

stand the tests of time, & economics

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

metal Duil~ing manufacturers Association

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

GUIDELINE SPECIFICATIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

SECTION PREFORMED METAL STANDING SEAM ROOFING

COLORADO MODEL. 35 x 65 SPECIFICATIONS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

DIVISION 07. Architectural Sheet Metal. Weathertight Warranties. Rollforming Equipment. 50+ Years of SSMR, Installation & Technical Experience

ABSeam Panel Overview and Installation Instructions

238T Standing Seam Metal Roof System (SSMRS)

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Technical Installation Information

SECTION METAL WALL PANELS

Double-Lok. Technical/Installation Information

METAL ROOF & WALL SYSTEMS

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

CENTRIA SRS3 Structural Standing Seam Metal Roof Panels

Quality Metal Roofing Products

A. Double lock standing seam, single element, metal roof panels.

STRUCTURAL STANDING SEAM ROOF SYSTEMS

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

metals LLC Metal roofing ON-DEMAND

LokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

Slim Seam Architectural Design Manual

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

TremLock Metal Roofing and Wall Solutions

SECTION STANDING SEAM METAL ROOFING

Technical Installation Information

Installation Manual for STANDING SEAM ROOFING

SECTION METAL ROOF & WALL PANELS

STANDING SEAM METAL ROOFING DETAILS PDF

City of San Diego, CWP Guidelines

ATLANTA MODEL SPECIFICATIONS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

PART 1 GENERAL 1.1 SECTION INCLUDES

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Discipline: Structural Issued

How To Design A Post Tensioned Deck For A Building

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

Metal Roof Systems in High-Wind Regions

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

STANDING SEAM METAL ROOFING PANELS

Preformed Metal Roofing and Siding

Chapter 6 ROOF-CEILING SYSTEMS

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

SECTION PREFORMED METAL ROOF PANELS

Assessing Curtain Walls

Designer Series. Technical/Product Information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

Residential Metal Roofing

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept


Mechanically Seamed Roof System Design / Installation Information

Installation Detailed installation instructions are provided which should be strictly followed.

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

PRO-PANEL II. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information

Section 5A: Guide to Designing with AAC

Residential Roofing Guide

TechPractices: Home Front Homes:

Versa-Span STRUCTURAL STANDING SEAM

Impact-Resistant Windows and Sliding Glass Doors

SECTION STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Metal Roofing Practical Design

Light Gauge Panels. Metal Sales Manufacturing Corporation

What makes DECRA Roofing Systems unique?

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Design & Installation Solutions

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

metal architectural systems

Your Guide To Retrofit Sub-Framing Solutions

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Rouse Life Sciences Roof Repair or Replacement SECTION

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

ISO Types 1-6: Construction Code Descriptions

SUNPAL Multiwall Polycarbonate Standing-Seam Architectural System

Transcription:

Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com

Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is a Structural Standing Seam Vertical Rib Panel that is perfect for architectural requirements in today s marketplace. Nucor VR16 II Ro System panel is a weathertight system that is an ideal solution for buildings with hips and valleys, and easily accommodates complex ro geometries. The VR16 II ro panel fers an attractive architectural ro system available both in Galvalume and PVDF finishes as standard. Panels are installed with concealed fastener clips allowing for thermal movement, and mechanically seamed for weather tightness. Nucor VR16 II Warranties 25 Year Galvalume Finish 35 Year PVDF Paint Finish 20 Year Weathertightness For specific details, please refer to the Warranty Guide at www.nucorbuildingsystems.com. Galvalume is a registered trademark BIEC International, Inc.

Performance and Testing AISI Gravity & Uplift Base Testing ASTM E108 Test Methods for Fire Tests Ro Coverings ASTM E283 Test Method for Determining Air Leakage through Wall Systems ASTM E1592 Test Method for Wind Uplift Performance Sheet Metal Roing Systems ASTM E1646 Test Method for Water Penetration Exterior Ro Systems ASTM E1680 Test Method for Rate Air Leakage through Exterior Ro Systems FM Simulated Hail Damage Testing Class SH Hail Resistance US Army Corps Engineers Approved per CEGS 07416 test specification Panel Ratings Gauge Secondary Spacing Seam Option Factory Mutual 1-60 24 Purlins or Joists 5'-0" Nucor Vise Lock 360 Factory Mutual 1-90 24 Purlins or Joists 3'-4" Nucor Vise Lock 360 Factory Mutual 1-120 24 Purlins or Joists 2'-6" Nucor Vise Lock 360 Factory Mutual 1-180 22 Purlins or Joists Varies Nucor Vise Lock 360 UL90 24 Purlins or Joists 5'-0" Nucor Vise Lock /Vise Lock 360 Florida Approval 24 Purlins or Joists 5'-0" Nucor Vise Lock /Vise Lock 360 Miami Dade 22 Purlins or Joists 5'-0" Nucor Vise Lock /Vise Lock 360

Product Specifications & Details VR16 II Panel Options Rib height: 2 Cover width: 16 Galvalume finish Factory sealant continuously applied along female rib Minor striations to help reduce oil canning Painted PVDF finishes Standard 24 gauge material (22 gauge also available) Mechanically seamed for weathertight installation Panel installed with concealed fastener clips that allow for thermal movement 1/4:12 Minimum ro slope required Standard Optional VR16 II Seaming Options Nucor Vise Lock tmseam "VISE LOCK" SEAM Nucor Vise Lock 360 tmseam "VISE LOCK 360" SEAM

Panel Properties Designated Gage Steel Steel Yield KSI Engineering Properties Nucor Building Systems 16" Nucor Vise Lock Seam Panel Base Metal Thick.(In) Total Thick. (In) Panel Weight (lbs/ ft 2 ) Ix (In 4 / ft) Top In Compression Sx (In 3 / ft) Bottom In Compression 1. Panels are checked for bending (B), shear (S), combined bending and shear(b+s), and deflection (D). The controlling check is noted in the table. Deflection was limited to span/60. 2. Section Properties have been calculated in accordance with the 2007 North American Specification for the Design Cold-Formed Steel Structural Members. 3. Minimum yield strength 24 and 22 gage steel is 50,000 psi. 4. Steel panels are either aluminum-zinc alloy or G-90 coated. The base metal thickness was used in determining section properties. 5. Positive load (POS) is applied inward toward the panel supports and is applied to the outer surface the full panel cross-section. Ma K-IN Ix (In 4 / ft) Sx In 3 / ft) 24 Ga. 50 0.0225 0.0241 1.35 0.166 0.099 2.96 0.073 0.061 1.83 30 22 Ga. 50 0.0300 0.0316 1.77 0.225 0.141 4.22 0.110 0.094 2.83 30 Gage Panel 24 Ga. 22 Ga. Designated Gage Steel Steel Yield KSI No. Spans Load Type Maximum Total Uniform Load in PSF Span Lengths, Ft Ma K-IN Fb KSI 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 1 POS 876 493 316 219 161 123 97 79 2 POS 460 276 183 130 96 74 59 48 3 POS 542 333 223 159 119 92 73 60 4 POS 517 315 210 149 111 86 69 56 1 POS 1250 703 450 312 230 176 139 112 2 POS 735 436 287 202 150 116 92 75 3 POS 875 529 351 249 185 143 114 93 4 POS 831 499 330 234 174 134 107 87 Engineering Properties Nucor Building Systems 16" Nucor Vise Lock 360 Seam Panel Base Metal Thick. (In) Total Thick. (In) Panel Weight (lbs/ ft 2 ) Ix (In 4 / ft) Top In Compression Sx (In 3 / ft) Ma K-IN Ix (In 4 / ft) Bottom In Compression Sx In 3 / ft) 24 Ga. 50 0.0225 0.0241 1.35 0.140 0.078 2.35 0.063 0.056 1.67 30 22 Ga. 50 0.0300 0.0316 1.77 0.195 0.114 3.42 0.095 0.085 2.54 30 Gage Panel 24 Ga. 22 Ga. No. Spans Load Type Maximum Total Uniform Load in PSF Span Lengths, Ft. Ma K-IN Fb KSI 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 1 POS 695 391 250 174 128 98 77 63 2 POS 446 262 171 120 89 68 54 44 3 POS 537 319 210 148 110 85 67 55 4 POS 508 301 197 139 103 79 63 51 1 POS 1013 570 365 253 186 143 113 91 2 POS 697 405 263 184 136 105 83 67 3 POS 846 497 325 228 169 130 103 84 4 POS 798 467 305 214 158 122 96 78

With four full-service plants and a sales fice strategically located throughout the country, Nucor Building Systems has the capacity to meet your needs. INDIANA PLANT 305 Industrial Parkway Waterloo, IN 46793 Ph: 260.837.7891 Fax: 260.837.7384 NE SALES OFFICE 201 Granite Drive Suite 280 Lancaster, PA 17601 Ph: 717.735.7766 Fax: 717.735.7769 SOUTH CAROLINA PLANT P. O. Box 1006 200 Whetstone Rd. Swansea, SC 29160 Ph: 803.568.2100 Fax: 803.568.2121 TEXAS PLANT 600 Apache Trail Terrell, TX 75160 Ph: 972.524.5407 Fax: 972.524.5417 UTAH PLANT P. O. Box 907 1050 North Watery Lane Brigham City, UT 84302 Ph: 435.919.3100 Fax: 435.919.3101 www.nucorbuildingsystems.com/vr16 NBS10981