Evolution of Ozone Precursor Measuring and the PAMs Project from 1992 to Present



Similar documents
On-line Ozone Precursor Analyzers From the Leader in Thermal Desorption Technology

VALIDATION OF PAMS VOC DATA IN THE MID-ATLANTIC REGION

City of Fort Worth Follow-Up Survey Project Fort Worth, Texas Area April 19-23, 2010 (6/7/10)

PAMS Data Validation

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

PAMS DATA VALIDATION FOR THE NORTHEAST STATES

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

TSA of TCEQ Air Monitoring Program Austin, Texas September 7-28, 2010

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

BTU ANALYSIS USING A GAS CHROMATOGRAPH

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Pennsylvania Marcellus Shale Short- Term Ambient Air Sampling Project

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Transformer Oil Gas Analysis

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Chromatograph Maintenance and Troubleshooting Class # 5050

Series 2. Continuous monitoring of trace chemical vapours

Gas standards and measurements

H 3 C CH 2 CH 2 CH 2 CH 2 CH 3. Copyright 2012 Nelson Education Ltd. Chapter 1: Organic Compounds 1.1-1

Get the Right GC for Your Industry

HA University. Honeywell Fixed Gas Detection Calibration Handbook

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

HA University. Honeywell Fixed Gas Detection Calibration Handbook

Subotal - Community and Technical Colleges 267

Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

How To Run A Gas Plant

NGL RECOVERY PLANT: TREATER OPTIMIZATION FOR WATER AND MERCAPTAN REMOVAL

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

2015 Annual Monitoring Network Plan

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

District of Columbia 2016 Annual Ambient Air Monitoring Network Plan

Evaluation of Petroleum Hydrocarbon Methodologies Utilized by the Massachusetts DEP to Assess Potential Exposure in Vapor Intrusion Investigations

AMBIENT AIR QUALITY MONITORING SYSTEM. Air Quality Monitoring... Easier. Faster. Better.

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Split / Splitless Injection for Capillary GC

ß-CYCLODEXTRIN SYNONYMS

Tracer Detection Systems

APPENDIX B Emissions Calculations

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

SYNSPEC GC s ALPHA 115 and ALPHA 116

Gas Chromatography Liner Selection Guide

LSC-Montgomery. Institutions Attended, Fall 2009 Academic Students. LSC-Montgomery

Emission Testing February 2015 LMS Energy Pty Ltd - Jilliby Plant

Quality System Training Module 4 Data Validation and Usability

Diffusion and Fluid Flow

On-line Dissolved Gas Analysis

Outlet: Austin Business Journal (online) Date: December 17, 2014 Unique Visitors Per Month: 151,284 Link:

062010_tblAccreditedTCRLabs

Benzene and Natural Gas Production

MINERAL OIL (MEDIUM VISCOSITY)

VOCs Ambient Air Monitoring Report

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

The following table provides a comparison of Texas pass rates with the national average. Year % 9,290/11,

NITRIC OXIDE and NITROGEN DIOXIDE 6014

How To Test For Contamination In Large Volume Water

Bulletin 864A. Simulated Distillation of Petroleum Products by Packed Column and Capillary Column GC

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Purification of reaction mixtures using flash chromatography.

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

AMBIENT AIR MONITORING NETWORK PLAN FOR CALENDAR YEAR 2013

Fractional Distillation and Gas Chromatography

Texas Relocation Report

CHROMOCTANE O N LINE ANALYZER

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

23 The Thermal Conductivity Detector

Theory and Instrumentation of GC Introduction

Texas Relocation Report

HAZARDOUS AREA TECHNICAL GUIDE

AMBIENT AIR MONITORING NETWORK PLAN for CALENDAR YEAR 2016

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

METHOD 8020A AROMATIC VOLATILE ORGANICS BY GAS CHROMATOGRAPHY

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

Question Bank Organic Chemistry-I

Texas Reality Check Budget Data

Manual.

Transcription:

Evolution of Ozone Precursor Measuring and the PAMs Project from 1992 to Present Carol Meyer, Orsat, LLC Ozone Precursor Analyzer Lee Marotta, PerkinElmer

US Clean Air Act of 1992 US Mandated to the states in nonattainment of their ozone precursors that they monitor for four summer months a sample every hour. Essentially unattended operation: generators for combustion gases, controlled off-site to both collect data and to control system. A visit to the site every month to change carrier and fuel gases. An Ozone Precursor?

3 Current PAMS Sites

Current PAMS Sites Where I live YIKES! 4

System Configuration Continuous Ambient Air Sampling Sample Manifold Online Sampling Accessory Sample Calibrant Nafion drier Sample Pump Clarus 500 Gas Chromatograph Turbomatrix Thermal Deserbor Calibrant System 8/1 PerkinElmer INspiring INnovation Event November 15, 2012

Focusing 600mL of Sample (15mL/min for 40 min) Optional inlet split (off) Desorb flow xxxxxx Peltier-cooled focusing trap no liquid cryogen required to meet -35 o C Injection every hour Chromatography of previous sample is occurring as next sample is being collected onto the trap Carrier gas

Trap desorption in opposite direction of sampling Optional outlet split Analytical column FID heated trap Carrier gas in Analytical column Trap heats at 99 degrees / sec to efficiently desorb cold trap

Cold Trap Reduced diameter outlet reduces analyte dispersion or band broadening for narrower, focused peaks Trap is backflushed during desorption to recovery components Sorbent(s) Glass Wool Sample In/Out 0.7 mm xxxxxxxxx xxxxxxxxx xxxxxxxxx xxxxxxxxx Glass Tube Disks Packing Retaining Spring 2.8 mm

Air Toxics and Ozone Precursor Cold Trap graphitized carbon black sample in/out carbon molecular sieve

n-hexane C 2 hydrocarbons n-undecane Heart cut via Dean Switch All components eluting from methyl silicone column to determine heart cut time 30ppb canister standard at 15mL/min for 40min 600 ml sample cut 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

Volatiles onto PLOT split P1 trap P2 FID 1 50m x 0.22mm x 1µm methyl silicone column 50m x 0.32mm alumina/na 2 SO 4 PLOT column FID 2

C6 plus BP-1 split P1 trap P2 FID 1 50m x 0.22mm x 1µm methyl silicone column 50m x 0.32mm alumina/na 2 SO 4 PLOT column FID 2

Chromatography Alumina PLOT Chromatogram 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 Methyl Silicone Chromatogram 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 13

Target Analyte List PLOT Column BP1 Column Methane** 1,3-Butadiene n-hexane 2-Methylheptane n-decane Ethane 2-Methyl-1-Butene* Trans-2-Hexene* 3-Methylheptane 1,2,3-trimethylbenzene Ethylene Cyclopentene Cis-2-Hexene* N-Octane m-diethylbenzene* Propane Trans-2-Pentene Methylcyclopentane Ethyl Benzene p-diethylbenzene* Propylene 2-Methyl-2-Butene* 2,4-Dimethylpentane m + p-xylene n-undecane* Isobutane 1-Pentene Benzene Styrene α-pinene* n-butane Cis-2-Pentene Cyclohexane o-xylene β-pinene* Acetylene 2,2-Dimethylbutane 2-Methylhexane n-nonane Trans-2-Butene 2,3-Dimethylbutane* 2,3-Dimethylpentane Isopropyl Benzene 1-Butene 2-Methylpentane 3-Methylhexane n-propylbenzene Isobutene 3-Methylpentane* 2,2,4-Trimethylpentane m-ethyltoluene* Cis-2-Butene Isoprene n-heptane p-ethyltoluene* Cyclopentane 4-Methyl-1-Pentene* Methylcyclohexane 1,3,5- trimethylbenzene Isopentane 2-Methyl-1-Pentene* 2,3,4-Trimethylpentane o-ethyltoluene* n-pentane 1-Hexene* Toluene 1,2,4-trimethylbenzene * Components no longer reported by TCEQ ** not quantitatively trapped 8/10/2013

1994 C.O.A.S.T Project State of Texas Program Supported by Orsat

November 15, 2012 Several Requirements Capable of separating 56 hydrocarbon species each hour. Fully automated to allow automatic introduction of a daily check standard and system blank Daily Calibration Verification Standard (CVS) 15 components across boiling point range 3-point calibration curve Additional second source standards and retention time standards run weekly Automated file handling generating 144 data files each day/site Current Network of 35 sites reporting hourly data (31 public) Current Target list of 46 compounds Concentrations reported as ppbc 8/10/2013 PerkinElmer INspiring INnovation Event

Multi-point Calibration Propane and Benzene 8/1 PerkinElmer INspiring INnovation Event November 15, 2012

Air Monitoring Stations in Texas Dallas Hinton Region 4 - Dallas - Fort Worth Dallas PAMS 1999 Fort Worth Northwest Fort Worth PAMS 2003 Eagle Mountain Lake Fort Worth - Barnett Shale CATMN 2010 DISH Fort Worth - Barnett Shale CATMN 2010 Decatur Fort Worth - Barnett Shale CATMN 2010 Flower Mound Fort Worth - Barnett Shale CATMN 2010 Everman Fort Worth - Barnett Shale CATMN 2011 Kennedale Fort Worth - Barnett Shale CATMN 2012 Mansfield Fort Worth - Barnett Shale CATMN 2012 Rhome (TBD) Fort Worth - Barnett Shale CATMN 2012 OD Wyatt (TBD) Fort Worth - Barnett Shale CATMN 2012 UT Arlington Campus Fort Worth - Barnett Shale CATMN 2012 Dallas County (TBD) Fort Worth - Barnett Shale CATMN 2013 Johnson County (TBD) Fort Worth - Barnett Shale CATMN 2013 Tarrant County (TBD) Fort Worth - Barnett Shale CATMN 2013 El Paso Chamizal Region 46 - El Paso - Juarez El Paso PAMS 1997 El Paso Delta El Paso CATMN 2011 Region 7 - Odessa - Midland Odessa Hays Odessa CATMN 1999 Dallas/Ft. Worth: 15 Houston/Galveston/Brazoria: 12 Corpus Christi: 3 Beaumont/Pt. Arthur: 2 El Paso: 2 Odessa : 1 8/1 PerkinElmer INspiring INnovation Event November 15, 2012

Air Monitoring Stations in Texas, continue Nederland Region 10 - Beaumont - Port Arthur Beaumont-Pt. Arthur PAMS 2006 Beaumont Downtown Beaumont-Pt. Arthur PAMS 2006 Clinton Region 12 - Houston - Galveston - Brazoria Houston PAMS 1997 Deer Park Houston PAMS 1997 Channelview Houston PAMS 2001 HRM3 Houston EIMS 2003 Lynchburg Ferry Houston EIMS 2003 Wallisville Houston EIMS 2003 Texas City Texas City EIMS 2003 Lake Jackson Lake Jackson EIMS 2003 Danciger Danciger EIMS 2003 Cesar Chavez Houston CATMN 2004 Milby Park Houston CATMN 2005 HRM16 Houston Industry 2010 Region 14 - Corpus Christi - Victoria Oak Park Corpus Christi CATMN 2005 Solar Estates Corpus Christi CATMN 2005 CC Palm Corpus Christi CATMN 2010 PAMS 8 EIMS/Industry 7 CATMN 20 Total 35 11/ PerkinElmer INspiring INnovation Event November 15, 2012 EIMS Extended Industry Monitoring Site CATMN Community Air Toxics Monitoring Site

Automated file handling!!! generating 144 data files each day/site! Managing the data

TCEQ Web Based Data Reporting and Validation The key to handling large amounts of data consistently over long periods of time is Automation of Data Handling Consistent Application of Validation Rules Control of System Performance 8/ PerkinElmer INspiring INnovation Event November 15, 2012

What s different about Texas sampling? Year round sampling The use of two data bases for information LEADS Oracle

8/ November 15, 2012 TCEQ Web Based Data Reporting and Validation LEADS Database* Repository of hourly data collected directly from monitoring sites Updated with data which has been validated Database used for real-time Public Display of monitoring values Oracle Database Data is loaded daily by QC Validation staff System for the display and review of all quality control data Allows reload of reprocessed data Allows for flagging invalid data Allows calculation of Data Recovery Generation of EPA AQS files Review of operator and validator logs Other miscellaneous database management functions PerkinElmer INspiring INnovation Event * LEADS - Leading Environmental Analysis & Display software developed by IPS Meteostar

8/ November 15, 2012 TCEQ Web Based Data Reporting and Validation System for Display and Review of Quality Controls Display CVS, LCS, RTS and Blank Data Shows QC failures Shows Status Information Calibration Standards (LCS and CVS) with Dilution Factors Operator and Validator contact information Generation of Control Charts for LCS and CVS data Indicators for Audit Samples which have been run Shows Precision Each Sunday two CVS runs Day-to-day precision calculations Comparative results for CVS/LCS PerkinElmer INspiring INnovation Event

Will go through these quickly Example of reports from oracle The results!

TCEQ Web Based Data Reporting and Validation 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quicklook Daily Data Report Page 1 Collection Hour Sample Type File Name Reprocess Date Missing Targets TNMHC Total UnID d Wind Speed Wind Direction 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quicklook Daily Data Report Page 2 Ambient Data Flags PLOT Column 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quicklook Daily Data Report Page 3 Ambient Data Flags BP-1 Column 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Quality Control Navigation 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Date Range and Site Selection 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Weekly RTS 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Weekly LCS 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Graph Weekly LCS 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Daily CVS 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Graph Daily CVS 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Quality Control Reports Daily Blanks 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Site Operator Log Reports 8/ PerkinElmer INspiring INnovation Event November 15, 2012

Summary Automated Online Sampling - for sample and calibrant Remote Access Control Overlapping - Analytical Run Time Low Volume Cold Trap Auto Log - data integrity Automatic Leak Check per Injection Focusing and Chromatography without liquid cryogen Get info on web when you want it Total Solution

??? Ozone Precursor Analyzer Contact Carol Information Meyer, Orsat, LLC Lee Marotta, PerkinElmer Heidi.grecsek@perkinelmer.com lee.marotta@perkinelmer.com