Backup Fuel Oil System Decommissioning & Restoration Plan



Similar documents
A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

Boiler and Burner Cleaning and Servicing Specifications

Evaluate, Clean, and Tune Guidance

Oil and Coolant Circulating Heating System. Model - OCSM

Factory owners must ensure the boiler is:

Boiler & Pressure Vessel Inspection discrepancies and failures

Diesel Engine Driven Generators Page 1 of 6

INSPECTION AND TESTING OF EMERGENCY GENERATORS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Mechanical Engineering Technician- Plant Technician

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

Attachment J-C18.1. HVAC Work Instructions

Dealer Sales & Service Guide

Energy Efficient Operations and Maintenance Strategies for Boilers

Routine and Emergency Boiler Operation

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

WATER SUPPLY SYSTEMS FOR 150/5220-4B AAS-100 AIRCRAFT FIRE AND RESCUE PROTECTION

Trouble Shooting. Pump

Boiler Preparation, Start-Up and Shutdown

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Company Name: City, State, Zip Code: Annual Report Summary

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement.

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Action Plan Template HVAC Page 1

Air Conditioner Water Heater Model ACWH18

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

How To Clean Up A Reactor Water Cleanup

Waste Oil Collection / Storage

Fossil fuel heating equipment

GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90

ElastoFlake & ElastoTec

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

INTEC Engineering GmbH Heating Solutions for the Marine Industry

CARING FOR YOUR WATER HEATER

Guidelines for Preparing for a Temporary Steam Plant

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN

Guide Specification SECTION COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY

Technical Specification. Generating Set with Waukesha engine burning natural gas

SIOUX HYBRID WATER HEATER

Standard Hydraulic Piping Flushing Procedure

Electric & Gas Water Heaters

Munchkin Heat Exchanger Maintenance

Advanced_O&M_Task_List_Example_Tool_06_02_16: O&M Example

SWIMMING POOL HEAT PUMP

Building Commissioning

A cure for water damage in real estate

Maintaining Fire Protection Systems

NFPA31FuelOilPiping 1 Revised

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Preventive Maintenance. Learning Objectives: Howdy! Learning Objectives Cont:

Fire Pump Plan Review March 2010

Roles and Responsibilities of Plant Commissioning, Hydrocarbon Introduction and Acceptance Test Run

Hydraulic Trouble Shooting

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

TECHNICAL ADVISORY BULLETIN

Peace of Mind: Savings: Priority Dispatching:

PLP - TERMS AND CONDITIONS

Commercial Gas Water Heaters

North Dakota State Fire and Tornado Fund Providing affordable property insurance coverage for the state and its political subdivisions since 1919.

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Medical Air Systems: Scroll

Finding and Fixing Leaks

What to Expect From the Examination. How to Study the Plumbing Codes

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

SB96-11B FAA APPROVED Supersedes SB96-11A, SB96-11, M84-16

INDEX GENERAL

Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007

Spill Control Prevention Plan (SCPP)

Tankless Water Heater

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

California Solar Initiative (CSI) Thermal Program Metering Installation Guide

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Hazards associated with the gas system and how to mitigate them

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Tips for a Successful Diesel Retrofit Project

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Annual Service Agreement

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Plan Number A Cross Beam Dr. Charlotte, NC Simplified Service Plan. Air Conditioning.

Winnipeg Fire Department Fire Prevention Branch

I. Introduction. 10 minutes

Transcription:

Backup Fuel Oil System Page 1 of 19

Overview of Physical Fuel Oil System and Decommissioning Steps The fuel oil system at Milford Power consists of a number of subsystems. These include the following: 1.) Fuel Oil Unloading 2.) Fuel Oil Storage Tank 3.) Fuel Oil Conditioning and Forwarding Pumps 4.) Fuel Oil Pumps 5.) NO x Water System and Pumps 6.) Fuel Oil Meters 7.) Fuel Oil Combustion System and Controls 8.) Enclosures A summary of each subsystem and the required steps for decommissioning and maintenance required during the lay-up phase is outlined below. All decommissioning preventive maintenance (PM) items will be entered into the facility Computerized Maintenance Management System (CMMS) database. The CMMS will automatically print out each PM item as it becomes due. Technicians will complete the PM item and update the CMMS system as needed. There are a number of standard PM items performed on the various pieces of equipment within the system, when the system is decommissioned. The various pumps in the system will be rotated and lubricated per original equipment manufacturer ( OEM ) recommendations. Motors will be electrically tested at recommended intervals and motor heaters will remain in service to preserve the condition of the motors. Instrumentation will be Page 2 of 19

calibrated. The fuel oil and the NOx water piping systems within the gas turbine building will be periodically drained to ensure no water accumulations that may corrode piping. This plan first describes each subsystem of the fuel oil system and its decommissioning and layup. The plan then describes the activities to restore the fuel oil system if it becomes necessary. 1.) Fuel Oil Unloading Subsystem The fuel oil unloading subsystem consists of the pumps required to off-load the fuel oil from the delivery trucks and the associated piping to move the oil into the fuel oil storage tank. Pumps and piping will be emptied and drained and then stored in a dry condition, with the pumps being isolated electrically. Contactors and breakers will be racked out. Page 3 of 19

2.) Fuel Oil Storage Tank The fuel oil storage subsystem consists of a 1.2 million gallon steel tank. The fuel oil tank will be drained of all fuel and water, if any. The tank will be inspected, cleaned, and placed in long-term storage. Periodic inspections will be completed in accordance with accepted industry standards. Page 4 of 19

3.) Fuel Oil Conditioning and Forwarding Pumps Fuel oil conditioning requires the fuel oil to be a specific temperature to allow for the proper operation of the control valves that regulate the flow of fuel oil into the gas turbine. This is accomplished with the fuel oil heaters. In addition to the fuel oil heaters, a series of transfer pumps move the fuel oil to the pumps that direct the fuel oil into the gas turbine engine. Page 5 of 19

The fuel oil heaters will be emptied and stored in a dry condition and isolated electrically. Recommended OEM layup instructions will be followed. Page 6 of 19

Pumps and piping will be emptied and drained and then stored in a dry condition, with the pumps being isolated electrically. Contactors and breakers will be racked out. Motor heaters will remain in service. 4.) Fuel Oil Pumps The fuel oil is pumped from the transfer pumps to the fuel oil skid for each gas turbine, located just outside each of the gas turbine buildings. Located inside the skid is the fuel oil pump, which pumps the fuel oil directly into the gas turbine. Page 7 of 19

Pumps and piping will be emptied and drained and then stored in a dry condition, with the pumps being isolated electrically. Contactors and breakers will be racked out. Page 8 of 19

5.) NOx Water System and Pumps To control NOx emissions while on fuel oil, the gas turbine requires the injection of demineralized water with the fuel oil. This fuel oil/water emulsion is injected through the unit s burners to ignite inside the gas turbine. The demineralized water is stored in a 1.2 million gallon tank sized especially for fuel oil operation. The water is sent to an enclosure similar to the fuel oil pump enclosure where the water is pumped to the required pressure needed to mix with the fuel oil and enter the gas turbine. Pumps and piping will be emptied and drained and then stored in a dry condition, with the pumps being isolated electrically. Contactors and breakers will be racked out. Page 9 of 19

NOx Water Skid with Fuel Oil Forwarding Skid to the Right 6.) Fuel Oil Meters The fuel oil flow is metered for both turbine operations and emissions reporting required under the facility s air permit. The fuel oil flow meters will be removed and stored in a suitable environment on-site to maintain permit compliance. All other instrumentation will be stored as per the OEM s recommendations. Page 10 of 19

7.) Fuel Oil Combustion System and Controls The fuel oil and demineralized water is combined at the sector valves on the gas turbine. The mixture then enters the gas turbine where the control system ensures the fuel is combusted. To meet permit and operational requirements, a series of trip shut-off valves (to protect the gas turbine engine) and control valves are required. Page 11 of 19

Page 12 of 19

Page 13 of 19

The trip shut-off valves and control valves associated with fuel oil combustion will be disassembled, preserved, and reassembled as per OEM recommendations. Sector and purge valves and all manual valves will be exercised routinely as part of the long term layup maintenance program. Valves and valve actuators will continue to be serviced as per OEM requirements. The emulsion piping, which carries the fuel oil/water mixture to the burners, will be removed and placed in storage on site. The emulsion piping is the only significant hardware that will be physically removed from the gas turbine engine. The emulsion piping on Unit 1 has shown cracking, due to stress corrosion cracking and has been removed from the unit. Stress corrosion cracking occurs when certain chemicals, such as chlorides, attacks the grain structure of the material while under stress. The emulsion piping is under stress Page 14 of 19

within the turbine enclosure because of the associated heat and stress from vibration from the gas turbine engine. The set of emulsion pipes on Unit 2 has been tested and has not exhibited any evidence of stress corrosion cracking at this point. With the problem shown in Unit 1, there may be a possibility the emulsion pipes from Unit 2 could exhibit stress corrosion cracking in the future. The logic in the software of the Distributed Control System related to the combustion of fuel oil will be deactivated under the supervision of the OEM. Milford Power has already discussed the required steps and work needed to decommission the controls system with the OEM. 8.) Enclosures As mentioned previously, there are a number of enclosures associated with the fuel oil system. These include the fuel oil forwarding building (heaters and transfer pumps), fuel oil pump skid, NOx water pump skid, and the foam fire protection enclosure for the fuel oil tank. Page 15 of 19

Foam Fire Protection Enclosure A normal environment will be maintained in the enclosures. Each enclosure will be inspected periodically and temperatures will be monitored continuously via wireless temperature probes. Recommissioning In returning the decommissioned fuel oil system to operational status, a number of concurrent steps will need to be performed. The work can be summarized in three phases. These phases are Pre-Cold Commissioning Work, Cold Commissioning, and Hot Commissioning. Overall, recommissioning could take four to six months as a number of the steps outlined below are dependent on third-party actions, which cannot be controlled by Milford Power. Page 16 of 19

Pre-Cold Commissioning Work (Approximately Four to Twelve Weeks) - Equipment that has been removed, such as the emulsion piping, will be reinstalled. This reinstallation may require an outage of the gas turbine engine to perform the work. As noted previously, the emulsion piping on Unit 1 has been removed and the emulsion piping on Unit 2 may require replacement. Upon initiation of the recommissioning work, Milford Power will order replacement piping from the OEM. - Installation of temporary instrumentation (used to measure cooling air flow) to perform Hot Commissioning Work. This installation will require a two to three day outage and will coincide with installation of emulsion piping. - The software in the Distributed Control System will be restored to include all logic associated with the combustion of fuel oil. This restoration will require OEM support and could be dependent on availability of the OEM s personnel. - The fuel oil flow meters will be sent out for calibration, if necessary, and reinstalled. - Arrangements and testing associated with obtaining fuel oil will be completed. This activity requires the isolation of a dedicated tank to ensure the fuel oil meets the OEM s specifications. - All in-service date related testing will be completed on the fuel oil tank prior to filling the tank. The fuel tank vacuum breaker/vent valve will be inspected and tested. - The fuel oil tank foam system will be made operational and tested. Page 17 of 19

- Filling of the fuel oil tank, which may be dependent on availability of truck deliveries by the fuel oil vendor. - An internal inspection and an alignment check of the large pumps (NOx water & Fuel Oil) will be conducted. - The contactor, breakers, and instrumentation in all systems to be recommissioned will be inspected and calibrated as appropriate. - Pump motor checks will be completed and the pumps will be bump tested. - System integrity will be verified for all systems being restored and then the systems will be filled, flushed, and tested as required. - Arrangements will be made for stack testing on fuel oil to be performed during the hot commissioning. The stack testing company and the DEP will be notified. Cold Commissioning (One Week to Two Weeks) Cold Commissioning includes the inspection of all fuel oil combustion related systems and equipment. The equipment will be inspected and functionally tested by OEM engineers and technicians prior to gas turbine fuel oil combustion. The system will be pressure tested to ensure that there are no fuel oil leaks, that all control valves, and instrumentation are working properly, and that all input and output signals from the control system are manipulating equipment as expected. The work is performed almost entirely by the turbine OEM engineers and technicians, with limited support from site personnel. The timing of the work would be dependent on the availability of the OEM engineers and technicians. The leak check portion of the work would require the gas turbine engine to be offline and cold. This would require an outage of 2 to 3 days. Page 18 of 19

Hot Commissioning (One Week) Hot Commissioning is the actual test firing of the gas turbine engine on fuel oil. This work is performed entirely by OEM engineers and technicians and timing would be entirely dependent on their availability. Hot Commissioning work requires a number of adjustments to the combustion system to balance combustion stability and performance, along with ensuring that the unit operates within permitted emission limits. To perform the Hot Commissioning, the unit is operated at increasing levels of output to tune the combustion system. During this time, the unit is not available for dispatch to the New England ISO and is run in a self-scheduled mode. The testing may be delayed or extended if the New England ISO is not able to accept the power from the tested unit because of market conditions. The turbine OEM s expected duration and consumption of fuel oil are approximately 30 hours of operation and 300,000 gallons of fuel oil if there are no significant problems, delays, and/or unit trips with the fuel oil testing. At the end of the Hot Commissioning, another 2 to 3 day outage is necessary to remove the instrumentation needed for the work. Page 19 of 19