SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Similar documents
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Internet Office 500VA Tower Standby 120V UPS with USB port

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Model #: SMART2200CRMXL

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

BC Pro UPS System Standby UPS System

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Internet Office UPS System Standby UPS for PCs, workstations and more

Uninterruptible Power Supply

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Tough Decision: On-Line or Line-Interactive UPS?

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course Tripp Lite.

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

MAJORSINE Power Inverter

LAP ENERGIA PARA DATACENTERS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

PowerGem Pro Uninterruptible Power Supply

Installation and Operation Back-UPS 1250, 1300, 1500

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

VISION UPS UPS PRODUCT CATALOGUE

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Back-UPS Pro 1300/1500 Installation and Operation

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Technical Data. back-up time in minutes 100% load % load

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Online UPS. PowerWalker VFI 1000R/1U

R5000 Uninterruptible Power System (UPS) Overview

R5000 Uninterruptible Power System (UPS) Overview

Tripp Lite PowerAlert

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

EKOS Cart. Instructions for Use

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Product Snapshot. Powerware 5125 Family Uninterruptible Power System. Introducing the expanded Powerware 5125 family of UPSs.

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

I STAR COMPUTER CO., LTD

Smart-UPS On-Line 230 V

Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

User s Manual AURORA 1.2K/2.2K

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Dell Smart-UPS 1,500 3,000 VA

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

How To Use A Power Supply Unit (Upu)

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

User Manual 1K/2K/3K Online UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

DATA CENTER SOLUTIONS

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

750VA/1000VA/1500VA 100/120/230VAC 2U

Assembled in Florida, USA.

UNINTERRUPTIBLE POWER SUPPLY (UPS)

USER MANUAL Online UPS 1K/2K/3K

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

IBM 11000VA LCD 5U Rack Uninterruptible Power Supply IBM System x at-a-glance guide

Line Interactive UPS

Cisco Nexus 7000 Series Power Supply Modules

NeTYS PR VA

USER MANUAL Online UPS 1K/2K/3K Rack

Cisco Redundant Power System 2300

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Transcription:

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMX750SLT Highlights 750VA line interactive tower UPS; Sine wave output 220/230/240V nominal output during brownouts and overvoltages USB, RS232 and optional SNMP/Web card are available for simultaneous use Front panel status LEDs with load level and battery capacity display C14 input; 6 C13 outlets; Includes 2 C13 to C14 cables Package Includes SMX750SLT UPS System PowerAlert Software CD-ROM USB and serial cabling Description User manual with warranty Tripp Lite's SMX750SLT intelligent, line-interactive sine wave UPS system protects servers, networking information accessories and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Large internal batteries offer 15 minutes half load runtime and 5 minutes full load runtime. 750VA/500 watt power handling capability and full-time sine wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic applications. Includes 6 protected C13 output receptacles total. Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Single line Tel/DSL and network Ethernet line surge suppression. Built-in audible alarm and 9 LEDs offer status notification for line power, battery power, battery charge level, load level, plus AVR boost and trim operational status information. Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges. Attractive, all-black tower housing. Features SMX750SLT line-interactive UPS offers battery derived sine wave AC output during power outages, voltage regulation during brownouts and overvoltages, plus network-grade AC surge suppression 750VA/500 watt power handling capability with full-time sine wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic devices Large internal batteries offer runtimes of 15 minutes at half load (325VA/250 watts) and 5 minutes at full load (750VA/500 watts) Automatic Voltage Regulation (AVR) circuits maintain user-selectable 220, 230 or 240V nominal output over an input voltage range of 151 to 290 Includes 6 C13 output receptacles IEC320-C14 input connection accepts a variety of detachable cordsets Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software Supports Tripp Lite's WatchDog software application (requires optional WATCHDOGSW) 9 LEDs offer continuous status information of UPS operating parameters and site power quality Hot-swappable batteries allow on-site battery replacement without powering off connected equipment 1 / 5

Hot-swappable batteries allow on-site battery replacement without powering off connected equipment Single line Tel/DSL and network Ethernet line surge suppression Specifications General Info RoHS Y OUTPUT Output Volt Amp Capacity (VA) 750 Output Watt Capacity (Watts) 500 Power Factor 0.7 Nominal Output Voltage(s) Supported Nominal Voltage Details Frequency Compatibility Output Voltage Regulation (Line Mode) Output Voltage Regulation (Battery Mode) Output Receptacles Included Output Power Cables Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 220V; 230V; 240V 230V default (voltage selection via back panel switches) 50 / 60 Hz -11%, +6% +/- 5% (6) C13 Includes 2 C13 to C14 output power cables Sine wave Pure Sine wave INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported UPS Input Connection Type UPS Input Connection Description Input Phase 3.6A (220V), 3.5A (230V), 3.4A (240V) 220V AC; 230V AC; 240V AC C14 inlet IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) 5 min. (500w) 15 min. (250w) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 4 hours to 90% (typical, full load discharge) 2 / 5

Internal UPS Replacement Battery Cartridge Battery Access Battery Replacement Description RBC24-SLT Battery access door Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction Severe Undervoltage Correction Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 290V Voltage reduction of 12% applies when input is 232-266 (220V), 244-278 (230V), 254-290 (240V) Voltage boost of 15% applies when input is 175-198 (220V), 182-206 (230V), 190-216 (240V) Voltage boost of 30% applies when input is 151-174 (220V), 158-181 (230V), 166-190 (240V) USER INTERFACE, ALERTS & CONTROLS Switches Alarm Cancel Operation Audible Alarm LED Indicators 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection Power-fail alarm can be silenced using alarm-cancel switch Audible alarm indicates power failure and overload conditions 9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 504 UPS AC Suppression Response Time UPS Dataline Suppression EMI / RFI AC Noise Suppression Instantaneous 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet Yes PHYSICAL Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) Tower 10.25 x 6.75 x 13.25 26 x 17.1 x 33.7 UPS Power Module Weight (lbs.) 34.1 UPS Power Module Weight (kg) 15.5 UPS Shipping Dimensions (hwd / in.) 14 x 9.75 x 18.5 UPS Shipping Dimensions (hwd / cm) 35.6 x 24.8 x 47 Shipping Weight (lbs.) 38.6 Shipping Weight (kg) 17.5 Cooling Method Fan 3 / 5

UPS Housing Material Steel ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 73 Battery Mode BTU / Hr. (Full Load) 349 AC Mode Efficiency Rating (100% Load) Audible Noise 96% Audible Noise < 50 dba at Front Side 1 Meter COMMUNICATIONS Communications Interface Network Monitoring Port Description PowerAlert Software Communications Cable WatchDog Compatibility USB (HID enabled); DB9 Serial; Slot for SNMP/Web interface Supports detailed monitoring of UPS and site power conditions Included USB and DB9 cabling included Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) 4-8 milliseconds 151 (220V), 158 (230V), 166 (240V) 266V (220V), 278V (230V) or 290V (240V) SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Green Energy-Saving Features Cold-start operation supported Hot swappable batteries Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications UPS Certification Details CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia) EN62040-1, EN62040-2 WARRANTY Product Warranty Period (International) 4 / 5

Product Warranty Period (Mexico) Product Warranty Period (Puerto Rico) 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 5 / 5