SIP Device Compatibility Report



Similar documents
NetComm V90 VoIP Phone Quick Start Guide Draft Release 0.1

Note: these functions are available if service provider supports them.

Communication Manager configuration for BLU-103

DPH-140S SIP Phone Quick User Guide

P160S SIP Phone Quick User Guide

Application Note. IP8000 Conference Phone Configuration Guide. Table of Contents. Overview. Requirements. ST October 25, 2007

GW400 VoIP Gateway. User s Guide

CyberData VoIP V2 Speaker with VoIP Clock Kit Configuration Guide for OmniPCX Enterprise

How to Configure the NEC SV8100 for use with Integra Telecom SIP Solutions

Installation of the On Site Server (OSS)

Application Notes for snom 3x0 VoIP Phones with Avaya IP Office Issue 1.0

Provisioning and configuring the SIP Spider

SIP Trunking with Allworx. Configuration Guide for Matrix SETU VoIP Gateways

Optimum Business SIP Trunk Set-up Guide

SIP Trunking Service Configuration Guide for Time Warner Cable Business Class

RingCentral Office. Configure Grandstream phones with RingCentral. To contact RingCentral, please visit or call

Configuration Notes 290

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: Password: 1234

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Cisco Call Manager Express Version 8.5

Application Notes for Revolabs FLX UC 1000 with Avaya IP Office - Issue 0.1

Configuring the Cisco SPA9000 Voice System with the Cyberdata VoIP Intercom for Door Bell Applications

Integrating a Hitachi IP5000 Wireless IP Phone

IP PBX. SD Card Slot. FXO Ports. PBX WAN port. FXO Ports LED, RED means online

SIP Trunking Service Configuration Guide for MegaPath

Configuring the Synapse SB67070 SIP Gateway from AT&T for Clearfly SIP Trunking. January 2013

RingCentral Office. Configure Aastra phones with RingCentral

Technical Configuration Notes

Nokia E65 Internet calls

SV9100 SIP Trunking Service Configuration Guide for Time Warner Cable Business Class

SIP Trunking Service Configuration Guide for Skype

Voice Over IP Manual

Sipura SPA-3102 Simplified Users Guide Version 1.1a In Progress :)

Smart Telephone System

Chapter 1 Configuring Basic Connectivity

P-2602HWNLI. Quick Start Guide g Wireless ADSL2+ 4-port VoIP IAD. Version /2007 Edition 2

Configuring the Avaya B179 SIP Conference Phone with Avaya Aura Communication Manager and Avaya Aura Session Manager Issue 1.0

SIP Trunking Service Configuration Guide for Broadvox Fusion

How To Configure A Linksys Pap2T With Virtualbpx On A Cell Phone On A Pc Or Ipad Or Ipa (For Ipa) On A Ipa Or Ip2T On A Sim Sim (For Sim Sims

DECT Gigaset N510 IP PRO

Abstract. Avaya Solution & Interoperability Test Lab

Cisco SPA901 1-Line IP Phone Cisco Small Business IP Phone

Algo 8180 Integration with Zultys

Cisco Unified Communications Manager SIP Trunk Configuration Guide

Application Notes for Configuring Yealink T-22 SIP Phones to interoperate with Avaya IP Office - Issue 1.0

Step 1: Checking Computer Network Settings:

Voxitas SIP Trunk Setup

2100 Series VoIP Phone

Tables of Contents. Getting Started

3.5 EXTERNAL NETWORK HDD. User s Manual

Installation and setup guide V 1.0

Configuring Shared Line Appearances over Analog Trunks

Configuring the Dolby Conference Phone with Cisco Unified Communications Manager

SIP Trunking Service Configuration Guide for PAETEC (Broadsoft Platform)

Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out

Integrating Citrix EasyCall Gateway with SwyxWare

VOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide

DSX. ATC SIP Trunk Setup. April 22, 2011 Issue NEC Corporation of America 4 Forest Parkway, Shelton, CT 06484

ShorePhone IP 8000 Conference Phone Configuration Guide

Voice over IP Manual

Quick Installation Guide. Overview. PLANET VIP-156/VIP-156PE/VIP-158 Quick Installation Guide

Deploying Polycom SoundStation IP Conference Phones with Cisco Unified Communications Manager (CUCM)

Link Gate SIP. (Firmware version 1.20)

Quick Installation Guide

MyPBX U100 & U200 Installation Guide

P-2602HWNLI. Quick Start Guide g Wireless ADSL2+ 4-port VoIP IAD. Version /2006 Edition 1

Configuring PPP And SIP

NEC DSX-40 IP-PBX. Optimum Business Trunking and the NEC DSX-40 PBX Configuration Guide

Application Notes for Algo 8028 SIP Door Phone with Avaya IP Office - Issue 1.0

Business VoIP Solution Training 04/2009

Certificate of Compatibility

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz)

Broadvox SIP Trunk Setup

SIP Trunk Recording Configuration For CUCM 6.x Version 8.0

JetWave SIP Trunk Setup

MITEL SIP CoE. Technical. Configuration Notes. Configure the Mitel 3300 MCD 4.1 for use with Paetec Broadworks Softswitch. SIP CoE

3CX PBX v12.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the 3CX PBX v12.5

KX-UT113/KX-UT123 KX-UT133/KX-UT136 KX-UT248

LINKSYS / SIPURA SPA-1xxx/2xxx/3xxx CONFIGURATION GUIDE Minimum Requirements

Configuring CyberData VoIP Ceiling Speakers

MAX CRM v 1.2 User Guide

Analog Telephone Adapter Network settings via Keypad commands:

SL 1100 Quick Start Help Guide Table of Contents:

TECHNICAL SUPPORT NOTE. 3-Way Call Conferencing with Broadsoft - TA900 Series

Configuring CyberData Devices for Intermedia Hosted PBX

Application Notes for Configuring Cablevision Optimum Voice SIP Trunking with Avaya IP Office - Issue 1.1

Application Notes for Spectralink 84-Series Wireless Telephones and Avaya IP Office Issue 1.0

Voice Gateway with Router

Welcome. Unleash Your Phone

Asterisk 10 Digium Partner Certification Interoperability Report ESCENE SayHi IP Phone

THINKTEL COMMUNICATIONS CUDATEL PHONE SYSTEM 270. High Availability and SIP-TRUNK Configuration

UCM61xx Configuration

IMX Mobile Proxy Administration

MITEL SIP CoE. Technical. Configuration Note. Configure MCD for use with Intelepeer Service provider SIP Trunking. SIP CoE

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

DSX. DSX SIP Setup. April 22, 2011 Issue NEC Corporation of America 4 Forest Parkway, Shelton, CT 06484

PA168X SIP Phone Http Setup Guide

Quick Installation and Configuration Guide OX10

Using Cisco UC320W with Windows Small Business Server

Avaya IP Office SIP Configuration Guide

Transcription:

SIP Device Compatibility Report Konftel 300IP SV9100 NEC Enterprise Solutions has performed Interoperability Testing with the Device and Switch(es) listed above on the date specified. Please always refer to the appropriate SIP Extension Compatibility Report Index and the latest edition of a specific Compatibility Report on BusinessNet before considering connection. If a Device is no longer mentioned in the Index then the Compatibility Report has been withdrawn and connection will no longer be supported by NEC Enterprise Solutions. Test Completion Date: Monday, 15 June 2015 Manufacturer: Konftel Model: 300IP Firmware Version: 2.2.4 NEC Platform Tested: Software Version: Test Plan Version: SV9100 V2.00.60 1.0 Please refer to the following page(s) for further Information and Configuration Notes.

Description of SIP Extension The Konftel 300IP is a flexible SIP-based conference phone, perfect for companies that use IP voice services. Recommended Software Versions SV9100: CPU V2.00.60 System Configuration An unused extension number should be assigned to an unallocated port on the telephone system. (Refer to PRG11-02 / Wizards > Advanced Items > VoIP > SIP Extensions > SIP Terminal Settings). The SIP device will register to this extension number. If authentication is required, a password should be entered in PRG15-05-16 / Wizards > Advanced Items > VoIP > SIP Extensions > SIP Terminal Settings. Authentication is enabled by default in PRG10-33-02 / Wizards > Advanced Items > VoIP > SIP Extensions > SIP Device Setup. CODEC settings can be changed in PRG84-19 / Wizards > Advanced Items > VoIP > SIP Extensions > SIP Extension Codec Settings. Further information on all the commands listed above for the systems is available in the Online Help in PCPro. SIP Extension Configuration The Konftel 300IP is configured via a web-based interface. The device can be mains powered or PoE. The most common method of configuration is to use DHCP to issue the device with an IP address, and then use a Web Browser to configure the advanced settings. It is possible to confirm the network configuration of the device through the on screen menu. Page 2 of 7

Web-based configuration Login Log in to the web configuration menu. Use the profile Admin and the default password 1234. SIP Settings Under Settings > SIP you can configure the connection account used to communicate with the NEC system. An example below is using extension number 235 and the default SIP extension port UDP:5070 and an IPL address of 192.168.88.150. Page 3 of 7

Network Configure here if a static IP address or VLAN tag is required for the customers LAN. Media Configure here the supported codecs for the device. It is recommended at G.722 is configured for highest quality audio. G.711Ulaw is not supported and should be disabled. DTMF Signalling should be set to SIP Info. Page 4 of 7

Time and Regional Settings Ensure that the correct time zone is configured and daylight savings if required. Page 5 of 7

Known Limitations G.723, G.726 and ilbc are not supported by this device. 30ms VSI is the only supported sample size The device does not support MWI (Message Waiting Indicator). Further Support Actual product support must be obtained from the supplier or manufacturer of the third party device. The manufacturer s website is currently http://www.konftel.com Compatibility Overview Registration - No Authentication Successful Registration Maintain Registration Registration Refresh Registration Failure De-registration Registration with Authentication Successful Registration Maintain Registration Registration Refresh Registration Failure De-registration Registration Failure 480 Call to PSTN/ISDN Call internal to Keytelephone Incoming call from PSTN/ISDN Incoming call from Keytelephone CODECs Disabling and Reordering Disabled CODEC outgoing call Disabled CODEC incoming call CODEC order outgoing call CODEC order incoming call Sending digits during ringing Sending digits during ringing Sending digits during conversation Sending digits during conversation /Incompatible Not Not Page 6 of 7

Sending digits during ringing (DTMF Relay) Sending digits during ringing Sending digits during conversation (DTMF Relay) Sending digits during conversation Flash hook/recall Hold & retrieve Consult Transfer (Flash hook/recall) Hold & Transfer (REFER) Blind Transfer (Flash hook/recall) Hold & Blind Transfer (REFER) Unexpected SIP extension termination (Idle) Unexpected SIP extension termination (In conversation) Network Issues Disconnect the Ethernet cable X3 (During idle) Disconnect the Ethernet cable X3 (During conversation) Disconnect the Ethernet cable X4 (During idle) Disconnect the Ethernet cable X4 (During conversation) Disconnect the Ethernet cable X2 (RTP stream) (During conversation) (SIP Info) (SIP Info) CODEC Overview See section 7 for detailed test results of CODEC compatibility. G.711 G.729 G.722 Document History Version Date Description 1.0 16 th June 2015 Initial Release (Field Trial) TO THE EXTENT NOT PROHIBITED BY LAW, IN NO EVENT SHALL NEC ENTERPRISE SOLUTIONS BE LIABLE FOR PERSONAL INJURY OR ANY INCIDENTAL, SPECIAL, DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, LOSS OF DATA, BUSINESS INTERRUPTION OR ANY OTHER COMMERCIAL DAMAGES OR LOSSES ARISING OUT OF OR RELATED TO YOUR USE OF SIP COMPATIBILTY REPORTS, HOWEVER CAUSED REGARDLESS OF THE THEORY OF LIABILITY (CONTRACT, TORT OR OTHERWISE) AND EVEN IF NEC ENTERPRISE SOLUTIONS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, DUE TO THE POSSIBILTY OF PROVIDERS MAKING SYSTEM CHANGES WHICH PROCEED THE COMPATIBILITY TESTING DETAILED IN THIS REPORT. IN NO EVENT SHALL NEC ENTERPRISE SOLUTIONS TOTAL LIABILITY TO YOU FOR ALL DAMAGES (OTHER THAN AS MAY BE REQUIRED BY APPLICABLE LAW IN CASES INVOLVING PERSONAL INJURY) EXCEED THE AMOUNT OF SEVENTY FIVE POUNDS ( 75). THE FOREGOING LIMITATIONS WILL APPLY EVEN IF THE ABOVE STATED REMEDY FAILS OF ITS ESSENTIAL PURPOSE. Page 7 of 7