DT151F and DT152F Thermodynamic Steam Traps Installation and Maintenance Instructions



Similar documents
BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

PBX Series Quick Fit Connector Bimetallic Steam Traps

FT43, FT44, FT46 and FT47 Ball Float Steam Traps

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

LP30 High Integrity, Self-monitoring Low Level Alarm Probe

SV615 Safety Valve. 1. Safety information. 2. Product information. 3. Supply. 4. Handling. 5. Before fitting the valve. 6.

VAD Variable Area Desuperheaters

VAD. Variable Area Desuperheaters

Float and Thermostatic Traps Series H, C and X

WD600 STEAM TRAPS. Thermodynamic Steam Trap

MFP14, MFP14S and MFP14SS Automatic Pumps

CSF16 and CSF16T Stainless Steel Steam Filters

Colima Visco and Colima Viscorol Magnetic Level Indicators

Type 25P & 25PA Pressure Reducing Valves

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Blowdown vessels Meeting the requirements of HSE PM60

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

INSTALLATION, OPERATION & MAINTENANCE MANUAL

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

TYPE E Main Valve Sizes 3 /8 through 12

Steam System Best Practices Condensate System Piping

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Hydraulic control unit series

James M. Pleasants Company

IMPORTANT SAFETY NOTICE

Direct steam injection humidifiers

Factory owners must ensure the boiler is:

TRI CLAMP PRESSURE REGULATORS

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Maintenance and Service Instruction

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V

This instruction is valid for all ACD pump models shown on page 2

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Backflush filter R8-30W

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Maintenance and Instruction Manual. December 2011 Rev. 01 Page 1 of 12

Diaphragm Control Valves FLUXOTROL Series I and Series 25 Installation and Maintenance Instructions

TECHNICAL DATA. Dry 122a. November 12, 2013

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Operating and installation instructions

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

EN20 EN50. Double-stage modular decompression unit for oenological application. FEATURES Dual inlet and single outlet decompression unit.

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Stainless Steel Single and Dual Circulation Kits

API Flanged Safety Relief Valves Series 526 CATALOG

Produktkatalog (GB/IT)

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

SunMaxx Solar Filling Station Operating Instructions

INFORMAZIONI GENERALI / GENERAL INFORMATION

Desuperheater Online Program Sizing Guidance

QLM and QLD Series Three-port Control Valves

Morrison Bros. Co. General Product Specifications

Air Eliminators and Combination Air Eliminators Strainers

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

PRESSURE REDUCING VALVES

EP5 and ISP5 Series Electropneumatic Positioners

How To Use An Akua Magnetic Lime Scale Preventing Device

The Axial Flow Valve. Class 300/ SERIES

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Grey cast iron SG iron Forged steel/ Cast steel Stainless steel Fig. 631 Page 2. High temperature steel Fig. 631 / Fig. 632 Page 8

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Flamco. Flexcon M. Installation and operating instructions Flamco

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

Toroidal Conductivity Sensor

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

V47 Series Temperature Actuated Modulating Water Valves

Volkswagen Golf > VW Rabbit GTI 2006->

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Cooling system components, removing and installing

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

M A N U A L

Type 92S Pilot-Operated Steam Regulator

WORKING IN CONFINED SPACES GUIDELINES

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

Oil and Coolant Circulating Heating System. Model - OCSM

CEILING CASSETTE FAN COIL UNIT

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Transcription:

3.333.5275.246 Issue 7-2013 DT151F and DT152F Thermodynamic Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Maintenance 7. Spare parts E X P E R T I S E S O L U T I O N S S U S T A I N A B I L I T Y Copyright 2007

2 3.333.5275.246

ATTENZIONE Lavorare in sicurezza con apparecchiature in ghisa e vapore Working safely with cast iron products on steam Informazioni di sicurezza supplementari - Additional Informations for safety Lavorare in sicurezza con prodotti in ghisa per linee vapore I prodotti di ghisa sono comunemente presenti in molti sistemi a vapore. Se installati correttamente, in accordo alle migliori pratiche ingegneristiche, sono dispositivi totalmente sicuri. Tuttavia la ghisa, a causa delle sue proprietà meccaniche, è meno malleabile di altri materiali come la ghisa sferoidale o l acciaio al carbonio. Di seguito sono indicate le migliori pratiche ingegneristiche necessarie per evitare i colpi d'ariete e garantire condizioni di lavoro sicure sui sistemi a vapore. Movimentazione in sicurezza La ghisa è un materiale fragile: in caso di caduta accidentale il prodotto in ghisa non è più utilizzabile. Per informazioni più dettagliate consultare il manuale d'istruzioni del prodotto. Rimuovere la targhetta prima di effettuare la messa in servizio. Working safely with cast iron products on steam Cast iron products are commonly found on steam and condensate systems. If installed correctly using good steam engineering practices, it is perfectly safe. However, because of its mechanical properties, it is less forgiving compared to other materials such as SG iron or carbon steel. The following are the good engineering practices required to prevent waterhammer and ensure safe working conditions on a steam system. Safe Handling Cast Iron is a brittle material. If the product is dropped during installation and there is any risk of damage the product should not be used unless it is fully inspected and pressure tested by the manufacturer. Please remove label before commissioning

Prevenzione dai colpi d ariete - Prevention of water hammer Scarico condensa nelle linee vapore - Steam trapping on steam mains: Intervalli di 30 50 m. intervals Pendenza - Gradient 1:100 Vapore Steam Vapore Steam Pendenza - Gradient 1:100 Gruppo di scarico Trap set Gruppo di scarico Trap set Gruppo di scarico Trap set Condensa - Condasate Condensa - Condasate Condensa - Condasate Esempi di esecuzioni corrette ( ) ed errate ( ) sulle linee vapore: Steam Mains - Do's and Dont's: Flusso Flow Flusso Flow Vapore Steam

Prevenzione delle sollecitazioni di trazione Prevention of tensile stressing Evitare il disallineamento delle tubazioni - Pipe misalignment: Installazione dei prodotti o loro rimontaggio post-manutenzione: Installing products or re-assembling after maintenance: Evitare l eccessivo serraggio. Utilizzare le coppie di serraggio raccomandate. Do not over tighten. Use correct torque figures. Per garantire l uniformità del carico e dell'allineamento, i bulloni delle flange devono essere serrati in modo graduale e in sequenza, come indicato in figura. Flange bolts should be gradually tightened across diameters to ensure even load and alignment.

Dilatazioni termiche - Thermal expansion: Gli esempi mostrano l uso corretto dei compensatori di dilatzione. Si consiglia di richiedere una consulenza specialistica ai tecnici dell azienda che produce i compensatori di dilatazione. Examples showing the use of expansion bellows. It is highly recommended that expert advise is sought from the bellows manufacturer. Guide Guides Movimento assiale Axial movement Distanza breve Short distance Punto di fissaggio Fixing point Guide Guides Movimento assiale Axial movement Guide Guides Distanza media Medium distance Tiranti limitatori Limit rods Punto di fissaggio Fixing point Tiranti limitatori Limit rods Guide Guides Piccolo movimento laterale Small lateral movement Piccolo movimento laterale Small lateral movement Ampio movimento laterale Large lateral movement Ampio movimento laterale Large lateral movement

1. General safety information Installation and Maintenance InstructionsSafe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11 on this document) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use/application. These products comply with the requirements of the European Pressure Equipment Directive 97/23/EC and carry the mark when so required. It should be noted that product rated as SEP are required by the Directive not to carry the mark. The products fall within the following Pressure Equipment Directive categories: Prodotto Gas Gas Liquidi Liquidi Gruppo 1 Gruppo 2 Gruppo 1 Gruppo 2 DT151F DT152F DN ½", ¾", 1" - *SEP - *SEP DT151F DT152F DN 1½" - 1 - *SEP * Products within this category are required by the Directive not to carry the mark. I) These products have been specifically designed for use on steam, air or condensate /water, which is in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. II) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. III) Determine the correct installation situation and direction of fluid flow. IV) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. V) Remove protection covers from all connections before installation. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous enviroment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 3.333.5275.246 3

1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high /low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal permit to work system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post warning notices if necessary. 1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures over 500 C. Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to Maintenance instructions ). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Safety information Product specific See the specific details relating to product in the following Maintenance section. 1.16 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.17 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 4 3.333.5275.246

2. General product information 2.1 General description Series DT151F and DT152F thermodynamic steam traps are manufactured with carbon steel or alloy steel body; internal components are made from stainless steel. They are equipped with an internal maintainable strainer and are suitable for use with high pressure and high temperature steam. DT151F and DT152F traps can operate on plants with back pressure up to 50% of the inlet pressure. Standards These steam traps comply with the requirements of the European Pressure Equipment Directive 97/23/EC and carry the mark when so required. Certification The product is available with material certification to EN 10204 2.2 or EN 10204 3.1. Note: Certification and any tests must be specified at the time of order. Available types DT151F with carbon steel body and alloy steel cover DT152F with alloy steel body and cover Each type is available in four different executions with differentiated internal mechanism (type A, B, C, D) and sized in accordance to the discharge capacity requirements. 2.2 Pipe connections and sizes Connection types - Socket weld ends ANSI B16.11 SW, (standard) - Butt weld ends ANSI B16.25 BW, (standard) - Screwed ANSI B1.20.1 NPT (API), (standard) - Flanged UNI - DIN PN 100, 160, 250, (on demand) - Flanged ANSI B 16.5 class 600, 900, 1500 and 2500 RF, (on demand) Nominal sizes - DN ½, ¾, 1", 1½" (BW and flanged execution only). - DN 15, 20, 25, 40. Dimensions / weights (approximate) in mm e pesi in kg Size ½" ¾" 1" 1½" Connections type S Kg S Kg S Kg S Kg Threaded or to weld 160 7 160 7 160 7 160 7 PN 100/160 255 9 268 11 280 12 288 14 PN 250 285 12 288 13 295 14 325 19 ANSI 600 280 9,8 290 10,6 300 11,6 316 16 ANSI 900/1500 297 11,4 315 13,4 323 15,2 342 19,8 3.333.5275.246 5

2.3 Design limiting conditions (ISO 6552) Body design conditions ANSI 1500 PMA - Maximum allowable pressure @ 20 C 250 bar g DT151F/A-B-C @ 200 bar g 425 C TMA - Maximum allowable temperature DT151F/D @ 160 bar g 425 C DT152F/A-B-C @ 83 bar g 560 C DT152F/D @ 68 bar g 560 C Minimum allowable temperature -10 C PMO - Maximum operating suggested pressure 150 bar g* TMO - Maximum operating temperature DT151F 425 C DT152F 550 C Maximum operating back pressure as percentage of upstream pressure 50% Minimum differential pressure for satisfactory performance 10 bar g Designed for a maximum cold hydraulic test pressure of 375 bar g These values can be limited by the rating of the flanges installed. Pressure - temperature range Type DT151F Temperature C Pressure bar g Type DT152F Temperature C The product must not be used in this region Limit imposed by trim D Pressure bar g 6 3.333.5275.246

2.4 Materials Part Material Designation Body DT151F Carbon steel ASTM A 105 DT152F Alloy steel ASTM A 182 F 22 Cover Alloy steel ASTM A 182 F 22 Body gasket Stainless steel AISI 304 Studs Steel ASTM A 193 B 16 Nuts Steel ASTM A 194 g. 8 Trim set Stainless steel AISI S 400 Strainer screen Stainless steel AISI 316 Strainer cap Stainless steel AISI 316 2.5 Capacities The condensate discharge capacities can be deduced by the diagram below shown. Condensate kg/h Hot water capacity Cold water capacity Differential pressure bar 3.333.5275.246 7

3. Installation Note: Before actioning any installation, observe the General safety information in section 1. Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation. 3.1 The preferred installation is in a horizontal pipe as shown in the illustration, with the jutting part of the strainer beneath. 3.2 The inlet pipe should have a drop leg of at least 20 cm before the trap and continue vertically for a further 10 cm to create a small well to collect any impurities, better still with an exhaust valve fitted to manually blow-off the well. 3.3 The outlet pipe must be of appropriate diameter to support the considerable steam flashing that is caused with a very high differential pressure. 3.4 With a piped discharg to recovery system, the pipe should be sized with a maximum flash steam speed of 20 25 m/s. 3.5 Do not install the stop valve at less than 2-3 meters downstream from the trap. 3.6 If continuous operations are required or for easier maintenance work, a stop valve can be installed upstream, one downstream and another in bypass (see fig. 1). 3.7 When starting up, in order to ensure better exhaust of the air and uncondensed gas and to speed the warm up, open the bypass valve and then close it as son as the bypass line reaches a temperature close to that of the saturated steam. 3.8 The welding of the steam trap to the pipes must conform to national and international standards. The user must ensure that the correct welding procedure is used. Steam main Process Bypass valve DT151F / DT152F steam trap Fig. 1 - Process drain with discharge piped to recovery. 8 3.333.5275.246

4. Commisioning After installation or maintenance, check that the system works correctly and test all the alarms and protections devices. After 24 hours from the start up it is advisable to check the cover nuts tightening acting with a torque of 80 N m. 5. Operation The thermodynamic steam trap discharges condensation with a blast at a very high temperature; if the trap is to discharge to atmosphere ensure it is piped to a protected and safe place. 6. Manutenzione Note: Before actioning any maintenance program observe the General safety information in Section 1. 6.1 General Information Due to the specific set-up of the trap, no special maintenance is required. The trap operates correctly when the condensation is discharged in blasts, with a time interval between discharges during which the trap must be perfectly sealed. Inspect and clean the strainer ensuring that it is not blocked by any deposits or scaling, and replace if needed. 6.2 Replacing internal parts Warning: before to undertaking any maintenance on the trap it must be isolated from both the supply line and return line and any pressure allowed to safely normalise to the atmosphere. The trap should then be allowed to cool. 1. Open the trap by unscrewing the 6 nuts using a 24 mm spanner. 2. Dismantle the trim set using the following spanners: Trim set A 32 mm spanner Trim set B 36 mm spanner Trim set C 41 mm spanner Trim set D 50 mm spanner 3. After cleaning all joint faces, fit the new unit and tighten with a torque of about 140 N m. 4. Clean the gasket faces and close the unit, replacing the gasket if it is damaged and tighten in a crossed sequence. 5. To replace the strainer, unscrew the strainer cap using a 32 mm spanner, withdraw the screen and clean it or, if damaged, replace with a new one. For the reassembling there is no need of gasket; it is advisable to use a little anti-seize compound on the thread. Insert the screen in the cap slot and assemble tightening with a recommended torque of 200 N m. 3.333.5275.246 9

7. Spare parts The spare parts available are shown in the units given in the table. No other parts are available as spares. Available spares Internal trim set 1-2 Body gaskets set (3 off) 2 Strainer screen (1 off) 3 How to order spares Always order spares by using the description given in the table stating the type and DN of the trap. Example: Trim set for DT151F/ B DN 1" steam trap. 10 3.333.5275.246

3.333.5275.246 11

REPAIR Please contact our nearest Branch Office or Agent, or directly Spirax-Sarco S.r.l. Via per Cinisello 18-20834 Nova Milanese (MB) - Tel. +0362 49 17.1 - Fax +0362 49 17 315 LOSS OF WARRANTY Total or partial disregard of above instructions involves loss of any right to guarantee Spirax-Sarco S.r.l. - Via per Cinisello, 18-20834 Nova Milanese (MB) - Tel.: 0362 49 17.1 - Fax: 0362 49 17 307 3.333.5275.246 Issue 7-2013.06