25-4-2007 GC-MS Product overview 1 Agilent Technologies Agilent 5975-N singlequadrupole 1050 EI-inert, PCI, Agilent-MSD Chemstation Agiilent-6890 and 6850 spectral libraries and security pack available. Inert source, EI with CI source, Synchronous SIM/Scan, Quick swap, Dean switch, Deconvolution Reporting Software (DRS) ATAS Benelux B.V. LECO GC-TOF-MS PEGASUS IV 5-1000 amu EI Windows-based Data System. Dynamic Range of 4 to 6 orders, Total System Automation, max. 500 spectra/second range, ATAS Benelux B.V. JEOL JMS-T100GC 4-2000 amu EI CI (PCI and Direct Insertion Probe FAB EI,CI,DEI/DCI,FD/FI, > 5.000 Resolution, suitable for Fast GCMS, isolation valve, ATAS Benelux B.V. Agilent Technologies 5975C Series Diffusion- and Turbopump systems singlequadrupole 1,6-1050 amu EI Optional CI (PCI and Optional DIP Windows XP based Agilent-MSD Chemstation 5,200 amu/second with 0.1 amu scan step size, MS Spectral Library: NIST 02, Wiley 7th Edition, Stan Pesticide; Inert ion source: programmable up to 350 C, delivers enhanced response for active compounds and late eluters; Fully Hydrogen Safe Bruker Daltonics EM640 and EM640S mobile GC-MS single quadrupole 1-640 EI, FI (option) membrane inlet for air sampling Immediately usable for shockproof, ruggedized and fast analysis. Especially well suited for detection of chemical warfare agents; direct coupling to dedicated libraries for substance identification (chemical warfare, catastrophy management)
25-4-2007 GC-MS Product overview 2 Bruker Daltonics mm2 mobile GC- MS single quadrupool. 1-520 membrane inlet for air sampling. Immediately usable, low weight (30 kg!). Within 15 minutes identification of soil, water or air samples. Especially well suited for detection of chemical warfare agents; direct coupling to dedicated libraries for substance identification (chemical warfare, catastrophy management) Da Vinci Europe Laboratory Solutions B.V. LECO GC-TOF-MS PEGASUS IV 5-1000 amu EI Windows-based Data System. Dynamic Range of 4 to 6 orders, Total System Automation, max. 500 spectra/second range, Da Vinci Europe Laboratory Solutions B.V. JEOL JMS-T100GC 4-2000 amu EI CI (PCI and Direct Insertion Probe FAB EI,CI,DEI/DCI,FD/FI, > 5.000 Resolution, suitable for Fast GCMS, isolation valve, Da Vinci Europe Laboratory Solutions B.V. Agilent singlequadrupole Technologies 5975C Series Diffusie- en Turbopomp 1,6-1050 amu EI Optional CI (PCI and Optional DIP Windows XP based Agilent-MSD Chemstation 5,200 amu/second with 0.1 amu scan step size, MS Spectral Library: NIST 02, Wiley 7th Edition, Stan Pesticide; Inert ion source: programmable up to 350 C, delivers enhanced response for active compounds and late eluters; Fully Hydrogen Safe Interscience FocusDSQII single quadrupool 2-1050 EI, PCI,, FocusGC curved prefilter-technologie; 11.111 amu/sec en tot 50 scans per seconde, vacuumslot, SIM/Fullscan simultaan, 70,250 of 400 L/sec turbo
25-4-2007 GC-MS Product overview 3 Interscience TraceDSQII single quadrupool 2-1050 EI, PCI,, deconvolution by means of Xtract interace Trace GC Ultra, UFM-column module (up to 1200 C/min.) Comprehensive GC x GC curved prefilter-technology, vacuum slot, DIP/DEP probes and digital CIcontrol, 11.111 amu/sec up to 50 scans per second, SIM/Fullscan simultaneous and PPINICI; 70, 250 or 400 L/sec turbo Interscience Focus PolarisQ ion-trap (MSx MS) 10-1023 EI, PCI,, FocusGC External Ionisation chamber with vacuum slot, MS-MS (MSn n=5), 70, 250 of 400L/sec turbo Interscience TracePolarisQ ion-trap (MS x MS) 10-1023 EI, PCI,, Trace GC Ultra, UFM-column module (up to 1200 C/min.) Comprehensive GC x GC External Ionisation chamber with vacuum slot, MS-MS (MSn n=5), DIP/DEP Probes, digital CI-control, PPNICI, variabel damping gas 70 or 250 L/sec turbo Interscience Tempus Plus TOF 2-1000 EI, PCI, Trace GC Ultra, UFM-column module (up to 1200 C/min.) Comprehensive GC x GC Benchtop, 100 scans/sec, >10^5 dynamic range, classical spectra Interscience Syft Voice100 Selected ion flow tube 10-240 CI Syft 3 precursor ions (H3O+, O2+ en NO+), analysis time from 15 sec, calibration not necessary JAS Benelux Agilent 5975 Inert MSD quadrupole 1.6-800 amu EI, PCI en. Full LAN communication JAS Benelux JAS / Agilent quadrupole 1.6-800 amu EI, PCI en 5975 double MSD. Full LAN communication The JAS double MSD allows both EI and CI in 1 run JAS Benelux JAS /QQQ MS Triple quad 1.6-800 amu EI, PCI en. Full LAN communication JAS Benelux GCxGC met Agilent 5975 Inert MSD quadrupole 1.6-800 amu EI, PCI en. Full LAN communication JEOL (EUROPE) B.V. GCMateII magnetic sector, double focussing 2,500 EI, PCI,, FAB, DIP JEOL (Windows) Agilent-7890A 5000 Resolution, Benchtop Model, Full Automatic Probe, MS/MS Linked scan
25-4-2007 GC-MS Product overview 4 JEOL (EUROPE) B.V. Mstation JMS-700 magnetic sector, double focussing JEOL (EUROPE) B.V. JMS-800D magnetic sector, double focussing JEOL (EUROPE) B.V. JMS-T100GC 25,000 EI, PCI,, FAB, FD, FI, DCI, JEOL Agilent-7890A 60 000 resolution 25,000 EI, PCI,, JEOL Agilent-7890A 60 000 resolution specific for doxin analysis > 2,000 EI, CI, (pos & neg), DIP, DEP, DEI/DCI, FD/FI JEOL (Windows) Agilent-7890A > 5.000 Resolution JEOL (EUROPE) B.V. JMS-Q1000GC Quadrapole 1,500 EI, CI, DIP JEOL (Windows) Agilent-7890A > 2.500 Resolution, S/N > 120 Leco Instrumente GmbH Leco Pegasus IV GC-TOF MS 5-1000 amu EI Complete Automated, Quality Deconvoution, Matrix Masking of (Windows based) Agilent 6890N GC, Agilent 7890 Dynamic Range of 4 to 6 orders, Total GC, Agilent 7683 AutoSampler, System Automation, max. 500 GC-PAL AutoSampler, CombiPAL spectra/second range Robot/Sampler, RVM-LTM / MACH, Upgradable to GC GC- TOF MS MSVision MSVision MSVision IonSpec/Varian ProMALDI FTMS (7.0 Tesla magnet) IonSpec/Varian ProMALDI FTMS (9.4 Tesla magnet) MS Solutions GC- IsoTOF Ion Cyclotron Resonance (ICR) Ion Cyclotron Resonance (ICR) 15-8,500 (+ Maldi) 15-18,000 (+ Maldi) Omega 2XP (Windows XP), PeakHunter, de novo sequencing Omega 2XP (Windows XP), PeakHunter, de novo sequencing Varian CP-3800, Agilent 6890 Varian CP-3800, Agilent 6890 MS/MS options: CID, ECD, IRMPD, simultaneous ECD/IRMPD MS/MS options: CID, ECD, IRMPD, simultaneous ECD/IRMPD TOF 15-2000 Mass Analyser Pro (Windows XP) Agilent 6890 multidimensional GC, linear range: 6 decades
25-4-2007 GC-MS Product overview 5 PerkinElmer Benelux (M. Visscher) Clarus 600 singlequadrupole GC/MS in C, T, S, or D version 1-1200 EI, in C- version also CI+, CI- Turbomass (Windows XP) PerkinElmer Clarus 500 GC PCI/ optie, fast scanning, SIFI Mode with Simultaneous Full Scan and SIR, LVI and unique MS Vent (columm backflush or column change without vacuum stop), Touchscreen monitoring. Different pumping capacities in C, T, S, and D versions Shimadzu Benelux QP2010S singlequadrupole 1.5-900 EI, dual filament GCMSsolutions met MS Navigator (Windows 2000, XP) Shimadzu GC2010 (+ GC extra detector) AOC20/AOC5000 autoinjector for Headspace, SPME, Thermal Desorbtion and Pyrolysis. Direct Insertion probe and Pyrolyse unit possible, diverse specific spectral libraries available, very useful for Basic GCMS Shimadzu Benelux QP2010plus singlequadrupole 1.5-1090 EI, PCI, combinatie PCI, CI and SEI. Dual filament GCMSsolutions met MS Navigator (Windows 2000, XP) Shimadzu GC2010 (+ GC extra detector) AOC20/AOC5000 autoinjector for Headspace, SPME, Thermal Desorbtion and Pyrolysis. Same as QP2010 except: extreme sensitivity 1pg OFN >160:1. FAST Scan/SIM. Automated Ajustable Retention TImes. Real Dual Column GCMS. Thermo Fisher Scientific Quadrupole, iontrap en TOF via Interscience Thermo Fisher Scientific DFS Magnetic sector (BE) 2-6000 Da EI, CI ( Pos en Neg.) FAB, FD/FI Xcalibur (Windows XP) Trace GC and Agilent 6890 Optional DIP and DCI probes. System may be upgraded to LC-MS (APCI and ESI). Special Dioxin configurations available with 1 of 2 GC's Thermo Fisher Scientific Delta V Advantage GC-IRMS (C,H,N,O en S isotoop ratio) Magnetic sector 1-80 Da at 3 KV EI source ISODAT NT (Windows XP) Trace GC and Agilent 6890 Options like Elemental Analyser, Gasbench, Carbonate and LC-Isolink Thermo Fisher Scientific Delta V Plus GC- Magnetic IRMS sector (C,H,N,O en S isotoop ratio) 1-96 Da at 3 KV EI source ISODAT NT (Windows XP) Trace GC and Agilent 6890 Options likeelemental Analyser, Gasbench, Carbonate en LC-Isolink. Number of collectors extendable to 10 Faraday cups Thermo Fisher Scientific Finnigan MAT253 GC-IRMS (C,H,N,O,S en isotoop ratio) Magnetic sector 1-150 Da at 10 KV EI source ISODAT NT (Windows XP) Trace GC and Agilent 6890 Options like Elemental Analyser, Gasbench, Carbonate and LC-Isolink; also continuous flow H/D measurements. Extentable to 8 aquisition channels
25-4-2007 GC-MS Product overview 6 Varian B.V. Saturn 2100 ion-trap 650 EI, CI, MS Workstation 6.8 3900 GC MS-MS / SIS / liquid CI Varian B.V. Saturn 2200 ion-trap 650 EI, CI MS Workstation 6.8 3800 GC MS-MS / SIS / liquid CI Varian B.V. 4000 GC/MS ion-trap 10-1000 EI, PCI,, Hybrid CI MS Workstation 6.8 3800 GC Internal and External Ionisation + Hybride Chemical Ionisation for extra selectivity; MS/MS; scan speed 10000(u/s) Varian B.V. 320 Singlequadrupole singlequadrupole 2000 EI, PCI, MS Workstation 6.8 3800 GC Direct Insert & exposure Probe / Vacuum interlock standard / Curved collision cell / possibility to upgrade to LC/MS/MS and GC/MS/MS Varian B.V. 320 Triplequadrupole triplequadrupole 2000 EI, PCI, MS Workstation 6.8 3800 GC Direct Insert & exposure Probe / Vacuum interlock standaard / Curved collision cell / possibility to upgrade to LC/MS/MS and GC/MS/MS Varian B.V. 1200 Triplequadrupole triplequadrupole 800 EI, PCI, MS Workstation 6.8 3800 GC MS-MS / Probe / Vacuum interlock standaard / Curved collision cell / possibility to upgrade to LC/MS/MS Waters, Micromass technologies GCT Premier vluchttijd 1500 EI, PCI,, FI MassLynx 4.1 (Windows XP of Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated links to :pd-quest. ACD, nugenesis, Options like TargetLynx Proteinlynx global server, Metabolynx, Chromalynx Agilent-6890, various injectors and autosamplers like CTC Pal Resolution 7000 at 3.5 GHz TDC; better than 1 mda for m/z < 200, better than 5 ppm for m/z > 200; Solid-probe option; DRE; Linear dynamic range 4 orders Waters, Micromass technologies Quattro-Micro-API triplequadrupool 1200 EI, PCI,, MassLynx 4.1 (Windows XP of Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated links to :pd-quest. ACD, nugenesis, Options like TargetLynx Proteinlynx global server, Metabolynx, Chromalynx Agilent-6890, various injectors and autosamplers like CTC Pal Bechtop MS/MS Solid-probe option
25-4-2007 GC-MS Product overview 7 Waters, Micromass technologies AutoSpec Premier Sector vanaf 3000 Naast EI, CI, de meeste alle ionisatie technologie. MassLynx 4.1 (Windows XP of Windows 2000), MassLynx is CFR 21 part 11 complaint.; various integrated links to :pd-quest. ACD, nugenesis, Options like TargetLynx Proteinlynx global server, Metabolynx, Chromalynx Agilent-6890, various injectors and autosamplers like CTC Pal resolution 60000 (20% valley)