Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+



Similar documents
GPD Rubber Press Seals

Puddle Flange. FRANK Puddle Flange

WATERPROOFING OF WET ROOMS

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Chapter. Restoration of Damaged Structures

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

SikaProof A Technology

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

12.1 Schlüter -KERDI-BOARD

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

WATERPROOFING SikaProof -A TECHNOLOGY

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

Waterproofing construction Joints

Plastics Engineering SYSTEM BEKAPLAST. Mechanically anchored thermoplastic lining for extreme conditions

building applications copper - redefined

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Concrete Waterproofing Systems. Integral Protection.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

Site Inspection Report

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

Drains and shower channels. Wastewater Drainage

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Current opportunities of sprayed waterproofing membrane. Frank Clement Technical Manager Sprayable Membranes MEYCO Global Underground Construction

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

SIGRAFLEX . Properties. Applications

September September Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. akt-uk.com

Syphonic Roof Drainage

MULTI-TIGHT 2K. The New Generation for Waterproofing Buildings

Saferand easierinstallation

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

GK Packing System Welding Instructions

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

plumbing products guide

Embedded Parts Introduction - Anchors

The bonded waterproof membrane, which can be verified by non destructive means DENSARE /14 IHö/JP/KK

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Mineral waterproof coating PCI Dichtschlämme

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

How to build raised beds page

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Basement Waterproofing in Existing Buildings

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Building Owners Guide to a Duro-Last System!


Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

The AQUAFIN Approach to Concrete Repair

SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO

Chapter 2 Basis of design and materials

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

TECHNICAL SPECIFICATION

external Basement waterproofing

SECTION PRECAST CONCRETE UTILITY STRUCTURES

external Basement waterproofing

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

How to build a Pizza Oven in 4 days

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

SECTION PRECAST CONCRETE STRUCTURES

Passive Fire Protection

High Performance PSA in Sheet Membrane in Water Protection

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

WATERPROOFING BASEMENTS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Section SEWER PIPE INSTALLATION AND TESTING

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Seamless Waterproofing. Systems

WATERPROOFING SIKAPLAN MEMBRANE SYSTEMS FOR BASEMENTS TECHNOLOGY & CONCEPTS

8.7 Schluter -KERDI-LINE

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

SECTION STORM DRAINAGE SYSTEM

constructive solutions Fosroc total waterproofing protection of below-ground structures

The Guide To Waterproofing An Existing Basement

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

DEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE

Packaged Terminal Air Conditioner Wall Sleeve Installation

ElastoFlake & ElastoTec

Transcription:

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves are a quick and inexpensive way to obtain a perfectly round building entry. They are available in different materials and designs for various applications. Wall sleeves are available for inserting into the shuttering, for joint grout applications and subsequent dowelling. Even the connection to bituminous thick coatings or waterproof membranes required by DIN 18195 part 6 for pressing water or standing seepage water can be realized by using sophisticated fixed / loose flange constructions. The problem: Wall sleeve is a common term often associated with a standard pipe without any additional refinements. There are numerous criteria, however, that should be taken into account when referring to a wall sleeve. Among other things, material and design play an important role. When a thin-walled wall sleeve or wall sleeve of substandard quality is set in concrete, deformations will occur. As a result, no standard seal will fit into the opening and an expensive, customised product will have to be used. KG pipe misused as wall sleeve KG pipe as wall sleeve A standard thick-walled pipe is not sufficient. During the curing of the concrete, a reduction in volume occurs and micro cracks can develop between the wall sleeve and concrete resulting in leakage. An additional water barrier flange, special coating or special surface finish are essential for wall sleeves that are to be set in concrete. In the case of wall sleeves for dowelling and fixed / loose flange constructions, however, other parameters such as the distance of the dowel holes, materials, thickness and hardness of the interlays, the connection to the bituminous thick coating and much more, play a significant role and are ultimately decisive for the permanent leak tightness of a building. The solution: As experts for sealing products, we know that a perfectly tight building entry starts with the properly created hole in the wall. This is the reason why for decades we have been developping wall sleeves and flanges which are innovative, of high-quality and easy to install, and which make your building absolutely gas- and watertight when used together with our press seals. 2

Overview wall structure / Sealing of building entries Basis to determine the appropriate wall sleeves Wall type basement/ Wall structure Sealing according to DIN 18195 Part 4 Soil humidity and non-standing seepage water No. 1 brick-built basement wall Sealing according to DIN 18195 - Part 6 Standing seepage water and pressing water No. 5 brick-built basement wall Brick-built basement wall outside of building outside of building No. 2 concreted basement No. 6 concreted basement Concreted basement outside of building No. 3 double wall / element wall outside of building No. 7 double wall / element wall Double wall / Element wall outside of building No. 4 thermal insulation Double wall / Element wall with thermal insulation outside of building No. 8 thermal insulation double wall / element wall double wall / element wall outside of building outside of building Waterproof concrete according to DIN 1045 Concreted basement with waterproof concrete No. 9 concreted basement Double wall / element wall with waterproof concrete No. 10 double wall / element wall Double wall / element wall with waterproof concrete and thermal insulation No. 11 thermal insulation double wall / element wall If you do not find your wall structure among above examples, kindly let us have a sketch. cablepipebuildingentry+ 3

Standard wall sleeve Cement-coated wall sleeve KIWA test construction tested ZVR (D)/X Features and technical data: watertight up to 5 bar thanks to continuous water barrier, suitable for any wall type homogeneous bond with the masonry thanks to its special coating extremely low weight sealed ready for installation, break-resistant and dimensionally stable easy on-site adjustment to required wall thickness available in any length pipe diameters from 80 300 mm Wall sleeve with special coating The new cement-coated wall sleeve consists of a break-resistant, inherently stable plastic wall sleeve and a cement-bound special coating. This coating adheres perfectly to the wall sleeve, bonds homogeneously with the concrete and compensates any temperature variations. The cementcoated wall sleeve can either be set in concrete, brick walls or used in joint grout applications. The wall sleeve is water pressure tight up to 5 bar certified by KIWA construction test and is ideally suitable for use in white tanks. Suitable for wall types no. 1 4 and 9 11. 4

Standard wall sleeve Cement-coated wall sleeve Special coating Pipe diameters from 80 300 mm ZVR in concrete wall ZVR in double wall / element wall cablepipebuildingentry+ 5

Standard wall sleeves Fibre cement wall sleeves MFPA tested FZR (D)/X Fibre cement wall sleeve closed With the asbestos-free fibre cement wall sleeve all types of pipes can be brought into buildings through walls, ceilings and floors. Thanks to its stability, it is particularly suitable for large pipe diameters. The fibre cement wall sleeve can be embedded in concrete or in masonry work or cast into wall penetrations with mortar. The grooved surface creates a tight connection to the building. The wall sleeve is corrosion-resistant, tight against pressing water and electrically non-conductive. FZR-G (D)/X Fibre cement wall sleeve split The proven asbestos-free fibre cement wall sleeve in split design is ideally suitable for subsequent sealing of pipes and cables that have already been laid. For this purpose, the wall sleeve can either be set in concrete, walled in, or used for joint grout applications. The grooved surface creates a tight connection to the building. The wall sleeve is corrosion-resistant, tight against pressing water and electrically non-conductive. Suitable for wall types no. 1 4 and 9 11. Suitable for wall types no. 1 4 and 9 11. 6

Standard wall sleeves / flange wall sleeves Plastic/stainless steel wall sleeves Basic SFR (D)/X Renovation wall sleeve Renovation wall sleeves are plastic wall sleeves, which are extremely light, absolutely dimensionally stable and resistant to breakage. They can be retrofitted in breakthroughs and/or rectangular openings. The rough surface of these wall sleeves bonds homogeneously with the mortar. Renovation wall sleeves offer users maximum freedom. Extremely flexible to install, they can easily be cut to the required length and later retrofitted into the masonry and concrete walls. HRD (D)-FUM/X X = wall thickness in mm Wall sleeve with puddle flange The stainless steel pipe is provided with a puddle flange as an additional water barrier for inserting flush into the shuttering. The large puddle flange ensures a firm positive connection after setting in concrete. Additionally, the high quality stainless steel ensures that the HRD wall sleeve FUM is excellently suitable for use in extreme conditions, such as loads caused by mechanical forces. Material: V2A (AISI 304L) or V4A (AISI 316L) Suitable for wall type no. 9 Suitable for wall type no. 1 cablepipebuildingentry+ 7

Flange wall sleeves Stainless steel wall sleeves KIWA test construction tested HRD (D)-F Flange closed Stainless steel flange for building entries to be sealed in front of the wall. Suitable for waterproof concrete stress class 1 for subsequent dowelling on existing walls, base slabs or recesses. Connection to a PMBC in compliance with DIN 18195 part 4 is possible. Material: V2A (AISI 304L) or V4A (AISI 316L) HRD (D)-FG Flange split Split stainless steel flange for building entries to be sealed in front of the wall. Suitable for waterproof concrete stress class 1 for subsequent dowelling on existing walls, base slabs or recesses. For cables or pipes that have already been laid. Connection to a PMBC in compliance with DIN 18195 part 4 is possible. Material: V2A (AISI 304L) or V4A (AISI 316L) Suitable for wall types no. 1 4 and 9 11. Suitable for wall types no. 1 4 and 9 11. We recommend to apply the elastic sealant Sikaflex in order to optimize uneven surfaces. 8

Flange wall sleeves Wall sleeves in galvanized design HRD (D)-FUF-vz HRD (D)-FUFA-vz Galvanized wall sleeve with fixed / loose flange for setting in concrete The galvanized fixed / loose flange wall sleeve allows all types of pipes to be inserted into buildings through walls, ceilings and floors. The wall sleeve can either be set in concrete, brick walls or used in joint grout applications. With the fixed/loose flange according to DIN 18195 part 9, buildings can be made watertight as defined in DIN 18195 part 6. Please contact the manufacturer of the surface sealing for more information regarding the interlay to be used. Galvanized wall sleeve with fixed / loose flange for dowelling The galvanized fixed / loose flange wall sleeve allows all types of pipes to be inserted into buildings through walls, ceilings and floors. The fixed/loose flange is subsequently dowelled onto a wall sleeve or a core drilling. With the fixed/loose flange according to DIN 18195 part 9, buildings can be made watertight as defined in DIN 18195 part 6. Please contact the manufacturer of the surface sealing for more information regarding the interlay to be used. Suitable for wall types no. 5 8. Suitable for wall types no. 5 11. cablepipebuildingentry+ 9

Flange wall sleeves Stainless steel wall sleeves HRD (D)-FUF/o/u o = upper lenght, u = lower lenght HRD (D)-FUFA/o/u o = upper lenght, u = lower lenght Stainless steel wall sleeve with fixed / loose flange for setting in concrete The stainless steel fixed / loose flange wall sleeve allows all types of pipes to be inserted into buildings through walls, ceilings and floors. The wall sleeve can either be set in concrete, brick walls or used in joint grout applications. With the fixed/loose flange according to DIN 18195 part 9, buildings can be made watertight as defined in DIN 18195 part 6. The high-quality stainless steel makes the HRD-FUF corrosion-resistant and thus ideally suitable when exposed to chemicals. Please contact the manufacturer of the surface sealing for more information regarding the interlay to be used. Stainless steel wall sleeve with fixed / loose flange for dowelling The stainless steel fixed / loose flange wall sleeve allows all types of pipes to be inserted into buildings through walls, ceilings and floors. The fixed/loose flange is subsequently dowelled onto a wall sleeve or a core drilling. With the fixed/loose flange according to DIN 18195 part 9, buildings can be made watertight as defined in DIN 18195 part 6. The high-quality stainless steel makes the HRD-FUFA corrosion -resistant and thus ideally suitable when exposed to chemicals. Please contact the manufacturer of the surface sealing for more information regarding the interlay to be used. Material: Material: V2A (AISI 304L) or V4A (AISI 316L) V2A (AISI 304L) or V4A (AISI 316L) Suitable for wall types no. 5 8. Suitable for wall types no. 5 11. 10

Flange wall sleeves Accessories for sealing in accordance with DIN 18195 part 6 Z-(D)-FUF(A) Z-(D)-FUF(A)-KMB For welded membranes Depending on the sealing membrane used, one rubber inlay will benecessary in the clamping area for multi-layer sealings glued together with bitumen. When only one layer is loosely laid, two inlays of 2 or 6 mm thickness might be necessary (one on each side of the layer). The inlays must be made of the same material or a compatible elastomer. We recommend thus the matching inlay sets. In compliance with DIN 18195 part 9, the torques of the screws must be adapted to the flange design and sealing type. Selection aid suitable inlays for sealing of buildings For bituminous coating (PMBC) With the tested Hauff sealing fleece, personnel used to working with PMBC can install the fix/loose flange and apply the 2-layer surface sealing in one single step. It is suitable for use in single-storey basement construction or for foundation depths up to a maximum of 3 m DIN 18195 part 6 (test certificates are available for bituminous sealing PCI and Mapei). Accessory kit: Fixed/loose flange wall sleeve Z-(D) 2/3/6 mm EPDM/silicon DIN EN 13967 Plastic and elastomer sheets for waterproofing of buildings X DIN EN 13969 Bitumen sheets for waterproofing of buildings X DIN EN 14909 Plastic and elastomer damp proof courses X DIN EN 14967 Bitumen damp proof courses X Accessory kit: Fixed/loose flange wall sleeve Z-(D) KMB fleece + 2 mm EPDM KMB PCI- Pecimor 2K X KMB Mapei Platimul 2K X Inlays for fixed / loose flange sealing For underground sealings of buildings with waterproof membranes or bituminous coatings German Industrial Norm for fixed/loose flange sealing DIN 18195 part 9: 2010-05 applies. (When the sealings are made with polymer modified bituminous thick coatings (PMBC) or waterproof membranes according to DIN 18195 part 2:2009-04 for standing seepage water and pressing water according to DIN 18195 part 6:2011-12 (called black tank).) Please follow the installation instructions of the manufacturer of the waterproof membrane or bituminous coating. cablepipebuildingentry+ 11

Hauff-Technik GmbH & Co. KG Robert-Bosch-Straße 9 89568 Hermaringen, GERMANY Tel. +49 7322 1333-0 Fax +49 7322 1333-999 futterrohre_en_141021 office@hauff-technik.de www.hauff-technik.de The information in this publication represents our current state of technical knowledge and experience. However, given the multitude of possible influences affecting the processing and use of our products, this information does not exempt processors and users from running their own tests and trials. We will replace any parts that cannot be used due to defective materials. We do not replace parts for defects caused due to transport, storage or faulty installation and the consequences thereof. All information without guarantee.