Customizing The Dude MUM Budapest 2011 by Patrik Schaub



Similar documents
Dude Workshop. MUM Prague 2009 by Patrik Schaub. FMS

A Dude probing SNMP! Building custom probes and configuring equipment using SNMP with The Dude. Andrea Coppini AIR Wireless - Malta andrea@air.com.

RouterBOARD product overview. September, Gon Tel: +44 (0) Fax: +44 (0)

D-Link Central WiFiManager Configuration Guide

Konica Minolta s Optimised Print Services (OPS)

Manual:The Dude/Server settings

NMS300 Network Management System

SevOne NMS Download Installation and Implementation Guide

Net Inspector 2015 GETTING STARTED GUIDE. MG-SOFT Corporation. Document published on October 16, (Document Version: 10.6)

Features Overview Guide About new features in WhatsUp Gold v14

These options allow you to define baseline settings for how scanning will occur on your network


Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1

Installing and Using the vnios Trial

Assignment One. ITN534 Network Management. Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition)

NetBrain Discovery Appliance Manual

Using SolarWinds Orion for Cisco Assessments

Dynamic DNS How-To Guide

Management Pack for vrealize Infrastructure Navigator

Wireless Tips and Tricks for RouterOS v6. MUM South Africa 2013 Johannesburg Uldis Cernevskis MikroTik

Table of Contents 1. Introduction Installing Sxblue Server Principle of Operation Server Configuration

Quick Start Guide. Cerberus FTP is distributed in Canada through C&C Software. Visit us today at

School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management

FileMaker Server 15. Getting Started Guide

Managing Qualys Scanners

Network Monitoring with SNMP

Pandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide

OnCommand Performance Manager 1.1

Deploying Intellicus Portal on IBM WebSphere

MikroTik Certified Network Associate (MTCNA) Training outline

網 路 品 質 管 理 工 具 The Dude 簡 介

DEPLOYMENT GUIDE Version 1.1. Deploying F5 with Oracle Application Server 10g

Application Monitoring using SNMPc 7.0

BlackBerry Enterprise Service 10. Version: Configuration Guide

LifeSize UVC Manager TM Deployment Guide

13.1 Backup virtual machines running on VMware ESXi / ESX Server

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

emerge 50P emerge 5000P

IntraVUE Plug Scanner/Recorder Installation and Start-Up

IBM Security QRadar SIEM Version MR1. Vulnerability Assessment Configuration Guide

+ Configuration+Guide+ +Monitoring+ Meraki+Access+Points+with+Solarwinds+ Orion+using+SNMP+

Setting up VMware ESXi for 2X VirtualDesktopServer Manual

Online Help StruxureWare Data Center Expert

Configuration Guide BES12. Version 12.3

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide

The Dude 4. Documentation.

OnCommand Performance Manager 1.1

Centerity Monitor. Technical Guide: Centerity VCE VBlock Monitoring V6.15

DEPLOYMENT GUIDE Version 1.1. Deploying F5 with Oracle Fusion Middleware Identity Management 11gR1

Test Case 3 Active Directory Integration

Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device

SNMP Adapter Installation and Configuration Guide

Web Load Stress Testing

Using Device Discovery


Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent?

Setting Up SSL on IIS6 for MEGA Advisor

FileMaker Server 13. Getting Started Guide

DEPLOYMENT GUIDE Version 1.0. Deploying F5 with the Oracle Fusion Middleware SOA Suite 11gR1

This guide provides instructions on how to configure SNMP feature on Yealink IP phones and test SNMP feature using a free SNMP test tool.

External Device Management - Using SNMP - Enabling the Next Wave of Connectivity


CAPsMAN Case Study. Uldis Cernevskis MikroTik, Latvia. MUM Pittsburgh September 2014

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Configuration Guide BES12. Version 12.1

DEPLOYMENT GUIDE Version 1.2. Deploying F5 with Oracle E-Business Suite 12

RUGGEDCOM NMS. Monitor Availability Quick detection of network failures at the port and

Batch Scanning. 70 Royal Little Drive. Providence, RI Copyright Ingenix. All rights reserved.

Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1.

S&C IntelliTeam CNMS Communication Network Management System Table of Contents Overview Topology

Vital Security Web Appliances NG-1100/NG-5100/NG How to Use Simple Network Management Protocol (SNMP) Monitoring

Management Center. Installation and Upgrade Guide. Version 8 FR4

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

HTTP communication between Symantec Enterprise Vault and Clearwell E- Discovery

Version 1.0 January Xerox Phaser 3635MFP Extensible Interface Platform

Active Management Services

Microsoft SharePoint 2010 Deployment with Coyote Point Equalizer

PANDORA FMS NETWORK DEVICE MONITORING

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Configuration Guide BES12. Version 12.2

How to configure an Advanced Expert Probe as NetFlow Collector

Quick Installation Guide For Sensors with Cacti

Kaltura On-Prem Evaluation Package - Getting Started

EMC Smarts Integration Guide

SCS100 CATVisor SNMP COMMANDER

Host Installation on a Terminal Server

Virtual Appliance for VMware Server. Getting Started Guide. Revision Warning and Disclaimer

How To Get Started With Whatsup Gold

Customer Tips. Xerox Network Scanning TWAIN Configuration for the WorkCentre 7328/7335/7345. for the user. Purpose. Background

Virtual Managment Appliance Setup Guide

NNMi120 Network Node Manager i Software 9.x Essentials

RPM Utility Software. User s Manual

Xerox Multifunction Devices. Verify Device Settings via the Configuration Report

Copyright 2008 Link Technologies,Inc. A Proud Vendor Member of the

OnCommand Unified Manager

vrealize Automation Load Balancing

JetAdvice Manager Data Collector v Date:

MFPConnect Monitoring. Monitoring with IPCheck Server Monitor. Integration Manual Version Edition 1

New Obvious and Obscure MikroTik RouterOS v5 features. Budapest, Hungary MUM Europe 2011

Transcription:

Customizing The Dude MUM Budapest 2011 by Patrik Schaub FMS Internetservice, www.fmsweb.de info@fmsweb.de, Phone: +49 761 2926500 copyright FMS 2011

About FMS FMS www.fmsweb.de

About FMS Founded in 1999 MikroTik Distribution (www.mikrotikshop.de) Training (www.mikrotiktraining.de) Consulting and service contracts Custom AAA development / API development Supplementary products Product development

What else is FMS doing Microwaves Microwave solutions Licensed and light licensed band Unlicensed band Multiple vendors SIAE Microelettronica, Italy SAF Tehnika, Latvia Services General Consulting Planning of advanced setups Protected setups (1+1) or ring topologies Aggregated links, x * (1+0)

What else is FMS doing Last mile Our #1 solution: MikroTik WIMAX (Outdoor) DSLAMs, ADSL/VDSL Fttx

Visit our Distributor Table See the proto type: Ogma Connect 2600???? Get the news: Low cost Restless Powerbox Win an intelligent Power Supply: Restless Powerbox Compact

Customisation 3 real world examples

Example#1 Enhance Auto Discovery for RouterBOARD devices

Objectives Discover RouterBOARD type Show right image

Standard Auto Discovery Output FMS www.fmsweb.de

Enhanced Auto Discovery Output

Steps to take 1. Create a new device type for each RouterBOARD 2. Set appearance options for device types 3. Set discovery options for device types

1) Create new Device Type FMS www.fmsweb.de

2) Set apperance options Icon: Image (JPG, GIF) or vectorbased (SVG) Upload to Dude like Other files

3) Set discovery options How to identify a device type by scanning? Guessing by combination of scanned services By availability of a vendor dependent service By SNMP query Requires support by the device Which OID to check?

SNMP Walk FMS www.fmsweb.de

Create Probe FMS www.fmsweb.de

Modify new probe FMS www.fmsweb.de

Identification Required Probe = CheckForRB750Series Allowed Probes = CheckForRB750Series + anything

Identification Result: Devices with RouterOS RB750 in SNMP answer will be detected as device type RB750Series Remark: Treat Service as available only if up ensures, that other answers will be interpreted as service not available

Services Tab Checked box = a service, that was available during discover will not be added to the monitoring list of the device Ignore device detection probe

Details about SNMP OID Many vendors give system information by SNMP OID 1.3.6.1.2.1.1.1.0 RouterOS behaviour until ROS 4.x from ROS 5.x value = router value = RouterOS RB750G

Different behaviour in ROS 4 and 5

Example 2 ALFO Performance

SIAE ALFO Full Outdoor Microwave The vendor SIAE from Italy Market leader in Germany Carrier grade The device ALFO, 100MBit Full Outdoor Medium priced Often used for connecting MikroTik base stations

Identification As in the last example With SNMP based probe: OID: 1.3.6.1.2.1.1.1.0 Compare: Regex (iso.org.dod.internet.mgmt.mib2.system.sysdescr.0) Value: ALFO MIB

LinkLabels FMS www.fmsweb.de

LinkLabels FMS www.fmsweb.de

Edit Labels FMS www.fmsweb.de

Label Function String Variable String Variable Function [snmp_wireless_link_info()] Rx: [Interface.InBitRate] [snmp_wireless_link_rx_rate()] Tx: [Interface.OutBitRate] [snmp_wireless_link_tx_rate()]

Custom ALFO Labels FMS www.fmsweb.de

Label 1 10.20.1.11 Rx: [oid("1.3.6.1.4.1.3373.12.10.1.1.13.0","5","300","10.20.1.11","alfo")] dbm Tx: [oid("1.3.6.1.4.1.3373.12.10.1.1.12.0","5","300","10.20.1.11","alfo")] dbm Rx: [Interface.InBitRate] Tx: [Interface.OutBitRate] 10.20.1.12 Rx: [oid("1.3.6.1.4.1.3373.12.10.1.1.13.0","5","300","10.20.1.12","alfo")] dbm Tx: [oid("1.3.6.1.4.1.3373.12.10.1.1.12.0","5","300","10.20.1.12","alfo")] dbm

OID Function oid("1.3.6.1.4.1.3373.12.10.1.1.13.0","5","300","10.20.1.11","alfo") Function: oid() 1. parameter: # of OID to get 2. parameter: Cache time in seconds 3. parameter: Negative cache time in minutes 4. parameter: Device IP 5. parameter: SNMP profile

Functions and Functions Description

Label 2 Label source is a function call: [alfo_capacity()] Custom function Additional challenge: Required information not directly available by SNMP ALFO MIB will provide combined number code for operational mode (Ch. BW and Modulation) Using nested if statements for creating output

Create new Function FMS www.fmsweb.de

Label 2 individual function if (oid_raw("1.3.6.1.4.1.3373.12.8.4.0")=13, " Bandwidth: 100MBit/s (FD) Channel: 28MHz Modulation: 32QAM ",if (oid_raw("1.3.6.1.4.1.3373.12.8.4.0")=8, " Bandwidth: 34MBit/s (FD) Channel: 14MHz Modulation: 16QAM ",if (oid_raw("1.3.6.1.4.1.3373.12.8.4.0")=11, " Bandwidth: 68MBit/s (FD) Channel: 28MHz Modulation: 16QAM ","unknown")))

Device Types Example#3 VMware Server and ESX

VMware server 2 and ESX 3 Separate types for different products Even better visualization with different icons Web access and tools

TCP Probe VMware Server 2 and ESX3 have different management ports Use TCP probes for identification VMware Server2 Ports: 902, 8222, 8333 VMware ESX 3 Ports: 902

VMware Console Probe (TCP, connect only) FMS www.fmsweb.de

VMware Server GUI Probe (TCP wo/w connect) FMS www.fmsweb.de

Device Type Identification VMWare Type Server 2 ESX Server Require 8333 902 Allow 902 8222 8333 902

Result of Discover FMS www.fmsweb.de

Device Type > General > URL Change Default URL: http > https Port 80 > 8333 URL will be available as variable: [DeviceType.Url]

DeviceType > General > URL FMS www.fmsweb.de

Add desired functionality 1. Create tool in the tools section 2. Select appropriate device types (can not be changed afterwards) 3. Will appear in the tools menus

Create new tool FMS www.fmsweb.de

Custom Tools (Webbased) Browse datastore [DeviceType.Url]/folder?dcPath=hadatacenter Download infrastructure client [DeviceType.Url]/client/VMwareviclient.exe [DeviceType.Url] has been adapted for Server2 Server 2:[DeviceType.Url] = https://url:8333 ESX 3: [DeviceType.Url] = http://url

Webbased Tools FMS www.fmsweb.de

Custom Tools (Applications) Launch VI client: "C:\Programme\VMware\Infrastructure\Virtual Infrastructure Client\Launcher\VpxClient.exe" s [Device.FirstAddress] Launch VI client and log in: "C:\Programme\VMware\Infrastructure\Virtual Infrastructure Client\Launcher\VpxClient.exe" s [Device.FirstAddress] u [Device.UserName] p [Device.Password]

Launch VI client in Detail FMS www.fmsweb.de

Finished: VMware Server 2 Device Type

Using tool Log into VI Client FMS www.fmsweb.de

Thank you for listening FMS Internetservice, www.fmsweb.de info@fmsweb.de, Phone: +49 761 2926500 copyright FMS 2011