School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management

Size: px
Start display at page:

Download "School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management"

Transcription

1 School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management Lab 3: Simple Network Management Protocol (SNMP) Operations Objective To become familiar with basic SNMP operations by configuring and managing a desktop computer and a CICSO router. Background SNMP Service Management Windows XP Windows XP can be configured to be managed using SNMP commands. The workstations in the lab have the SNMP service installed to allow SNMP management. To start it, go to the Services Control Panel of Windows XP by choosing the Start -> Settings -> Control Panel -> Administrative Tools -> Services. Start the SNMP and SNMP Trap Service. Once the SNMP Service is started it is possible to configure it to allow an SNMP agent to get access to the system. This is done by opening the properties window of the SNMP Service and setting the Agent, Trap, and Security Settings. Below you see a screen dump of the Agent window of the SNMP Service properties task. You need to set these values to any name and location you want. Services types are listed at the bottom of the panel. They provide information

2 that can be stored in the MIB-2 variables in the System Group of MIB-2. End-to-End refers to TCP MIB variables, Internet to IP MIB and Datalink to Ethernet Hardware addresses. The Security tab specifies what the accepted community names and their appropriate access rights to the MIB variables are. The figure below and to the left shows the community name public having READ ONLY access. The public community is a default. You should add the tei_admin community for READ WRITE access. The Traps tab specifies where the traps captured by SNMP are to be sent. This community will be the name used by the OS in trap messages. The name must be the same as that configured by the receiving Management Station for receiving trap messages. The trap destinations box will reflect the IP address where the NMS is hosted. Add to this the mon_admin community name by choosing Add to list button and set the destination to the IP address of your machine or WinSNMP WinSNMP is a set of APIs for SNMP management for the Windows OS. It is installed when the SNMP service is installed. It can be used to develop an SNMP agent or client. The SNMPUtil and SNMPUtilg executables use it. SNMPUtilg The SNMPUtilg is a windows based SNMP interface for getting and setting SNMP parameters. Procedure

3 Execute the SNMPUtilg program that should be located on the C:\Program Files\SNMP folder. If not, you can download it from the lab s website. Run it and you will see something like this: Configure the window just like you see above and proceed to answer the following questions. 1. Which object identifier is displayed as the default? Hint: execute the command once, then execute the command again and you should see the next value in the MIB. This should be the Object Identifier. Go to the web site and determine which enterprise does this object belong to. 2. Switch the SNMP Function to execute to the value Get the value of the current OID. Type in the system.sysdescr OID and execute this command. What occurs when the OID is ? Why does this error occur 3. What OID value would you enter to get the system.syscontact? Hint: You can determine this by looking at the system group layout in the MIT. Enter this value and execute the command. What is the result? 4. If you walk the tree down from this level how many objects do you get in the system group? What is the object(s) name and value? What will be the next object after the last value of the system object is displayed?

4 5. What OID entry value would you enter to try to get the workstations IP address mask? There are 2 possible answers here depending on whether you use the local IP address or the IP address of your workstation. What is the OID value you used? SNMP Traps SNMP Traps can also be captured with the proper client software. Download snmputil.exe from the lab s website and place it in the SNMP folder. Open a DOS window and execute the command snmputil trap. This will run snmputil in a mode where it is capturing traps that are sent to it. Recall that the SNMP service was set for sending traps if a NMS tries to access it with the wrong password. 6. From the SNMPUtilg program change the community name to a value other than public. Try to access the sysdescr object values What is the output in the snmputil window? Where in the process did you specify where the traps were going to be sent? Change the community name to tei_admin and try the query again. You should not get an error this time. Using an NMS As you can tell SNMPUtilg analyzer is not a powerful tool since it only supports the reading of SNMP values and it is necessary to know the object IDs. A better tool is the Meterware NMS tool. Launch this application from the desktop and add your workstation as a device. This can be done by choosing in the Edit menu of Meterware the New Device option. This will pop up a window like below where it is necessary to fill in the device name, IP addresse, SNMP Level, etc. Fill the values in this window as shown and press the resolve button to commence polling.

5 7. When the HiFn analyzer shows a green up arrow the workstation is being polled. Meterware uses a graphical MIB browser that simplifies the viewing and setting of MIB parameters. Determine the MAC address of your interface card by opening the MIB browser window from the Tools menu and browsing to the interfaces object. What is the name of the object that you would choose to get the interfaces MAC address? What is your MAC address? You get the values of the objects by pressing on the icon button that looks like a traffic light. Why is there more than 1 interface? Look at the contents of the system.syscontact object. Set this value to Your Name by double clicking on the value of the MIB Variable Instance and typing in the string that corresponds to your name. At this point you are ready to explore connecting to a router on your own private network. We will perform some simple connections and later explore some more detailed Network Monitoring. Configure the following simple network shown below: Router /24 F0/0: /24 Make certain that the PC can PING the router and vice-versa. Configuring SNMP in the CISCO 2600 Router The router needs to be configured to allow the PC to access the Network Management Information. The first step is to create an access list for the router using the following command. Router(config)# access-list 1 permit This command creates an access list that permits host to access the router. Why is the mask is ? The SNMP configuration begins by specifying the SNMP host access rights and community name: Router(config)# snmp-server community tei_admin RW 1 This command specifies the community name and the MIB access as well as added security level using the host access list. In order to enable trap messages to be sent the following command has to be entered: Router(config)# snmp-server host rmon_admin snmp

6 This states that host will be the recipient of traps generated by the router and the trap community name will be rmon_admin. You can now start up the HiFn Analyzer and add to the list of devices the routers F0/0 IP address. Use the tei_admin community name as follows: When you press the resolve button the Analyzer should resolve the MAC address and IP address and then press OK. The status of the router should come up to a green arrow. 9. Open the MIB Browser and take a look at the interface status by viewing the ifadminstatus object as shown in the screenshot on the next page. How many interfaces do you see? How can you determine which interfaces these are? List them. 10. The integer values of the status correspond to the following 1=UP 2=DOWN. What is the status of if3? Now set the value of the ifadmin3 to 1. What happened? Look at the Hyperterminal connection you have. What occurred to the state of f0/0? 11. In order to appreciate the composition of the SNMP messages, run Ethereal and capture an SNMP GET request. Show the screen dump of this message. What transport protocol is used by SNMP? What port is the GET request sent to? 12. Use the Hifn MIB browser to capture a query for the values of the ipaddrtable of the router. Show a screen dump of the values and explain the name of the MIB Variable Instance. Which object is the index? Explain how the variable instance values are lexicographically ordered.

7

School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management. Lab 4: Remote Monitoring (RMON) Operations

School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management. Lab 4: Remote Monitoring (RMON) Operations School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management Lab 4: Remote Monitoring (RMON) Operations Objective To become familiar with basic RMON operations, alarms,

More information

In this lab you will explore the Windows XP Firewall and configure some advanced settings.

In this lab you will explore the Windows XP Firewall and configure some advanced settings. 16.3.2 Lab: Configure Windows XP Firewall Print and complete this lab. In this lab you will explore the Windows XP Firewall and configure some advanced settings. Recommended Equipment Two computers directly

More information

FMUX04 SNMP Tutorial

FMUX04 SNMP Tutorial FMUX04 SNMP Tutorial Abstract: This tutorial will guide the new comer on how to configure the FMUX04 with SNMP option for management and how to access the enterprise MIB for monitoring Optical signal/ber

More information

10.3.1.10 Lab - Configure a Windows XP Firewall

10.3.1.10 Lab - Configure a Windows XP Firewall 5.0 10.3.1.10 Lab - Configure a Windows XP Firewall Print and complete this lab. In this lab, you will explore the Windows XP Firewall and configure some advanced settings. Recommended Equipment Step 1

More information

10.3.1.9 Lab - Configure a Windows Vista Firewall

10.3.1.9 Lab - Configure a Windows Vista Firewall 5.0 10.3.1.9 Lab - Configure a Windows Vista Firewall Print and complete this lab. In this lab, you will explore the Windows Vista Firewall and configure some advanced settings. Recommended Equipment Step

More information

10.3.1.8 Lab - Configure a Windows 7 Firewall

10.3.1.8 Lab - Configure a Windows 7 Firewall 5.0 10.3.1.8 Lab - Configure a Windows 7 Firewall Print and complete this lab. In this lab, you will explore the Windows 7 Firewall and configure some advanced settings. Recommended Equipment Step 1 Two

More information

Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device

Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device SNMPc supports many devices straight out of the box. Its generic support for device classes such as Switches, Routers and Servers

More information

Cisco Cable DVB/DAVIC Management Program

Cisco Cable DVB/DAVIC Management Program CHAPTER 3 This chapter describes the supplied by Cisco for configuring and monitoring the Cisco DVB CAR100. It includes the following sections: Introducing the Minimum PC Requirements for the Installing

More information

a) Network connection problems (check these for existing installations)

a) Network connection problems (check these for existing installations) How do I resolve issues with a Client not connecting to the Best Practice server instance? This FAQ is intended to answer common questions about resolving issues with a Best Practice client not connecting

More information

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs Tasks: 1 (10 min) Verify that TCP/IP is installed on each of the computers 2 (10 min) Connect the computers together via a switch 3 (10 min)

More information

Lab 8.3.2 Conducting a Network Capture with Wireshark

Lab 8.3.2 Conducting a Network Capture with Wireshark Lab 8.3.2 Conducting a Network Capture with Wireshark Objectives Perform a network traffic capture with Wireshark to become familiar with the Wireshark interface and environment. Analyze traffic to a web

More information

CREATING AN IKE IPSEC TUNNEL BETWEEN AN INTERNET SECURITY ROUTER AND A WINDOWS 2000/XP PC

CREATING AN IKE IPSEC TUNNEL BETWEEN AN INTERNET SECURITY ROUTER AND A WINDOWS 2000/XP PC CREATING AN IKE IPSEC TUNNEL BETWEEN AN INTERNET SECURITY ROUTER AND A WINDOWS 2000/XP PC 1 Introduction Release date: 11/12/2003 This application note details the steps for creating an IKE IPSec VPN tunnel

More information

Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1.

Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1. Avaya Solution & Interoperability Test Lab Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1.0 Abstract These Application

More information

1 crossover cable. the PCs. network

1 crossover cable. the PCs. network King Abdul-Aziz University Faculty of Computing and Information Technology Department of Information Technology Computer Networks CPIT370 Lab#2: Wired Peer to Peer network and star topology using a switch

More information

Virtual Office Remote Installation Guide

Virtual Office Remote Installation Guide Virtual Office Remote Installation Guide Table of Contents VIRTUAL OFFICE REMOTE INSTALLATION GUIDE... 3 UNIVERSAL PRINTER CONFIGURATION INSTRUCTIONS... 12 CHANGING DEFAULT PRINTERS ON LOCAL SYSTEM...

More information

SNMP Protocol for Easy Network Management

SNMP Protocol for Easy Network Management ACTi Knowledge Base Category: Educational Note Sub-category: Application Model: ACM Series TCM Series ACD-2100 TCD-2100 TCD-2500 Firmware: Software: N/A Author: Wells.Wei Published: 2010/10/22 Reviewed:

More information

Lab 8.4.2 Configuring Access Policies and DMZ Settings

Lab 8.4.2 Configuring Access Policies and DMZ Settings Lab 8.4.2 Configuring Access Policies and DMZ Settings Objectives Log in to a multi-function device and view security settings. Set up Internet access policies based on IP address and application. Set

More information

ECView Pro Network Management System. Installation Guide. www.edge-core.com

ECView Pro Network Management System. Installation Guide. www.edge-core.com ECView Pro Network Management System Installation Guide www.edge-core.com INSTALLATION GUIDE ECVIEW PRO NETWORK MANAGEMENT SYSTEM SNMP-Based Network Management Software for Windows SW6102 E102010-CS-R01

More information

This guide provides instructions on how to configure SNMP feature on Yealink IP phones and test SNMP feature using a free SNMP test tool.

This guide provides instructions on how to configure SNMP feature on Yealink IP phones and test SNMP feature using a free SNMP test tool. This guide provides instructions on how to configure SNMP feature on Yealink IP phones and test SNMP feature using a free SNMP test tool. The configurations described in this guide take the Yealink SIP-T28P

More information

Network Monitoring with SNMP

Network Monitoring with SNMP Network Monitoring with SNMP This paper describes how SNMP is used in WhatsUp- Professional and provides specific examples on how to configure performance, active, and passive monitors. Introduction SNMP

More information

Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5

Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5 Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5 Objectives Part 1: Configure CCP Access for Routers Enable HTTP/HTTPS server. Create a user account with privilege level 15.

More information

Freshservice Discovery Probe User Guide

Freshservice Discovery Probe User Guide Freshservice Discovery Probe User Guide 1. What is Freshservice Discovery Probe? 1.1 What details does Probe fetch? 1.2 How does Probe fetch the information? 2. What are the minimum system requirements

More information

Quick Installation Guide Network Management Card

Quick Installation Guide Network Management Card Rev.1.1 www.cyberpowersystems.com Quick Installation Guide Network Management Card Intelligent Network Management Card allows UPS to be managed, monitored, and configured via SNMP Card Configuration Tool

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

Technical Note SNMP Interface

Technical Note SNMP Interface Technical Note SNMP Interface Introduction This document describes the SNMP Interface provided with InduSoft Web Studio (IWS) and CEView. Simple Network Management Protocol (SNMP) is a popular protocol

More information

Lotus Notes 6.x Client Installation Guide for Windows. Information Technology Services. CSULB

Lotus Notes 6.x Client Installation Guide for Windows. Information Technology Services. CSULB The goal of this document This document was created by the Information Technology Services department to assist the Lotus Notes Coordinators in the successful installation of Lotus Notes release 6 (R6)

More information

HYPERLINK Internet PC setup guide. HYPERLINK Internet support helpdesk at 1-866-302-5525.

HYPERLINK Internet PC setup guide. HYPERLINK Internet support helpdesk at 1-866-302-5525. HYPERLINK Internet support helpdesk at 1-866-302-5525. Congratulations on your new residence and welcome to HYPERLINK Internet service. In a few short moments you will be connected to one of the fastest

More information

Lab 8.4.2 Configuring Access Policies and DMZ Settings

Lab 8.4.2 Configuring Access Policies and DMZ Settings Lab 8.4.2 Configuring Access Policies and DMZ Settings Objectives Log in to a multi-function device and view security settings. Set up Internet access policies based on IP address and application. Set

More information

freesshd SFTP Server on Windows

freesshd SFTP Server on Windows freesshd SFTP Server on Windows Configuration Steps: Setting up the Bridgestone User ID... 2 Setup the freesshd Server... 3 Login as the Bridgestone User ID using WinSCP... 5 Create Default Bridgestone

More information

Installation and Connection Guide to the simulation environment GLOBAL VISION

Installation and Connection Guide to the simulation environment GLOBAL VISION Installation and Connection Guide to the simulation environment GLOBAL VISION Hardware and Software Requirements The following hardware specification is recommended for client machines: 2 GHz Pentium class

More information

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 - Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors

More information

How to Setup and Connect to an FTP Server Using FileZilla. Part I: Setting up the server

How to Setup and Connect to an FTP Server Using FileZilla. Part I: Setting up the server How to Setup and Connect to an FTP Server Using FileZilla The ability to store data on a server and being able to access the data from anywhere in the world has allowed us to get rid of external flash

More information

16.4.3 Lab: Data Backup and Recovery in Windows XP

16.4.3 Lab: Data Backup and Recovery in Windows XP 16.4.3 Lab: Data Backup and Recovery in Windows XP Introduction Print and complete this lab. In this lab, you will back up data. You will also perform a recovery of the data. Recommended Equipment The

More information

DocuPrint C3290 FS Features Setup Guide

DocuPrint C3290 FS Features Setup Guide DocuPrint C3290 FS Features Setup Guide Adobe and PostScript are trademarks of Adobe Systems Incorporated in the United States and/or other countries. Apple, Bonjour, ColorSync, EtherTalk, Macintosh, and

More information

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide

MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide MULTIFUNCTIONAL DIGITAL SYSTEMS Network Fax Guide 2009 KYOCERA MITA Corporation All rights reserved Preface Thank you for purchasing Multifunctional Digital Color Systems. This manual explains the instructions

More information

From a Finder window choose Applications (shown circled in red) and then double click the Tether icon (shown circled in green).

From a Finder window choose Applications (shown circled in red) and then double click the Tether icon (shown circled in green). From a Finder window choose Applications (shown circled in red) and then double click the Tether icon (shown circled in green). You will be presented with a dialog box asking for you to enter an ad-hoc

More information

1 PC to WX64 direction connection with crossover cable or hub/switch

1 PC to WX64 direction connection with crossover cable or hub/switch 1 PC to WX64 direction connection with crossover cable or hub/switch If a network is not available, or if it is desired to keep the WX64 and PC(s) completely separated from other computers, a simple network

More information

SSL VPN Service. Once you have installed the AnyConnect Secure Mobility Client, this document is available by clicking on the Help icon on the client.

SSL VPN Service. Once you have installed the AnyConnect Secure Mobility Client, this document is available by clicking on the Help icon on the client. Contents Introduction... 2 Prepare Work PC for Remote Desktop... 4 Add VPN url as a Trusted Site in Internet Explorer... 5 VPN Client Installation... 5 Starting the VPN Application... 6 Connect to Work

More information

Crown Field Support Engineering

Crown Field Support Engineering Crown Field Support Engineering Issue Date: 17 January 2014 Ref. No: GEN Go Online #0002 Subject: Basic Go Online w/ Audio Architect (Network Based Product) Applicability: The following step by step instructions

More information

NAS 107 Introduction to Control Center

NAS 107 Introduction to Control Center NAS 107 Introduction to Control Center Perform basic management on your NAS using Control Center A S U S T O R C O L L E G E COURSE OBJECTIVES Upon completion of this course you should be able to: 1. Use

More information

Scan to E-mail Quick Setup Guide

Scan to E-mail Quick Setup Guide Xerox WorkCentre M118i Scan to E-mail Quick Setup Guide 701P42574 This guide provides a quick reference for setting up the Scan to E-mail feature on the Xerox WorkCentre M118i. It includes procedures for:

More information

Super Pro Net TM Network Key Installation and Operation

Super Pro Net TM Network Key Installation and Operation March 4, 2015 Super Pro Net TM Network Key Installation and Operation Installation Overview RoadEng software can be protected against unlicensed use on a network with SafeNet s Super Pro Net TM hardware

More information

10.3.1.6 Lab - Data Backup and Recovery in Windows XP

10.3.1.6 Lab - Data Backup and Recovery in Windows XP 5.0 10.3.1.6 Lab - Data Backup and Recovery in Windows XP Introduction Print and complete this lab. In this lab, you will back up data. You will also perform a recovery of the data. Recommended Equipment

More information

Network Adapter Configuration Guide for Macintosh OS X

Network Adapter Configuration Guide for Macintosh OS X Network Adapter Configuration Guide for Macintosh OS X Hardware and Driver Installation With the Mac OS X correctly installed on your computer, installing an Asanté network adapter is easy. Simply follow

More information

Scheduling Automated Outlet Control Using FineSNMPSet with Sentry Switched Power Distribution Units

Scheduling Automated Outlet Control Using FineSNMPSet with Sentry Switched Power Distribution Units Scheduling Automated Outlet Control Using FineSNMPSet with Sentry Switched Power Distribution Units This documents the following topics: Purpose Overview FineSNMPSet Free-Ware Utility Windows Scheduled

More information

Elluminate Live! Access Guide. Page 1 of 7

Elluminate Live! Access Guide. Page 1 of 7 This guide is provided to Elluminate Live! users to assist them to make a successful connection to an Elluminate Live! session through a proxy firewall. In some cases settings discussed in this document

More information

How To Industrial Networking

How To Industrial Networking How To Industrial Networking Prepared by: Matt Crites Product: Date: April 2014 Any RAM or SN 6xxx series router Legacy firmware 3.14/4.14 or lower Subject: This document provides a step by step procedure

More information

StarMOBILE Network Configuration Guide. A guide to configuring your StarMOBILE system for networking

StarMOBILE Network Configuration Guide. A guide to configuring your StarMOBILE system for networking StarMOBILE Network Configuration Guide A guide to configuring your StarMOBILE system for networking INTRODUCTION... 3 BEFORE YOU BEGIN... 3 1) CONFIRM YOU HAVE THE LATEST SOFTWARE... 3 2) INSTALL THE STARMOBILE

More information

Pre-lab and In-class Laboratory Exercise 10 (L10)

Pre-lab and In-class Laboratory Exercise 10 (L10) ECE/CS 4984: Wireless Networks and Mobile Systems Pre-lab and In-class Laboratory Exercise 10 (L10) Part I Objectives and Lab Materials Objective The objectives of this lab are to: Familiarize students

More information

Computer Networks I Laboratory Exercise 1

Computer Networks I Laboratory Exercise 1 Computer Networks I Laboratory Exercise 1 The lab is divided into two parts where the first part is a basic PC network TCP/IP configuration and connection to the Internet. The second part is building a

More information

mystanwell.com Installing Citrix Client Software Information and Business Systems

mystanwell.com Installing Citrix Client Software Information and Business Systems mystanwell.com Installing Citrix Client Software Information and Business Systems Doc No: 020/12 Revision No: Revision Date: Page: 1 of 16 Contents Overview... 3 1. Microsoft Internet Explorer... 3 2.

More information

Xerox Multifunction Devices. Verify Device Settings via the Configuration Report

Xerox Multifunction Devices. Verify Device Settings via the Configuration Report Xerox Multifunction Devices Customer Tips March 15, 2007 This document applies to these Xerox products: X WC 4150 X WCP 32/40 X WCP 35/45/55 X WCP 65/75/90 X WCP 165/175 X WCP 232/238 X WCP 245/255 X WCP

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

Guide to Installing BBL Crystal MIND on Windows 7

Guide to Installing BBL Crystal MIND on Windows 7 Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP

More information

PigCHAMP Knowledge Software. Enterprise Edition Installation Guide

PigCHAMP Knowledge Software. Enterprise Edition Installation Guide PigCHAMP Knowledge Software Enterprise Edition Installation Guide Enterprise Edition Installation Guide MARCH 2012 EDITION PigCHAMP Knowledge Software 1531 Airport Rd Suite 101 Ames, IA 50010 Phone (515)

More information

Network Power Manager. User Manual

Network Power Manager. User Manual Network Power Manager User Manual Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 1. Introduction The PDU is an Internet ready device

More information

Special Note Ethernet Connection Problems and Handling Methods (CS203 / CS468 / CS469)

Special Note Ethernet Connection Problems and Handling Methods (CS203 / CS468 / CS469) Special Note Connection Problems and Handling Methods (CS203 / CS468 / CS469) Sometimes user cannot find the RFID device after installing the CSL Demo App and the RFID reader is connected. If user cannot

More information

Lab 4.4.8a Configure a Cisco GRE over IPSec Tunnel using SDM

Lab 4.4.8a Configure a Cisco GRE over IPSec Tunnel using SDM Lab 4.4.8a Configure a Cisco GRE over IPSec Tunnel using SDM Objective Scenario Topology In this lab, the students will complete the following tasks: Prepare to configure Virtual Private Network (VPN)

More information

Network Monitoring with SNMP

Network Monitoring with SNMP Network Monitoring with SNMP This document describes how SNMP is used in WhatsUp Gold v11 and provides examples on how to configure performance, active, and passive monitors. Introduction SNMP (Simple

More information

Immotec Systems, Inc. SQL Server 2005 Installation Document

Immotec Systems, Inc. SQL Server 2005 Installation Document SQL Server Installation Guide 1. From the Visor 360 installation CD\USB Key, open the Access folder and install the Access Database Engine. 2. Open Visor 360 V2.0 folder and double click on Setup. Visor

More information

BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1

BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 BLADE OS BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 Part Number: BMD00116, August 2009 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.net Copyright 2009

More information

Initial Setup of Microsoft Outlook 2011 with IMAP for OS X Lion

Initial Setup of Microsoft Outlook 2011 with IMAP for OS X Lion Initial Setup of Microsoft Outlook Concept This document describes the procedures for setting up the Microsoft Outlook email client to download messages from Google Mail using Internet Message Access Protocol

More information

How To Understand and Configure Your Network for IntraVUE

How To Understand and Configure Your Network for IntraVUE How To Understand and Configure Your Network for IntraVUE Summary This document attempts to standardize the methods used to configure Intrauve in situations where there is little or no understanding of

More information

IsItUp Quick Start Manual

IsItUp Quick Start Manual IsItUp - When you need to know the status of your network Taro Software Inc. Website: www.tarosoft.com Telephone: 703-405-4697 Postal address: 8829 110th Lane, Seminole Fl, 33772 Electronic mail: Contact1@tarosoft.com

More information

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer. Dexter is a network device using the Ethernet protocol to connect and communicate with other devices on the network: Computers, routers, DHCP servers. Thus you have to setup your Dexter and your network

More information

EINTE LAB EXERCISES LAB EXERCISE #5 - SIP PROTOCOL

EINTE LAB EXERCISES LAB EXERCISE #5 - SIP PROTOCOL EINTE LAB EXERCISES LAB EXERCISE #5 - SIP PROTOCOL PREPARATIONS STUDYING SIP PROTOCOL The aim of this exercise is to study the basic aspects of the SIP protocol. Before executing the exercise you should

More information

Simple Network Management Protocol

Simple Network Management Protocol CS 556 - Networks II Internet Teaching Lab (MCS B-24) Simple Network Mgmt Protocol (SNMP) Simple Network Management Protocol What you will learn in this lab: Details of the SNMP protocol. Contents of a

More information

SSL VPN Support Guide

SSL VPN Support Guide P a g e 1 SSL VPN Support Guide Revision date: 5/4/10 P a g e 2 Table of Contents Before calling the Support Desk..pg 3 What the Support Desk can assist users with. pg 4 Instructions for PC users (Internet

More information

Lab 7.3.1 Editing the HOSTS File in Windows

Lab 7.3.1 Editing the HOSTS File in Windows Lab 7.3.1 Editing the HOSTS File in Windows Objective Edit the local HOSTS file on a Windows PC to map a name to an IP address for easier identification. Background / Preparation You are employed at an

More information

Elluminate Live! Access Guide. Page 1 of 7

Elluminate Live! Access Guide. Page 1 of 7 This guide is provided to Elluminate Live! users to assist them to make a successful connection to an Elluminate Live! session through a proxy firewall. In some cases settings discussed in this document

More information

Installation Guide for Windows May 2016

Installation Guide for Windows May 2016 Installation Guide for Windows May 2016 1 Welcome to KITE Client Software for Windows Note: The KITE Client software is supported for both 32-bit and 64-bit Windows computers. The Kansas Interactive Testing

More information

Setting Up Your FTP Server

Setting Up Your FTP Server Requirements:! A computer dedicated to FTP server only! Linksys router! TCP/IP internet connection Steps: Getting Started Configure Static IP on the FTP Server Computer: Setting Up Your FTP Server 1. This

More information

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7 Contents Introduction--1 Product definition 1 Implementing SNMP 2 Integrating SNMP into the user interface 3 Components of OPC SNMP Gateway 4 How to Obtain an OPC License--5 Creating a System Code 5 Entering

More information

Using SolarWinds Orion for Cisco Assessments

Using SolarWinds Orion for Cisco Assessments Using SolarWinds Orion for Cisco Assessments Cisco Network Assessments Registering Your Assessment... 1 Installing SolarWinds Orion Network Performance Monitor... 1 Discovering Your Network... 1 Polling

More information

Installing Remote Desktop Connection

Installing Remote Desktop Connection SETTING UP YOUR REMOTE DESKTOP This section will assist you in setting you Remote Desktop Connection. This will allow you to create an icon for easy access to your virtual desktop. DISCLAIMER: All images

More information

SecureIT Plus Firewall Features and Functionality

SecureIT Plus Firewall Features and Functionality SecureIT Plus Firewall Features and Functionality Iowa Network Services SecureIT Plus Firewall Page 1 of 11 1.1 Enabling Firewall 1.1.1 Main Settings Once you have installed the firewall and have rebooted

More information

Remote Connectivity to XV, XP and epro units running Visual Designer

Remote Connectivity to XV, XP and epro units running Visual Designer Intro Remote connectivity is one of the major features of Visual Designer and our new operator interface hardware platforms running that software. The ability to monitor, troubleshoot, edit and administer

More information

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc. Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide Version 5.0 rev 1 Advantech Corp., Ltd. Table of Contents BwSNMP Advantech WebAccess to SNMP Agent (Simple

More information

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS supports native TCP/IP polling for the SPS2000 cash register. It is recommended users have the register updated

More information

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout

More information

User Manual. 3CX VOIP client / Soft phone Version 6.0

User Manual. 3CX VOIP client / Soft phone Version 6.0 User Manual 3CX VOIP client / Soft phone Version 6.0 Copyright 2006-2008, 3CX ltd. http:// E-mail: info@3cx.com Information in this document is subject to change without notice. Companies names and data

More information

Wazza s QuickStart 1. Leopard Server - Install & Configure DNS

Wazza s QuickStart 1. Leopard Server - Install & Configure DNS Wazza s QuickStart 1. Leopard Server - Install & Configure DNS About this Document This document is the first in a series of documents describing the process of installing and configuring a Mac OS X 10.5

More information

Steltronic Focus. Main Desk Internet connection

Steltronic Focus. Main Desk Internet connection Steltronic Focus Main Desk Steltronic S.p.A. Via Artigianale 34, 25082 Botticino Sera Brescia - Italy Tel: +39 030 2190811 fax: +39 030 2190798 Service: + 39 030 2190830 http: www.steltronic.com Service:

More information

MiraCosta College now offers two ways to access your student virtual desktop.

MiraCosta College now offers two ways to access your student virtual desktop. MiraCosta College now offers two ways to access your student virtual desktop. We now feature the new VMware Horizon View HTML access option available from https://view.miracosta.edu. MiraCosta recommends

More information

Network Monitoring Assignments

Network Monitoring Assignments Network Monitoring Assignments Cyril Soldani INFO0056 11th February 2015 1 Outline 1 Introduction 2 Using SNMP Tools 3 Web-based SNMP Browser 4 Agenda 2 Network Management and Security Assignments There

More information

Pandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide

Pandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide Pandora FMS 3.0 Quick User's Guide April 27th, 2009 1 Contents How to monitor a network computer/device?...3 Concepts...3 What's an agent?...3 What's a module?...3 Data transfer modes...3 What is an alert?...3

More information

How to Install and use Windows XP Mode and Windows Virtual PC in Windows 7 for older 32 bit only Applications

How to Install and use Windows XP Mode and Windows Virtual PC in Windows 7 for older 32 bit only Applications How to Install and use Windows XP Mode and Windows Virtual PC in Windows 7 for older 32 bit only Applications Important Applies to Windows 7 Professional, Ultimate, Enterprise As of April 8, 2014, technical

More information

How to Remotely View Security Cameras Using the Internet

How to Remotely View Security Cameras Using the Internet How to Remotely View Security Cameras Using the Internet Introduction: The ability to remotely view security cameras is one of the most useful features of your EZWatch Pro system. It provides the ability

More information

User's Manual. Intego Remote Management Console User's Manual Page 1

User's Manual. Intego Remote Management Console User's Manual Page 1 User's Manual Intego Remote Management Console User's Manual Page 1 Intego Remote Management Console for Macintosh 2007 Intego, Inc. All Rights Reserved Intego, Inc. www.intego.com This manual was written

More information

NetBrain Discovery Appliance Manual

NetBrain Discovery Appliance Manual NetBrain Discovery Appliance Manual NetBrain Technologies, Inc. 2009-07-20-1 - Table of Contents 1. Overview... 4 2. Installation... 5 2.1 Installation Software... 5 2.1.1 Install ActivePerl... 5 2.1.2

More information

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel +32 16 317 411 Fax +32 16 207 164 http://www.option.com Page 1 of 14

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel +32 16 317 411 Fax +32 16 207 164 http://www.option.com Page 1 of 14 Page 1 of 14 ! " #!"#$ % &&' Page 2 of 14 1 INTRODUCTION One of the highly desirable features of the GlobeSurfer III device is the ability to network together Printers and External Hard Disk drives (aka

More information

Joining an XP workstation to a domain Version 1.00

Joining an XP workstation to a domain Version 1.00 Joining an XP workstation to a domain Version 1.00 All Windows XP Professional workstations need to be joined to a domain to function as part of the domain security environment. Need to Know TM 1. To join

More information

Connecting to Remote Desktop Windows Users

Connecting to Remote Desktop Windows Users Connecting to Remote Desktop Windows Users How to log into the College Network from Home 1. Start the Remote Desktop Connection For Windows XP, Vista and Windows 7 this is found at:- Star t > All Programs

More information

CCNA Discovery 4.0.3.0 Networking for Homes and Small Businesses Student Packet Tracer Lab Manual

CCNA Discovery 4.0.3.0 Networking for Homes and Small Businesses Student Packet Tracer Lab Manual 4.0.3.0 Networking for Homes and Small Businesses Student Packet Tracer Lab Manual This document is exclusive property of Cisco Systems, Inc. Permission is granted to print and copy this document for non-commercial

More information

Use this guide if you are no longer able to scan to Sharpdesk. Begin with section 1 (easiest) and complete all sections only if necessary.

Use this guide if you are no longer able to scan to Sharpdesk. Begin with section 1 (easiest) and complete all sections only if necessary. Use this guide if you are no longer able to scan to Sharpdesk Instructions: Begin with section 1 (easiest) and complete all sections only if necessary. 1 Section 1 Complete pages 3-5. Scan to the desired

More information

Application Note 8: TrendView Recorders DCOM Settings and Firewall Plus DCOM Settings for Trendview Historian Server

Application Note 8: TrendView Recorders DCOM Settings and Firewall Plus DCOM Settings for Trendview Historian Server Application Note 8: TrendView Recorders DCOM Settings and Firewall Plus DCOM Settings for Trendview Historian Server DCOM Configuration Introduction This document is intended to provide a check-list of

More information

Campus VPN. Version 1.0 September 22, 2008

Campus VPN. Version 1.0 September 22, 2008 Campus VPN Version 1.0 September 22, 2008 University of North Texas 1 9/22/2008 Introduction This is a guide on the different ways to connect to the University of North Texas Campus VPN. There are several

More information