Datacenter Infrastructure Management: Orchestrating Space, Power and Cooling
|
|
|
- Willa Porter
- 10 years ago
- Views:
Transcription
1 Datacenter Infrastructure Management: Orchestrating Space, Power and Cooling Athens, April 2014 Dimitris IOANNOU Sales Manager, E&S Services Schneider Electric
2 What is the Greatest Data Center Challenge you Face? 654 respondents % Data center space, power and/or cooling Aligning activities with the business Modernizing our legacy systems Developing a private / public cloud strategy Making do with a smaller budget Managing the rate of technology change Virtualization Finding / retaining talent Determining how to source IT services Jay Pulz: DCIM: New Tools to Monitor, Manage and Control Power, Gartner, December
3 Data Center Management Challenges Data Center Availability Business Efficiency 3
4 The Data Center Infrastructure Breakout Facility Responsible for critical power and cooling supplies IT Responsible for IT operations Applications/Virtualization/Cloud Compute Power/Storage Space/Network Access Servers/Storage Units/Networking Equipment Critical Power & Cooling Building/Security/Physical Space 4
5 POWER COOLING SPACE 5
6 POWER COOLING SPACE 6
7 Data Center Power Fluctuation PAST PRESENT FUTURE DC Capacity DC Capacity 7
8 Power Variation at the SERVER level PowerEdge R720 Intel Xeon E5-2670, 2.6 GHz 16 cores, 2 chips, 8 cores/chip 6 x 4096 MB 1 x 100GB SATA SSD Nameplate: 495W Real Power Variations: W Optimal performance: 70% CPU 159W Efficiency gain (60% vs 10%): x 3 Source: 8
9 Data Center Power Capacity Planning Worst Case Design Planning 21 servers per rack (Cloud/HPC) 20 racks per POD 8 PODs in the Room PUE = 1.54 Nameplate Full Performance Optimal Performance Server Rack POD Room Facility 495W 10.4kW 208kW 1.67MW 2.57MW 231W 4.9kW 98kW 777kW 1.20MW 159W 3.4kW 67kW 535kW 823MW 9
10 My Rack Capacity? rpdu: 230V = 3.68kW rpdu readings: Rack 3: 2.4kW Rack 5: 1.1kW Where would you install the next server? 10
11 Understanding your cooling dynamics Temperature threshold violation!!! Humidity threshold violation!!! What does it all mean? Cause Effect Rapid increase in hot aisle temperature Fan speed alert 11
12 What can we do to be proactive? Simulations! 12
13 Getting in control of your COOLING Theoretical Heat Map Actual Heat Map Actual Screenshots of Schneider Electric s StruxureWare for Data Centers 13
14 Getting in control of your COOLING Theoretical Heat Map Theoretical Velocity Map Actual Screenshots of Schneider Electric s StruxureWare for Data Centers 14
15 for Data Centers A la carte applications Data Center Dashboard Resource Advisor Enterprise Energy Operation Online Energy Operation Advanced DCIM Data Center Operation Building Operation Asset Operation Power Monitoring Expert Power SCADA Expert Operations Data Center Infrastructure Management Data Center Expert Process Expert Building Expert Security Expert Control 15
16 BMS Power Management Cooling Control VM Management Server Management CMDB IT Tickets Too much data in siloed systems Facility Management IT Management 16
17 BMS Power Management Cooling Control VM Management Server Management CMDB IT Tickets Seamless integration of key data Facility Management IT Management Data Center Infrastructure Management (DCIM) 17
18 DCIM becomes the centerpiece for operational efficiency Facility Management (BMS, Power Management, Cooling control, etc.) DCIM Capacity Planning Analytics Simulation Optimization Data Management Reporting IT Systems, VM Management, Etc. Data collection, meters, sensors, etc. 18
19 1 Managing Power, Cooling and Space remains the primary challenge in DCs 2 DCIM is the way to eliminate risks in Data Center operation by proactive Capacity Planning 3 StruxureWare for Data Centers supports your decision making with knowledge rather then information overload 19
20 Dimitris Ioannou Sales Manager, E&S Services Mobile: According to IDC analysis and buyer perception, Schneider Electric is an IDC MarketScape Leader worldwide. IDC MarketScape: Worldwide Datacenter Infrastructure Management 2013 Vendor Analysis, Jennifer Koppy, June
The Software-Defined Data Center and it s impact on the physical infrastructure
The Software-Defined Data Center and it s impact on the physical infrastructure Soeren Juul Schroeder Schneider Electric Power to the Cloud, Dubai November 25 th 26 th 2013 September 4 th 1882 2 3 4 The
Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)
Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Salim Janbeh Physical Infrastructure Consultant [email protected] PANDUIT You Can t Manage What You Don t Measure:
Smart Building. Life is On. 5 maart 2015 Jack Hack - Solution Architect
Smart Building Life is On 5 maart 2015 Jack Hack - Solution Architect Agenda > Trends & How the Internet of Things enables the convergence of IT & Energy > Role of a datacenter in a smart building > Create
Simplifying Data Center Design/Build
Simplifying Data Center Design/Build A new approach to deliver speed, cost, and performance (availability, efficiency, scalability) Eduard Bodor Data Center Business Development Manager for Central and
Data Center Infrastructure Management: ERP for the Data Center Manager
Data Center Infrastructure Management: ERP for the Data Center Manager 1 2 Topics What s DCIM & the ERP Analogy Why DCIM How DCIM Works How DCIM Helps 3 DCIM by Definition DCIM is a system that collects
StruxureWare. How to reconcile efficiency and availability in a virtualized data center. for data centers
How to reconcile efficiency and availability in a virtualized data center TM StruxureWare for data centers Soeren Brogaard Jensen 27th of October 2011 Vilnius, Litauen Schneider Electric the global specialist
Data Center Infrastructure Management (DCIM) Utility Energy Efficiency Opportunities Discussion & Demos July 2, 2013
Data Center Infrastructure Management (DCIM) Utility Energy Efficiency Opportunities Discussion & Demos July 2, 2013 Ted Brown Sr. Energy Management Analyst Data Center / IT Energy Efficiency [email protected]
S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015
S c h n e i d e r E l e c t r i c BUSINESS IMPACT Datacenter means business - create the bridge between IT en Facilities. Jack Hack Enterprise System Engineer 19 November 2015 1 Your ability to compete
Data Center Infrastructure Management (DCIM) StruxureWare Data Center Operation StruxureWare Data Center Expert
Data Center Infrastructure Management (DCIM) StruxureWare Data Center Operation StruxureWare Data Center Expert In an environment of constant change Increasing availability expectations Cloud computing
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
DCIM: Datacentre Management in a Software Driven Age
DCIM: Datacentre Management in a Software Driven Age Rhonda Ascierto Research Director, Datacentre Technologies 1 2 3 When do you expect to see an ROI on your DCIM investment? Colos Enterprise Short-term
Cheat Sheets to Data Center Infrastructure Management
^ Business-wise, Future-drivenTM Cheat Sheets to Data Center Infrastructure Management The Brands You Trust. Table of Contents Introduction...3 How DCIM helps operations...4 How DCIM helps planning...5
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
Visualization, Management & Optimization Keys for an efficient Data Center Sergio Uribe - CommScope
Visualization, Management & Optimization Keys for an efficient Data Center Sergio Uribe - CommScope May 14,15-2014 Before to start Lopsided data center budget growth Allocating the cost of IT inefficiency
RACKWISE Data Center Manager
RACKWISE Data Center Manager For more information on RACKWISE Data Center Manager, visit or contact us at [email protected] or (888) 818-2385 Corporate Headquarters 2365 Iron Point Road Suite 190 Folsom,
Data Center Infrastructure Management (DCIM) Demystified
software is quickly becoming the core engine of data center operations. Only 5 years ago, manual spreadsheets, sometimes supplemented with Visio diagrams, were accepted as the default tools for data center
Improve competiveness of IDC and enterprise data centers with DCIM
Improve competiveness of IDC and enterprise data centers with DCIM This paper studies the implementation of modern DCIM systems for data centers to improve operational competitiveness with ATEN's DCIM
The CEETHERM Data Center Laboratory
The CEETHERM Data Center Laboratory A Platform for Transformative Research on Green Data Centers Yogendra Joshi and Pramod Kumar G.W. Woodruff School of Mechanical Engineering Georgia Institute of Technology
Understanding the Promise of (DCIM)
Understanding the Promise of Data Center Infrastructure Management (DCIM) Chuck Kramer, RCDD, NTS, CDCP, CDFOM Senior Solutions Consultant Emerson Network Power What is DCIM? The monitoring, collection
Managing Power Usage with Energy Efficiency Metrics: The Available Me...
1 of 5 9/1/2011 1:19 PM AUG 2011 Managing Power Usage with Energy Efficiency Metrics: The Available Metrics and How to Use Them Rate this item (1 Vote) font size Data centers consume an enormous amount
DCIM Data Center Infrastructure Monitoring
DCIM Data Center Infrastructure Monitoring ServersCheck offers a flexible, modular and affordable DCIM solution. It is based on our range of IP & SNMP hardware environmental sensors and management software.
Data Centre Infrastructure Management DCIM. Where it fits with what s going on
Data Centre Infrastructure Management DCIM Where it fits with what s going on ITIL reducing IT OPEX by 25% ITIL is about processes these are defined in two main areas ITIL Service Delivery processes :
Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change
Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change DATA CENTRE LOCATIONS Forum Kouvola, Finland Hitachi in Europe September 2011 By Ian Blond Head of Data Centre
THE WORLD S MOST EFFICIENT DATA CENTER
THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject
The New Data Center Cooling Paradigm The Tiered Approach
Product Footprint - Heat Density Trends The New Data Center Cooling Paradigm The Tiered Approach Lennart Ståhl Amdahl, Cisco, Compaq, Cray, Dell, EMC, HP, IBM, Intel, Lucent, Motorola, Nokia, Nortel, Sun,
How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent
StruxureWare for Data Centers
StruxureWare for Data Centers Data Center Infrastructure Management (DCIM) software Tap the full business value of your data center. Sales & Service greensource Cincinnati 19 East 8th Street Cincinnati
Microsoft Private Cloud
Microsoft Private Cloud Lorenz Wolf, Solution Specialist Datacenter, Microsoft SoftwareOne @ Au Premier Zürich - 22.03.2011 What is PRIVATE CLOUD Private Public Public Cloud Private Cloud shared resources.
AIRAH Presentation April 30 th 2014
Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining
Improving Data Centers Energy Reliability & Efficiency. December 2015
Improving Data Centers Energy Reliability & Efficiency December 2015 Background The challenges Alternative solutions SATEC approach Advantages Cases Summary Data Centers Energy Challenges Worldwide Data
Data Center Infrastructure Management (DCIM)
Data Center Infrastructure Management (DCIM) Fergus Wong Business Development Manager, IT Business Cloud Data Center management Cloud Computing (Virtualization) Myths Always increases efficiency Requires
Classification of Data Center Infrastructure Management (DCIM) Tools
Classification of Infrastructure Management (DCIM) Tools White Paper 104 Revision 3 by Kevin Brown Dennis Bouley > Executive summary Data centers today lack a formal system for classifying infrastructure
Revolutionizing Data Center Infrastructure Management
Infrastructure Management & Monitoring for Business-Critical Continuity TM Revolutionizing Data Center Infrastructure Management The Trellis Platform A Real-Time Solution to Continuous Performance Improvement
Case Study Nottingham Trent University
Data Centre Solutions...energy efficient by design Case Study Nottingham Trent University Nottingham Trent University deploys Modular Data Centre Technology (MDC) Designed & Manufactured by Workspace Technology
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms White Paper 43 Revision 3 by James Spitaels > Executive summary The power requirement required by data centers and network rooms varies on a minute
The Pros and Cons of Modular Systems
The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated
5 Reasons. Environment Sensors are used in all Modern Data Centers
5 Reasons Environment Sensors are used in all Modern Data Centers TABLE OF CONTENTS 5 Reasons Environmental Sensors are used in all Modern Data Centers Save on Cooling by Confidently Raising Data Center
InfraStruxure Data Centre Management Software. Holistic open standards integrated data centre management solution.
Data Centre Solutions...energy efficient by design InfraStruxure Data Centre Management Software Holistic open standards integrated data centre management solution. Creating an effective workspace environment
DataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.
DataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation. Dr. Rainer Weidmann, DC Architecture & DC Innovation Dr. Rainer Weidmann, DC Architecture
Managing Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
Midas XCI Immersion Cooling. The High Efficiency, High Density, High Performance Data Center Cooling Solution
Midas XCI Immersion Cooling The High Efficiency, High Density, High Performance Data Center Cooling Solution Midas XCI Immersion cooling technology allows you to maximize server density and power efficiency
Legacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
Data Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
Improve Power saving and efficiency in virtualized environment of datacenter by right choice of memory. Whitepaper
Whitepaper Save power and improve efficiency in virtualized environment of datacenter by right choice of memory A cooperation of Microsoft Technology Center & Samsung Semiconductor Document Version: 2.1
DataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms By Jim Spitaels White Paper #43 Revision 2 Executive Summary The power requirement required by data centers and network rooms varies on a minute
The Efficient Data Center
WHITE PAPER Data Center Efficiency and Optimization Data Center Management The Efficient Data Center Using data center instrumentation and server refresh to optimize compute performance in constrained
Whitepaper from WebNMS M2M. Unified DCIM: Achieving Data Centre Efficiency Beyond IT
Whitepaper from WebNMS M2M Unified DCIM: Achieving Data Centre Efficiency Beyond IT Today s data centers are not just a factory that houses storage systems and stores bytes; they enable to gain competitive
Private & Hybrid Cloud: Risk, Security and Audit. Scott Lowry, Hassan Javed VMware, Inc. March 2012
Private & Hybrid Cloud: Risk, Security and Audit Scott Lowry, Hassan Javed VMware, Inc. March 2012 Private and Hybrid Cloud - Risk, Security and Audit Objectives: Explain the technology and benefits behind
Increasing Data Center Resilience While Lowering PUE
Increasing Data Center Resilience While Lowering PUE Nandini Mouli, Ph.D. President/Founder esai LLC [email protected] www.esai.technology Introduction esai LLC esai LLC: Is a Disadvantaged woman-owned
Critical Capabilities for Data Center Infrastructure Management Tools
Critical Capabilities for Data Center Infrastructure Tools 24 December 2014 ID:G00259287 Analyst(s): Jay E. Pultz, Federico De Silva, Naveen Mishra, Henrique Cecci, Tiny Haynes, David J. Cappuccio, April
Schneider Electric's SmartBunker Provides Smarter, More Secure Datacenters at the Edge
TECHNOLOGY ASSESSMENT Schneider Electric's SmartBunker Provides Smarter, More Secure Datacenters at the Edge Jennifer Koppy Kelly Quinn IDC OPINION Over the next few years, the U.S. market will see an
Comprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of
DCIM Software and IT Service Management - Perfect Together
DCIM Software and IT Service Management - Perfect Together A White Paper from Raritan 2014 Raritan Inc Overview Information Technology is so fundamental to every business today that every organization
Data Center Infrastructure Management: How to Optimize Data Center Operations
Data Center Infrastructure Management: How to Optimize Data Center Operations Khaled Nassoura, PE [email protected] General Manager Raritan, Inc. Question of the Day Question: Would any CFO run
How To Manage Energy At An Energy Efficient Cost
Hans-Dieter Wehle, IBM Distinguished IT Specialist Virtualization and Green IT Energy Management in a Cloud Computing Environment Smarter Data Center Agenda Green IT Overview Energy Management Solutions
Energy Management in a Cloud Computing Environment
Hans-Dieter Wehle, IBM Distinguished IT Specialist Virtualization and Green IT Energy Management in a Cloud Computing Environment Smarter Data Center Agenda Green IT Overview Energy Management Solutions
European Code of Conduct for Data Centre. Presentation of the Awards 2016
European Code of Conduct for Data Centre Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
Classification of Data Center Operations Technology (OT) Management Tools
Classification of Data Center Operations Technology (OT) Management Tools White Paper 104 Revision 0 by Kevin Brown Dennis Bouley > Executive summary Data centers today lack a formal system for classifying
Data Center Infrastructure Management and Automation Systems: an Evaluation Method
Data Center Infrastructure Management and Automation Systems: an Evaluation Method Mauro Faccioni Filho FAZION Ltda Universidade do Sul de Santa Catarina UNISUL Florianópolis, SC, 88025-120, Brasil [email protected]
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly
Minimization of Costs and Energy Consumption in a Data Center by a Workload-based Capacity Management
Minimization of Costs and Energy Consumption in a Data Center by a Workload-based Capacity Management Georges Da Costa 1, Ariel Oleksiak 2,4, Wojciech Piatek 2, Jaume Salom 3, Laura Siso 3 1 IRIT, University
Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell
Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without
Datasheet FUJITSU Software Systemwalker Software Configuration Manager V15
Datasheet FUJITSU Software Systemwalker Software Configuration Manager V15 Patch application and automatic collection of information about cloud resources In modern company IT departments, virtualization
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning 2009, Raritan Inc. Overview Corporate America is more dependent than ever on computing
Centralized Orchestration and Performance Monitoring
DATASHEET NetScaler Command Center Centralized Orchestration and Performance Monitoring Key Benefits Performance Management High Availability (HA) Support Seamless VPX management Enables Extensible architecture
Data Center Power Distribution and Capacity Planning:
Data Center Power Distribution and Capacity Planning: Understanding what you know and don t know about power usage in your data center 2009, Raritan Inc. About This Series Raritan, a leading provider of
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
IDC MarketScape: Worldwide Datacenter Infrastructure Management 2015 Vendor Assessment
IDC MarketScape IDC MarketScape: Worldwide Datacenter Infrastructure Management 2015 Vendor Assessment Jennifer Koppy THIS IDC MARKETSCAPE EXCERPT FEATURES EMERSON NETWORK POWER IDC MARKETSCAPE FIGURE
Comprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara Framework to provide full convergence of
IT BUSINESS. Hal Grant, EVP IT. February 19, 2015
IT BUSINESS Hal Grant, EVP IT February 19, 2015 1 Disclaimer All forward-looking statements are Schneider Electric management s present expectations of future events and are subject to a number of factors
StruxureWare for Data Centers
StruxureWare for Data Centers Rafael Alarcon [email protected] All content in this presentation is protected 2008 American Power Conversion Corporation DCIM Definition DCIM Data Center
I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015
I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 8, Loughborough University, 29 th June 2015 Topics to be considered 1. Progress on project tasks 2. Development of data centre test facility
Building an Open Source Private Cloud
Building an Open Source Private Cloud Billy Cox Director, Cloud SW Strategy Intel Corp Objectives General Cloud Objectives Open Source Agility Cost savings Time to solution Key usage models Common architecture
Intel IT Redefines the High Density Data Center: 1,100 Watts/Sq. Ft
Intel IT Redefines the High Density Data Center: 1,100 Watts/Sq. Ft John Musilli- SR Data Center Architect Paul Vaccaro Data Center Solutions Architect Legal Notices This presentation is for informational
StruxureWare TM Data Center Operation
StruxureWare TM Data Center End to end Management (DCIM) software for monitoring, control of power, cooling, security and energy usage from the building through IT systems Part of StruxureWare for Data
Using CFD for optimal thermal management and cooling design in data centers
www.siemens.com/datacenters Using CFD for optimal thermal management and cooling design in data centers Introduction As the power density of IT equipment within a rack increases and energy costs rise,
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore Introduction Agenda Introduction Overview of Data Centres DC Operational
Power Management. Raritan Description. http://www.raritan.com/products/power-management/
Raritan Description Raritan is a proven innovator of power management, infrastructure management, KVM and serial solutions for data centers of all sizes. In more than 50,000 locations worldwide, our hardware
FAC 2.1: Data Center Cooling Simulation. Jacob Harris, Application Engineer Yue Ma, Senior Product Manager
FAC 2.1: Data Center Cooling Simulation Jacob Harris, Application Engineer Yue Ma, Senior Product Manager FAC 2.1: Data Center Cooling Simulation Computational Fluid Dynamics (CFD) can be used to numerically
Maximo GreenDataCenter. 2008 IBM Corporation
Maximo GreenDataCenter IBM Global Leader in Data Center Management & Innovation Worldwide: 488 datacenters, 61 strategic, 8.3/2.5m sq.ft. Americas: 194 datacenters, 21 strategic, 4.7/1.3m sq.ft. IBM Datacenter
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
HPC TCO: Cooling and Computer Room Efficiency
HPC TCO: Cooling and Computer Room Efficiency 1 Route Plan Motivation (Why do we care?) HPC Building Blocks: Compuer Hardware (What s inside my dataroom? What needs to be cooled?) HPC Building Blocks: