Auditing a data centre but to what standard?
|
|
|
- Marvin Day
- 10 years ago
- Views:
Transcription
1 Auditing a data centre but to what standard? Matt Flowerday RCDD Capitoline LLP [email protected]
2 Data centre auditing Capitoline has audited over 30 data centres in the UK, Ireland, Netherlands and the Middle East Capitoline is the audit partner for the Amsterdam Internet Exchange and Cisco EMEA No two customers have the same expectation from a data centre audit
3 What are the motives to obtain a DC audit? Their customers require it Need to understand Tier rating Know they have problems but need an external consultant to confirm that to free up funding Have current and severe operational problems and need to start the overhaul/replacement process Need ISMS audits such as ISO Need to know their green/co 2 /PUE position Want compliance with H&S and other legislation
4 About 50 separate standards that could be applied to a data centre plus many national requirements
5 Tier rating The UpTime Institute = TIA 942 = BICSI 002
6 Tier Standards TUI is a design philosophy Tier 1, basic requirements Tier 2, redundant components Tier 3, concurrently maintainable Tier 4, Autonomous fault tolerance TIA 942, a prescriptive design guide BICSI 002, some different ideas
7 Physical & Operational problems Overheating Power problems Connectivity Health safety
8 ISMS Information Security Management standards
9 ISO series
10 ISO code of practice Information technology Security techniques Code of practice for information security management 1. Introduction and scope 2. Terms & definitions 3. Structure of the Standard Big on questions but 4. Risk assessment and treatment proposes no answers 5. Security policy 6. Organisation of information security 7. Asset management 8. Human resources security 9. Physical and environmental security 10. Communications and operational management 11. Access control 12. Information systems, acquisition, development & maintenance 13. Information security incident management 14. Business continuity management 15. Compliance
11 Do you handle credit/debit card transactions or keep financial data?
12
13 US requirements Sarbanes-Oxley Act Health Insurance Portability and accountability Act Gramm-Leach Billey Act State level legislation Payment card industry standard International Traffic in Arms Regulations
14
15
16
17
18
19
20 Green credentials 2001 European Directive on Energy performance in Buildings 2006 Building Regulations Part L 2006 EU Energy Services Directive 2007 Climate Change Bill Server and Data Center Energy Efficiency, Public Law , April 2007 Code of Conduct on Data Centres November 2008
21 Make your reputation by inventing a metric The Green Grid Environmental Protection Agency, EPA US Department of Energy, DoE Silicon Valley Leadership Group Mckinsey The UpTime Institute Leader Environmental Design, LEED BREEAM Transaction Processing Performance Council, TPPC
22 Data centre metrics DCiE Data Centre infrastructure Efficiency DCiE = IT equipment Power Total facilities Power Power Usage Effectiveness, PUE = 1 DCiE Advantages Simple Disadvantages the servers, though taking most of the energy, may not actually be doing any useful work
23 Energy Usage Effectiveness EUE Energy Star is developing an improved metric* called Energy Usage Effectiveness (EUE) = Total Energy / UPS Energy EUE is based on energy, not power Total Energy includes all fuels (electricity, natural gas, diesel, etc.) EUE is based on source energy, not site energy Source Energy is the total amount of raw fuel required to operate the building
24 Build on existing ENERGY STAR platform with methodology similar to existing ratings (1-100 scale) Usable for both stand-alone data centers and data centers housed within office or other buildings Offer the ENERGY STAR label to data centers with a rating of 75 or higher
25 The UpTime Institute Data Center Energy Efficiency and productivity (DC-EEP) Index DC-EEP=(IT-PEW) x (SI-EER) IT-PEW=IT Productivity per embedded watt SI-EER=Site Infrastructure Energy Efficiency (same as PUE) TUI say average SI-EER is 2.5 or 40%
26 Harmonizing Global Metrics The United States of America, European Union and Japan Reach Agreement on Guiding Principles for Data Center Energy Efficiency Metrics, February 2, 2010
27 Harmonizing Global Metrics Desired Outcomes Effective energy efficiency metrics that: 1. Measure the actual IT work output of the data center compared to actual energy consumption. It is of note that in the process to define IT work output, the following interim measurements are being defined and / or validated: a. IT - Measure the potential IT work output compared to expected energy consumption; and measure operational utilization of IT equipment b. Data center facility and infrastructure - Measure the data center infrastructure efficiency (PUE) 2. Measure renewable energy technologies and re-use of energy to reduce carbon
28 Data centre Auditing What does the customer want to achieve? Use the right audit package to answer the customer s questions/requirements Select from the range of appropriate standards available. There is no one standard that fits all requirements An audit includes business processes not just physical attributes
29
30 Thank you Matt Flowerday RCDD Capitoline LLP
Auditing a Data Centre But to What Standard?
Auditing a Data Centre But to What Standard? Barry Elliott, RCDD Capitoline LLP [email protected] www.capitoline.eu Data Centre Auditing Capitoline has audited over 30 data centres in the UK, Ireland,
Harmonizing Global Metrics for Data Center Energy Efficiency
Harmonizing Global Metrics for Data Center Energy Efficiency Dan Azevedo, Symantec Chairman - Metrics & Measurements Work Group Industry Trends Energy Efficient IT The Climate Group: Smarter technology
EU Code of Conduct for Data Centre Efficiency
EU Code of Conduct for Data Centre Efficiency A Green Practice Accredited by British Computer Society (BCS) EU Code of Conduct for Data Centre Efficiency Local Organizer Practices in Data Centre Industry
ENERGY STAR Data Center Infrastructure Rating Development Update. Web Conference November 12, 2009
ENERGY STAR Data Center Infrastructure Rating Development Update Web Conference November 12, 2009 Web Conference Tips Background Noise Please mute your phone until you are ready to speak. Hold & Music
This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.
This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 1 Measuring PUE at Dedicated Data Centers 15 July 2010 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations
Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization
Green Data Centers GOING FORWARD ENERGY EFFICIENCY TRENDS André ROUYER Director of Standardization & Environment All content in this presentation is protected 2008 American Power Conversion Corporation
FEAR Model - Review Cell Module Block
F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data
Design Consultancy Audit CFD 3D Modelling Energy Efficiency. Global Data Centres. at the core of your business
Design Consultancy Audit CFD 3D Modelling Energy Efficiency Global Data Centres at the core of your business The Sudlows story Your Data Centre Road Map Building on 100 years of innovation, knowledge and
So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC [email protected]
So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC [email protected] So you want to build a data centre? Who do you contact? How do you work out what
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 2 Measuring PUE for Data Centers 17 May 2011 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations for Measuring
Identifying Energy Saving Opportunities in the Data Center
Identifying Energy Saving Opportunities in the Data Center Andrew Fanara US EPA ENERGY STAR Product Development [email protected] (206) 553-6377 (Seattle, WA) 1 Data Centers are INFORMATION FACTORIES
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics
On January 13, 2010, 7x24 Exchange Chairman Robert Cassiliano and Vice President David Schirmacher met in Washington, DC with representatives from the EPA, the DOE and 7 leading industry organizations
ALWAYS ON GLOBALSWITCH.COM
ALWAYS ON GLOBALSWITCH.COM Data Centre Design Considerations Kelvin Fong Managing Director, Hong Kong ALWAYS ON GLOBALSWITCH.COM Agenda 1. Introduction to Global Switch 2. Customer Requirements 3. Development
Energy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
Data Centre Energy Efficiency: A Call To Action
Data Centre Energy Efficiency: A Call To Action Vic Smith, The Green Grid, EMEA Technical Work Group Chair Dell, Senior Strategic Technologist Agenda Overview of The Green Grid Mission Community of Members
Energy and Sustainability-- Green IT in a holistic approach to slashing energy use, emissions and the impact to the environment
Energy and Sustainability-- Green IT in a holistic approach to slashing energy use, emissions and the impact to the environment Pieter Duijves, Director EMEA/Managing Principal Tanya Starr, LEED AP, DC
Data Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
Green Evaluation Metrics and Software Tool for Data Center
Green Evaluation Metrics and Software Tool for Data Center Wong Hui Shin Faculty of Computing and Informatics, Multimedia University, Cyberjaya, Selangor, Malaysia. [email protected] Saravanan Muthaiyah
How green is your data center?
Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy
Green Computing: Datacentres
Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material
Regional hosted data centre research project for the University of East Anglia
CAPITOLINE Limited Liability Partnership Regional hosted data centre research project for the University of East Anglia A Report into the technical options and costs of Green Data Centre construction Prepared
Green Computing: Datacentres
Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material
Low Carbon Data Centres without compromise
Low Carbon Data Centres without compromise Thursday 16 th September 2010 Pip Squire, Engineering & Project Director delivered by: Ark Continuity - Continuously Delivering high integrity data centres Introduction
Data Center Energy Use, Metrics and Rating Systems
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley National Laboratory October 31, 2007 Today s s
DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M
P a g e 1 DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS David Cosaboon, LEED AP O+M Facility Engineering Associates, P.C. 12701 Fair Lakes Circle, Suite
ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford
ENERGY EFFICIENT DATA CENTRES AND STORAGE Peter James University of Bradford ABOUT US 1998 Co-founded world s first NGO on GreenIT EU Expert Advisors/Project Managers on ICT & Energy Efficiency; Environmental
Building a data center. C R Srinivasan Tata Communications
Building a data center C R Srinivasan Tata Communications Introduction Data Center as defined by TIA 942 A building or a portion of a building whose primary function is to house a computer room and its
The Green Grid, Metrics and DCMM. Presented by: Jay Taylor
The Green Grid, Metrics and DCMM Presented by: Jay Taylor About The Green Grid A not-for-profit international consortium committed to advancing resource efficiency in business computing ecosystems and
Living Green in the Data Center. Dominick Regina Associate Director, Infrastructure Services
Living Green in the Data Center Dominick Regina Associate Director, Infrastructure Services The Challenge Design and build a new stand-alone data center Capacity for at least 10 years of normal growth
DATA CENTERS BEST IN CLASS
Data Energy Audit Chameleon Data Center DATA CENTERS BEST IN CLASS... By Wouter Kok, MSc, Strategic Advisor Global Data Center Practice Deerns leads the way in making data centers greener, by reducing
THE ACS BACKGROUND GENERAL COMMENTS
The ACS (Australian Computer Society) Submission on the Whole-of-Government Information and Communication Technology (ICT) Sustainability Plan, Department of the Environment, Water, Heritage and the Arts
Energy Efficiency and Availability Management in Consolidated Data Centers
Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal
Which Data Center? Key factors in choosing who to trust with your IT Infrastructure
Which Data Center? Key factors in choosing who to trust with your IT Infrastructure Tarif Abboushi Vice-President of Data Center Infrastructure NTT America May, 2009 Which Data Center? Key factors in choosing
BICSI 002 / TIA 942 / Uptime
BICSI 002 / TIA 942 / Uptime Which Data Center Standard Should I Follow Phil Isaak, PE, P.Eng., RCDD, DCDC President, Master Instructor Isaak Technologies Inc. Standards Who are these People Standards
Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.0.0
1 EUROPEAN COMMISSION DIRECTORATE-GENERAL JRC JOINT RESEARCH CENTRE Institute for Energy Renewable Energies Unit Ispra, 1 st January 2015 Code of Conduct on Data Centre Energy Efficiency Endorser Guidelines
ENERGY STAR for Data Centers
ENERGY STAR for Data Centers Alexandra Sullivan US EPA, ENERGY STAR February 4, 2010 Agenda ENERGY STAR Buildings Overview Energy Performance Ratings Portfolio Manager Data Center Initiative Objective
Measuring Energy Efficiency in a Data Center
The goals of the greening of the Data Center are to minimize energy consumption and reduce the emission of green house gases (carbon footprint) while maximizing IT performance. Energy efficiency metrics
Venema Advies Nigeria Limited West Africa Data Center Limited. Datacenter Sustainability
Venema Advies Nigeria Limited West Africa Data Center Limited Datacenter Sustainability Lord of War What if I have AIDS? Don't you worry? You worry too much! Why do you worry about something that can kill
GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers
GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance Chapter : Guide for assessing GHG emissions of Data Centers DRAFT March 0 Table of Contents GHG Protocol ICT Sector
Company Profile Outstanding data centres. Expertise you can trust. Europe s leading provider of premium carrier-neutral data centres.
Company Profile Outstanding data centres. Expertise you can trust. Europe s leading provider of premium carrier-neutral data centres. 02 / TelecityGroup Introduction Outstanding data centres. Expertise
Specialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
Enhancing Competitiveness through Sustainable Supply Chain. Clearstream Solutions. Greener Business
Enhancing Competitiveness through Sustainable Supply Chain Clearstream Solutions Greener Business Agenda Understanding Sustainability : Competitive advantage or disadvantage for Ireland? Why focus on sustainable
The Benefits of ISO50001 Energy Management System & Case Study. Becky Toal MD of Crowberry Consulting Ltd and Lead Auditor SGS
The Benefits of ISO50001 Energy Management System & Case Study Becky Toal MD of Crowberry Consulting Ltd and Lead Auditor SGS Introduction Overview Introduction to the Standard for Energy Management Components
Green Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
Greening The Data Center
Greening The Data Center A Five Step Method for CIO s and Data Center Managers Professionals who manage Data Centers know what is expected from them for performance and uptime. What many are only just
San Francisco Chapter. Deborah Grove, Principal Grove-Associates
Deborah Grove, Principal Grove-Associates Why Green IT is Important 1. The energy consumed by servers in the US (and associated air -conditioning) is equivalent to the annual output of about 20 new coal-fired
Sovereign. The made to measure data centre
Sovereign D ATA C O N N E C T The made to measure data centre Prime Location Within touching distance of everything that s important. 2 Your Customer-Centric Data Centre For the vast majority of organisations
THE NEXT GREEN THING. How Teliti International will help clean up our information and shape the future of green data centres in Malaysia
THE NEXT GREEN THING How Teliti International will help clean up our information and shape the future of green data centres in Malaysia 2 THE FUTURE OF GREEN DATA CENTRES IN MALAYSIA T he industrial revolution
Sustainable Performance for Data Centres. DCEM-Plus
Sustainable Performance for Data Centres DCEM-Plus Energy Management and more! our understanding of the challenges of Data Centers Energy Efficiency and Green IT Creating sustainable performance by reducing
CICS Quick Guide to ISO 50001, the New Energy Management System Standard
CICS Quick Guide to ISO 50001, the New Energy Management System Standard Author: Ann-Marie Currey Energy is high up on everyone s agenda at the moment; from governments worldwide who are keen to support
Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD
Data Center Standards Roundup BICSI, TIA, CENELEC, ISO Steve Kepekci, RCDD Introduction Regardless of business activity or size, all information technology (IT) groups have similar needs Provide secure,
Data Center Management. Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM
Data Center Management Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM A physical place that houses a computer network's most critical systems, including back-up power supplies, air conditioning, and
The Green Data Center
The Green Data Center Energy Efficient Computing In The 21st Century The Green Data Center: Energy Efficient Computing In The 21 st Century Matt Stansberry Site Editor TechTarget [email protected]
Potpourri Track Green IT. Colin Martin Solutions Architect, Cisco Systems Inc. [email protected]
Potpourri Track Green IT Colin Martin Solutions Architect, Cisco Systems Inc. [email protected] 1 Agenda Green Drivers and Initiatives Energy Use Green Buildings and IT Green IT Datacenter Efficiency
A Market Transformation Programme for Improving Energy Efficiency in Data Centres
A Market Transformation Programme for Improving Energy Efficiency in Data Centres Paolo Bertoldi, European Commission Joint Research Centre ABSTRACT The European Code of Conduct for Data Centres is a voluntary
Selecting an Industry-Standard Metric for Data Center Efficiency
Selecting an Industry-Standard Metric for Data Center Efficiency By Neil Rasmussen White Paper #157 Executive Summary The development of standards for the measurement and specification of data center efficiency
Energy Benchmarking for Commercial Buildings. by Michael F. Keohane BE MEngSc
Energy Benchmarking for Commercial Buildings by Michael F. Keohane BE MEngSc What are Benchmarks for? 1. To identify if a buildings energy performance is poor,average or good with respect to other buildings
Renewable Energy. 2015 LORD Green Real Estate Strategies, Inc.
Renewable Energy Benefits of Renewable Energy Meet real estate portfolio GHG emission reduction/reporting goals Use energy that produces no GHG emissions from fossil fuels and reduces air pollution Mitigate
Designing Cabling Systems and Data Centers for Green Building Compliance. Dr. Paulo Marin, EE, MSc. Paulo Marin IT Expert www.paulomarin.
Designing Cabling Systems and Data Centers for Green Building Compliance Dr. Paulo Marin, EE, MSc. Paulo Marin IT Expert www.paulomarin.com Objective This seminar will introduce the Green Building concept
One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet
One unbelievable solution for rack-level data center power management. Sentry Power Manager Solutions for the Data Center Equipment Cabinet Sentry Power Manager. The most comprehensive and affordable rack-level
Eni Green Data Center - Specification
Eni Green Data Center - Specification Green IT Adopting the principles of sustainable development is one of the key missions in the field of information technology today. 2% of the world s CO2 emissions
Engineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty
Engineers Ireland Cost of Data Centre Operation/Ownership 14 th March, 2013 Robert Bath Digital Realty Total Cost of Operation (TCO) Rental TCO - 10 Year Lease Term Power Cooling Connectivity Costs 26%
DPPE: Holistic Framework for Data Center Energy. Efficiency. - KPIs for Infrastructure, IT Equipment, Operation (and Renewable Energy) -
DPPE: Holistic Framework for Data Center Energy Efficiency - KPIs for Infrastructure, IT Equipment, Operation (and Renewable Energy) - August 2012 Japan National Body /Green IT Promotion Council 1. Introduction
Data Center Life Cycle Analysis. Christophe Garnier EMEA Technical Work Group Member Schneider Electric
Data Center Life Cycle Analysis Christophe Garnier EMEA Technical Work Group Member Schneider Electric V3 The 3 Pillars of Sustainability Sustainability = meet the needs of the present without compromising
KWE Basic Philosophy. As of March 2010, KWE is ISO14001 certified at 6 locations in Japan and 8 locations overseas
Green Initiatives KWE Basic Philosophy As a total logistics provider, we aim to contribute to the development of a global society while using resources wisely, promoting harmony with nature, and taking
The Mission Critical Data Center Understand Complexity Improve Performance
The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market
Key Solutions CO₂ assessment
GE Capital Key Solutions CO₂ assessment CO₂ emissions from company car fleets across Europe s major markets between 2008 and 2010 www.gecapital.eu/fleet Contents Introduction and key findings Reduction
Three Steps To Perfectly Green
R E S E A R C H U N D E R W R I T E R W H I T E P A P E R LEAN, CLEAN & GREEN Deerns Consulting Engineers Three Steps To Perfectly Green By Wouter M. Kok, Manager, Cleanroom, Laboratory, and Data Center
The EU Code of Conduct on Data Centres
The EU Code of Conduct on Data Centres Liam Newcombe BCS Data Centre Specialist Group Secretary EU CoC Data Centres Chair, Best Practice Working Group Development Becoming a Signatory Best Practices Use
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008 Contents Welcome and Introduction Chapter 1: Data centre energy recap Chapter 2: Co-generation Chapter 3: CTC case study
Our risk management framework Reviewed quarterly by our executive committee
Our risk management framework Reviewed quarterly by our executive committee Our risk management framework helps us identify and mitigate risks. It is reviewed quarterly and updated to reflect changes particularly
Engineering & Support Services
Engineering & Support Services Expert Project, Engineering & Customer Support Services Providing a range of Engineering and Support Services for:- Mission Critical Environments Data Centres & Server Room
KEY - Ethical Certifications and Memberships
KEY - Ethical Certifications and Memberships Australian BMP Cotton The Australian BMP Cotton trademark is the consumer s guarantee that the branded textile product they are buying is made of Australian
DOE Data Center Energy Efficiency Program
DOE Data Center Energy Efficiency Program Paul Scheihing U.S. Department of Energy Energy Efficiency and Renewable Energy April 2009 1 DOE Industrial Technologies Program Worki king to improve th e energy
Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy
Data Center Combined Heat and Power Benefits and Implementation Justin Grau, Google Inc. Sam Brewer, GEM Energy Data Center Challenges Electric Load Densification Thermal Dissipation Requires constant
DC Pro Assessment Tools. November 14, 2010
DC Pro Assessment Tools November 14, 2010 William Tschudi, PE Lawrence Berkeley National Laboratory [email protected] 510-495-2417 1 Slide 1 Assessment tools LBNL is developing tools to assist in performing
Guideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory