1 THE GREEN GRID SAGA -- A GREEN INITIATIVE TO DATA CENTERS: A REVIEW PARTHA PRATIM RAY * Department of Electronics and Communication Engineering, Haldia Institute of Technology, Haldia, Purba Medinipur , West Bengal, India [email protected] Abstract Information Technology (IT) significantly impacts the environment throughout its life cycle. Most enterprises have not paid enough attention to this until recently. IT s environmental impact can be significantly reduced by behavioral changes, as well as technology changes. Given the relative energy and materials inefficiency of most IT infrastructures today, many green IT initiatives can be easily tackled at no incremental cost. The Green Grid - a non-profit trade organization of IT professionals is such an initiative, formed to initiate the issues of power and cooling in data centers, scattered world-wide. The Green Grid seeks to define best practices for optimizing the efficient consumption of power at IT equipment and facility levels, as well as the manner in which cooling is delivered at these levels hence, providing promising attitude in bringing down the environmental hazards, as well as proceeding to the new era of green computing. In this paper we review the various analytical aspects of The Green Grid upon the data centers and found green facts. Keywords: Green computing; data center; green grid. 1. Introduction Environmental issues have been given the most priority in recent years to Information Technology (IT) domain especially on data centers. A data center [30] is such a facility, used to house computer systems and associated components, such as and storage systems and telecommunications. It generally includes redundant or backup power supplies, redundant data communications connections, environmental controls (e.g., air conditioning, fire suppression) and security devices. Energy use is a central issue for data centers. Some facilities have power densities more than 100 times that of a typical office building [9]. For higher power density facilities, electricity costs are a dominant operating expense and account for over 10% of the total cost of ownership (TCO) of a data center [13]. By 2012 the cost of power for the data center is expected to exceed the cost of the original capital investment [17]. In August of 2007, the Environmental Protection Agency (EPA) published a report to congress on Server and Data Center Energy Efficiency. This report detailed the rapidly growing energy costs of data centers ($4.5 billion in 2006, $7.4 billion projected by 2011) and the dramatic increase in data center power consumption (61 billion kwh in 2006, 100 billion projected by In that same year entire information and communication technologies (ICT) sector was estimated to be responsible for roughly 2% of global carbon emissions with data centers accounting for 14% of the ICT footprint [18]. The EPA estimates that servers and data centers are responsible for up to 1.5% of the total United States electricity consumption [19], or roughly 0.5% of US GHG emissions, for 2007 and Given a business as usual scenario green house gas emissions from data centers is projected to more than double from 2007 levels by 2020 [20]. The Green Grid (TGG) [23] is a global consortium of companies, government agencies and educational institutions dedicated to advancing energy efficiency in data centers and business computing ecosystems. The Green Grid does not endorse vendor-specific products or solutions, and instead seeks to provide industrywide recommendations on best practices, metrics and technologies that will improve overall data center energy efficiencies. In this review paper we first analyze the various metrics implied by TGG on data centers to make them energy efficient. Then we look for the power consumption and carbon dioxide emission attributes by data centers and the improvement of these parameters in contrary to as TGG implementations. Thirdly we concentrate on cooling management and unused server related techy implications by TGG. Fourthly on impacts of virtualization. At last we present the corporate structural changes needed to make data centers green with the help of data center logical design guide. This paper is organized as follows: Section 2 presents different TGG metrics. Section 3 presents the energy consumption and carbon dioxide emission scenario. Section 4 presents cooling and server management issues. Section 5 represents impact of virtualization. Section 6 represents the corporate structure and green * Netaji Road, By lane 2, Newtown, Post + District- Cooch Behar, Pin , West Bengal, India. ISSN :
2 data center design guide. 2. Metrics TGG found that several metrics can help IT organizations better understand and improve the energy efficiency of their existing datacenters, as well as help them make smarter decisions on new datacenter deployments. They are as below. Fig. 1. Different metrics to measure data center efficiency Tactical TGG propose the use of Power Usage Effectiveness (PUE) [14] and Datacenter Efficiency (DCE) [14] Rassmussen or Data Center infrastructure Efficiency (DCiE) metrics, wh ich enable data center operators to quickly estimate the energy efficiency of their data centers, compare the results against other data centers, and determine if any energy efficiency improvements need to be made as in Figure 1 below. PUE = Total Facility Power / IT Equipment Power (2.1) DCiE = IT Equipment Power / Total Facility Power (2.2) TGG also considers the development of metrics that provide more granularity for the PUE metric by breaking it down into the following components: [10] 2.2. Strategic Another Data Center Performance Efficiency (DCPE) metric and a refined version of the PUE metric adopted for all major power-consuming subsystems in the datacenter is described as follows: [4] DCPE= Useful Work / Total Facility Power (2.3) Total Facility Power is measured at or near the facility utilitys meter(s) to accurately reflect the power entering the data center. IT Equipment Power would be measured after all power conversion, switching, and conditioning is completed and before the IT equipment itself. The PUE can range from 1.0 to infinity. Ideally, a PUE value approaching 1.0 would indicate 100% efficiency (i.e. all power used by IT equipment only). Currently, there are no comprehensive data which show the true spread of the PUE for datacenters. Some preliminary work indicates that many datacenters may have a PUE of 3.0 or greater, but with proper design a PUE value of 1.6 should be achievable [4] DCD While there are metrics today used to gauge the performance of the data center, their usefulness falls short when measuring data center performance-per-watt. One such metric that is Data Center Density (DCD): [24] ISSN :
3 DCD = Power of All Equipment on Raised Floor / Area of Raised Floor (2.4) 2.4. CPE TGG has introduced an interim metric or proxy for productivity to allow data centers today to estimate their productivity as a function of power used named Compute Power Efficiency [10]. CPE = (IT Equipment Utilization IT Equipment Power) / Total Facility Power (2.5) CPE = IT Equipment Utilization / PUE (2.6) 2.5. ERE Energy Reuse Effectiveness (ERE), which will provide the data center practitioner with greater visibility into energy efficiency in data centers that make beneficial use of any recovered energy from the data centers [16]. ERE = (Cooling + Power + Lighting + IT-Reuse) / IT (2.7) ERE = c PUE (2.8) where c is a factor determined below. Energy Reuse Factor: ERF = Reuse Energy / Total Energy (2.9) ERE can then be defined as: ERE = (1-ERF) PUE (2.10) It can be seen that as ERF goes to 0 (no energy reuse), ERE will equal PUE, as one would expect for a well-behaved metric. It could represent a very efficient design (PUE = 1.2) with a small amount of energy reuse (ERF = 0.17 and ERE = (1-0.17) 1.2 = 1.0) or an inefficient base design (PUE = 2.0) with a lot or energy reuse (ERF = 0.50 and ERE = (1-0.5) 2.0 = 1.0). The theoretical limits of ERE, and ERF can be summarized as: 0<= ERE<= and 0<= ERF<= DCeP TGG introduced the concept of a family of DCP [11] metrics (referred to as DCxP metrics) based on a definition that measured useful work produced in a data center divided by any quantization of a resource consumed to reduce that work. The first metric in this family, DCeP, where the resource consumed is energy. Thus, DCeP is defined as follows: DCeP = Useful work produced in a data center / Total energy consumed in the data center to produce that work (2.11) 2.7. ppue The Partial PUE (ppue) is a new conceptual metric where a PUE-like value for a subsystem (i.e. container is an eligible subsystem) can be measured and reported. 3. Energy consumption and CO 2 emission Since the early2000 a large number of data centers have been implemented in different countries to fill up human needs through computational work, firing up the twins (i.e. power consumption and CO2 emission) again in picture. Figure 2-left, charts the scenarios in the power consumption projection from 2007 to 2011 showing TGG the best of all. In the February 2009 survey, the participating Tier I (less number of servers) data centers were the least likely to measure PUE, and those that did reported the highest average PUE values (Figure 2-right) [2]. We know that server power consumption scales linearly with CPU utilization. Hence altering server processor power saving features such as performance state or p-state (The combination of a specific CPU ISSN :
4 frequency and voltage) a server s power consumption can be reduced (Figure 3-left). Figure 3-right, shows the chart of power saving and CO2 (Million Metric Ton) reduction projection in Cooling and server management Fig. 2. Comparison of projected electricity use, all scenarios, 2007 to 2011 [27] (left), Tier I data centers showed the highest PUE measurements (right). In 2007, the Technology and Strategy Work Group of TGG consortium established a system architecture Task Force to investigate and provide guidance on existing and emergent cooling technologies along with the deep understanding of data center layout and operation that can improve the efficiency of data center cooling architectures. Computational Fluid Dynamics (CFD) analysis can be used to optimize data center airflow by identifying weak areas of cooling capacity in the data center. Figure 4-left shows an example of a CFD analysis. The cut-plane across the space shows the air temperature in the space. Figure 4-right represents different cooling solutions [12]. Fig. 3. Impact of p-state on power consumption [5] (left), Annual Savings in 2011 by Scenario (Compared to Current Efficiency Trends) [26] (right). In December 2009, TGG conducted a brief, seven-question online survey to learn more about the number and nature of data center servers that are left on but perform no useful work. The organization heard from 188 respondents, primarily data center managers in the United States, who represented a range of industries and server counts. The survey results above tells that almost 80% of the respondents reported that they have unused servers in their data centers. Figure 5 shows the number of unused server in various IT organizations. According to a 2009 report [15] from analyst firm International Data Corporation (IDC), organizations worldwide in 2008 attributed approximately $145,000,000,000 to management and administration of 33 million servers. That works out to be more than $4,000 per server estimated on 4.4 million unused servers. A March 2010 online article [29] notes that licensing fees and storage expenses for unused virtual servers can tie up resources that could be deployed elsewhere. It cites one organization that discovered it was paying approximately $50,000 in disk and licensing costs for 42 virtual servers that had been offline for more than 90 ISSN :
5 days. That example indicates that an unused virtual server can lead to roughly $1,000 in wasted disk and license costs. Fig. 4. Example of an enhanced multi-airflow design[12] (left), Relative efficiency potentials of different cooling solutions (right). 5. Impact of virtualization A primary motivation for consolidation using virtualization is increased computing efficiency more computing per watt of power consumed by the data centers. The reduced power consumed by the consolidated IT load itself, however, is only the beginning of the savings entitlement that can be claimed when consolidating workloads to a smaller set of physical equipment. The two pie charts illustrates that the fan power represents a larger proportion of the electrical bill after virtualization. Therefore, even though the electric bill decreased (smaller pie chart) it did not decrease (Figure 6-left) by the same amount as the server power. Since Fig. 5. Comparison of the number of unused physical versus physical and virtual servers found in respondents organizations [6]. virtualization and the resulting equipment consolidation, can significantly reduce load, over sizing is an important efficiency issue in a virtualized data center (Figure 6-right). Fig. 6. Electricity Savings vs. Efficiency Gains (Fans Servers only) (left) and Typical infrastructure efficiency curve, using DCiE as the metric (right)[8]. ISSN :
6 6. Corporate structure and data center design guide Partha Pratim Ray / Indian Journal of Computer Science and Engineering While new technologies enable IT organizations to significantly increase the delivered computational performance per watt, the effects of expanding demand for growth is being felt in other parts of the organization, especially Facilities departments. This section explains how greater cooperation by these departments and an integrated, holistic, collaborative approach to their respective missions can greatly enhance how data centers are designed, built, and operated so as to maximize resources and provide the levels of service needed by IT. These strategic and tactical IT and Facilities issues are summarized in Figure 7. Fig. 7. Strategic and tactical issues for IT and facilities managers. Typical organizational structures have IT and Facilities in different parts of the organization with little or no common metrics. To improve this, Facilities must be viewed by senior management as a close partner of IT and more integral to the enterprises overall success. Management must change its view of Facilities as in Figure 8. In 2009, TGG has proposed the logical structure of data center design as a design guide towards the data centers as shown in the Figure 9. Fig. 8. Different states of business [25]. 7. Conclusion In this paper we present the review on The Green Grid a non-profit trade organization of IT professionals formed to address the issues of power and cooling in datacenters. We have collected and analyzed the information about The Green Grid and its approaches based upon power, CO2, cooling, virtualization, corporate and data center design guide. Currently, we are investigating the various other parameters to make the data centers green, hence a more step towards the green computing. ISSN :
7 Fig. 9. Different states of business [25]. References [1] A calculation of data center electricity burden, RCSDEE, EPA, [2] Bednar, R., Winiecki J., Winiecki K., Energy measurement survey results analysis [3] Belady, Christian L. and Malone, Christopher G., Metrics and aninfrastructure Model to Evaluate Data. [4] Belady, C., How to Minimize Data Center Utility Bills, Line 56, [5] Blackburn, M. Five ways to reduce data center power consumption, [6] Blackburn, M., Unused servers survey results analysis, [7] Bodik, P., M. Armbrust, K. Canini, A. Fox, M. Jordan, and D. Patterson, A Case for Adaptive Datacenters to Conserve Energy and Improve Reliability. Berkeley, CA: University of California, Berkeley Reliable Adaptive Distributed (RAD) Systems Laboratory, [8] Bouley, D., Impact of virtualization on data center physical infrastructure, [9] Data Center Energy Consumption Trends. U. S. Department of Energy. [10] Greenberg, S., E. Mills, B. Tschudi, P. Rumsey, and B. Myatt (2006). Best Practices for Data Centers: Results from Benchmarking 22 Data Centers. [11] Haas, j., Monroe, M.,Pflueger,J., Pouchet, J.,Snellin g, P., Rawson,A., Rawson, F. Proxy proposals for measuring data center productivity, [12] Jones, R., Bean, J., Bednar, R., Moss, D., Wallerich, J., Smith, J., Patterson, M. Seven strategies to improve data center cooling efficiency, [13] Koomey, J., Belady, C., Patterson, M., Santos, A., Lange. K.D, Assessing Trends Over Time in Performance, Costs, and Energy Use for Servers Released on the web August 17th, [14] Malone, C., C. Belady. (2006) Metrics to Characterize Data Center IT Equipment Energy Use, In proceedings of 2006 Digital Power Forum, Richardson, TX. [15] Optimizing Infrastructure and Server Management in Tough Economic Times, Bihammar, Patrik, International Data Corporation (IDC), 2009 benefits. [16] Patterson, M., Tschudi, B.,Vangeet, O., Cooley, J., Azevedo, D.ERE: A metric for measuring the benefit of reuse energy from data center, [17] Quick Start Guide to Increase Data Center Energy Efficie ncy. U. S. Department of Energy, [18] Rassmussen, N., Electrical Efficiency Modeling of Data Centers, White Paper 113, APC, (2005). [19] Report to Congress on Server and Data Center Energy Effic iency. U. S.Environmental Protection Agency ENERGY STAR Program. [20] Smart 2020: Enabling the low carbon economy in the information age. The Climate Group for the Global esustainability Initiative (CGGSI). [21] The 2nd Annual Green Grid Technical Forum (AGGTF), [22] The Green Grid, A Framework for Data Center Energy Productivity, May [23] The Green Grid. [24] The Green Grid Opp ortunitydecreasing data center and other IT energy usage patterns, [25] Uhlman. K., Addressing organizational behaviours issues to optimize IT and energy facilities energy efficiency, [26] U.S.E.P.A Energy star program. Report to Congress on Server and Data Center Energy Efficiency Public Law page 14, [27] Blackburn, M. Five ways to reduce data center power consumption, [28] U.S.E.P.A Energy star program. Report to Congress on Server and Data Center Energy Efficiency Public Law page 59, [29] Virtual Sprawl: a symptom of a hidden ailment, Embotics weblog on CIO.com, ISSN :
AbSTRACT INTRODUCTION background
february 20, 2007 GREEN GRID METRICS: Describing Datacenter Power Efficiency Technical Committee White Paper white paper 1 Abstract The Green Grid is an association of IT professionals seeking to dramatically
THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE
THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE 2007 The Green Grid. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted, or stored in any
GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCIE
WHITE PAPER #6 GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCIE EDITORS: CHRISTIAN BELADY, MICROSOFT CONTRIBUTORS: ANDY RAWSON, AMD JOHN PFLEUGER, DELL TAHIR CADER, SPRAYCOOL PAGE 2 ABSTRACT
Measuring Energy Efficiency in a Data Center
The goals of the greening of the Data Center are to minimize energy consumption and reduce the emission of green house gases (carbon footprint) while maximizing IT performance. Energy efficiency metrics
ERE: A METRIC FOR MEASURING THE BENEFIT OF REUSE ENERGY FROM A DATA CENTER
WHITE PAPER #29 ERE: A METRIC FOR MEASURING THE BENEFIT OF REUSE ENERGY FROM A DATA CENTER EDITOR: MIKE PATTERSON, INTEL CONTRIBUTORS: BILL TSCHUDI, LAWRENCE BERKELEY NATIONAL LABORATORY OTTO VANGEET,
Data Center Efficiency Metrics: mpue, Partial PUE, ERE, DCcE
Data Center Efficiency Metrics: mpue, Partial PUE, ERE, DCcE Dan Azevedo, Symantec Jud Cooley, Oracle Michael Patterson, Intel Mark Blackburn, 1E Join The Green Grid Technical Forum conversation on Twitter!
Harmonizing Global Metrics for Data Center Energy Efficiency
Harmonizing Global Metrics for Data Center Energy Efficiency Dan Azevedo, Symantec Chairman - Metrics & Measurements Work Group Industry Trends Energy Efficient IT The Climate Group: Smarter technology
Data Center Energy Efficiency Looking Beyond PUE
Data Center Energy Efficiency Looking Beyond PUE No Limits Software White Paper #4 By David Cole 2011 No Limits Software. All rights reserved. No part of this publication may be used, reproduced, photocopied,
A Case Study about Green Cloud Computing: An Attempt towards Green Planet
A Case Study about Green Cloud Computing: An Attempt towards Green Planet Devinder Kaur Padam 1 Analyst, HCL Technologies Infra Structure Department, Sec-126 Noida, India 1 ABSTRACT: Cloud computing is
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
Datacenter Efficiency
EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
Reducing Data Center Energy Consumption
Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate
Increasing Energ y Efficiency In Data Centers
The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
Green Evaluation Metrics and Software Tool for Data Center
Green Evaluation Metrics and Software Tool for Data Center Wong Hui Shin Faculty of Computing and Informatics, Multimedia University, Cyberjaya, Selangor, Malaysia. [email protected] Saravanan Muthaiyah
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems Paul Mathew, Ph.D., Staff Scientist Steve Greenberg, P.E., Energy Management Engineer
Data Centre Energy Efficiency: A Call To Action
Data Centre Energy Efficiency: A Call To Action Vic Smith, The Green Grid, EMEA Technical Work Group Chair Dell, Senior Strategic Technologist Agenda Overview of The Green Grid Mission Community of Members
Green Computing: Datacentres
Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material
Guideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
Energy Efficiency Monitoring in Data Centers: Case Study at International Hellenic University. George Koutitas, Prof. L. Tassiulas, Prof. I.
UTH and IHU (CI)-WP4 Energy Efficiency Monitoring in Data Centers: Case Study at International Hellenic University Plenary Meeting Gent, February-2012 George Koutitas, Prof. L. Tassiulas, Prof. I. Vlahavas
Managing Data Center Power and Cooling
White PAPER Managing Data Center Power and Cooling Introduction: Crisis in Power and Cooling As server microprocessors become more powerful in accordance with Moore s Law, they also consume more power
Green Computing: Datacentres
Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material
Greener Pastures for Your Data Center
W H I T E P A P E R Greener Pastures for Your Data Center 2 Executive Summary Following a green path, once a concept relegated to a small group of environmentalists and the U.S. Environmental Protection
Potpourri Track Green IT. Colin Martin Solutions Architect, Cisco Systems Inc. [email protected]
Potpourri Track Green IT Colin Martin Solutions Architect, Cisco Systems Inc. [email protected] 1 Agenda Green Drivers and Initiatives Energy Use Green Buildings and IT Green IT Datacenter Efficiency
San Francisco Chapter. Deborah Grove, Principal Grove-Associates
Deborah Grove, Principal Grove-Associates Why Green IT is Important 1. The energy consumed by servers in the US (and associated air -conditioning) is equivalent to the annual output of about 20 new coal-fired
Data Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
Enabling an agile Data Centre in a (Fr)agile market
Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization
Green Data Centers GOING FORWARD ENERGY EFFICIENCY TRENDS André ROUYER Director of Standardization & Environment All content in this presentation is protected 2008 American Power Conversion Corporation
Selecting an Industry-Standard Metric for Data Center Efficiency
Selecting an Industry-Standard Metric for Data Center Efficiency By Neil Rasmussen White Paper #157 Executive Summary The development of standards for the measurement and specification of data center efficiency
Using Simulation to Improve Data Center Efficiency
A WHITE PAPER FROM FUTURE FACILITIES INCORPORATED Using Simulation to Improve Data Center Efficiency Cooling Path Management for maximizing cooling system efficiency without sacrificing equipment resilience
Server Consolidation for SAP ERP on IBM ex5 enterprise systems with Intel Xeon Processors:
Server Consolidation for SAP ERP on IBM ex5 enterprise systems with Intel Xeon Processors: Lowering Total Cost of Ownership An Alinean White Paper Published by: Alinean, Inc. 201 S. Orange Ave Suite 1210
DECREASING DATACENTER AND OTHER IT ENERGY
The Green Grid Opportunity DECREASING DATACENTER AND OTHER IT ENERGY USAGE PATTERNS february 16, 2007 white paper 1 Gartner analysts advise enterprises to make the most efficient use of existing systems
Data Center Power Distribution and Capacity Planning:
Data Center Power Distribution and Capacity Planning: Understanding what you know and don t know about power usage in your data center 2009, Raritan Inc. About This Series Raritan, a leading provider of
Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL
Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency NREL 1 National Renewable Energy Laboratory Presentation Road Map A Holistic Approach to Efficiency: Power, Packaging, Cooling, Integration
abstract about the GREEn GRiD
Guidelines for Energy-Efficient Datacenters february 16, 2007 white paper 1 Abstract In this paper, The Green Grid provides a framework for improving the energy efficiency of both new and existing datacenters.
Smarter Data Centers. Integrated Data Center Service Management
Smarter Data Centers Integrated Data Center Service Management Approx. 3.500 ton CO² is generated by: Diesel Car-6l /100 km 20.000 km Airplane 5 * Brussels-Barcelona Server, 1.5 A, 24*7*365*3.000 Kwhr
DATA CENTER ASSESSMENT SERVICES
DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to
The Mission Critical Data Center Understand Complexity Improve Performance
The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market
Call to Action on Smart Sustainable Cities
Call to Action on Smart Sustainable Cities 1. Introduction Achieving sustainable urbanization, along with the preservation of our planet, has been recognized as one of the major challenges of our society
Managing Power Usage with Energy Efficiency Metrics: The Available Me...
1 of 5 9/1/2011 1:19 PM AUG 2011 Managing Power Usage with Energy Efficiency Metrics: The Available Metrics and How to Use Them Rate this item (1 Vote) font size Data centers consume an enormous amount
Data Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
Data Centre Outsourcing a Buyer s Guide
Data Centre Outsourcing a Buyer s Guide The inside guide to deciding whether to outsource your data centre facility and operations and how to select an appropriate partner. This Guide will help you Determine
Metrics for Data Centre Efficiency
Technology Paper 004 Metrics for Data Centre Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354
How green is your data center?
Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008 Contents Welcome and Introduction Chapter 1: Data centre energy recap Chapter 2: Co-generation Chapter 3: CTC case study
The Green Grid, Metrics and DCMM. Presented by: Jay Taylor
The Green Grid, Metrics and DCMM Presented by: Jay Taylor About The Green Grid A not-for-profit international consortium committed to advancing resource efficiency in business computing ecosystems and
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 1 Measuring PUE at Dedicated Data Centers 15 July 2010 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations
BC43: Virtualization and the Green Factor. Ed Harnish
BC43: Virtualization and the Green Factor Ed Harnish Agenda The Need for a Green Datacenter Using Greener Technologies Reducing Server Footprints Moving to new Processor Architectures The Benefits of Virtualization
Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)
Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Salim Janbeh Physical Infrastructure Consultant [email protected] PANDUIT You Can t Manage What You Don t Measure:
A Market Transformation Programme for Improving Energy Efficiency in Data Centres
A Market Transformation Programme for Improving Energy Efficiency in Data Centres Paolo Bertoldi, European Commission Joint Research Centre ABSTRACT The European Code of Conduct for Data Centres is a voluntary
FNT EXPERT PAPER. // Data Center Business Value Dashboards AUTHOR. Data Center Infrastructure Management (DCIM) www.fntsoftware.
FNT EXPERT PAPER AUTHOR Oliver Lindner Head of Business Line DCIM FNT GmbH // Data Center Business Value Dashboards Data Center Infrastructure Management (DCIM) Energy efficiency is an important strategic
Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310
Energy Efficiency and Green Data Centers Overview of Recommendations ITU-T L.1300 and ITU-T L.1310 Paolo Gemma Chairman of Working Party 3 of ITU-T Study Group 5 International Telecommunication Union Agenda
FEAR Model - Review Cell Module Block
F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data
Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres
What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy
Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress
Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress Dan Azevedo, Symantec Jon Haas, Intel Jud Cooley, Sun Microsystems, Inc. Mark Monroe, Sun Microsystems, Inc. Pam
Greening The Data Center
Greening The Data Center A Five Step Method for CIO s and Data Center Managers Professionals who manage Data Centers know what is expected from them for performance and uptime. What many are only just
General Recommendations for a Federal Data Center Energy Management Dashboard Display
General Recommendations for a Federal Data Center Energy Management Dashboard Display Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 2 Measuring PUE for Data Centers 17 May 2011 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations for Measuring
Data Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009
IT Cost Savings Audit Information Technology Report Prepared for XYZ Inc. November 2009 Executive Summary This information technology report presents the technology audit resulting from the activities
StruxureWare. How to reconcile efficiency and availability in a virtualized data center. for data centers
How to reconcile efficiency and availability in a virtualized data center TM StruxureWare for data centers Soeren Brogaard Jensen 27th of October 2011 Vilnius, Litauen Schneider Electric the global specialist
THE PATH TO A GREEN DATA CENTER. Hitachi Data Systems and Brocade. Joint Solution Brief
THE PATH TO A GREEN DATA CENTER Hitachi Data Systems and Brocade Joint Solution Brief Hitachi Data Systems The Growing Need for Green Data Center Solutions 50 percent of data centers worldwide will have
The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric
Ee The Efficient Enterprise Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic! 30,000
Building the Energy-Smart Datacenter
Building the Energy-Smart Datacenter How Dell PowerEdge servers, services, tools and partnerships can help customers save money by saving energy. As businesses grow, they need more computational capacity.
CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense
CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to
DC Pro Assessment Tools. November 14, 2010
DC Pro Assessment Tools November 14, 2010 William Tschudi, PE Lawrence Berkeley National Laboratory [email protected] 510-495-2417 1 Slide 1 Assessment tools LBNL is developing tools to assist in performing
DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M
P a g e 1 DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS David Cosaboon, LEED AP O+M Facility Engineering Associates, P.C. 12701 Fair Lakes Circle, Suite
Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics
On January 13, 2010, 7x24 Exchange Chairman Robert Cassiliano and Vice President David Schirmacher met in Washington, DC with representatives from the EPA, the DOE and 7 leading industry organizations
EU Code of Conduct for Data Centre Efficiency
EU Code of Conduct for Data Centre Efficiency A Green Practice Accredited by British Computer Society (BCS) EU Code of Conduct for Data Centre Efficiency Local Organizer Practices in Data Centre Industry
Energy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
DataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
EMC, VNX and ENERGY EFFICIENCY
White Paper EMC, VNX and ENERGY EFFICIENCY Providing industry leadership and customer value Abstract This white paper explains the value EMC places on energy efficiency across the corporation and in particular
AIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
PROJECTING ANNUAL NEW DATACENTER CONSTRUCTION MARKET SIZE. By Christian L. Belady, P.E.
PROJECTING ANNUAL NEW DATACENTER CONSTRUCTION MARKET SIZE By Christian L. Belady, P.E. GLOBAL FOUNDATION SERVICES MARCH 2011 Author s Note: this work is intended to be an exercise to estimate the size
Page 1. White Paper, December 2012 Gerry Conway. How IT-CMF can increase the Energy Efficiency of Data Centres
Page 1 White Paper, December 2012 Gerry Conway How IT-CMF can increase the Energy Efficiency of Data Centres Abstract Data centres and their management are under increasing pressure; to increase the efficiency
WATER USAGE EFFECTIVENESS (WUE ): A GREEN GRID DATA CENTER SUSTAINABILITY METRIC
WHITE PAPER #35 WATER USAGE EFFECTIVENESS (WUE ): A GREEN GRID DATA CENTER SUSTAINABILITY METRIC EDITOR: Michael Patterson, Intel CONTRIBUTORS: Dan Azevedo, Symantec Christian Belady, Microsoft Jack Pouchet,
As a growing number of small- and medium-sized organizations (SMOs),
NRDC Issue brief october 2012 ib:12-10-a Is Cloud Computing Always Greener? Finding the Most Energy and Carbon Efficient Information Technology Solutions for Small- and Medium-Sized Organizations As a