Industrial Balances PREMIUM Series 490 IBK/ITK/ISK
|
|
|
- Justin Curtis
- 10 years ago
- Views:
Transcription
1 SWISS MADE Industrial Balances PREMIUM Series 490 IBK/ITK/ISK Precision
2 Industrial Scales PREMIUM Series 490 IBK/ITK/ISK The Precisa 490 Series range of industrial scales stands for outmost Swiss precision. Built for all areas of industrial weighing where high precision is required. Exceptional performance features and built-in automatic self calibration system gives users full confidence in achieving accurate weighing results approved and certified. The wide range of integrated applications makes the Series 490 first choice for every conceivable industrial weighing application. Ease-ofuse included. The finest electro-magnetic force restoration system, which conforms to the highest metrological standards, secure that all weighing
3 Terminals User-friendly, multi-application terminals designed to meet every weighing requirement. Terminal IB User-friendly indicator. Standard keyboard layout with 10 keys. 4 freely definable function keys. Large digital display, 20 digit display information line. Vacuum fluorescent display. Weighing-in guide +/- Applications included: weight unit switching, counting, percent weighing, net totals, check weighing, animal weighing, totalisation, statistics, calculation, area weight calculation, Multi-User Memory (MUM). Terminal IT User-friendly, multi-application indicator. Additional keyboard for alphanumerical inputs for manual tare and reference weight input. Vacuum fluorescent display. Weighing-in guide +/- Applications included: all the above applications included with Indicator IB plus Dynamic Differential Weighing (DDW), Minimum Sample Weight (MSW), density determination, Multi-level Backweighing (MBW). Terminal IS Multi-application indicator for special applications. Additional keyboard with 30 keys for alphanumerical inputs for manual tare and reference weight input. Vacuum fluorescent display. Weighing-in guide +/- All applications as per Indicator IT and additional SmartBox. Counting: advanced parts counting with multiple memory functions Extended counting and storage functions with 1000 product storage positions, 250 stored tare-weights, nominal and tolerance values. Totalization, definition of print format, memory protection. FPVO: Check and reference weighing of finished products during the production process, Establishing under or over filling using 500 article storage positions, 500 daily and weekly statistics, average tare weight calculation, machine identification, print format definition, memory protection.
4 SCS fully automatic self-calibration system The PREMIUM 490 Series is equipped with a fully automatic time and temperature controlled internal calibration system (SCS). The SCS can be set to provide regular calibration at predetermined times or temperature changes in accordance with ISO and GLP guidelines. Additionally external calibration can be achieved via the Intelligent Calibration Mode (ICM) with a choice of external weights. IP65 Protection The PREMIUM 490 Series is available with IP65 industrial protection as an option. IP65 protects against ingress of dust and water splashes. The balance is fitted with a protective keyboard. Versatile connectivity Connectivity Signal Barcode Printer Remote display PC I/O Box Ethernet The standard interface can work as RS232 or as Precisa BUS. RS232 for single connection of: RS232 (only one Printer or one PC) Precisa BUS (parallel with Precisa BUS boxes) Platform Additional 2 RS232 connections in indicator Terminal ISK for: - Barcode - Reference balance Terminal IBK, ITK, ISK Precisa BUS boxes for parallel connection of: - Signal Lamp - Barcode scanner - Remote display - I/O Box - Ethernet The indicator Terminal ISK contains a Precisa BUS and 2 RS232 connections for: - Barcode scanner - Reference balance
5 Options Set for EC / OIML verification, fitted at factory, not verified, available only for balances with EC (/ OIML) Type approval EC-Verification according to 90/384/ECC by Precisa (initial verification) available only for balances with EC (/ OIML) Type approval Protection IP65: protection against ingress of dust and low pressure water jets, fitted at factory, not all types available Precisa BUS Accessories 490 IxK on demand 490 IxK Remote / secondary display free-standing with cable 1.5 m Remote / secondary display mounted to the balance Remote / secondary display mounted to the wall with cable 3 m Interface RS232 for data transmission: - to PC, Printer or Barcode-Printer from Barcode Reader ( ) or Reference-Balance Interface 20mA current loop passive Analog output -10V V (Resolution 10 mv) Ethernet Interface, Wired Ethernet Interface, Wireless Signal Lamp, indicator with 3 lamps, green / red / yellow Horn for Signal Lamp Input / Output module with 6 TTL Inputs / 8 Relay Outputs CCE-Bar code scanner BCS5040 with push button and plug to be connected to the Interface RS (Connector DB25) Accessories, Series IxK Wall bracket for display Post for rear mounted display Extended connection-cable indicator to platform available in lengths of 0.1 m up to 10 m on demand Order No xxx, where xxx is code for the length in 0.1 m xxx (e.g for 3.0 m, for 9.5 m) Below the balance weighing feature up to 40 kg Below the balance weighing feature IP65 version up to 40 kg External USV accu power pack Dust cover for indicator, set of 20 pieces Anti-theft device Printer CBM V - with cable and paper roll Printer CBM V - with cable and paper roll Paper roll for Printer CMB Ribbon for Printer CBM Data cable RJ45 / DB9 Female 1.5m (PC) Data cable RJ45 / DB25 Female 1.5m (PC) Data cable RJ45 / DB25 Male 1.5m (Printer) SmartBox Application accessories CCE-Bar code scanner BCS5040 with push button and plug to be connected direct to the SmartBox (Connector RJ45) 490 ISK Features and Applications Swiss made Support IQ/OQ/PQ Units g, mg, ozt, lb, tael, etc. Net total application Add-up summation Dosage program Vacuum Fluorescent Display Anti theft protection,password plus mechanical security % weighing Free conversion program Area conversion program (paper program) Fully automatic internal calibration system SCS Direct tare entry (manual), direct reference weight entry Counting program Statistics Easy alpha-numeric input Clock (Printout GLP/GMP, Auto-Cal etc.) Animal Weighing Automatic Repeatability Test Check weighing plus/minus Below balance weighing Density determination Minimum Sample Weight Recorder Dynamic Difference Weighing Multi-level-backweighing
6 Precisa Series 490: Technical Specification Terminal IBK User-friendly multi-application indicator (IBK) Terminal ITK Indicator with alpha-numeric input and manual tare (ITK) Terminal ISK Indicator with integrated SmartBox (ISK) Precision Balances 0.1 g Model Capacity Readability Repeatability Linearity Pan Size (mm) Response time Verification scale interval Sensitivity drift C (ppm / C) IBK 12000D g 0.1 g 0.1 g 0.2 g 400 x s 1 g 4 IBK 18000D g 0.1 g 0.1 g 0.2 g 400 x s 1 g 3 IBK 24000D g 0.1 g 0.1 g 0.2 g 400 x s 1 g 3 IBK 34000D g* 0.1 g 0.1 g 0.2 g 400 x s 1 g 2 IBK 34000D-DR / g* 0.1 g / 1 g 0.1 g 0.2 g 400 x s 1 g 4 IBK 34000D-FR g* 0.1 g - 1 g 0.1 g 0.2 g 400 x s 1 g 4 *approved max g Dimensions (WxLxH) with terminal 400x465x150 mm Dimensions (WxLxH) without terminal 400x300x150 mm Net weight 15 kg Protection platform IP 54 (IP65 optional) Precision Balances 1 g Model Capacity Readability Repeatability Linearity Pan Size (mm) Response time Verification scale interval Sensitivity drift C (ppm / C) IBK 20000G g 1 g 0.5 g 1 g 400 x s 1 g 4 IBK 30000G g 1 g 0.5 g 1 g 400 x s 1 g 4 IBK 40000G g 1 g 0.5 g 1 g 400 x s 2 g 4 IBK 60000G g 1 g 1 g 1.5 g 400 x s 10 g 4 Dimensions (WxLxH) with terminal 400x465x150 mm Net weight 15 kg Dimensions (WxLxH) without terminal 400x300x150 mm Protection platform IP 54 (IP65 optional) Common Specifications Floating display Temperature range Line voltage, Tolerance Stability settings Power consumption Frequency adjustible C 115V / 230V, +15% /- 20% adjustable 25 VA Hz Technical modifications reserved Precisa Gravimetrics AG Moosmattstrasse 32 CH-8953 Dietikon Tel (0) Fax 0041 (0) [email protected]
SWISS MADE. Series 320 XB MASTER. Analytical. Precision
SWISS MADE MASTER Series Analytical Precision MASTER Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated
SWISS MADE. Moisture Analyzers. PREMIUM AND MASTER Series 330 XM
SWISS MADE Moisture Analyzers PREMIUM AND MASTER Series 330 XM High Resolution Precision PREMIUM AND MASTER Series 330 XM Moisture Analyzers from Precisa - for efficient measurements and accurate results.
G LO TA A C L RA E N E G
GENERAL CATALOG ICONS The following symbols stand for the most important features and applications of Precisa scales and provide a fast overview of each product. FEATUR Swiss made Liquid crystal display
X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS
X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS X2 Synergy The X2 series embodies synergy between conventional solutions characteristic for high quality balances, and technology intended mainly for
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.
Voyager Pro Analytical and Precision Balances When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro s Advanced Applications simplify even the
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene
Weighing terminals The stainless steel weighing terminals of the 4 Series: IND429, IND439 and IND449 The optimal solution for demanding applications in the food, pharmaceutical and chemical industries.
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output
VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output Introduction: VE02AL, VE05AL is designed for VGA +Stereo Audio signal over cost effective CAT5 cable to instead of VGA and
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
High voltage tester HA 1800 Table-top device
High voltage tester HA 1800 Table-top device single devices Ethernet USB RS-232 digital I/O n ergonomic table-top device, supported by a user-friendly operation n conforms to CE, in accordance with EN
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
Automatic AES Change-Over
Automatic AES Change-Over Thank you for choosing a GHIELMETTI product. We are convinced that your choice will prove to be a wise and worthy decision for many years to come. Your GHIELMETTI product has
Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.
Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
Physical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0
HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2
Microbalances MXA/1... 3. Microbalances MXA/F... 4. Analytical balances XA... 5. Analytical balances XA/X... 6. Analytical balances WAS/X...
CONTENTS Microbalances MXA/1.......................................... 3 Microbalances MXA/F.......................................... 4 Analytical balances XA.........................................
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments
MCP 100 MCP 150 Modular Compact Polarimeters ::: Superior Optical Instruments Your Promise Anton Paar's Solution You have always made sure that your optically active substances meet all quality standards.
Actuator for modulating control AME 435
Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
EFC 3600. Frequency converters
2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation
How To Use A Ci 2001A/B (I2) With A Power Supply (I3)
Weighing Indicator CI-2001A/B OWNER S MANUAL CONTENTS PRECAUTIONS 4 INTRODUCTION 6 THE FEATURES OF CI-2001A/B 6 TECHNICAL SPECIFICATION 7 DIMENSIONS 8 FRONT PANEL(CI-2001A) 9 FRONT PANEL(CI-2001B) 11 REAR
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
On-line Machine Condition Monitoring [The CMS System]
On-line Machine Condition Monitoring [The CMS System] Strategic monitoring control your costs Avoid unplanned downtime Monitor your plant stoppers Early warning maintains profit Efficient and profitable
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
Supplementary Certificate of Approval NMI S669
Bradfield Road, West Lindfield NSW 2070 Supplementary Certificate of Approval Issued by the Chief Metrologist under Regulation 60 of the National Measurement Regulations 1999 This is to certify that an
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
ETHERNET TCP/IP NETWORK!!! VER 2.00
Thermal Label Printing Scale ETHERNET NETWORK!!! VER 2.00 FEATURE PACKED! FAST & SIMPLE OPERATION 60 lb CAPACITY & DUAL-RANGE! kg CONVERSION AT THE TOUCH OF A BUTTON MENU-DRIVEN & USER-FRIENDLY HIGH SPEED
Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
TCR easy Plus Alarm. Operating Instructions
TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
www.smarcom.biz BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION
BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION C A R PA R K M A N A G E M E N T S Y S T E M C A R Barcode ticket application PA R K M A N A G E M E N T S Y S T E M RF card application
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply
LED Sign Module LED Super Tiny Strip LED Accessories LED Power Supply April 2016 LED WATERPROOF MODULE LED WATERPROOF MODULE POLAR SERIES LED Type: 5050 SMD Consumption: 0.50 W / module Luminous Flux:
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
2M IR Mini Dome Quick Installation Guide
2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: [email protected]; www.a-tech.ca
Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC
Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220
Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Series Six Plus Programmable Controller
Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Industrial Bar Code Scanners
DS6400 Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack APPLICATIONS Automated warehousing Medium conveyor sorting Reading on forklift trucks Picking systems Automated shop
Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
LogicLab s.r.l Via della valle 67 20048 Carate Brianza (MI) Tel. +39 0362 805287 Fax. +39 0362 1914102 www.logiclab.it
Test system DV1512A2NCI Single Current Generator Maximum current 15 Arms in continuity and 30 Arms per 1 s Single Voltage generator 150 Vrms Programmable phase between Current and Voltage Programmable
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
Everything you need for protection scheme testing
Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
R60 USB to CAN interface Manual (1.5 EN)
R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522
Y7230A CO 2 Alarm System
Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
CONTIENTS. 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3
CONTIENTS 2008.4 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3 4. PANEL LAYOUT----------------- 4 5. BUTTON FUNCTIONS------------- 5 6. OPERATING
Fieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module
T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L Dimmer Module General The Dimmer Pack can be used with any of Tokistar s LED Lighting Systems operating from our 6, 8 or VDC LED Drivers.
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL
FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values