1 Plug on Type MCBs & Distribution Boards Intelligent Choice for Prestigious Buildings
2
3 Table of Contents QO Series Miniature Circuit Breakers Specifications QOvsRCBO Residual Current Circuit Breakers with Integral Overcurrent Protection 2 3 QOE QWIK-GARD Residual Current Circuit Breakers with Integral Overcurrent Protection 4 QOvs Miniature Circuit Breakers LoadCentre Distribution Boards Specifications Rated Current 0A Rated Current 0A 8 9 CLASSIC Metal Consumer Units Certificates Specifications Rated Current 0A
4 QO Series Miniature Circuit Breakers Specifications All circuit breakers fit all LoadCentre Distribution Boards and Consumer Units in the range. Plug-on circuit breakers are tamperproof and provide positive connection to the busbar in one quick operation. Easy for installation and maintenance, with labour cost saved up to 50%. Current ratings from A to 3A, single, double and triple pole. Instantaneous trip type B, C and D. Rated voltage up to 240V AC single phase or 415V AC three phase 50/0Hz. Comply with BS EN Comply with BS EN : Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 771. Trip-free handle ensures tripping even when the circuit breaker handle is held or locked in the ON position. To restore service, simply switch the indicative buttom from OFF to ON position once the fault has been cleared, which completely eliminates the cost and inconvenience of replacing fuse links or fuse wire. Full Range of QO Series Miniature Circuit Breaker Breakers 2
5 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers with Integral Overcurrent Protection QO1vsRCBO Used in Schneider Electric consumer units, LoadCentre Distribution Boards. Compliance with International Standards: IEC and BSEN 09-1, CE marked. Rated voltage: 240V AC, +%, -15%. Frequency: Hz. Class: AC. Ratings: -45 A to 40ºC. Breaking capacity as per IEC 09: ka. Tripping characteristics: Type C (5- In). Tripping time is in compliance with IEE wiring regulations BS771. Sensitivities: or ma (for protection against direct and indirect contact). ON/OFF Indication: - Trip-free handle through an over-center toggle mechanism that ensure tripping even when the handle is held or locked at the ON position. - Overload, short circuit, and earth fault currects are indicated by location of the handle in the OFF position. Push-to-test Function: - A Yellow push-test button T is positioned on the front of the device for testing that product is operational - The smallest operating voltage for the test button: 0V AC (0.85 Un) Connection: - Phase in: plug-on tyep - Phase & Neutral out: 1 to 2 flexible or rigid cable (tightening torque 2 N.m) Catalogue Number Single Pole Sensitivity ma Rated Current A QO1vsRCBO QO0vsRCBO QO1vsRCBO QO1vsRCBO QO140vsRCBO QO145vsRCBO QO1vsRCBO QO0vsRCBO QO1vsRCBO QO1vsRCBO QO140vsRCBO QO145vsRCBO
6 QO Series RCBO QOE QWIK-GARD Residual Current Circuit Breakers with Integral Overcurrent Protection QOE1C03 Rated voltage of 2V to 240V AC, 50/0Hz, operating voltage: 50V 250V AC, 50/0Hz. Used in Schneider Electric Consumer Units, LoadCentre Distribution Boards and can be retrofitted to existing installations. Compliance with International Standards : Certfiied to IEC 0898 and IEC 09, ka at 240V AC, 50/0Hz, CE market. ON/OFF Indication: ON/OFF marketings are on the face of the circuit breaker along with the international I/O markings. Handle Operation: Trip-free handle through an over-centre toggle mechanism that ensures tripping even when the handle is held or locked in the ON position. Trip Indication: Indication of a tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position. Indication of a tripped circuit breaker on residual current ground fault is by location of the handle in an intermediate position. Push-to-test Function: A push-to-test button is positioned on the front of the device for testing the residual current electronic trip circuit and mechanism tripping interface. Thermal Trip Element: Thermal trip elements are factory calibrated at ºC ambient temperature. Instantaneous trip level: - Type B: (3-5In) Overcurrent protection for sensitive equipment - Type C: (5-In) Overcurrent protection for all application types Class: AC Residual Current Protection: Residual ground-fault trip currents are factory set at ma, ma or 0mA. Trip Mechanism: - Loss of neutral Protection: Device will trip on loss of neutral and is sensitive to both AC and pulsating DC fault current. Device will trip on voltage between neutral and earth greater than 50V AC. - Protection against reversed polarity (Phase and Neutral) - Protection against nuisance tripping (compliance with IEC 1543 for EMC) Mounting: Plug-on connection. 4
7 QO Series RCBO QOE QWIK-GARD Residual Current Circuit Breakers with Integral Overcurrent Protection Short Circuit Capacity (Icn) : 000A Catalogue Number Single Pole Rated Current A Residual Tripping Current ma Terminal Capacity Load L&N 2 Pigtail Wire Connection Color & Length Earth Yellow & Green Neutral Blue Maximum Earth Fault Loop Impedance Zs OHMs at 50V AC (RCCB) 5 Seconds 0.4 Seconds Type B Instantaneous Trip (3In to 5In) QOEB01 QOE1B01 QOE1B01 QOE1B01 QOE1B QOEB03 QOE1B03 QOE1B03 QOE1B03 QOE1B03 QOE1C03 Type C Instantaneous Trip (5In to In) QOEC01 QOE1C01 QOE1C01 QOE1C01 QOE1C QOEC03 QOE1C03 QOE1C03 QOE1C03 QOE1C03 QOEC QOE1C QOE1C QOE1C QOE1C
8 QO Series Miniature Circuit Breakers QOvs Miniature Circuit Breaker Black in color. Instantaneous trip level type C. Indication of tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position & trip status window. In compliance with specifications: BS EN 0898, IEC Miniature Circuit Breaker BS EN : 1992 Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 771. Short Circuit Capacity (Icn) : 000A Catalogue Number Rated Current Teminal Capacity Single Pole Double Pole Triple Pole A 2 QO1VSC QO1VSC QO1VSC QO1VSC QO1VSC QO125VSC QO1VSC QO140VSC QO150VSC QO3VSC QO2VSC QO2VSC QO2VSC QO225VSC QO2VSC QO240VSC QO250VSC QO23VSC Type C Instantaneous Trip (5In to In) QO3VSC QO3VSC QO3VSC QO5VSC QO3VSC QO340VSC QO350VSC QO33VSC Short Circuit Capacity (Icn) : 000A Catalogue Number Rated Current Teminal Capacity Single Pole Double Pole Triple Pole A 2 QO2VSC QO1VSC QO1VSC QO1VSC QO125VSC QO1VSC QO140VSC QO150VSC QO3VSC QO2VSC QO2VSC QO2VSC QO225VSC QO2VSC QO240VSC QO250VSC QO23VSC Type C Instantaneous Trip (5In to In) QO3VSC QO3VSC QO3VSC QO5VSC QO3VSC QO340VSC QO350VSC QO33VSC QO3VSC
9 QO Series Miniature Circuit Breakers QOvs Miniature Circuit Breaker Technical data Main characteristics QOvs ka QOvs ka Insulation voltage (Ui) V AC Operating voltage (Ue) 240/415 V AC Rated impulse withstand voltage (Uimp) 4 kv according to IEC Reference temperature 40 C Operating frequency 50/0 Hz Pollution degree 3 Magnetic tripping Curve C 5 to In b b b b According to IEC/EN Limitation class 3 Rated breaking capacity (Icn) 1P, 240 V AC 2P, 240/415 V AC 000 A 000 A 3P, 240/415 V AC Service breaking capacity (Ics) 0 % Icn 75 % Icn Additional characteristics Degree of protection Device only IP (IEC 0529) Device in modular enclosure IP40 Insulation classe II Endurance (O-C) Electrical 4000 cycles Mechanical,000 cycles Operating temperature -5 C to +0 C Storage temperature -40 C to +85 C Tropicalization (IEC 008-1) Treatment 2 (relative humidity 95 % to 55 C) Weight (g) Circuit-breaker Type QOvs 1P 4 2P 8 3P 312 Circuit-breaker Type Number of poles A B C C' D E QOvs 1P P P DB Dimensions () 7
10 LoadCentre Distribution Boards with Finger Safe Protection Specifications Finger safe design for plug on - main busbar to maximize safety (live part have been totally insulated). Built-in with 4 pole main switch for complete isolation (TPN Type). Quick and easy to install. Accepts 1, 2 & 3 pole Plug-on circuit breakers and RCBOs. Range of incoming devices, including 4 pole. Brass neutral and earth terminal bars for every single pole outgoing way. Plenty of cable space, with knock-outs provided at top and bottom. Used in offices, banks, IT buildings, hotels and coercial premises. Bluish white color epoxy powder paint. Zinc coated corrosion resistant steel enclosure. Rated voltage up to 415V AC three phase. Main switch comply with BS EN Enclosure protection to BS EN 0529 IP41 (on request for higher IP rating). Comply with BSEN 0439 & IEC Finger Safe Full Range of Miniature Circuit Breaker Boards 8
11 LoadCentre Distribution Boards Rated Current 0A Catalogue Number No. of Ways Height Dimensions Width Depth SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC1-0 SQDLC112-0 SQDLC114-0 SQDLC1-0 SQDLC118-0 SQDLC1-0 LoadCentre TPN Type (Installed with 0A TPN Main Switch) SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC2-0 SQDLC212-0 SQDLC214-0 SQDLC2-0 SQDLC218-0 SQDLC2-0 LoadCentre Lug Type (For direct connection w/o Main Switch) SAFE For installation of Circuit Breaker or Residual Current Circuit Breaker with Integral Overcurrent Protection Main isolator SQDLC
12 LoadCentre Distribution Boards Rated Current 0A Catalogue Number No. of Ways Height Dimensions Width Depth SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC1-0 SQDLC112-0 SQDLC114-0 SQDLC1-0 SQDLC118-0 SQDLC1-0 LoadCentre TPN Type (Installed with 0A TPN Main Switch) SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC2-0 SQDLC212-0 SQDLC214-0 SQDLC2-0 SQDLC218-0 SQDLC2-0 LoadCentre Lug Type (For direct connection w/o Main Switch) SAFE For installation of Circuit Breaker or Residual Current Circuit Breaker with Integral Overcurrent Protection SQDLC112-0 Main isolator
13 CLASSIC Metal Consumer Units with Finger Safe Protection Specifications Finger safe design for plug on main busbar to maximize safety. Used in apartments. IT buildings, banks, hotels and coercial premises. White color, epoxy power paint. Zinc coated corrosion resistant steel enclosure. Rated voltage up to 240V AC single phase. Comply with BS EN 0439 & IEC Plug-on main switch complies with BS EN : Plug-on circuit breakers provide positive connection to the busbar in one quick operation, saving up to 50% on wiring and connection time. Rated Current 0A Catalogue Number No. of Ways Dimensions Weight Height Width Depth kg 0A Rated With Space for Incoming Device SDCS14 SDCS SDCS1 SDCS114 SDCS Catalogue Number Description Terminal Capacity Dimensions Weight 2 Height Width Depth kg QOMBX Plug-on Incoming Device 0A double pole main switch Main Isolator Finger Safe Main Busbar SAFE SDCS14 Circuit Breaker or RCBO 11
14 Certificates Miniature Circuit Breaker 12
15 Certificates Consumer unit / LoadCentre 13
16 Certificates Distribution Board Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place, 979 King s Road, Quarry Bay, Hong Kong Tel: (852) Fax: (852) Customer Care Centre: (852) Macau Branch Office: Alameda Dr Carlos D Assumpcao 180, Tong Nam Ah Central Comercio 13G, 13H & 13I, Macau Tel: (853) Fax: (853) As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. SEHK/SQD/008 05/12
Circuit Breaker. Description
Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The
The complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Distribution Boards & Consumer Units
Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Residual Current Protective Devices
Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
more than a breaker it s a breakthrough Compact NSX
Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Trade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
xl 3 configurable assemblies IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES XL 3 configurable assemblies guide to migration from IEC 60439 to IEC 61439
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection
Technical data RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection When connecting aluminium conductors ensure that the contact surfaces of the conductors
SELECTION OF FINAL CIRCUIT PROTECTION
SELECTION OF FINAL CIRCUIT PROTECTION By Phil Williams, Product Marketing Manager, Power Distribution Components, Eaton Executive summary The selection of devices for final circuit protection in electrical
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
Protection catalogue 15
15 Protection catalogue Protection devices MCBs, RCBOs, RCCBs, fuse carriers and surge protection Hager offers a wide range of Modular Protection Devices, such as miniature circuit breakers, auxiliaries
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Breaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
Distribution Boards. A perfect blend of aesthetics, functionality and safety
Distribution Boards A perfect blend of aesthetics, functionality and safety ABB a global leader Distribution Boards ABB (www.abb.com) is a global leader in power and automation technologies that enable
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
How can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
Residual Current Circuit Breaker
Introduction Residual Current Circuit Breaker / ELCB The Fault current overloads and short circuits can be detected by circuit breakers like MCB s MCCB s & HRC Fuses etc. But, Circuit breakers don t detect
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
GE Power Controls. MiniFORM Switchboards
GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD
Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 86-21-5012789 Fax: 86-21-58675966 E-mail: [email protected] LINE 1 LINE 3 LINE 5
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services
The power distribution board that sets new standards
SIVACON The power distribution board that sets new standards SIVACON S4 safe, cost-efficient and flexible Answers for infrastructure. Contents We support you with system 04 05 Maximum safety is our top
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24
1 Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are safe. The introduction of the 17 th Edition
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
MK Electric Sentry Circuit Protection Solutions
MK Electric Sentry Circuit Protection Solutions The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation
IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
E-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
PROTECTION AGAINST ELECTRIC SHOCK by John Ware
16 become live under fault conditions. The potential of the metal enclosure is higher than that of the main earthing terminal of the installation (and that of Earth) because of a potential difference created
MOTOR PROTECTIVE DEVICES
W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory