Alert-3 LCD Alarm v2.1
|
|
|
- Theodore Hardy
- 9 years ago
- Views:
Transcription
1 Operating & Maintenance Manual Alert-3 LCD Alarm v2.1 1ST FLOOR ROOM 12 2ND FLOOR ROOM 25 3RD FLOOR ROOM 37 MAINTEN EXT 302 4TH FLOOR ROOM 47 5TH FLOOR ROOM 58 w w w. a m i c o. c o m
2 Contents User Responsibility 3 Introduction 3-4 Features Description of the Alarm 5-6 Shipment Details 5 The Alarm Back Box 5 The Frame/Module Assembly 5 System Power Supply 6 LCD Module 6 Sensor Module 6 Installation Guide 7-11 The Alarm Back Box 6 For Local Sensor Only 6 Standing Pressure Test 6 Sensor 6-7 Local 6 Remote 7 Frame/Module Assembly 7 System Power Supply 8 Sensor Module 9-10 Gas Display 9 Local 9 Remote 9 LCD Display Module 9 LCD Display Setup 10 Closing The Frame/Module Assembly Programming Gas Locations 12 Model Numbers 13 Spare Part Numbers Sensors 14 Alert-3 Alarm Accessories 14 Demand Check Valves 15 Dimensions 16 2 Amico Corporation
3 Contents Troubleshooting Appendix A 20 Wiring Diagram: LCD Motherboard Appendix B 21 Wiring Diagram: Auto-Switch Power Supply Appendix C 22 Wiring Diagram: LCD Display Module - Alarm Buzzer Appendix D 23 Wiring Diagram: LCD Display Module - Local Sensor Appendix E 24 Wiring Diagram: LCD Display Module - Remote Sensor Appendix F 25 Wiring Diagram: LCD Display Module - Master Module Appendix G 26 Technical Specifications 3
4 User Responsibility Amico Microprocessor Based Alarm USER RESPONSIBILITY The information contained in this Installation, Operation and Maintenance Manual pertains only to the Alert-3 microprocessor based digital LCD Alarm. This product will perform as described in this manual when assembled, The information contained in this Installation and Operation Maintenance operated, maintained and serviced in accordance with the installation instructions provided. Manual, pertains only to the ALERT-2 microprocessor based digital alarm. This product will perform to conformity with the descriptions contained in this manual, when assembled, operated, maintained and serviced in accordance The with alarm the installation must be checked instructions periodically. provided. Parts that are broken, missing, worn, distorted or contaminated must be replaced The alarm immediately. must be checked Should periodically. such repair Parts or that replacement are broken, missing, become necessary, please contact Amico Corporation or their distributors. worn, distorted or contaminated, must be replaced immediately. Should such repair or replacement become necessary, please contact Amico Corporation or their distributors. All All alarms should not be repaired, or or altered without without prior written prior written or verbalor verbal approval from Amico Corporation or its approval of Amico Corporation or it s distributors. Failure to comply will void distributors. Failure to comply will void all warranty on the alarm. all warranty on the alarm. Statements in this manual preceded by the words WARNING, CAUTION, Statements DANGER and in this NOTE manual are of preceded special significance. by the words Please WARNING, read these sections CAUTION, DANGER and NOTE are of special significance. carefully. Please read these sections carefully. WARNING: denotes steps which can prevent injury. WARNING: denotes steps which can prevent injury. CAUTION: denotes steps which can prevent damage to equipment. CAUTION: denotes steps which can prevent damage to equipment. DANGER: denotes steps which can prevent electrical shock to equipment or to prevent serious injury and/or death. DANGER: denotes steps which can prevent electrical shock to equipment or to prevent serious injury and/or death. Introduction The Amico Medical Gas LCD Alarm System (Alert-3) incorporates the latest microprocessor based technology for alarm and surveillance systems. The alarm has been designed to provide user flexibility and reliability. This manual shall enable the customer to install, use and maintain the alarm appropriately. Page: 4 There is one MUTE ( ) or PUSH TO TEST button located on the front face of the LCD panel. The button has two functions: to silence an alarm that has occurred and to view the audible alarm sound level and high and low set points. When an audible alarm is triggered, press the button to silence the alarm. To view the audible alarm sound level and high and low set points, press and hold the button for 20 seconds to display the information on the LCD Alarm screen. All Gases or Vacuums are displayed on the LCD screen for clear visibility to facilitate the monitoring function by hospital personnel. Under normal operation, the gas indicator will be in the GREEN - OK position. If an alarm condition occurs, a RED-Alarm indicator will be displayed and an audible alarm shall be continuous until silenced by pushing the MUTE button. The LCD Alarm can be connected to a Building Management System for a generic alarm indicator. 4 Amico Corporation
5 Features Microprocessor based digital LCD and individual microprocessor on each sensor module Gas-specific sensors can be mounted locally or remotely, up to 100 feet [30.5 m], utilizing 22 gauge shielded twisted pair (2 shielded wires) DISS gas-specific sensor housed in a tamper-proof enclosure. The Sensor Module is housed in an anodized aluminum and nickel-plated brass enclosure to act as an interference barrier The Sensor Module is the smallest computer-calibrated temperature-compensated sensor in the industry PSI, kpa, inhg or BAR display (programmable) Self diagnostic circuitry with error display for problem identification Highly accurate Solid State Pressure piezoresistive transducer Dry contacts for remote monitoring from LCD for a generic alarm condition Modules are factory mounted on a hinged frame assembly for ease of installation and maintenance Field programmable push buttons for adjustment of HI and LOW set-points on display module LCD Alarm available in 1 to 8 gases Description of the Alarm SHIPMENT DETAILS When you receive an Alert-3 LCD series alarm from Amico Corporation, the package will consist of three main sections: the Alarm Back Box, Sensors and the Frame/Module Assembly. THE ALARM BACK BOX The Alarm Back Box contains the auto-switchable System Power Supply with an ON/OFF switch, a built-in fuse and terminal blocks (115 to 220 VAC - 50 to 60 Hz). The back box also incorporates the pipe stubs for applications that require locally (in box) mounted sensors. THE FRAME/MODULE ASSEMBLY The Frame/Module Assembly consists of the frame and the LCD module. The hinged frame is designed to swing down from the back box to facilitate installation and servicing of the alarm. This design will reduce installation time and eliminate the risk of improper installation since all the modules are connected and tested at the factory. 5
6 Description of Modules The Alert-3 LCD Alarm is a high technology microprocessor based module: COMMON TO ALL ALARMS SYSTEM POWER SUPPLY The System Power Supply has been pre-installed into the back box assembly. The System Power Supply converts the AC voltage supply to the alarm into two voltages: 5 VDC (regulated) required by the microprocessor hardware and 15 VDC (unregulated) required by the buzzer and the LCD. This unit also contains the main ON/OFF power switch, the transformer, the heat sink, the main fuse and fuse cover, the rectifying circuitry, the terminal blocks and the low voltage DC power cable for connecting this unit to the module. The System Power Supply can be easily removed and reinstalled by unscrewing it from the back box. LCD MODULE The LCD Module contains the LCD screen, microprocessor, buzzer and the MUTE buttons. The function of the MUTE button is to silence an alarm that has occurred. By holding the MUTE button for 15 seconds, the module will display the high and low pressure set points. This module also contains a fail-safe relay that de-energizes when the buzzer is activated. This relay can be used with the Amico Remote Buzzer for applications requiring a remote audible alarm or a Building Management System. SENSOR MODULE The Sensor Module contains the transducer which converts the source of the pressure/vacuum into a digital signal that is displayed on the LCD module. The sensor module shall be housed in an anodized aluminum and nickel-plated brass enclosure to act as an interference barrier and it is temperature compensated. Each sensor is clearly labeled and color coded for the gas or vacuum being monitored. The sensor module contains a gas-specific DISS fitting to ensure correct connection of the proper sensor to the respective gas. Each sensor has been factory calibrated by computer for the specific gas shown on the sensor housing. 6 Amico Corporation
7 Installation Guide STEP 1: THE ALARM BOX Install the back-box to the studs of the wall at the desired height. Ensure that the box is securely in place. The mounting brackets are adjustable to suit the thickness of the wall. MAKE SURE the box is parallel, squared and flush with the finished wall surface to ensure that the frame assembly will fit properly. STEP 2: FOR LOCAL SENSORS ONLY If the sensors are to be mounted locally (inside the back box), the pipe stubs must be connected to the pipeline. Using silver-brazing techniques, connect each pipe stub to its appropriate gas or vacuum while ensuring that the bottom of the pipe stub is wrapped with a damp cloth. BE CAREFUL not to damage the DISS check-valve by overheating the lower portion of the copper pipe. When the brazing of pipe stubs has been completed, the system can be pressure tested. STEP 3: STANDING PRESSURE TEST Perform a standing pressure test on the piping system as per NFPA-99 Health Care Facilities. Inspect all joints for leaks and make certain each gas is piped to a correspondingly labeled gas service. STEP 4: SENSOR LOCAL (inside the back box) i. Locate the gas-specific sensor module to be installed. ii. In the back box, there are color coded gas labels located under the DISS Demand Check Valves. Each label identifies where each sensor module is to be placed. iii. The sensor module contains a gas-specific DISS fitting. Push the sensor module hex-nut and nipple adapter up into the demand check-valve. With a wrench, tighten the nut so that it makes a good seal. Note: Pressure on sensors are not to exceed 250 psi for pressure sensors and 30 inhg for vacuum sensors. Alert-3 sensor operating pressure range: Mid Pressure (0 to 99 psi) - Oxygen, Medical Air, Nitrous Oxide, Carbon Dioxide High Pressure (0 to 249 psi) - Nitrogen, Instrument Air Vacuum (0 to 30 inhg) - Vacuum, WAGD, AGSS 7
8 Installation Guide Push the sensor module hex-nut and nipple adapter up into the demand checkvalve. With a wrench, tighten the nut so that it makes a good seal. NOTE: Pressure on sensors are not to exceed 250psi for Pressure sensors and 30 for Vacuum sensors B: REMOTE (outside the back box) Amico i. Connect Microprocessor a tee (supplied by others) Based to the pipeline Alarm with a 1/4 NPT female connection that will accept the DISS Demand Check Valve. ii. Locate the gas-specific sensor module to be installed. USER RESPONSIBILITY iii. Thread the DISS Demand Check Valve into the correct gas pipeline. with the installation instructions Page: provided. 12 STEP 5: FRAME/MODULE ASSEMBLY REMOTE (Outside the Back Box) 1. Connect a Tee (supplied by others) to the pipeline with a 1/4" NPT female connection that will accept the DISS Demand checkvalve. 2. Locate the gas specific sensor module to be installed. 3. Thread the DISS Demand check-valve into the correct gas pipe line. 4. The sensor module contains a gas specific DISS fitting. Push the sensor module hex-nut and nipple adapter up into the demand check-valve. With a wrench, tighten the nut so that it makes a good seal. The information contained in this Installation and Operation Maintenance iv. The sensor module contains a gas-specific DISS fitting. Push the sensor Manual, module pertains hex-nut only and to nipple the ALERT-2 adapter into microprocessor the demand check-valve. based With digital a alarm. This product wrench, will tighten perform the nut to so conformity that makes a with good the seal. descriptions contained in this manual, when assembled, operated, maintained and serviced in accordance The alarm must be checked periodically. Parts that are broken, missing, i. Remove the frame/module assembly from its protective box. worn, distorted or contaminated, must be replaced immediately. Should such repair or replacement become necessary, please contact Amico Corporation or their ii. Remove distributors. the corner screws from the front frame section (4 screws). All alarms iii. Attach should the LCD not module be repaired, to the back or box altered assembly without by using prior flat head written screws or verbal approval (provided of Amico with Corporation frame in a plastic or bag) it s to distributors. the hinge located Failure on the to back comply box. will void all warranty on the alarm. Statements iv. Attach in the this frame manual wire with preceded 2 dome head by screws the words (provided WARNING, with frame in a CAUTION, DANGER plastic and bag). NOTE This will are allow of the special frame assembly significance. and back Please box to be read fastened these sections carefully. securely together. CAUTION: The microprocessor circuitry on the ALERT-3 alarm contains sophisticated integrated semiconductors. If it becomes necessary to remove LCD circuit board, PLEASE hold the boards by the edges. DO NOT TOUCH any of the components on the board. Static discharge can cause the modules to malfunction or become damaged. WARNING: denotes steps which can prevent injury. CAUTION: denotes steps which can prevent damage to equipment. 8 Amico Corporation DANGER: denotes steps which can prevent electrical shock to equipment or to prevent serious injury and/or death.
9 all warranty on the alarm. Statements in this manual preceded by the words WARNING, CAUTION, DANGER and NOTE are of special significance. Please read these sections carefully. Installation Guide STEP 6: SYSTEM POWER SUPPLY TURN OFF POWER SWITCH before changing any modules and/or disconnecting any cables. Failure to do so can cause the fuse to blow, damaging the circuitry. WARNING: denotes steps which can prevent injury. i. Ensure that the ON/OFF switch is in the OFF position. ii. Through the top left side of the back box, bring in the AC power wires. Knockouts are provided for making conduit connections to the box. All wiring is to be installed according to local and national codes. CAUTION: denotes steps which can prevent damage to equipment. iii. Connect the AC power to the terminal blocks as shown in the wiring diagram (see Appendix B). STEP 7: SENSOR MODULE DANGER: denotes steps which can prevent electrical shock to equipment or to prevent serious injury and/or death. A: Gas Display (on screen location) The location of gases displayed on screen is dependant upon which sensor channel each individual gas is connected to. The display below indicates which sensor channel corresponds to each location the gas will be displayed on the LCD screen Page:
10 Installation Guide STEP 7: SENSOR MODULE B: LOCAL (inside the back box) i. The sensor module is provided with a 6-8 [0.1 m m] twisted pair of wires. One wire is red (positive) and the other wire is black (negative). Connect the wires to the display module as shown in Appendix D. Take the red wire from the sensor and attach it to terminal Sensor + on the display module. Take the black wire from the sensor and attach it to terminal Sensor -. The terminal block on the display module is clearly marked for proper connection of the sensor wires. ii. Repeat the above procedures with the remaining sensor modules. C: REMOTE (outside the back box) i. The sensor module is provided with a 6-8 [0.1m - 0.2m] twisted pair of wires. Connect the wires to a junction box (not supplied) located near the sensor as per the wiring diagram. ii. Connect a shielded twisted pair cable from the junction box to the back box assembly. Knockouts are provided throughout the alarm back box. Up to 100 feet [30.5 m] of 22 Gauge, shielded twisted pair cable should be used. iii. Connect the red wire from the cable to the terminal on the display module marked Sensor +. Connect the black wire to terminal Sensor - as shown in the wiring diagram (see Appendix E). iv. Repeat the above procedures with the remaining sensor modules using the wiring diagram. NOTE: When remote sensors are used, a shielded or twisted pair cable is required (BELDEN #8451 or equivalent, supplied by others). STEP 8: LCD DISPLAY MODULE If the dry contacts for a generic alarm is to be used for remote monitoring, connect the wires to the appropriate terminals: COM (Common), NO (Normally Open) or NC (Normally Closed), using the diagram in Appendix A. See Appendix G for contact rating. Once the sensors are connected and the power has been turned on, use the following steps to setup the LCD Alarm. 10 Amico Corporation
11 Installation Guide STEP 9: LCD DISPLAY SETUP i. Press the SETUP button (B1) and press the SELECT button (B4) ii. Volume control: 90, 80, 70, 60 press CHANGE UP/DOWN to change noise level iii. Press SELECT for LCD brightness and press CHANGE UP/DOWN to change LCD brightness iv. Press the SELECT button (B4) * The following should be displayed. SENSOR: 1 SENSOR TYPE: show the gas (example: NITROUS OXIDE) UNITS: PSI (to change to kpa, Bar, inhg, mmhg: press button CHANGE DOWN/UP then press SELECT) LOW ALARM: 40 (to change: press button CHANGE DOWN/UP then press SELECT) HIGH ALARM: 60 (to change: press button CHANGE DOWN/UP then press SELECT) CURRENT PRESSURE: displays exact pressure for the line CURRENT OFF SET: to re-calibrate pressure reading press button CHANGE DOWN/UP then press SELECT v. Repeat steps until all sensors are scanned and data is saved. Next it will show SETUP COMPLETE. *All gases should now be displayed. If any errors occur, repeat the steps above. NOTE: Hold the MUTE button for twenty (20) seconds to display current low and high set points. NOTE: Press the Setup button (B1) in order to make corrections/go back. STEP 10: CLOSING THE FRAME/MODULE ASSEMBLY i. Close the frame panel by tightening the screws found on the frame panel to the back box. Ensure that the screws are securely fastened to keep the LCD Alarm closed. ii. Carefully place the front frame over the frame panel. Screw in the screws that were removed in Step 5, part ii. The alarm shall now be ready for use. 11
12 Programming Gas Locations 1. Use the Notepad program to enter information for gas location. Each line can hold up to a maximum of 16 characters. 2. Two lines may be used per individual gas. 3. The order of the text must go in order of gas; meaning the first two lines of text shall represent the 1st gas location, the next two lines of text shall represent the 2nd gas location, and so forth. Please refer to the diagram in the Installation Guide under section 7a to determine gas location on the LCD Alarm screen. 4. Once all the text has been inputted, save the file on to the SD Card with the file name: location. 5. Insert the SD Card into the SD Card Slot on the LCD Alarm board (Refer to Appendix A). 6. While the LCD Alarm is on, press the reset button, then press and hold the setup button until the information from the file saved on the SD Card (location.txt) appears on the LCD Alarm Screen. If the gas location text does not appear on the screen, repeat step #6. If the problem persists, contact Amico Corporation for further assistance. 7. Once the text is visible on the LCD Alarm screen, leave the SD Card in the slot for approximately 1 minute in order for the information to be completely uploaded onto the alarm, and then proceed to remove the card. 8. Once the card has been removed, restart the LCD Alarm to ensure that the locations have been saved onto the LCD Alarm. NOTE: Only capital letters and spaces will be displayed on screen. Small caps, symbols and special characters cannot be displayed. Programming of the gas location is only available for V864 and up. If gas location is required, a new front frame assembly is required; part number A3P-FRMASS-LCD. SD memory card is not provided with device. 1ST FLOOR ROOM 12 2ND FLOOR ROOM 25 3RD FLOOR ROOM 37 MAINTEN EXT 302 4TH FLOOR ROOM 47 5TH FLOOR ROOM 58 6TH FLOOR ROOM 65 ENGINEER EXT 302 Notepad File Updated Display on LCD Alarm 12 Amico Corporation
13 Model Numbers LCD ALARM A3AR-L-XXXXXXXX R = Remote/Local L Defines the Language: C = Conversion (Retrofit) U = English (NFPA) E = English (CSA/ISO) F = French (CSA/ISO) S = Spanish (NFPA/ISO) ALERT-3 SENSOR MODULE A3P-SENS-L-GAS X Defines the Type of Gas: Oxygen = O Medical Air = A MedVac = V Nitrous Oxide = 2 Nitrogen = N Carbon Dioxide = C Waste Anesthetic = W Gas Disposal (NFPA) Anesthetic = E Gas Scavenging System (CSA/ISO) Instrument Air = I Gas Defines the Type of Gas: Oxygen = OXY L Defines the Language: U = English (NFPA) E = English (CSA/ISO) F = French (CSA/ISO) S = Spanish (NFPA/ISO) NOTE: Each Alert-3 Sensor comes with an A2P-PIPE Medical Air = AIR MedVac = VAC Nitrous Oxide = N2O Nitrogen = NIT Carbon Dioxide = CO2 Waste Anesthetic = WAG Gas Disposal Anesthetic = AGS Gas Scavenging System Instrument Air = IAR 13
14 Spare Part Numbers SENSORS Model Number A3P-SENS-E-AIR A3P-SENS-E-CO2 A3P-SENS-E-AGS A3P-SENS-E-N2O A3P-SENS-E-NIT A3P-SENS-E-OXY A3P-SENS-E-VAC A3P-SENS-E-IAR A3P-SENS-U-AIR A3P-SENS-U-OXY A3P-SENS-U-VAC A3P-SENS-U-WAG A3P-SENS-U-IAR Description Sensor Module ISO-AIR Eng. Alert-3 Sensor Module ISO-CO2 Eng. Alert-3 Sensor Module ISO-AGS Eng. Alert-3 Sensor Module ISO-N2O Eng. Alert-3 Sensor Module ISO-NIT Eng. Alert-3 Sensor Module ISO-OXY Eng. Alert-3 Sensor Module ISO-VAC Eng. Alert-3 Sensor Module ISO-IAR Eng. Alert-3 Sensor Module USA-AIR Eng. Alert-3 Sensor Module USA-OXY Eng. Alert-3 Sensor Module USA-VAC Eng. Alert-3 Sensor Module USA-WAG Eng. Alert-3 Sensor Module USA-IAR Eng. Alert-3 ACCESSORIES/MISC. Model Number A3-MAN-ALM-ENG A2P-POWER-V2 A2P-BOXASS-3LCD A3P-FRMASS-LCD A2P-PIPE A3P-DEMO-CASE A2X-BOX-3-FILL A3X-P-SW-PVCAP A3X-LCD-LABEL A3X-LCD-LABEL-MUTE Description Alert-3 Alarm Manual English Power Supply Module Alert-2 Alarm Back Box Assembly 3-Station Alert-2 LCD Alarm Frame Assembly for LCD Alert-3 Pressure Module Pipe Assembly (Alert-2) Alert-3 Demo Alarm Alert-2 Alarm Box Filler Frame 3-Station LCD PVA Switch Cap-Gray LCD Alarm Front Label Alert-3 Mute Label 14 Amico Corporation
15 Spare Part Numbers DEMAND CHECK VALVES Model Number S-DIS-DEMC-AIR S-DIS-DEMC-CO2 S-DIS-DEMC-NIT S-DIS-DEMC-N2O S-DIS-DEMC-EVA S-DIS-DEMC-OXY S-DIS-DEMC-VAC S-DIS-KIT-OXY S-DIS-KIT-AIR S-DIS-KIT-VAC S-DIS-KIT-N2O S-DIS-KIT-NIT S-DIS-KIT-WAG S-DIS-KIT-AGS S-DIS-KIT-IAR S-DIS-KIT-CO2 A3P-LCD-FILLER-4 A2X-BOX-4-FILL A3P-LCD-FILLER-5 A2X-BOX-5-FILL A3P-LCD-FILLER-7 A2X-BOX-7-FILL Description DISS Demand Check Valve 1/4 MNPT - AIR DISS Demand Check Valve 1/4 MNPT - CO2 DISS Demand Check Valve 1/4 MNPT - NIT DISS Demand Check Valve 1/4 MNPT - N2O DISS Demand Check Valve 1/4 MNPT - EVA DISS Demand Check Valve 1/4 MNPT - OXY DISS Demand Check Valve 1/4 MNPT - VAC DISS Demand Check, Nut and Nipple - OXY DISS Demand Check, Nut and Nipple- AIR DISS Demand Check, Nut and Nipple- VAC DISS Demand Check, Nut and Nipple - N2O DISS Demand Check, Nut and Nipple - NIT DISS Demand Check, Nut and Nipple- WAG DISS Demand Check, Nut and Nipple- AGS DISS Demand Check, Nut and Nipple - IAR DISS Demand Check, Nut and Nipple - CO2 Alert-3 Filler Frame 4 - Station Alert-2 Alarm Box Filler Frame 4 - Station Alert-3 Filler Frame 5 - Station Alert-2 Alarm Box Filler Frame 5 - Station Alert-3 Box Filler Frame 7 - Station Alert-2 Box Filler Frame 7 - Station 15
16 Dimensions LCD ALARM Front View Side View 2 1/10 [53.34] Inch [mm] 0.81 [20.57] 1.2 [30.48] 1.2 [30.48] 1.2 [30.48] 1.2 [30.48] 1.2 [30.48] 1.2 [30.48] 1.2 [30.48] 7 3/16 [182] Only supplied with Local Sensors 3/8 [9.53] (O.D.) 1/4 [6.4] (I.D) Type K Copper Pipe NOTE: DISS demand check valves by 1/4 NPT, supplied with each sensor 1 1/4 [32] [162] [260.35] 7 [177.8] 9 [228.6] 7.50 [191] Brazing Filler Metal AWS Spec. BAg-7 12 [304.8] 3.97 [100.84] Mounting Bracket 1/4[6] NPT 1/2-14NPSM THD. Brass 1[25] HEX Top View.75 [19.05] Punched hole for electrical power cord 1 [25.4] 10.7 [271.78] [22.23] 7.5 [190.5] 1.75 [63.5] 2.5 [44.45] 2.5 [63.5] 1 [25.4] 1.2 [30.48].75 [19.05].75 [19.05] Bottom View 1.25 [31.75] ALERT-3 SENSOR 1.88 [48] #22 Gauge twisted pair shielded cable 6-8 [0.1m m] supplied 1/2-14 NPSM [13] Wrench Flats 1 [25] DISS Connector (Approximate, can vary) 1/2 Conduit Connection 16 Amico Corporation
17 Troubleshooting Symptom Cause Corrective Action An error or LOW ALARM LCD screen The Microprocessor detected a fault and has shut down Faulty wire connection between the sensor and LCD module Turn power switch to OFF position. Wait for at least 5 seconds before turning ON the power. The program will reset itself. Check wiring diagram in Appendix D and Appendix E No power on the alarm AC power not available a. Ensure that the ON/OFF switch on the power supply module is turned ON (see Appendix B). b. AC wiring not connected. c. Check the building electrical breaker to ensure that the power is ON. Fuse is blown DC power plug not connected to the LCD module d. Check the voltage at the terminal block above the transformer. Ensure that 115 VAC to 220 VAC is being supplied. Check the fuse. The fuse is located on the upper-right corner of the system power supply. Replace the fuse if it is defective (see Appendix B and Appendix G). a. Ensure that the DC power plug is firmly in its socket on the LCD module. Power light is ON, however there is no display on LCD screen b. Replace the System Power Supply unit if all the above steps fail to resolve the problem. Power failure on screen a. Remove all transducers and reset power No audible alarm DC power cable is disconnected, loose or check ribbon cable b. Replace the LCD module. a. Ensure that the DC power cable from the system power supply is firmly connected to the LCD module. b. Replace LCD board. Audible signal will not silence Faulty display module Disconnect the ribbon cable from the back of the faulty display module and replace the LCD module. Connection of the DC power cable from system power supply to LCD module is loose Faulty push button Disconnect the DC power cable from the LCD module and then reconnect. If audible alarm still persists, replace the System Power Supply unit. Replace the LCD module. 17
18 Troubleshooting Symptom Cause Corrective Action Gas reading incorrect Loose connection of DISS fittings Ensure that the sensor module is properly connected to the DISS demand checkvalve Display shows NO SENSORS Sensor module is not properly wired to the display module Defective sensor or requires calibration Defective LCD display module No sensor(s) are connected to the LCD board Program not set up Faulty sensors Ensure that the sensor module is properly wired to the LCD module by using wiring diagram in Appendix D or Appendix E Replace the sensor module Replace the LCD display module Make sure sensor module(s) are connected to LCD board (see Appendix D and Appendix E) Press setup and select button to program all connected sensors (see LCD Display Set-Up in Section 9) Replace sensors FACTORY DEFAULT SETTING GAS Mid Pressure Hi = 60 psi Low = 40 psi Vacuum Hi = 32 inhg Low = 12 inhg High Pressure Hi = 195 psi Low = 140 psi 18 Amico Corporation
19 Appendix A WIRING DIAGRAM: LCD MOTHERBOARD DC Power Cable: Connect to Annunciator Module DC Connector Mute Button (located on reverse side of board) Buzzer Sensor Terminal LCD Cable Connector Reset Button 12V DC Output SELECT/MUTE CHANGE DOWN CHANGE UP SETUP LCD Power B4 B3 B2 B1 Microchip Four Push Buttons SD Memory Card Slot (card not provided) Dry Contacts (to Building Management System/Master) 19
20 Appendix B WIRING DIAGRAM: AUTO-SWITCH POWER SUPPLY AC AC Supply 115 to to 220 VAC G N L L - Live N - Neutral G - Ground L - Live N - Neutral G - Ground Toggle Switch Toggle Switch Ground Fuse (1 AMPw) (1 AMPw) DC Power Cable: Connect to LCD Module DC Power Cable: Connect to Annunciator Module 20 Amico Corporation
21 Appendix C Toggle Switch AC Supply 115 to 220 VAC G N L WIRING DIAGRAM: LCD DISPLAY MODULE - ALARM BUZZER NO COM NC 12V GND NO COM NC 12V GND DC Power Cable: Connect to Annunciator Module NO COM NC 12V GND NO COM NC 12V GND NO COM NC 12V GND NO COM NC 12V GND NOTE: Relays on the annunciator are fail safe for Version 3.1 or newer. SELECT/MUTE CHANGE DOWN CHANGE UP SETUP Relays are not fail safe for Versions 3.0 or older. B4 B3 B2 B1 21
22 Appendix D AC Supply 115 to 220 VAC WIRING DIAGRAM: LCD DISPLAY MODULE - LOCAL SENSOR Toggle Switch G N L OXYGEN Sensor Module #22 # 22 Gauge Gauge twisted twisted pair shielded cable cable [0.15m [0.1m-0.2m] - 0.2m] supplied supplied DC Power Cable: Connect to Annunciator Module Black Red SETUP CHANGE UP CHANGE DOWN SELECT/MUTE B4 B3 B2 B1 22 Amico Corporation
23 Appendix E AC Supply 115 to 220 VAC WIRING DIAGRAM: LCD DISPLAY MODULE - REMOTE SENSOR G Toggle Switch N L Sensor Module # 22 Gauge twisted pair shielded cable 6-8 [0.1m-0.2m] supplied OXYGEN Oxygen Pipeline DISS Junction Box (by others) Remote location alarm DC Power Cable: Connect to Annunciator Module #22 Gauge twisted pair shielded cable 100 [30.5 m] max. Fuse (1 A Black Red Note: For multiple sensors, a multi-conductor twisted pair cable can be used. Note: For multiple sensors, a multi-conductor shielded twisted pair cable should be used SETUP CHANGE UP CHANGE DOWN SELECT/MUTE B4 B3 B2 B1 23
24 Appendix F WIRING DIAGRAM: LCD DISPLAY MODULE - MASTER MODULE AC Supply 115 to 220 VAC Sensor Module OXYGEN Toggle Switch #22 Gauge twisted pair shielded cable 6"-8 [0.1 m-0.2 m] supplied G N L #22 Gauge twisted pair shielded cable 100 [30.5 m] max. DISS Junction Box (by others) L - Live N - Neutral G - Ground Remote location Alarm DC Power Cable: Connect to Annunciator Module #22 Gauge twisted pair shielded cable Black 5,000' [1,500m] max. Red Master Module Fuse (1 AMPw) Ground To Amico: Master Module or Building Management System - + NC C NC C NC C NC C NC C NC C NC C NC C U2 U6 U5 C H 10 C H 9 C H 8 C H 7 C H 6 C H 5 C H 4 C H 3 C H 2 C H U4 Source Equipment U3 SELECT/MUTE CHANGE DOWN CHANGE UP SETUP U S1 ON ON S2 B4 B3 B2 B1 Source Equipment Note: Jumper any unused points on the Master module. NOTE: Jumper any unused points on the Master module Turn OFF dip-switches for any unused points (Location SW-2) 24 Amico Corporation
25 Appendix G TECHNICAL SPECIFICATIONS Supply Voltage: Current Draw: Fuse (1/4 * 1-1/4): VAC, Hz 1 Amp. Max. Fast Blow 1 Amp. Cable requirement: LCD Alarm to Remote Sensor: Important: Cable: Belden # 8451 or equivalent. #22 gauge shielded, twisted pair. (For multiple sensors a multi-conductor twisted pair, shielded cable should be used). Distance: Maximum 100 ft [30.5 m] Signal: 30 VDC Amps. 60 VDC Amps. 125 VAC Amps. LCD Alarm to Master: Distance: Maximum 10,000 ft [3,000 m] Cable: Minimum #22 gauge wire Signal: 5 VDC - < 5 µa LCD Generic Alarm: Output: Dry Contacts NC, open on Alarm Rating: 30 VDC Amps. 60 VDC Amps. 125 VAC Amps. 25
26 26 Amico Corporation
27 27
28 Amico Corporation 85 Fulton Way, Richmond Hill Ontario, L4B 2N4, Canada Toll Free Tel: Toll Free Fax: Tel: Fax: APE-MANUAL-ALERT3-LCD
MICROPROCESSOR BASED DIGITAL ALARM SYSTEM
MICROPROCESSOR BASED DIGITAL ALARM SYSTEM ALERT- 2 Installation and Maintenance Manual v4.0 Table of Contents USER RESPONSIBILITY... 4 INTRODUCTION... 5 FEATURES... 6 DESCRIPTION OF THE ALARM... 7 SHIPMENT
Operating & Maintenance Manual. Alert-2 Microprocessor Based Digital Alarm System v5.9
Operating & Maintenance Manual Alert2 Microprocessor Based Digital Alarm System v5.9 w w w. a m i c o. c o m Contents User Responsibility 5 Introduction 5 6 Features Description of the Alarm Shipment Details
DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION
Form No. 74-00-4001 S168-527-001 Rev. B IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Allied Healthcare Products, Inc. s IMPACT alarms are designed
AMICO Information. Management System (AIMS)
AMICO Information Management System (AIMS) ALERT- 2 Installation and Maintenance Manual v 2.5 Table of Contents INTRODUCTION...3 Theory of Operation... 3 Network Diagram... 4 INSTALLATION... 5 Medical
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual
OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The
DC Series Digital Conversion Alarm Operator s Manual
DC Series Digital Conversion Alarm Operator s Manual Ver. 2012 - Rev. 1004 Class 1 Inc. design manufacture installation service world class innovation Call us for your next project. Area Alarm Conversion
Porter Instrument Division
AA173200i Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA Tel: 215-723-4000 Ref. 10545100 Rev. F CE Notice The symbol on this product indicates compliance
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Installation & Operating Instructions for DU / DC Series Area, Master & Combination Alarm Systems
Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for DU / DC Series Area, Master & Combination Alarm Systems Master Alarm Area Alarm Combination Alarm e5755ra 9/17/13
OHIO MEDICAL CORPORATION. Medical Gas Alarms. Installation and Maintenance Manual. Area Alarm. Master Alarm. Combo Alarm. P/N 255098 (Rev.
OHIO MEDICAL CORPORATION Medical Gas Alarms Installation and Maintenance Manual Area Alarm Master Alarm Combo Alarm P/N 255098 (Rev.8) 07/08 Page 2 NOTES Page 3 SQUIRE-COGSWELL COMPANY WAS FORMED IN 1916
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
Contractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION
GE Lighting Installation Instructions Lighting Controls Centralized Lighting Control Panel Interior Catalog Number CLCINTxx DESCRIPTION The Centralized Lighting Control System is a small network of relay
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07
PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 VANGUARD A OPERATOR S MANUAL FM-952 Rev.
Installation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
Installation and Operation Guide PD4600 Series Converter Replacement
Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your
VX 2400 Dimmer User's Manual
TM VX 2400 Dimmer User's Manual 21-2119C Manual Revision 1.01 Software Version 1.0 10 March 1994 Table of Contents 1. General Description...3 1.1. Standard Features:...3 2. Installing Options...4 2.1.
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions
Pub. 988-0064-351 LST-3800 In-Dash Digital Sonar Gauge Installation & Operation Instructions The LST-3800 is a depth and temperature gauge that comes with a 200 khz transducer, features deep and shallow
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
OPLC Installation Guide
Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
Remote Alarm Monitoring System
Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
INSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL HB6PAKX & HB6PAKXX HIDE-A-BLAST STANDARD HIDE A BLAST UNIT HB6PAK-PI-X NGPI TWIST LOCK HIDE-A-BLAST LED WARNING LIGHT NGPI TWIST LOCK HIDE A BLAST UNIT IMPORTANT: 6 LED
DC400 Dispensing Cutoff System
DC400 Dispensing Cutoff System DC404 and DC406 Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
Generator Transfer Switch Model # HTS15-AUTO
Generator Transfer Switch Model # HTS15-AUTO Congratulations on your purchase of our Single Circuit Generator Transfer Switch, We hope this meets and exceeds your expectations. If at anytime you have any
ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual
QUALITY STEAM SPECIALTIES SINCE ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual Section: C500 Bulletin: C500.40 Date: 06-26-01 Supersedes: New PRODUCT DESCRIPTION: The Clark-Reliance
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Pipeline. Medical Gas Pipeline Products
Pipeline Medical Gas Pipeline Products w w w. a m i c o. c o m The Amico Group Manufactures the Building Blocks of the Hospital Architectural Beds Lights Interiors Accessories Patient Care Diagnostic OR
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE LESTRONIC II BATTERY CHARGER FOR MOTIVE POWER BATTERIES PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.
Sense Components Sense monitor Antenna assembly External mounting kit Current sensors Download the Sense app. Go to sense.com/app Power cable Technical Specifications Sense is a home energy monitoring
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than
OPERATING INSTRUCTIONS
PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Installation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
Control Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Introduction:...5 Installation:...5
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
TSn SERIES Surge Protective Device
Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 [email protected] Fax 804.355.8900 Page: 2 of 8 Quick
OHIO MEDICAL CORPORATION. Medical Gas Outlets. Installation and Maintenance Manual
OHIO MEDICAL CORPORATION Medical Gas Outlets Installation and Maintenance Manual P/N PAGE 2 SQUIRE-COGSWELL COMPANY WAS FORMED IN 1916 AS A SUPPLIER OF RAILWAYAND FOUNDRY EQUIPMENT IN CHICAGO. IT CONTINUED
98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
ELECTRIC CONVECTION BUILT-IN OVEN
ENGLISH ESPAÑOL FRANÇAIS INSTALLATION MANUAL ELECTRIC CONVECTION BUILT-IN OVEN Please read these instructions thoroughly before installing and operating the oven. LWS3081ST LWD3081ST LSWS305ST LSWD305ST
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator