Improve the Speed of your System Startup
|
|
- Vernon Buddy Washington
- 7 years ago
- Views:
Transcription
1 Improve the Speed of your System Startup PowerLogic Factory Assembled Enclosures For metering, communications and control
2 Square D PowerLogic Factory Assembled Enclosures offer a wide range of designs for metering, communications, and control applications to simplify retrofit installations. Our enclosures are designed to order as a free-standing or wall-mounted system. With PowerLogic Factory Assembled Enclosures, you ll receive professionally crafted, factory tested, pre-wired enclosures that will greatly improve the speed of your system startup. All backed by the Square D quality standard of excellence. Service entrances and onsite generation Our Factory Assembled Enclosure units are available for your entire PowerLogic energy and power management system or automated power system controls project from the service entrance for revenue metering to high density tenant sub-metering and just about everything in between. If you don t see what you had in mind and would like to special order a custom enclosure, we offer design services to accommodate your needs. Power mitigation and main power distribution equipment Advantages: Designed to current NEC and UL standards Equipped with hazard and safety labels UL/CUL 508A listed* Efficient panel layout and well marked terminals reduce wiring errors and needless troubleshooting Complete with necessary documentation and mounting hardware for quick and easy installation PDUs and dataservers Processes, lines, machines or equipment Tenants, departments and subcontractors Engineering, planning, maintenance * Applies to sections 1-16.
3 Table of Contents Service Entrance/Utility Revenue Main/Critical Circuit Main + Multiple Feeders Meter (Qty) Display Type 12 Type 4 Type 1 Type 3R ION8600 meter (1) I 1 CM4000 series circuit monitor (1-4) R 2 ION7550 /ION7650 series meter (1-4) I 3 CM4000 series circuit monitors (1) + PM820 power meter (1-8) R + R 4 ION7550 /ION7650 series meters (1) + ION6200 series meter (1-8) I + R 5 Secondary Mains Feeders High Density Metering Communications Custom Enclosures Drawout Retrofit Cradles CM3000 series circuit monitor (1-4) R 6 ION7300 series meter (1-4) I or R 7 ION6200 series meter (1-4) R 8 PM820 power meter (1-4) R 9 ION6200 series power meter (1, 2, 4, 6, 8, 10, 12) PM800 series power meter (1, 2, 4, 6, 8, 10, 12) HDM - ION6200 series power meter (1 or 4) HDM - PM700 series power meter (1, 4, 8, 16) HDM - PM210 power meter (1, 4, 8, 16) R R Multiple Circuit Meter R or N 12 EGX (1) Ethernet switch (1) + EGX (1-3) I I I Light Industrial Applications 10 Commercial Building Applications 13 ION7550RTU (1-4) R or N 14 Niobrara Research & Development (NR&D) (1) 15 PM800 series power meter ION7300 series power meter ION6200 series power meter Controls 16 I I I I * Consult factory representative for special order. * ION6200 Only I = Integrated Display R = Remote Display N = No Display
4 1 Service Entrance/Revenue Utility PowerLogic ION8600 Factory Assembled Enclosures Type 3R Description: The ION8600 series socket meter enclosure is an ideal metering solution for monitoring electrical distribution networks, service entrances and substations requiring revenue accuracy and power quality analysis capabilities. This industrial enclosure is UL listed and equipped with pad-lockable latch and removable door. Multiple ION8600 units can be networked together via Ethernet or RS-485 using Modbus, ION or other industry standard communication protocols. Features Assemblies include meter and devices wired to terminal blocks, voltage disconnect and current transformer (CT) shorting block. Serial & Ethernet Communications are options for all units. Digital and/or Analog Input/Output (I/O) are options for all units. Units are available with optional 10-Pole test switch installed for voltage and CT testing, and calibration. Units are available with optional built in bar type CT s installed (Transocket Lever Bypass). Tailored to any meter system voltage type : 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Supports Single Voltage Sources for Outdoor (Type 3R) applications Wall mountable and easy to install, using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information
5 Service Entrance/Revenue Utility 1 Ordering Information Model Order code Description Factory Assembled: Type 3R ION 8600 Meter Enclosures 9761E Typical lead time is 6 - weeks Meter Meter Type (meter included with enclosure) 8600 ION8600 Meter Enclosure Type - Indoor/Outdoor Applications - NEMA 3R A0 B0 C0 D0 E0 NEMA 3R Enclosure with one 8xxx Form 9S (13 Terminal) meter Installed and Wired - Dim 20 H x 12 W x 5-1/8 D NEMA 3R Enclosure with one 8xxx Form 35S (8 Terminal) meter Installed and Wired - Dim 20 H x 12 W x 5-1/8 D NEMA 3R Enclosure with one 8xxx Form 36S (13 Terminal) meter Installed and Wired - Dim 20 H x 12 W x 5-1/8 D NEMA 3R Enclosure with one 8xxx Form 39S (15 Terminal) meter Installed and Wired - Dim 20 H x 12 W x 5-1/8 D NEMA 3R Enclosure with one 8xxx Form 76S (15 Terminal) meter Installed and Wired - Dim 20 H x 12 W x 5-1/8 D Enclosure Type - Transocket Lever Bypass Enclosure - Indoor / Outdoor Applications - NEMA 3R Bar Type CT s and Neutral Bar (if Applicable) are Located Behind a Protected Swing Door Supports CT Ratios 100, 200, 300 & 400:5 - Ratios must be Specified with Order F0 G0 NEMA 3R Enclosure with one 8xxx Form 9S (13 Terminal) meter Installed and Wired - Dim 34 H X 25 W X 13-1/4 D NEMA 3R Enclosure with one 8xxx Form 36S (13 Terminal) meter Installed and Wired - Dim 34 H X 25 W X 13-1/4 D Meter System Type - PT s are not included, CT s are only included for enclosure types F&G A Three Phase Voltage Disconnect and Control Power 1 (1) 3-Pole Fusible Disconnect provided for meter protection - meter powered off of socket blades. (1) 3-Pole Fusible Disconnect provided for meter protection with separate (1) 1-Pole Circuit Breaker provided for 2 (65-120VAC, VDC) auxiliary control power. CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s (form 9S, 35S) B 6 pole CT shorting block to accommodate 3 CT s (form 9S, 35S, 36S) C 8 pole CT shorting block to accommodate 4 CT s (form 39S, 76S) D 10 pole Test Switch to accommodate 3 CT s & Phase Voltages (form 9S, 35S, 36S) Digital & Analog Input/Output Wiring 1 None 2 3-Form A Digital Inputs, 4 form C Relay Outputs Wired to Terminal Blocks (18 TB s total) Analog Input/Output - None Communications Wiring A B C D None COM 1 and COM 2/4 Wired to Terminal Blocks (12 TB s total) 10BaseT Ethernet equipped meter CAT5E cable will terminate directly on meter. COM 1 and COM 2/4 Wired to Terminal Blocks (12 TB s total) 10BaseFL Ethernet equipped meter CAT5E fiber cables will terminate directly on meter. COM 1 and COM 2/4 Wired to Terminal Blocks (12 TB s total) Example: Part Number 9761E8600A0A1B1C 9761E 8600 A0 A 1 B 1 C
6 2 Main/Critical Circuit PowerLogic CM4250/4000T Factory Assembled Enclosures Type 12 & 4 Description: The CM4250 and CM4000T circuit monitor enclosures are an ideal metering solution for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities for critical loads. These pad-lockable, concealed hinge industrial enclosures are UL listed and are well suited for monitoring multiple services where the loads are fed from the same or separate voltage sources. CM4250 and CM4000T enclosure can monitor up to four separate sources/loads per panel utilizing one meter with remote display per load. Multiple CM4250 and CM4000T units can be networked together via Ethernet or RS-485 using Modbus communication protocol. Features Assemblies include meters and devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting block(s). Available with multiple meters per panel. Serial & Ethernet Communications are options for all units. Digital and/or Analog Input/Output (I/O) are options for all units. Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications. Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Equipped with concealed hinged door, and universal pad-lockable latch. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
7 Ordering Information Model Order code Description Factory Assembled: Type 12 & 4 CM4250 & 4000T Meter Enclosures Main/Critical Circuit E Typical lead time is 3 - Weeks Meter Meter Type - (meter is included with enclosure) 4250 CM4250 Remote Display Meter 4000 CM4000T Remote Display Meter Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 R1 NEMA 12 Enclosure with one meter with remote display Installed and Wired - Dim 24 H x 20 W x 10 D R2 NEMA 12 Enclosure with two meters with remote displays Installed and Wired - Dim 30 H x 24 W x 10 D R3 NEMA 12 Enclosure with three meters with remote displays Installed and Wired - Dim 36 H x 30 W x 10 D R4 NEMA 12 Enclosure with four meters with remote displays Installed and Wired - Dim 36 H x 30 W x 10 D Enclosure Type and Meter Quantity - Indoor/Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. Y1 Y2 Y3 Y4 NEMA 4 Enclosure with one meter with remote display Installed and Wired - Dim 24 H x 24 W x 12 D NEMA 4 Enclosure with two meters with remote displays Installed and Wired - Dim 30 H x 30 W x 12 D NEMA 4 Enclosure with three meters with remote displays Installed and Wired - Dim 36 H x 36 W x 12 D NEMA 4 Enclosure with four meters with remote displays Installed and Wired - Dim 42 H x 36 W x 12 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power - For Options on a per enclosure basis /For Options on a per meter basis All feeders must have the same Meter System Type - Otherwise a custom quote is required Example: Part Number 9761E4000R1C2B4C 9761E 4000 R1 C 2 B 4 C (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. Control power for meter derived directly from meter voltage inputs (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. 600/ V AC CPT provided for control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. Control power for meter derived directly from meter voltage inputs Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure 600/ VAC CPT provided for control power source CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s per meter B 6 pole CT shorting block to accommodate 3 CT s per meter C 8 pole CT shorting block to accommodate 4 CT s per meter Digital & Analog Input/Output Wiring 1 None 2 4 DI s and 2 DO s & 1 KYZ Output and 1 AO and 1 AI wired to terminal blocks (includes default I/O + IOX DC Supply) 3 4 DI s, 3 Relay Outputs, KYZ Output and 1 DO wired to terminal blocks (Includes Default I/O + IOC44 + DC Supply) 4 DI s, 3 Relay Outputs, KYZ Output and 3 DO s, 1AO and 1 AI wired to terminal blocks 4 Includes Default I/O + IOX2411+ IOC44 + DC Supply) Communications Wiring A No communications terminal blocks included. B COM 1 wired to 5 - Two Tier TB s (5-IN, 5-OUT) One 100BaseFX, 10/100Base T equipped meter. CAT5E & Fiber cables will terminate directly on the meter. RS-485 Port wired to C terminal blocks (5-OUT) for 5 TB s total. Note: For multi meter panels each meter s comm. ports will be daisy chained together and wired to terminal blocks for both incoming and outgoing termination. Units that have Ethernet will wire exactly the same except the incoming 4-wire terminal blocks will be replaced by the meters comm. port for that network.
8 Main/Critical Circuit 3 PowerLogic ION7550/7650 Factory Assembled Enclosures Type 12 & 4 Description: The ION7550 and ION7650 metering enclosures are an ideal metering solution for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities. These pad-lockable, concealed hinge industrial enclosures are UL listed and well suited for monitoring multiple services where the loads are fed from the same or separate voltage sources. ION7550/7650 enclosures contain integrated display meters capable of monitoring up to four separate sources/loads per panel utilizing one meter per load. Features Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting block(s). Available with multiple meters per panel. Serial & Ethernet Communications are options for all units Digital and/or Analog Input/Output (I/O) are options for all units. Tailored to any meter system voltage type : 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications. Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
9 Main/Critical Circuit 3 Ordering Information 9761E Model Order code Description Meter Factory Assembled: Type 12 & 4 ION7550 & ION7650 Meter Enclosures Typical lead time is 5 - Weeks for this offering Meter Type (meter is included with enclosure) 7550 ION7550 Integrated Display Meter 7650 ION7650 Integrated Display Meter Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 A1 NEMA 12 Enclosure with one integrated display meter Installed and Wired - Dim 20 H x 16 W x 12 D A2 NEMA 12 Enclosure with two integrated display meters Installed and Wired - Dim 24 H x 24 W x 10 D A3 NEMA 12 Enclosure with three integrated display meters Installed and Wired - Dim 30 H x 30 W x 10 D A4 NEMA 12 Enclosure with four integrated display meters Installed and Wired - Dim 36 H x 30 W x 10 D Enclosure Type and Meter Quantity - Indoor / Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. X1 NEMA 4 Enclosure with one integrated display meter Installed and Wired - Dim 24 H x 20 W x 12 D X2 NEMA 4 Enclosure with two integrated display meters Installed and Wired - Dim 30 H x 24 W x 12 D X3 NEMA 4 Enclosure with three integrated display meters Installed and Wired - Dim 36 H x 30 W x 12 D X4 NEMA 4 Enclosure with four integrated display meters Installed and Wired - Dim 36 H x 36 W x 12 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power - For Options on a per enclosure basis /For Options on a per meter basis All feeders must have the same Meter System Type - Otherwise a custom quote is required (1) 3-Pole Fusible Disconnect provided for protection of all meters in enclosure. Control power for meter derived directly from 1 meter voltage inputs (1) 3-Pole Fusible Disconnect provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC 2 separate control power source (1) 3-Pole Fusible Disconnect provided for protection of all meters in enclosure. 600/ VAC CPT provided for control power 3 source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. Control power for meter 4 derived directly from meter voltage inputs Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. (1) 1-Pole Circuit Breaker 5 provided for 120VAC separate control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. 600/ VAC CPT provided 6 for control power source CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s per meter B 6 pole CT shorting block to accommodate 3 CT s per meter C 8 pole CT shorting block to accommodate 4 CT s per meter Digital & Analog Input/Output Wiring 1 None 2 8 DI s, 4 DO s and 3 Relay Outputs wired to terminal blocks (33 TB s) per meter 3 16 DI s wired to terminal blocks & 4 Al s and 4 AO s wired to terminal blocks (56 TB s) per meter 4 16 DI s, 4 DO s & 3 Relay Outputs wired to terminal blocks and 4 AI s & 4 AO s wired to terminal blocks (73 TB s) per meter Communications Wiring A No communications terminal blocks included B COM 1 and COM 2 wired to 6 terminal blocks (3-IN, 3-OUT each COM port) for 12 TB s total One 10BaseT Ethernet & 10BaseFL equipped meter. CAT5E & Fiber cables will terminate directly on meter. COM 1 and COM 2 wired to C 6 terminal clocks (3-IN, 3-OUT each COM port) for 12 TB s total Example: Part Number 9761E7650A1A1C4C 9761E 7650 A1 A 1 C 4 C Note: For multi-meter panels for each RS-485 network there will be 3 TB s for incoming COMMs to first meter and 3 TB s for outgoing COMMs off test meter. Each meter in panel will be daisy chained together.
10 Main + Multiple feeders 4 PowerLogic CM4250/4000T Main with PM820 Feeder Factory Assembled Enclosures Type 12 & 4 Description: The CM4250/4000T Main with PM820 feeder enclosure is an ideal metering solution for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities. These pad-lockable enclosures are UL listed and offer an integrated solution that is well suited for monitoring the main service as well as multiple loads. These main plus feeder units allow for primary main service voltage monitoring in addition to separate voltage monitoring for the loads which share the same voltage source. Each unit is capable of monitoring up to one main service and eight separate loads per panel utilizing one meter per load. Multiple units can be networked together via Ethernet or RS-485 using Modbus communication protocol. Features Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and 8-pole current transformer (CT) shorting block(s) on the main and 6-pole CT shorting blocks on feeders. Available with multiple meters per panel. Main meter and feeders will be wired for Inputs/Outputs. 8-Digital Inputs, 3-Relay Outs, KYZ Out, 3-Digital Outputs, 1-Analog Output, 1-Analog Input wired to terminal blocks (Includes default I/O + IOX IOC44 + DC supply). Each feeder will have 1-Digital Input, and 1-Digital Output wired to terminal blocks. (Includes Feeder default I/O only) One 100BaseFX, 10/100BaseT equipped meter. CAT5E & Fiber cabinet will terminate directly on the meter. Each meter RS-485 port will be daisy chained together, and wired to terminal blocks (5 OUT for 5 terminal blocks total). Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures, if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
11 Main + Multiple feeders 4 Ordering Information Factory Assembled: Single Main - Multi Feeder Monitoring Panels - Type 12 & 4 CM4250 & CM4000T Main with PM820 Feeder Metering Enclosures Model Order code Description 9761M Typical lead time is 4 - Weeks This Enclosure offer utilizes remote display meters on the Main & Remote displays on the feeders Meter Meter Type (meters are included with enclosure) 4250 CM4250 Circuit Monitor with CMDVF & CMDGN12, IOX2411, IOC44 and ECC CM4000T Circuit Monitor with CMDVF & CMDGN12, IOX2411, IOC44 and ECC21 F82 PM820 Remote Display Meter. One per feeder Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 R1 NEMA 12 Enclosure with one Main and one Feeder meter Installed and Wired - Dim 24 H x 24 W x 10 D R2 NEMA 12 Enclosure with one Main and two Feeder meters Installed and Wired - Dim 30 H x 24 W x 10 D R3 NEMA 12 Enclosure with one Main and three Feeder meters Installed and Wired - Dim 30 H x 24 W x 10 D R4 NEMA 12 Enclosure with one Main and four Feeder meters Installed and Wired - Dim 30 H x 30 W x 10 D R5 NEMA 12 Enclosure with one Main and five Feeder meters Installed and Wired - Dim 30 H x 30 W x 10 D R6 NEMA 12 Enclosure with one Main and six Feeder meters Installed and Wired - Dim 36 H x 30 W x 10 D R7 NEMA 12 Enclosure with one Main and seven Feeder meters Installed and Wired - Dim 36 H x 30 W x 10 D R8 NEMA 12 Enclosure with one Main and eight Feeder meters Installed and Wired - Dim 36 H x 30 W x 10 D Enclosure Type and Meter Quantity - Indoor/Outdoor - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Example: Part Number 9671E4000F82R3A2 9761M 4000 F82 R3 A 2 NEMA 4 Enclosure with one Main and one Feeder meter Installed and Wired - Dim 30 H x 24 W x 12 D NEMA 4 Enclosure with one Main and two Feeder meters Installed and Wired - Dim 30 H x 24 W x 12 D NEMA 4 Enclosure with one Main and three Feeder meters Installed and Wired - Dim 30 H x 30 W x 12 D NEMA 4 Enclosure with one Main and four Feeder meters Installed and Wired - Dim 30 H x 30 W x 12 D NEMA 4 Enclosure with one Main and five Feeder meters Installed and Wired - Dim 36 H x 30 W x 12 D NEMA 4 Enclosure with one Main and six Feeder meters Installed and Wired - Dim 36 H x 30 W x 12 D NEMA 4 Enclosure with one Main and seven Feeder meters Installed and Wired - Dim 36 H x 30 W x 12 D NEMA 4 Enclosure with one Main and eight Feeder meters Installed and Wired - Dim 36 H x 36 W x 12 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power (2) 3-Pole Fusible Disconnects (1-for Main & 1-for Feeders) provided for protection of all meters in enclosure. Control power for 1 meter derived directly from meter voltage inputs 2 3 (2) 3-Pole Fusible Disconnects (1-for Main & 1-for Feeders) provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source for all meters (2) 3-Pole Fusible Disconnects (1-for Main & 1-for Feeders) provided for protection of all meters in enclosure. 600/ VAC CPT provided for control power source derived from Main meter voltage inputs
12 Main + Multiple feeders 5 PowerLogic ION7550/7650 Main with ION6200 Feeder Factory Assembled Enclosures Type 12 & 4 Description: The ION75/7650 Main with ION6200 Feeder enclosure is an ideal metering solution for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities. These pad-lockable enclosures are UL listed and offer an integrated solution that is well suited for monitoring the main service as well as multiple loads. These main plus feeder units allow for primary main service voltage monitoring in addition to separate voltage monitoring for the loads which share the same voltage source. Each unit is capable of monitoring up to one main service and eight separate loads per panel utilizing one meter per load. Multiple units can be networked together via Ethernet or RS-485 using Modbus, ION or other industry standard communication protocols. Features Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and 8-pole current transformer (CT) shorting block on main and 6-pole CT shorting blocks on feeders. Available with multiple meters per panel. Main meter will be wired for Inputs/Outputs, feeders will not. 16 Digital Inputs, 4 Digital Outputs, and 3 Relay OUtputs wired to terminal blocks and 4 Analog Inputs and 4 Analog Outputs wired to terminal blocks. One 10 Base-T Ethernet and 10 Base-FL equipped meter. CAT 5E and fiber cables will terminate directly on meter. Each RS-485 port will be daisy chained together and wired to terminal blocks. Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
13 Ordering Information Main + Multiple feeders 5 Factory Assembled: Single Main - Multi Feeder Monitoring Panels - Type 12 & 4 ION7550 & ION7650 Main with ION6200 Feeder Metering Enclosures Model Order code Description 9761M Typical lead time is 6 - Weeks This Enclosure offer utilizes integrated display meters on the Main & Remote displays on the feeders Meter Meter Type (meters are included with enclosure) 7550 ION7550 Integrated Display Meter with expanded communications and I/O (Ethernet 10BaseT, 10BaseFL) 7650 ION7650 Integrated Display Meter with expanded communications and I/O (Ethernet 10BaseT, 10BaseFL) F62 ION6200 Remote Display Meter. One per feeder Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 R1 NEMA 12 Enclosure with one Main and one Feeder meter Installed and Wired - Dim 24 H x 24 W x 10 D R2 NEMA 12 Enclosure with one Main and two Feeder meters Installed and Wired - Dim 30 H x 24 W x 10 D R3 NEMA 12 Enclosure with one Main and three Feeder meters Installed and Wired - Dim 30 H x 24 W x 10 D R4 NEMA 12 Enclosure with one Main and four Feeder meters Installed and Wired - Dim 30 H x 30 W x 10 D R5 NEMA 12 Enclosure with one Main and five Feeder meters Installed and Wired - Dim 30 H x 30 W x 10 D R6 NEMA 12 Enclosure with one Main and six Feeder meters Installed and Wired - Dim 36 H x 30 W x 10 D R7 NEMA 12 Enclosure with one Main and seven Feeder meters Installed and Wired - Dim 36 H x 30 W x 10 D R8 NEMA 12 Enclosure with one Main and eight Feeder meters Installed and Wired - Dim 36 H x 30 W x 10 D Enclosure Type and Meter Quantity - Indoor / Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Example: Part Number 9761M7650F62R8C2 9761M 7650 F62 R8 C 2 NEMA 4 Enclosure with one Main and one Feeder meter Installed and Wired - Dim 30 H x 24 W x 12 D NEMA 4 Enclosure with one Main and two Feeder meters Installed and Wired - Dim 30 H x 24 W x 12 D NEMA 4 Enclosure with one Main and three Feeder meters Installed and Wired - Dim 30 H x 30 W x 12 D NEMA 4 Enclosure with one Main and four Feeder meters Installed and Wired - Dim 30 H x 30 W x 12 D NEMA 4 Enclosure with one Main and five Feeder meters Installed and Wired - Dim 36 H x 30 W x 12 D NEMA 4 Enclosure with one Main and six Feeder meters Installed and Wired - Dim 36 H x 30 W x 12 D NEMA 4 Enclosure with one Main and seven Feeder meters Installed and Wired - Dim 36 H x 30 W x 12 D NEMA 4 Enclosure with one Main and eight Feeder meters Installed and Wired - Dim 36 H x 36 W x 12 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power - For options on a per enclosure basis All feeders must have the same Meter System Type - Otherwise a custom quote is required (2) 3-Pole Fusible Disconnects (1-for Main & 1-for Feeders) provided for protection of all meters in enclosure. Control power for 1 meter derived directly from meter voltage inputs 2 3 (2) 3-Pole Fusible Disconnects (1-for Main & 1-for Feeders) provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source for all meters (2) 3-Pole Fusible Disconnects (1-for Main & 1-for Feeders) provided for protection of all meters in enclosure. 600/ VAC CPT provided for control power source derived from Main meter voltage inputs
14 Secondary Mains 6 PowerLogic CM3000 Series Factory Assembled Enclosures Type 12 & 4 Description: The CM3250 and CM3350 enclosures are an ideal metering solution for monitoring key distribution points and sensitive loads requiring both revenue accuracy and power quality analysis capabilities. These pad-lockable enclosures are UL listed and well suited for monitoring multiple services where the loads are fed from the same or separate voltage source(s). CM3250 and CM3350 enclosures with remote display meters are capable of monitoring four separate sources/loads per panel utilizing one meter per load. Multiple CM3250 and CM3350 units can be networked together via Ethernet or RS-485 using Modbus communications protocol. Features Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting block(s). Available with multiple meters per panel. Serial & Ethernet Communications are options for all units. Digital and/or Analog Input/Output (I/O) are options for all units. Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications. Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
15 Ordering Information Model Order code Description Factory Assembled: Type 12 & 4 CM3250 & CM3350 Meter Enclosures Secondary Mains E Typical lead time is 3 - Weeks Nameplates Available Upon Request (Provide Nameplate Schedule With Order) Meter Meter Type (meter is included with enclosure) 3250 CM3250 Remote Display Meter 3350 CM3350 Remote Display Meter Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 R1 NEMA 12 Enclosure with one meter with remote display Installed and Wired - Dim 24 H x 20 W x 10 D R2 NEMA 12 Enclosure with two meters with remote displays Installed and Wired - Dim 30 H x 24 W x 10 D R3 NEMA 12 Enclosure with three meters with remote displays Installed and Wired - Dim 30 H x 30 W x 10 D R4 NEMA 12 Enclosure with four meters with remote displays Installed and Wired - Dim 36 H x 30 W x 10 D Enclosure Type and Meter Quantity - Indoor/Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. Y1 Y2 Y3 Y4 NEMA 4 Enclosure with one meter with remote display Installed and Wired - Dim 24 H X 24 W X 12 D NEMA 4 Enclosure with two meters with remote displays Installed and Wired - Dim 30 H X 30 W X 12 D NEMA 4 Enclosure with three meters with remote displays Installed and Wired - Dim 36 H X 30 W X 12 D NEMA 4 Enclosure with four meters with remote displays Installed and Wired - Dim 36 H X 36 W X 12 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power - For Options on a per enclosure basis /For Options on a per meter basis All feeders must have the same Meter System Type - Otherwise a custom quote is required Example: Part Number 9761E3350Y1A2B1C 9761E 3350 Y1 A 2 B 1 C (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. Control power for meter derived directly from meter voltage inputs (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. 600/ V AC CPT provided for control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. Control power for meter derived directly from meter voltage inputs Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure 600/ VAC CPT provided for control power source CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s per meter B 6 pole CT shorting block to accommodate 3 CT s per meter C 8 pole CT shorting block to accommodate 4 CT s per meter Digital & Analog Input/Output Wiring - Option 2 not available with Comm. Option C 1 None 2 4 DI s, 3 Relay Outputs, KYZ Output and 1 DO wired to terminal blocks (Includes Default I/O + IOC44 + DC Supply) per meter Communications Wiring A No communications terminal blocks included. B COM 1 wired to 5 - Two Tier TB s (5-IN, 5-OUT) One 100BaseFX, 10/100BaseT equipped meter. CAT5E & Fiber cables will terminate directly on the meter. RS-485 Port wired C to terminal blocks (5-OUT) for 5 TB s total. Note: For multi meter panels each meter s comm. ports will be daisy chained together and wired to terminal blocks for both incoming and outgoing termination. Units that have Ethernet will wire exactly the same except the incoming 4-wire terminal blocks will be replaced by the meters comm. port for that network.
16 Secondary Mains 7 PowerLogic ION7300 Series Factory Assembled Enclosures Type 12 & 4 Description: The ION7300 series enclosures are and ideal metering solution for high accuracy feeder monitoring and secondary mains. These pad-lockable enclosures are UL listed and well suited for monitoring multiple loads fed from the same or separate voltage sources. ION7300 series enclosures are capable of monitoring up to four separate sources/loads per panel utilizing one remote display or integrated display meter per load. Multiple ION7300 series units can be networked together via Ethernet or RS-485 using Modbus, ION or other industry standard communication protocols. Features Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting block(s). Available with multiple meters per panel. Serial & Ethernet Communications are options for all units. Digital and/or Analog Input/Output (I/O) are options for all units. Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
17 Ordering Information 9761E Model Order code Description Meter Factory Assembled: Type 12 & 4 ION7300, ION7330 & ION7350 Meter Enclosures Typical lead time is 6 - Weeks Meter Type - (meter is included with enclosure) 7300 ION7300 Remote or Integrated Display Meter 7330 ION7330 Remote or Integrated Display Meter 7350 ION7350 Remote or Integrated Display Meter Secondary Mains Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 A1 NEMA 12 Enclosure with one meter with integrated display Installed and Wired - Dim 20 H x 16 W x 12 D A2 NEMA 12 Enclosure with two meters with integrated displays Installed and Wired - Dim 20 H x 20 W x 12 D A3 NEMA 12 Enclosure with three meters with integrated displays Installed and Wired - Dim 24 H x 20 W x 10 D A4 NEMA 12 Enclosure with four meters with integrated displays Installed and Wired - Dim 24 H x 24 W x 10 D R1 NEMA 12 Enclosure with one meter with remote display Installed and Wired - Dim 20 H x 16 W x 12 D R2 NEMA 12 Enclosure with two meters with remote displays Installed and Wired - Dim 24 H x 20 W x 10 D R3 NEMA 12 Enclosure with three meters with remote displays Installed and Wired - Dim 24 H x 24 W x 10 D R4 NEMA 12 Enclosure with four meters with remote displays Installed and Wired - Dim 30 H x 24 W x 10 D Enclosure Type and Meter Quantity - Indoor/Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. X1 NEMA 4 Enclosure with one meter with integrated display Installed and Wired - Dim 20 H x 20 W x 12 D X2 NEMA 4 Enclosure with two meters with integrated displays Installed and Wired - Dim 24 H x 20 W x 12 D X3 NEMA 4 Enclosure with three meters with integrated displays Installed and Wired - Dim 24 H x 24 W x 10 D X4 NEMA 4 Enclosure with four meters with integrated displays Installed and Wired - Dim 30 H x 24 W x 10 D Y1 NEMA 4 Enclosure with one meter with remote display Installed and Wired - Dim 20 H x 20 W x 12 D Y2 NEMA 4 Enclosure with two meters with remote displays Installed and Wired - Dim 24 H x 24 W x 12 D Y3 NEMA 4 Enclosure with three meters with remote displays Installed and Wired - Dim 30 H x 24 W x 12 D Y4 NEMA 4 Enclosure with four meters with remote displays Installed and Wired - Dim 30 H x 30 W x 12 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power For Options on a per enclosure basis /For Options on a per meter basis All feeders must have the same Meter System Type - Otherwise a custom quote is required 1 (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. Control power for meter derived directly from meter voltage inputs 2 (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source 3 (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. 600/ V AC CPT provided for control power source 4 Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. Control power for meter derived directly from meter voltage inputs 5 Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source. 6 Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure 600/ VAC CPT provided for control power source CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s per meter B 6 pole CT shorting block to accommodate 3 CT s per meter Digital & Analog Input/Output Wiring (Available on integrated display meters only. A and X Enclosure Types) 1 None 2 4 DI s and 4 DO s wired to terminal blocks (16 TB s) per Meter 3 4 AI s and 4 AO s wired to terminal blocks (24 TB s) per Meter 4 4 DI s and 4 DO s wired to terminal blocks & 4 AI s and 4 AO s wired to terminal blocks (40 TB s) per meter Communications Wiring A No communications terminal blocks included. B COM 1 and COM 2 wired to 6 terminal blocks (3-IN, 3-OUT each COM port) for 12 TB s total C One Ethernet equipped meter. CAT5E cable will terminate directly on meter. COM 1 and COM 2 wired to 6 terminal blocks (3-IN, 3-OUT each COM port) for 12 TB s total Note: For multi meter panels each meter s comm. ports will be daisy chained together and wired to terminal blocks for both incoming and outgoing termination. Units that have Ethernet will wire exactly the same except the incoming 2-wire terminal blocks will be replaced by the meters comm. port for that network. Example: Part Number 9761E7350R1C3B1C 9761E 7350 R1 C 3 B 1 C 7
18 Feeders 8 PowerLogic ION6200 Factory Assembled Enclosures Type 12 & 4 Description: The ION6200 enclosures are an ideal metering solution for high accuracy feeder monitoring and submetering. These pad-lockable enclosures are UL listed and well suited for monitoring multiple services where the loads are fed from the same or separate voltage sources. ION6200 enclosures are capable of monitoring up to four separate sources/loads per panel utilizing one meter with remote display per load. Multiple ION6200 units can be networked together via Ethernet or RS-485 using Modbus, ION or other industry standard communication protocols. Feautures Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting block(s). Available with multiple meters per panel. Serial & Ethernet Communications are options for all units. Digital and/or Analog Input/Output (I/O) are options for all units. Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications. Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
19 Feeders 8 Ordering Information Factory Assembled: Type 12 & 4 ION6200 Meter Enclosures Model Order code Description 9761E Typical lead time is 3 - Weeks Meter Meter Type (meter is included with enclosure) 6200 ION6200 Remote Display Meter Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 R1 NEMA 12 Enclosure with one meter with remote display Installed and Wired - Dim 20 H x 16 W x 8 D R2 NEMA 12 Enclosure with two meters with remote displays Installed and Wired - Dim 24 H x 20 W x 8 D R3 NEMA 12 Enclosure with three meters with remote displays Installed and Wired - Dim 24 H x 24 W x 8 D R4 NEMA 12 Enclosure with four meters with remote displays Installed and Wired - Dim 30 H x 24 W x 8 D Enclosure Type and Meter Quantity - Indoor/Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote. Y1 Y2 Y3 Y4 NEMA 4 Enclosure with one meter with remote display Installed and Wired - Dim 24 H x 20 W x 10 D NEMA 4 Enclosure with two meters with remote displays Installed and Wired - Dim 30 H x 24 W x 10 D NEMA 4 Enclosure with three meters with remote displays Installed and Wired - Dim 30 H x 30 W x 10 D NEMA 4 Enclosure with four meters with remote displays Installed and Wired - Dim 36 H x 30 W x 10 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power - For Options on a per enclosure basis /For Options on a per meter basis All feeders must have the same Meter System Type - Otherwise a custom quote is required (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. Control power for meter derived directly from 1 meter voltage inputs Example: Part Number: 9761E6200R1A2B1B 9761E 6200 R1 A 2 B 1 B (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. 600/ V AC CPT provided for control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. Control power for meter derived directly from meter voltage inputs Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source. Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure 600/ VAC CPT provided for control power source CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s per meter B 6 pole CT shorting block to accommodate 3 CT s per meter Digital & Analog Input/Output Wiring (Available on integrated display meters only. A and X Enclosure Types) 1 None 2 2 DO s wired to terminal blocks (2 TB s) per Meter. Analog I/O - None Communications Wiring A No communications terminal blocks included B COM 1 wired to 6 terminal blocks (3-IN, 3-OUT) C EGX100 with power supply wired to Com1 and terminal blocks (3-out) modbus protocol only. Note: For multi meter panels each meter s comm. ports will be daisy chained together and wired to terminal blocks for both incoming and outgoing termination. Units that have Ethernet will wire exactly the same except the incoming 2-wire terminal blocks will be replaced by the meters comm. port for that network.
20 Feeders 9 PowerLogic PM800 Series Factory Assembled Enclosures Type 12 & 4 Description: The PM800 series enclosures are an ideal metering solution for high accuracy feeder monitoring and submetering. These pad-lockable enclosures are UL listed and well suited for monitoring multiple loads fed from the same or separate voltage sources. PM800 series enclosures are capable of monitoring up to four separate sources/loads per panel utilizing one remote display meter per load. Multiple PM800 series units can be networked together via Ethernet or RS-485 using Modbus communication protocol. Features Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s) and current transformer (CT) shorting block(s). Available with multiple meters per panel. Serial & Ethernet Communications are options for all units. Digital and/or Analog Input/Output (I/O) are options for all units. Tailored to any meter system voltage type: 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase 240V, 480V & 600V Delta Three-Phase Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications Wall mountable and easy to install using concealed holes in the back of the enclosure. Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish. Custom engraved nameplates are available for all units. Enclosure Dimensions - see ordering information Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.
21 Ordering Information 9761E Model Order code Description Factory Assembled: Type 12 & 4 PM810, PM820, PM850 & PM870 Meter Enclosures Typical lead time is 3 - Weeks Nameplates Available Upon Request (Provide Nameplate Schedule With Order) Meter Meter Type (meter is included with enclosure) 0810 PM810 Remote Display Meter 0820 PM820 Remote Display Meter 0850 PM850 Remote Display Meter 0870 PM870 Remote Display Meter Enclosure Type and Meter Quantity - Indoor Applications - NEMA 12 R1 NEMA 12 Enclosure with one meter with remote display Installed and Wired - Dim 20 H x 16 W x 8 D R2 NEMA 12 Enclosure with two meters with remote displays Installed and Wired - Dim 24 H x 20 W x 8 D R3 NEMA 12 Enclosure with three meters with remote displays Installed and Wired - Dim 24 H x 24 W x 8 D R4 NEMA 12 Enclosure with four meters with remote displays Installed and Wired - Dim 30 H x 24 W x 8 D Enclosure Type and Meter Quantity - Indoor/Outdoor Applications - NEMA 4 Note: All units are equipped with a strip heater to prevent condensation. If further environmental controls are required Cooling a custom design will be required. Please consult with engineering for a quote.e. Y1 Y2 Y3 Y4 NEMA 4 Enclosure with one meter with remote display Installed and Wired - Dim 24 H x 20 W x 10 D NEMA 4 Enclosure with two meters with remote displays Installed and Wired - Dim 30 H x 24 W x 10 D NEMA 4 Enclosure with three meters with remote displays Installed and Wired - Dim 30 H x 30 W x 10 D NEMA 4 Enclosure with four meters with remote displays Installed and Wired - Dim 36 H x 30 W x 10 D Meter System Type - PT s and CT s are not included A Three Phase - 208Y/120V WYE B Three Phase - 240V DELTA C Three Phase - 480Y/277V WYE D Three Phase - 480V DELTA E Three Phase - 600Y/347V WYE F Three Phase - 600V DELTA Voltage Disconnect and Control Power - For Options on a per enclosure basis /For Options on a per meter basis All feeders must have the same Meter System Type - Otherwise a custom quote is required (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. Control power for meter derived directly from 1 meter voltage inputs Example: Part Number 9761E0820R1C3B5C 9761E 0820 R1 C 3 B 5 C (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source (1) 3-Pole Fusible disconnect provided for protection of all meters in enclosure. 600/ V AC CPT provided for control power source Feeders Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure. Control power for meter derived directly from meter voltage inputs Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure (1) 1-Pole Circuit Breaker provided for 120VAC separate control power source Multiple Voltage Sources - 3-Pole Fusible disconnect provided for protection of each meter in enclosure 600/ VAC CPT provided for control power source CT Shorting Block A 4 pole CT shorting block to accommodate 2 CT s per meter B 6 pole CT shorting block to accommodate 3 CT s per meter Digital & Analog Input/Output Wiring 1 None (No I/O Wiring Provided) 2 1 DI and 1 DO wired to terminal blocks (2 TB s) (Default I/O + DC Supply) per meter 3 3 DI s and 3 DO s wired to terminal blocks (6 TB s) (Includes default I/O + PM8M22 + DC Supply) per meter 4 7 DI s and 3 DO s wired to terminal blocks (10 TB s) (Includes default I/O + PM8M22) per meter 2 AI s and 2 AO s wired to terminal blocks & 3 DI s and 3 DO s wired to terminal blocks (14 TB s) 5 Includes Default I/O + PM8M22 + DC Supply) per meter Communications Wiring A B C No communications terminal blocks included Both RS-485 ports wired to TB s 2-Wire port wired to 3-Two Tier TB s (3-IN, 3-OUT) & 4-Wire port wired to 5-Two-Tier TB s (5-IN, 5-OUT) One Ethernet equipped meter. CAT5E cable will terminate directly on meter. 4-Wire port will be wired to terminal blocks (5-OUT) Note: For multi meter panels each meter s comm. ports will be daisy chained together and wired to terminal blocks for both incoming and outgoing termination. Units that have Ethernet will wire exactly the same except the incoming 4-wire terminal blocks will be replaced by the meters comm. port for that network. 9
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design
Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,
More informationSimple Electrical Utility Cost Allocation Solutions
Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationTHERMAL MANAGEMENT SOLUTIONS
t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single
More informationSwitchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR
Switchgear Capabilities NexGear is a Division of PowerSecure NASDAQ: POWR Discussion Points Introducing PowerSecure Introducing NexGear Solutions Offered Scope of Services Examples of Work Q & A NexGear,
More informationSECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationSUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
More informationDigital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
More information2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationSquare D Model 6 Motor Control Centers
Square D Model 6 Motor Control Centers with Ethernet Communications What is industrial Ethernet? Over the past few years the use of Ethernet communications has spread into every corner of the business
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationSmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings
Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationPOWERLOGIC Circuit Monitor Series 2000
Class POWERLOGIC Circuit Monitor Series 2000 Features True rms metering Certified ANSI C2.6 revenue accuracy High accuracy 0.2% current and voltage Power quality readings THD, k-factor, crest factor Over
More informationTable of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
More informationSWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More informationFFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
More informationUsing installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
More informationMini Power-Zone Unit Substation
Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3
More informationMAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
More informationCase Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide
Case Study - University at Buffalo State University of New York Lower Energy Usage Costs with Real Time Monitoring, Campus-wide Reduce Energy Consumption through Awareness of Energy Use Analyze Power Quality
More informationWiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
More informationSM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
More informationPART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
More informationSECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General
SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General A. Electrical usage on the Brown campus is presently monitored by a Siemens-brand, web-based central metering system, which includes
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationomega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box 1 3/29/2010 Rev.0 DOC-OMEGABB9MAN 2 Introduction FMA1600-MDB Multi-Drop Box Operating Bulletin The FMA1600-MDB Multi-Drop Box
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationPS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS
More informationPowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
More informationIPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationOVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
More informationSECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationMini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications
Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationMCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
More informationElectronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationPump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
More informationLEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems
LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the
More informationAC and DC Drive System Installation Information
Purpose This document contains the Parker SSD Drives recommendations for installing drive systems. These instructions must be followed for safe and reliable operation. Instructions CODES AND REGULATIONS
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More information* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
More informationPower quality monitoring and analysis with reliability
Power quality monitoring and analysis with reliability PowerLogic CM4000 series circuit monitors Buildings Industry Data Center Intelligent metering and control devices Whether in offices, classrooms,
More informationEMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
More informationMETER REQUIREMENTS GENERAL REQUIREMENTS SECTION D
12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More informationOVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
More informationHVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability
HVL 5 38 kv Load Interrupter Switchgear The Standard for Performance, Protection and Dependability For a generation of engineers, Square D High Voltage Load (HVL ) Interrupter Switchgear by Schneider Electric
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
More informationMultilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.
GE Grid Solutions Multilin EPM 6000 High Accuracy Power & Energy Measurement The Multilin EPM 6000 is one of the industry s highest performance revenue grade panel meters with superior cost to performance
More informationRemote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More informationSubstation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationHM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
More informationMetering for today s systems
Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single
More informationELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationLVA Take Offs in Bid Manager
Electrical Sales and Distributor Training Low Voltage Assemblies (LVA) LVA Take Offs in Bid Manager This job aid helps to define some of the common selection questions that are encountered when configuring
More informationOwner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
More informationAutomation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
More informationMidNite Solar E-Panels Explained
MidNite Solar E-Panels Explained A MidNite Solar E-panel is an AC/DC Disconnect Box that has the Inverter installed on the door of the E-Panel or above the E-panel. MidNite's E-Panels place the AC and
More informationInstallation Guide Solar Connect-11
Installation Guide Solar Connect-11 Version 1.1 Contents Important Product Information 3 System Registration Form 4 Solar Connect-11 Overview 5 Internet & Power Connections 6 Single Phase CT Connections
More informationServer Technology Intl.
Server Technology, Inc. 3-Phase Power in the Data Center White Paper STI-100-005 North America/ASIA EMEA Server Technology, Inc. Server Technology Intl. 1040 Sandhill Drive Sienna Court Reno, NV 89521
More informationLearning Module 13: Panelboards and Switchboards. 101 Basic Series
Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and
More informationWhite Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
More informationSuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1
SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More information920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
More informationSample - No Commercial Use
COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationDevice Support in PowerLogic ION Enterprise 5.6 Service Pack 2
70072-0189-00 TECHNICAL 08/2008 Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2 This document outlines support in ION Enterprise 5.6 Service Pack 2 for PowerLogic CM3000 series/cm4000 series,
More informationApplications. Remote Display Mounting Kits
June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge
More informationAdvanced Heat-Tracing Control System
Advanced Heat-Tracing Control System Product Overview Heat-tracing system NGC-30 system Remote configuration and monitoring with Raychem Supervisor software The Raychem NGC-30 is a multi-circuit electronic
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationREAD THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
More informationSECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)
PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationSeries TS 870 100-1200 Amp. Automatic Transfer Switches
Series TS 870 100-1200 Amp Automatic Transfer Switches A Regal Brand TS 870 AUTOMATIC TRANSFER SWITCHES THOMSON POWER SYSTEMS TS 870 AUTOMATIC TRANSFER SWITCHES OFFER THE FOLLOWING OUTSTANDING FEATURES:
More informationAddendum #2 Contract UK-11-13
Addendum #2 Contract UK-11-13 Utilities Kingston Purchase and Replacement of Switchgear at Kingston Hydro Substation MS11 March 25, 2011 Delivered to: All RFP recipients Total number of pages: Nine (9)
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More information32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
More informationscalable data centre energy management solution
scalable data centre energy management solution scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology
More informationShort Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationTraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
More information