LAN CONTROLLER instruction from 2.30
|
|
|
- Teresa Davis
- 10 years ago
- Views:
Transcription
1 LAN CONTROLLER instruction from 2.30 RESTARTER, MONITOR, WATCHDOG, CONTROLLER FEATURES: WWW or SNMP v2 management. firmware upgrade via TFTP read data in real time without refresh page read all sensors by xml st0.xml switching output by the command from your browser (IP/outs.cgi?outx=x) possibility switch on/off to 5 relay direct from page WWW events panel to self-programming by user Scheduler (switch on/off output for definite time in week days) Watchdog IP to five IP device monitoring od additional devices eg. sensors measurement: environment temperature, suplly voltage, temperature and curent from conected sensors power measurement for DC voltage posisibility connection of the additional board with RJ45 ports (4 LAN Input, 4 ye LAN + PoE) or additional board with 4 relays Set time manualy or by server NTP Posisibility sensors calibration steering frequency and duty PWM notification about programmed events SNMP TRAP notification about programmed events Automatic send SNMP TRAP with state or value inputs implement protocols: HTTP, SNMP, SMTP, SNTP, ICMP, DNS, DHCP. service temperature sensors: NTC10K B=3380, KTY-84, PT1000, DS18B20 Default user and password is admin, IP adress is side 1 z 15
2 TECHNICAL SPECIFICATIONS supply voltage: 8-56V (from 6V- if don t use mesurement current and PT1000) power consumption : about 1W PoE supply: YES, passive Protection from wrong supply polarization: YES interface: ethernet 10Mbit/s relay: 255VAC 10A work temperature: -20 do +85 st. C weight 45g (without casing) casing type Z-67 (not included) dimensions 57x67mm INPUT/OUTPUT: 1 RELAY to switch on/off/ another devices, available contact: NC and NO 4 OUTPUT to switch relays, ports PoE or another devices; 1 STEERABLE OUTPUT PWM from 2,6 KHz to 4Mhz; 4 LOGICAL INPUT (2 on terminal block- max 12V, 2 on 5 pin connector-max 5V): to monitoring another devices, eg. bufor supply. collaboration with outputs: OC,NO, NC 5 ANALOG INPUT: INP1: temperature measurement witch thermistor NTC 10K B=3380( from -40 to +120 C) or thermistor KTY (from -40 to +300 C), accuracy 1 C (dependent on NTC) INP2: thermistor NTC 10K or voltage mesurement to 3,6V, with use additional divider increase range.. INP3: voltage measurement to 35V, accuracy +- 0,1V; INP4: temperature measurement by PT1000 (from -20 to +850 C) accuracy +- 2 C; INP5: measurment DC current to 3A, accuracy +- 10mA; MAGISTRALA 1-WIRE (connector RJ11) to DS18B20 sensor, max 4 pcs in soft version 3.xx(without Watchdog) max 6 pcs. side 2 z 15
3 PINS and COMPONENTS DESCRIPTION IDC10 GND5 INP4D INP3D Temperature board sensor Power LED 1 Ethernet 10Mbit. INP1D GND1 INP2D GND2 RESET button, change relay state and do sets reset +3,6V INP1 INP2 INP3 GND3 INP6 - RJ11 1-WIRE bus Reley bond (output OUT0) INP4 INP5 GND4 LED 2 PIN/Component Power RELAY bond LED1 LED2 IDC10 INP1D GND1 INP2D GND2 +3,6V INP1 INP2 INP3 GND3 INP4 INP5 GND4 INP6 INP3D INP4D GND5 Description Power suplly 8V-56VDC or via PoE To connect external device, detail description below Shine LED means Power on board Shine LED means relay active To connect additional board, detail description below Logical inpuut 1 gnd for INP1D and INP2D or general gnd Logical inpuut 2 general gnd Supply for sensors NTC-10K and KTY-84 connected to INP1 or INP2 input for sensor NTC-10K or voltage measurement max (without divider ) 3,6V input for sensor NTC-10K Or KTY input for voltgae measuerment max 35V general gnd input for sensor PT1000 or connected the same sensor in solar controller Input for current measurement Gnd for current measurement Or general if don t measurement current Input for DS18B20 sensor ( 1-wire bus on RJ11 connector) Logical inpuut 3 Logical inpuut 4 gnd for INP4D and INP4D or general gnd side 3 z 15
4 Relay Bond: NO contact normaly open CON common contact NZ contact normaly closed NO CON NZ ATTENTION: In spite of that relay can switch AC voltage 255 VAC 10A, board fail to comply with safety requirements (lack housing, earthing). Therefore that receiver connect with the assistance safety external relays eg. on DIN bus, controlled by relay on board. IDC10 and RJ not use 2 not use 3 +3,6V 4 OUT4 5 GND 6 OUT3 7 PWM output 8 OUT2 9 VIN, vcc suplly 10 OUT1 10 RESET BUTTON Push about 0,5 second cause change relay state on opposite, push and keep longer about 5 second (if we not logged by WWW on modul) cause modul reset, next if you still keep button about 10 second cause set all settings to default. Set all settings to default confirmation is fast switch relay on/off (klik-klik), don t wrong this with change relay state about 0,5s and switch relay off after restart. User and password: admin IP: side 4 z 15
5 Sensors connect 1. Current measurement. This reciver current we measured VCC Power suplly GND 2. Temperature measurement and logical input. INP1_D GND INP2_D +3,6V NTC-10K INP1 INP2 NTC-10K lub KTY84 GND PT-1000 INP4 side 5 z 15
6 3. Voltage measurement. INP1 is use to temperature measure or voltage, in control panel you must choice what you want measure GND Measure voltage max 3,6 V DC or more if you add divider resistor INP1 INP3 Measure voltage max 35 V DC GND Additional resistor to increase measure range INP1 Measure voltage R INP1 R = 10K increase range 2 (multiplier 2) that is 3,6V x 2 = 7,2V R= 20 K increase range 3 (multiplier 3) R= 30 K increase range 4 (multiplier 4) etc. Add resistor must be connected with set proper multiplier in field VCC on control panel page. multiplier side 6 z 15
7 Management by WWW. 1.Control Panel Set state All Klik cause output change relay state on opposite simultaneously (OUT0 relay on according to combo box board) Change outputs state display Run PWM generator Value of calibration Any text description, max 8 chars Run Power measure from INP3 (voltage) and INP5 (current) Choce type connected sensor Reset time for 0 normal outputs work (ON/OFF), for time > 0 output after push button change state and return to state before after the specified time in seconds (max 65534). Automatic switching outputs at a specific time (2 windows :1-time switch, 2-break time) side 7 z 15
8 2.Events Config (events panel) Value of hysteresis ON/OFF input When signal cross up this value output will be set ON Or generator PWM start or send e_mail or SNMP Trap Delay of set outputs after occur events, in seconds max When signal cross down this value output will be set ON Or generator PWM start or send e_mail or SNMP Trap Trap Save setings (ON/OFF input you don t must save) If check, means that is ON text taht will be send if events occurance, max amount char is 79. Chars = and & are not allowed For logical input INP1D and INP2D, and SNMP Trap notification are send when input level change from 1 to 0 or 0 to 1, additional to text (at end) will be add value 1 or 0 mark actual input state. side 8 z 15
9 Config events description: Example: 3.Watchdog When check, watchdog will be automaticly disabled and enabled when relay on/off by events set in Events config When events occur, next ping to this same IPX will be send after this time (max 65535second) Time to respond is 4 second, after this time one PING failures Amount PING failures, after this one of three events will be happen: set (ON) output, set (OFF) output reset (ON/OFF) output on definite time (max 65535s). is counting. In time waiting to respond, another IPX aren t send ping, this may causa stretch time statment that another IPX adress is inaccessible. side 9 z 15
10 4.Scheduler Run auto switch out (switch times set in control panel) at specific time provided than INP1D is in a state that we set ( HIGH (1) or LOW(0)) Week Day Mo-Monday, Tu- Tuesday, We- Wednesday, Th- Thursday, Fi- Friday, Sa- Saturday, Su-Sunday, ## - all week day Letter size is important Format: number output(from 0 to 4),day1,day2,day3,day4,day5,day6, xx:xx:xx(time) Example: 0,Mo,12:23:00 sets out0 every Monday at 12:23:00 1,Sa;Fi,Mo,23:22:03 sets out1 every Saturday,Friday and Monday at 23:22:03 1,Sa;Fi,Mo,Tu,Su,Th,23:22:03 sets out1 every Saturday, Friday, Monday, Tuesday, Sunday and Thursday at 23:22:03 0,##,12:01:30 - sets out0 every week day at 12:01:30 Reset time in second (max 65535). side 10 z 15
11 Network Configuration. Working as a server (receiving packets and enable / disable the corresponding output) or client (send packets to the server after changing the state of the INP1D or INP2D). LK working as a server can be driven from any number of clients, provided it is set to the same password. Change INP2D INP1D or switches to a low output state selected "ON", the return to the high state output switches to "OFF". side 11 z 15
12 Time Interwal - minuts. TRAP Enable enabled send TRAP by SNMP. Enable Automatic Send TRAP enable automatic send TRAP by SNMP (above TRAP Enable must be enable) Time Interval (max value 10555) period to send TRAP from given INPUT, accuracy 10 s Relay state after start side 12 z 15
13 Reading XML data Enter the IP address and the page name eg /st0.xml The values of the sensors should be divided by 10 Control Panel: dynamic data st0.xml static data st2.xml Events Config : s.xml Watchdog: w.xml Scheduler: sch.xml Network Config: board.xml Up time: s_time.xml with the Timezone Switching outputs http request You can switch any outputs without clicking on the buttons in the control panel, making use of the following commands: IP/outs.cgi?out=xxxxx Switching outputs to the opposite of the current IP/outs.cgi?outx=x ON or OFF the output when password authentication is enabled, the commands have this form: user:password@ip/outs.cgi?out=xxxxx user:password@ip/outs.cgi?outx=x Example: /outs.cgi?out=0 changes the out0 state to the opposite /outs.cgi?out=2 changes the out2 state to the opposite /outs.cgi?out=02 changes the out0 and out2 state to the opposite /outs.cgi?out=01234 changes the out0,1,2,3,4 state to the opposite /outs.cgi?out0=0 out0 ON /outs.cgi?out0=1 out0 OFF /outs.cgi?out1=0 out1 ON /outs.cgi?out1=1 out1 OFF /outs.cgi?out4=0 out4 ON /outs.cgi?out4=1 out4 OFF side 13 z 15
14 Firmware Upgrade. You my upgrade firmware on two way: 1. By dedicate software LAN Controler Tools (find controler or put IP and click Upgrade Firmware ). 2. By any TFTP client, description below. Send firmware file by TFTP, you have 5 second (Green LED on RJ45 socket blink) to start send firmware when modul run after reset (you my casus reset by click button Save config and Reboot in Network configuration or Reset button on board or dedicate software LAN Controler Tools ). If start transmision not happen that device start work normal. If tftp transmision will start than wait about 90 second to finish upload firmware. After upload device will be reset and start normal. If you want to upload upgrade file chose Save config and Reboot in Network configuration or power OFF and power ON device. The file must be send in binary mode eg. In Windows XP tftp client tftp i put file_upgrade.bin. side 14 z 15
15 OID dla SNMP Soft_version READWRITE ASCII_STRING SYS_OID READONLY OID SYS_UP_TIME LAN_NAME READONLY TIME_TICKS READWRITE ASCII_STRING. TRAP_RECEIVER_ID READWRITE BYTE. TRAP_RECEIVER_ENABLED READWRITE BYTE. TRAP_RECEIVER_IP READWRITE IP_ADDRESS. TRAP_COMMUNITY READWRITE ASCII_STRING. OUT0 (5) READWRITE BYTE. OUT1 (6) READWRITE BYTE. OUT2 (7) READWRITE BYTE. OUT3 (8) READWRITE BYTE. OUT4 (9) READWRITE BYTE. TEMP (10) READONLY ASCII_STRING. VCC (11) READONLY ASCII_STRING. INP1 (12) READONLY ASCII_STRING. INP2 (13) READONLY ASCII_STRING. INP3 (14) READONLY ASCII_STRING. INP4 (15) READONLY ASCII_STRING. INP5 (16) READONLY ASCII_STRING. INP6 (17) READONLY ASCII_STRING. INP7 (18) READONLY ASCII_STRING. INP8 (19) READONLY ASCII_STRING. INP9 (20) READONLY ASCII_STRING. I3XI5 (21) READONLY ASCII_STRING. PXT (22) READONLY ASCII_STRING. INP1D (23) READONLY BYTE. INP2D (24) READONLY BYTE. INP3D (25) READONLY BYTE. INP4D (26) READONLY BYTE. side 15 z 15
LAN Controller V2.0 Firmware version 3.00
LAN Controller V2.0 Firmware version 3.00 Manual LAN Controller LAN controller is a simple, but innovative device which has long been lacking in the market network solutions. A small board serves as a
LAN Controller V2.0 Firmware version 3.10
LAN Controller V2.0 Firmware version 3.10 Manual LAN Controller LAN controller is a simple, but innovative device which has long been lacking in the market network solutions. A small board serves as a
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1
Intelligent power sockets IQsocket tm IQSB-PicoIP makes your life more comfortable User Guide IQSB-PicoIP documentation v1.0 R1 User guide www.iqsocket.eu Important information... 2 1 Introduction... 4
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
GSM V2 MODULE SPECIFICATIONS: Restarter and monitoring for devices GSM V2
GSM V2 MODULE Restarter and monitoring for devices The controler has a relay for switching devices and three inputs monitoring, for example, which you can control the power supply work buffer or other
POE SWITCH 8 PORT 100/10Mbit instruction version 1.0
POE SWITCH 8 PORT 100/10Mbit instruction version 1.0 8 PORT SWITCH, POE, MONITOR, WATCHDOG,EMAIL CAPACITIES: management by WWW or SNMP v2. Firmware upgrade by special application read data in real time
Users manual. TCW181B-CM_R1 Page 1
Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.
Innovative Electronics for a Changing World INDEX
Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.
Ethernet controller TCW122B-CM (Firmware version 2.xx) User manual
Ethernet controller TCW122B-CM (Firmware version 2.xx) User manual 1. Short description TCW122B-CM is an Ethernet controller, based on TCW122 hardware. It has 2 digital and 2 analog inputs, 1-Wire interface
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
3.5 Mobile LAN Disk. User Guide
3.5 Mobile LAN Disk User Guide Contents 1. Hardware...2 1.1 Power...2 1.2 Ports...2 1.3 Reset Button...2 1.4 LEDs...2 1.5 Front View...3 1.6 Rear View...3 2. Installation....... 4 2.1 Requirements 4 2.2
User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B
User s Manual UPS SERIES Network Interface Card UPS-IPCARD I-00453 Rev B TABLE OF CONTENTS INTRODUCTION............................................................. 3-4 INSTALLATION GUIDE.......................................................
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
Olson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install
TPDIN-Monitor-WEB Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase
Expert Power Control NET 4x 8212 / 8213
2010 Gude Analog- und Digitalsysteme GmbH 2010 Gude Analog- und Digitalsysteme GmbH 23.08.2010 Content 3 Table of content Kapitel 1 Security Advise 5 Kapitel 2 Description 5 Kapitel 3 Hardware 6 3.1 Content
NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2
NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
GPS NTP TIME SERVER Rack Version V2
GPS NTP TIME SERVER Rack Version V2 Description: Server is dedicated to synchronize network devices local time/date to Universal Time (UTC) Devices synchronizing own local time through the NTP V3 protocol.
Network Power Manager. User Manual
Network Power Manager User Manual Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 1. Introduction The PDU is an Internet ready device
GPS NTP TIME SERVER Rack Version V2.2x
GPS NTP TIME SERVER Rack Version V2.2x Device Description: GPS NTP Time Server is designed to synchronize local time and date of network devices such as PCs, routers. Devices synchronize their local time
Poseidon2 3268 MANUAL
Poseidon2 3268 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied
4. Rear View. Function Switches 1. Fixed IP 2. DHCP Floating IP 3. Auto IRIS (DC Driver LENS) 4. Fixed LENS (AES)
4. Rear View 5 1.STATIC IP 2.DHCP 3.DC IRIS Mini USB 1 2 3 4 5 6 1. ALM-RST 2. ALM-IN 3. ALM-OUT 4. GND 5. RS485-6. RS485 + 1 2 3 4 5 6 7 DC Power Input: DC Jackψ2.1, DC12V---0.5A or higher. LAN/WAN Network
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
SNMP-1 Configuration Guide
SNMP-1 Configuration Guide You must configure the Net Logic Card before it can operate properly. You have two methods to configure the Net Logic Card: Using telnet or terminal. Using Telnet 1. Make sure
User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured
User s Manual Remote Management Card RMCARD202 Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured Version 1.2 TABLE OF CONTENTS Introduction 1 Installation
ABACOM - netpio. http://www.abacom-online.de/div/setup_netpio.exe
ABACOM - netpio Download http://www.abacom-online.de/div/setup_netpio.exe The ABACOM netpio board is a 10Mbit network interface designed for measurement and control applications. The board is available
Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM
Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation
DVG-2101SP VoIP Telephone Adapter
This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DVG-2101SP VoIP Telephone Adapter Before You Begin 1. If you purchased this VoIP Telephone
Turn on all of your network devices and then check to see if the LEDs on the Access Point display normally as the diagram below describes.
Connect to the Access Point with the Ethernet cable or via wireless. The default SSID of the Access Point is TP-LINK_ XXXXXX. The XXXXXX is the last 6 characters of the Access Point s MAC address. Plug
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
HC Products ILF-100WD User Manual
Internet Line Fault Monitor 2012 HC Security Products Patent Pending 7711 Idlewild RD. Indian Trail, NC 28079 www.hcproductlines.com Tel: 877-908-CCTV (2288) Fax: 888-801-8295 Rev. 2.00 03/22/2012 Table
SNMP-SSL UPS SNMP Card (Web-Based monitoring SNMP Card) User s Manual
UPS SNMP Card (Web-Based monitoring SNMP Card) User s Manual Table of Contents Electronic Emission Notice... 3 Safety Information... 3 Chapter 1 Introduction... 4 Features...4 Package Contents... 5 System
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
Ethernet Port Quick Start Manual
Ethernet Port Quick Start Manual THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE ETHERNET PORT OF EDI SIGNAL MONITORS with Ethernet Version 1.5 firmware. DETAILS OF THE ECCOM OPERATION ARE DESCRIBED
Internet Telephony PBX system IPX-1980
Internet Telephony PBX system IPX-1980 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Hardware Installation... 4 2.1 Safety Instruction... 4 2.2 Front panel... 4 2.3 LED & Button
Power Supply SNMP Interface User Manual for SRL versions
Power Supply SNMP Interface User Manual for SRL versions SNMP-L User Manual 150722(firmware 02r_a12).doc Table of Contents 1. INTRODUCTION... 3 1.1 Default IP Address... 3 2. LOGIN... 4 3. MONITORING &
*Compatible with MPI series grid-tied inverters WWW.MPPSOLAR.COM
USER MANUAL SNMP/Web Card Module *Compatible with MPI series grid-tied inverters WWW.MPPSOLAR.COM OVERVIEW The SNMP/WEB card provides you with a very easy to use network management capabilities by supporting
Network Management Card
Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
Chapter 3 Management. Remote Management
Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
IP POWER 9258 USER MANUAL IP POWER 9258 USER MANUAL
IP POWER 9258 USER MANUAL USER MANUAL IP POWER 9258 Version: X.X 2005.11-1 - VER. X.X, Warning: Any changes to this equipment without permission may cause damages to your equipment! This equipment has
Polycom Phones User Guide. 2003-2012 Bicom Systems
I Table of Contents Part I Introduction 1 Part II Requirements 1 Part III Installation 2 1 Power... Adapter 3 2 Power... over Ethernet (PoE) 3 3 Factory... Settings 3 3 Part IV Registering Phone 1 Manual...
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
User s Manual CONTENT. Nano NAS Server for USB storages. 1. Product Information...1. 2. Product Specifications.2. 3. System requirements..
CONTENT Nano NAS Server for USB storages 1. Product Information...1 2. Product Specifications.2 3. System requirements..3 4. Product Connecting. 4 5. Configuring DN-7023....5 6. Setting... 9 7. Note..
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
N300 WiFi Range Extender
Model EX2700 User Manual July 2014 202-11395-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
PN5212/PN5320/PN7212/PN7320
PN522/PN5/PN722/PN7 Over the NET Distribution Units ALTUSEN Over the NET products are Distribution Units that offer outlet level control combined with remote access to give IT administrators the ability
Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
Wifi Pan/Tilt IP Camera User Manual
Wifi Pan/Tilt IP Camera User Manual Rev. 3.0 Software Version 3.00 May. 25 th.2009 Table of Contents 1. PRODUCT VIEWS...3 1.1. PRONT PANEL...3 1.2. BACK PANEL...3 1.3. ACCESSORIES...4 2. SETUP AND STARTUP...5
The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O
Quick Installation Guide. Live! Titanium
Quick Installation Guide Live! Titanium Contents 1. Live! overview... 2. Installation... 3. Network setup... 4. Wireless setup... 5. Configuring your Live!... 6. Troubleshooting... 2 4 7 8 9 10 1 1. Live!
Application Note FC-Series
Application Note FC-Series Radiometric, Video Analytic and General Purpose Input Output (GPIO) Alarms 427-0073-13-28 Rev. 110 May 2015 Copyright 2015 FLIR Systems, Inc. All rights reserved. FLIR Commercial
P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: http://192.168.1.1. Password: 1234
P-3202H-Bb G-PON VoIP IAD Firmware v1.0 Edition 1, 09/2009 DEFAULT LOGIN DETAILS IP Address: http://192.168.1.1 User Name admin Password: 1234 Copyright 2009 Device Panels POWER PON ETHERNET 1~4 PHONE
How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip
Thomson Telecom S.A.S with a capital of 130 037 460 RCS 390 546 059 Copyright THOMSON 2005 All rights reserved 09/2005-1 www.speedtouchpartner.com ST2030 TM SIP European Community Declaration of Conformity
SX-3000EDM Integration Guide
SX-3000EDM Integration Guide SX-3000EDM Integration Guide PN: 140-20116-110 Rev. A 1 Table of Contents SX-3000EDM Integration Guide Product Overview... 3 Introduction... 3 Features... 4 Block Diagram...
Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7
Contents Introduction--1 Product Description.................................. 1 Internal Management Features........................... 3 Front Panel........................................ 5 Watchdog
Firewall VPN Router. Quick Installation Guide M73-APO09-380
Firewall VPN Router Quick Installation Guide M73-APO09-380 Firewall VPN Router Overview The Firewall VPN Router provides three 10/100Mbit Ethernet network interface ports which are the Internal/LAN, External/WAN,
Appendix for Tx5xx and P85x1 manuals
Appendix for Tx5xx and P85x1 manuals Content Appendix for Tx5xx and P85x1 manuals...1 Content...1 Design of www pages for Tx5xx and P85x1 Ethernet transducers...2 Procedure of creation of www pages for
IP Power Stone 4000 User Manual
IP Power Stone 4000 User Manual Two Outlet Remote AC Power Controller Multi Link, Inc. 122 Dewey Drive Nicholasville, KY 40356 USA Sales and Tech Support 800.535.4651 FAX 859.885.6619 techsupport@multi
Remote Management Card
Remote Management Card RMCARD202 / RMCARD203 RMCARD302 / RMCARD303 User s Manual Version 2.0 The Remote Management Card allows a UPS system and environmental sensor to be managed, monitored, and configured.
User s Manual. Remote Management Card
User s Manual Remote Management Card RMCARD202/RMCARD203 RMCARD302/RMCARD303 Intelligent Remote Management Card allows a UPS system/environment sensor to be managed, monitored, and configured Version 1.6
- 1 - SmartStor Cloud Web Admin Manual
- 1 - SmartStor Cloud Web Admin Manual Administrator Full language manuals are available in product disc or website. The SmartStor Cloud Administrator web site is used to control, setup, monitor, and manage
Link Gate SIP. (Firmware version 1.20)
Link Gate SIP (Firmware version 1.20) User guide v1.0 1 Content 2 1. Technical parameters - Dimensions 133 x 233 x 60 mm - Weight 850 g - Operating position various - Operating condition temperature: +5
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Quick Installation Guide
0, Total 18 Quick Installation Guide Sep, 2013 1, Total 18 Thank you for purchasing Enterprise High Gain Outdoor CPE. This manual will instruct you how to configure and manage this CPE, enable you to use
USER GUIDE. Web Interface
USER GUIDE Web Interface 1. Overview... 4 2. Install and Set Up... 4 2.1. Charge your Wi-Fi HDD... 4 2.2. For Mac users... 5 2.3. Connect your Wi-Fi HDD to your computer (no Internet connection required)...
Temperature Alert. LAN-based Temperature and Humidity Data Logger
Temperature Alert LAN-based Temperature and Humidity Data Logger LAN-based Temperature and Humidity Monitoring - Supports Simultaneous WiFi and Hardwired Interfaces -20 C to +60 C (-4 F to +140 F) Standard
BROADBAND INTERNET ROUTER USER S MANUAL. Version 1.0. - Page 1 of 13 -
Version 1.0 - Page 1 of 13 - 10/100M Broadband Router GETTING TO KNOW 2 3 4 1 5 7 6 - Page 2 of 13 - LED Indicator S/N Indicator Function 1 Power LED (Green) LED lights up steadily indicate that the power
Alarm Messages... 15 Clearing the Hardware Alarms... 16. How to Log On... 17 Summary Page... 21 Navigation Menu... 24
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
Chapter 4 Managing Your Network
Chapter 4 Managing Your Network This chapter describes how to perform network management tasks with your ADSL2+ Modem Wireless Router. Backing Up, Restoring, or Erasing Your Settings The configuration
Powerware Environmental Rack Monitor User s Guide
Powerware Environmental Rack Monitor User s Guide FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Installation and setup guide V 1.0
V o I P G S M G A T E BlueGate SIP 1 Installation and setup guide V 1.0 1. General description 1.1 Technical parametres Dimensions 100 x 130 x 37 mm Weight 850 g Operating position various Operating condition
Chapter 7 Troubleshooting
Chapter 7 Troubleshooting This chapter provides troubleshooting tips and information for your ProSafe VPN Firewall 200. After each problem description, instructions are provided to help you diagnose and
Yealink Phones User Guide. 2003-2012 Bicom Systems
I Table of Contents Part I Introduction 1 Part II Requirements 1 Part III Installation 2 1 Power... Adapter 3 2 Power... over Ethernet (PoE) 3 3 IP Address... 3 4 Factory... Settings 3 4 Part IV Registering
ENHWI-N3. 802.11n Wireless Router
ENHWI-N3 802.11n Wireless Router Product Description Encore s ENHWI-N3 802.11n Wireless Router s 1T1R Wireless single chip can deliver up to 3x faster speed than of 802.11g devices. ENHWI-N3 supports home
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m
Dell Network Management Card User's Guide w w w. d e l l. c o m s u p p o r t. d e l l. c o m Notes and Warnings NOTE: A NOTE indicates important information that helps you make better use of your software.
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
The data between TC Monitor and remote devices is exchanged using HTTP protocol. Monitored devices operate either as server or client mode.
1. Introduction TC Monitor is easy to use Windows application for monitoring and control of some Teracom Ethernet (TCW) and GSM/GPRS (TCG) controllers. The supported devices are TCW122B-CM, TCW181B- CM,
Environmental Management System
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
Configuration Manual English version
Configuration Manual English version Frama F-Link Configuration Manual (EN) All rights reserved. Frama Group. The right to make changes in this Installation Guide is reserved. Frama Ltd also reserves the
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R
OSBRiDGE 5XLi Configuration Manual Firmware 3.10R 1. Initial setup and configuration. OSBRiDGE 5XLi devices are configurable via WWW interface. Each device uses following default settings: IP Address: