BY-LAW AMENDING THE BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS (03-096)
|
|
- Osborne Roberts
- 7 years ago
- Views:
Transcription
1 VILLE DE MONTRÉAL BY-LAW BY-LAW AMENDING THE BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS (03-096) In view of sections 6, 55 and 62 of the Municipal Powers Act (R.S.Q., chapter C-47.1); In view of section 80 of the Charter of Ville de Montréal (R.S.Q., chapter C-11.4); At the city council meeting of April 27, 2009, it was enacted: 1. The title of the By-law concerning the sanitation and maintenance of dwelling units (03-096) is amended by replacing the words and maintenance of dwelling units by the words, maintenance and safety of dwelling units. 2. Article 1 of that by-law is amended by: (1) adding, after the definition of authority having jurisdiction, the following definition: Construction Code : chapter I of the Construction Code (R.S.Q. 1981, chapter B- 1.1, r , as amended by order in council , September 21, 2005 ; (2) adding, after the definition of authority having jurisdiction, the following definition: building height : the height established by the building by-laws in effect on the date of construction of the building, or, by default, the number of storeys between the floor of the first storey and the roof; ; (3) replacing the definition of dwelling unit by the following: dwelling unit : a room or a suite of rooms intended to be used as a domicile, including in particular the rooms offered for rental and artist studios serving as a domicile; ; (4) adding, after the definition of rooming house, the following definition: useful area : the area of habitable spaces measured between the face of walls, excluding the area occupied by a kitchen cupboard; /1
2 3. Article 2 of that by-law is amended by replacing the words Regulation respecting the Construction Code (R.S.Q., chapter B-1.1, r ), and its revisions by the words Construction Code. 4. Article 3 of that by-law is amended by adding, after the word territory, the words except for articles to that apply only to the territory corresponding to that of the city of Montréal on December 31, That by-law is amended by adding the following article after article 5: 5.1. No provisions other than the following apply to an artist studio serving as a domicile: (1) chapter I; (2) chapter II; (3) chapter III; (4) paragraphs (2), (4), (8) and (9) of article 25 of chapter IV.. 6. That by-law is amended by adding the following article after article 6: 6.1. A residential building constructed in accordance with the Québec Building Code 1976 (S-3, r. 2), the National Building Code 1980 (S-3, r. 0.1), the National Building Code 1985 (S-3, r. 0.2), the National Building Code 1990 (S-3, r. 03) or the Québec Construction Code, chapter I Building (R.S.Q. 1981, chapter B-1.1, r , as adopted by order in council or amended by order in council of March 19, 2008, is deemed in accordance with chapter X.1 [ Safety standards of this by-law..] 7. That by-law is amended by adding the following article after article 17: The city may fence off a lot that constitutes a hazard when the owner cannot be found, or when he refuses, neglects or is incapable of carrying the work required to eliminate the hazard after being ordered to do so by employees authorized by the city.. 8. Article 18 of that by-law is amended by adding, after the words under article 17, the words or article That by-law is amended by adding the following article after article 18: When it is established that the conditions of development, occupancy, maintenance or preservation provided for in this by-law may not be reasonably applied, the director may apply different measures /2
3 10. That by-law is amended by adding the following article after article 32: A building containing 11 or more dwelling units must be provided, for the temporary storage of household waste and recoverable resources, with one of the following facilities: (1) a ventilated room in accordance with and accessible to all occupants; (2) one or more closed containers in a storage garage that are : (a) non-combustible, or (b) combustible, provided: (i) they are located no less than 1 m from a combustible material; (ii) they do not exceed 4 and a total volume of 1440 L if their site is not sprinklered. When the storage garage in which the combustible containers referred to in subparagraph (b) of paragraph (2) of the first paragraph are located includes the second exit required for one or more dwelling units, the garage must be fully sprinklered. 11. That by-law is amended by adding the following articles after article 35: A dwelling unit must contain one or more enclosed spaces in which there is a W.C., a bathtub or a shower, and a lavatory A room or a space intended for the preparation of meals must be provided with: (1) a low cupboard with a work surface of at least 0.25 m 2 per habitable room, excluding the surface occupied by a sink, the maximum required for each dwelling unit being 1 m 2 ; (2) cupboards, including the one required under paragraph (1), of at least 0.3 m 3 per habitable room; the maximum required for each dwelling unit being 1.5 m 3. This article does not apply to a room in a rooming house Every room in a rooming house must be provided with a lavatory The title of chapter VII AREAS AND HEIGHTS is replaced by the title AREAS AND CONFIGURATION OF SPACES AND ROOMS /3
4 13. That by-law is amended by adding the following articles after article 43: A dwelling unit containing only one habitable room must have a useful area of at least 17 m A dwelling unit containing 2 separate habitable rooms must have a useful area of at least 20 m 2. An additional area of 3 m 2 is required for each additional separate habitable room That by-law is amended by adding, after article 64, the following chapter, sections, subsections and articles: CHAPTER X.1 SAFETY STANDARDS SECTION I MEANS OF EGRESS SUBSECTION 1 NUMBER OF EXITS Except as provided in article 64.4, a dwelling unit must meet one of the following conditions: (1) have 2 exit doors leading to 2 means of egress that are independent and separate from each other over the entire path of travel; (2) have one exit door opening into an exterior passageway or a public corridor leading to 2 exits that are independent and separate from each other over the entire path of travel A window openable from the inside, with an unobstructed opening at least 0.55 m wide by 1 m high may be considered one of the 2 exit doors required under paragraph (1) of article 64.1, under the following conditions: (1) the apron wall of that window is no more than 0.9 m above the floor level of the first storey or no more than 1.6 m above the floor level of the basement; (2) the difference in height between the floor above which that window is located and the adjacent ground level does not exceed 1.5 m; (3) the window has no grids or, if there is one, it pivots on a vertical axis and is easily opened from the inside without requiring a key or other instrument /4
5 64.3. Except as provided in article 64.4, a dwelling unit occupying several floors must be provided with a sufficient number of exits or exit doors so that it is not necessary to go up or down more than one storey to reach a level served by an exit door or an exit Only one exit is required in one of the following cases: (1) the dwelling unit is provided with an exterior door located no more than 1.5 m from the adjacent ground that may be reached without having to go up or down more than one storey; (2) the dwelling unit is located on the second storey and is provided with an exterior exit door leading to a balcony and an exterior stairway serving only that dwelling unit; (3) the dwelling unit occupies no more than 3 storeys, except the basement, and it is located in a building where there are no tiered dwelling units, and meets the following requirements: (a) the first storey is provided with an exterior door serving only that dwelling unit and is located no more than 1.5 m from the adjacent ground level; (b) the floor of the highest storey is no more than 7 m above the adjacent ground level and that storey is served by a window that can be opened from the inside with an unobstructed opening at least 1 m high by 0.55 m wide, and located so that the sill is no more than 1 m above the floor; (4) the dwelling unit occupies no more than 3 storeys, except for the basement, and meets the following requirements: (a) the first storey is provided with an exterior door located no more than 1.5 m from the adjacent ground level; (b) the highest storey has a direct access to a balcony A floor area must be served by at least 2 exits, except where it is only occupied by dwelling units provided with means of egress in accordance with articles 64.1 to Despite article 64.5, part of the floor area occupied by uses auxiliary to the residential use and located in the basement or on the first storey may be served by a single exit, if it meets the following conditions: (1) the floor area not occupied by dwelling units does not exceed 230 m 2 ; /5
6 (2) the exit leads directly to outside; (3) the distance to reach the exit does not exceed 15 m; (4) that part of the floor area is intended to accommodate, according to the Construction Code criteria, no more than 60 people At least 2 exit doors must be provided for a suite or a room intended for a use auxiliary to the residential use in one of the following cases: (1) the suite or room is intended to accommodate, according to the Construction Code criteria, or accommodates more than 60 people; (2) the suite or room has an area of more than 100 m 2 in the case of a building of combustible construction, and more than 120 m 2 in the case of building of non-combustible construction. SUBSECTION 2 INTEGRITY OF A MEANS OF EGRESS 64.8 An interior exit must be separated from the rest of the building by fire separations with a fire-resistance rating of at least: (1) 45 minutes, in a building of more than 3 storeys in building height; (2) 1 hour, in a building of more than 3 storeys in building height A public corridor must be separated from the rest of the building by fire separations with a fire-resistance rating of at least 45 minutes An existing partition in good condition, continuous and covered on each side with plaster on laths or jointed gypsum boards, is authorized where a fire-resistance rating of 1 hour or less is required under this by-law An exit stairwell serving a building with a building height of no more than 4 storeys is not required to be separated from the public corridor by fire separations in accordance with article 64.8, under the following conditions: (1) each dwelling unit is provided with a second independent means of egress; (2) the stairwell and the public corridor leading to it are separated from the rest of the building as an exit by fire separations in accordance with article 64.8; /6
7 (3) a corridor leading to the stairwell is provided with smoke detectors connected to a fire alarm and detection system, if such a system exists or is required under article 64.45; (4) the length of an unseparated corridor leading to the stairwell does not exceed 6 m The exit door of a dwelling unit may lead directly to an exterior stairway, under the following conditions: (1) the dwelling unit is provide with a second independent means of egress; (2) the building has no more than 4 storeys in building height; (3) the door has fire-resistance rating of at least 20 minutes The door or any fire damper in a fire separation required under this by-law must have a fire-resistance rating of: (1) 20 minutes for a fire separation with a fire-resistance rating of 45 minutes; a door with a solid lumber core of 45 mm meets that requirement; (2) 45 minutes for a fire separation with a fire-resistance rating of 1 hour; an existing kalamein-type door or covered with calibre 24 steel sheet metal on its 6 sides meets that requirement; (3) 1 hour for a fire separation with a fire-resistance rating of 1 hour and 30 minutes; (4) 1 hour and 30 minutes for a fire separation with a fire-resistance rating of 2 hours When it is necessary to replace a door in an opening where a fire-resistance rating of 20 minutes is required, the frame need not be replaced if it is in good condition, if it allows adequate fit of the door, and if the space between the edge of the frame and the door is filled in with glass wool Every door in a required fire separation must meet the following conditions: (1) be provided with a self-closing device certified by an agency accredited by the Canadian Standards Council; (2) be provided with a self-latching device keeping the door in a closed position after use; (3) be adjusted to control the spread of smoke in case of fire /7
8 The flame-spread rating of the covering of walls and ceilings may not be more than 25, but: (1) the covering of the walls and ceiling of an exit may have a flame-spread rating that does not exceed 150, provided the surface of each covering does not exceed 10% of the surface of walls or of the ceiling, as the case may be; (2) the covering of walls in a lobby used as an exit may have a flame-spread rating of no more than 150, provided the surface of the covering does not exceed 25% of the surface of those walls; Compliance with article and as to the fire-resistance rating, and with paragraph (1) of article is not obligatory for existing doors of dwelling units of a building containing 8 or less dwelling units. This article does not apply to rooming houses. SUBSECTION 3 CONFIGURATION OF A MEANS OF EGRESS It must be possible to follow the path of travel of a means of egress at all times without requiring keys or other instruments In a building constructed after December 1, 1976, the width of a means of egress must be at least 0.86 m, except if the means of egress serves no more than 2 dwelling units per storey, in which case its clear width must be at least 0.76 m. In all other cases, the width of a means of egress must be at least 0.76 m In a building constructed after December 1, 1976, the height of a means of egress must be at least 2.05 m. In all other cases, the height of a means of egress must be at least 1.9 m No door in a means of egress may reduce the clear width specified in article by more than 50 mm when it is in an open position, or reduce the clear height specified in article by more than 50 mm Despite articles and 64.20, in a building of no more than 4 storeys in building height and constructed before June 21, 1978, an interior stairway serving as a secondary means of egress for no more than 2 dwelling units per storey, which is passable and at least 550 mm wide, is authorized under the following conditions: (1) the installation, in a stairwell, of smoke detectors connected to a fire alarm and detection system, if such a system exists or is required under article 64.45; /8
9 (2) the posting, inside every dwelling unit, on or near the door leading to the stairway, of instructions to occupants urging them to familiarize themselves with the path of travel of the exit, and to keep it free of clutter Despite articles and 64.20, a stairway located in a shed and used as a means of egress for no more than 2 dwelling units per storey, which is passable and at least 550 m wide, is authorized The exits must lead directly to the exterior. However, an exit may lead to a lobby, provided the travel distance on the first storey does not exceed 15 m. The lobby must be separated from the rest of the building by fire separations in accordance with article An exit must provide access to a public thoroughfare or to an exterior open space leading to a public thoroughfare. In a building containing no more than 8 dwelling units or rooms in a rooming house, one of the exits may lead to an open space at least 6 m deep and, if that space is enclosed by a wall or a fence, they may not be more than 1.2 m high over a continuous length of at least 3 m An exit door located in an exit serving more than 8 dwelling units or rooms in a rooming house must open outwards The exit door of a dwelling unit may not be located in a dead-end corridor, so that it is more than 6 m from an exit or from another corridor leading to 2 opposite exits, unless the dwelling unit is served by a second means of egress independent from the first Despite article 64.27, in a building of non-combustible construction, a dead-end corridor serving as the sole access to the 2 required exits may be more than 6 m long without exceeding 15 m, under the following conditions: (1) despite article 64.45, the building must be equipped with a fire alarm and detection system; (2) the installation, in public corridors, of smoke detectors connected to the fire alarm and detection system; (3) the door of a dwelling unit leading to a dead-end corridor must be designed so that it does not lock automatically /9
10 Despite article 64.27, in a building of non-combustible construction, a dead-end corridor serving as the sole access to the 2 required exits may be more than 15 m long under the requirements of paragraphs (1), (2) and (3) of article and under one of the following conditions: (1) the building is sprinklered; in each dwelling unit, only one sprinkler is required, and it must be installed near the door leading to the public corridor; (2) every dwelling unit that leads to the dead-end part of the corridor, communicates directly with an exterior balcony Despite article 64.27, in a building of non-combustible construction, a dead-end corridor serving as the sole access to the 2 required exits may be more than 6 m long, without exceeding 15 m, if the requirements of paragraphs (1), (2) and (3) of article are met, and if the building is sprinklered. In each dwelling unit, only one sprinkler is required and it must be installed near the door leading to the public corridor Despite article 64.27, in a building of non-combustible construction, a dead-end corridor serving as the sole access to the 2 required exits may be more than 15 m long if the requirements of paragraphs (1), (2) and (3) of article are met, and if the building is sprinklered A fire escape must be: (1) at least 550 mm wide; (2) made of metal, except in the case of a building of non-combustible construction, where it may be of wood; (3) firmly fixed to the building and provide proper resistance to the load it bears; (4) inclined at a maximum angle of 45 with the horizontal; (5) provide with a guard at least 900 mm high, made up of at least 2 smooth plates no more than 0.45 m apart, and with a handrail along the wall if it is more than 550 mm wide; (6) provided with landings of at least 1 m 2 at exits and with intermediate landings, as the case may be, at least 750 mm long; (7) extended to ground level and, if the flight of stairs leading to ground level is mobile, it must be easily lowered with a counterbalancing device /10
11 Access to a fire escape may be by a window openable from the inside, having an unobstructed opening at least 1 m high by 0.55 m wide, with a ledge no more than 0.9 m above the inside floor, except where that access serves a public corridor, in which case it must be a door on a vertical axis. SUBSECTION 4 LIGHTING AND SIGNS OF MEANS OF EGRESS Exist and public corridor must be illuminated to an average intensity of at least 50 lx. In a building containing more than 8 dwelling units or rooms in a rooming house, the exits and public corridors must be provide with emergency lighting of an average intensity of at least 10 lx, capable of operating in case of a power failure for at least 30 minutes Exit signs must meet the following conditions: (1) in a building of 3 storeys or more in building height, an exit door other than the door of a dwelling unit or the main entrance door of the building must bear a light fixture marked SORTIE or EXIT displayed in letters at least 102 mm high, in red on a contrasting background or contrasted on a red background; (2) in part of a corridor leading to an exit where the exit door light fixtures are not visible and at any place where there is a change in direction in the access to an exit or in an exit, there must be a light fixture in accordance with paragraph (1) bearing an arrow pointing to the direction of egress; (3) a light fixture must be provide with an emergency power supply ensuring its operation for at least 30 minutes in case of a power failure. SECTION II FIRE PROTECTION SUBSECTION I FIRE SEPRATION BETWEEN PARTS OF A BUILDING The fuel-burning heating system serving 5 or more dwelling units must be located in a service room separated from the rest of the building by fire separations with a fire-resistance rating of at least 1 hour In a building of 2 or more storeys in building height and of more than 8 dwelling units or rooms in a rooming house, a refuse chute must: (1) be fitted with outlets designed to close automatically and latch after use, and located in separate spaces not used for other purposes, and with a fireresistance rating of at least 45 minutes; /11
12 (2) discharge into a room separated from the rest of the building by a fire separation with a fire-resistance rating of at least 2 hours; (3) be provided with an automatic sprinkler system at the top, at every 5 storeys and into the rooms where it discharges; (4) discharge into a ventilated room provided with equipment for cleaning purposes A storage garage other than a garage serving a single dwelling unit must be separated from the rest of the building by a fire separation with a fire-resistance rating of at least: (1) 1 hour and 30 minutes in a garage that accommodate more than 5 vehicles and located in a building of more than 2 storeys in building height and of more than 8 dwelling units or rooms in a rooming house; (2) 1 hour in other cases In a building of more than 3 storeys in building height, an access between a storage garage and an elevator lobby, an exit stairwell or an exit corridor must be by way of a vestibule at least 1.8 m long, ventilated and provided with automatic closing doors A waste storage room and a public storage room must be separated from the rest of the building by fire separations with a fire-resistance rating of at least 45 minutes in a building of no more than 3 storeys in building height, and at least 1 hour in other cases Subject to more restrictive requirements in this subsection, a dwelling unit must be separated from the public sections of a building by a fire separation with a fireresistance rating of at least 45 minutes. SUBSECTION 2 PROTECTION OF FOAM PLASTICS Except in a crawl space, foam plastic applied to the exposed surface of a wall or a ceiling must be protected in accordance with the Construction Code /12
13 SUBSECTION 3 SMOKE ALARMS Smoke alarms conforming to CAN/ULC-S531-M87 Standard for Smoke Alarms must be maintained in each dwelling unit and each room of a rooming house. Smoke alarms must meet the following requirements: (1) within a dwelling unit, a smoke alarm must be installed between each sleeping area and the rest of the dwelling unit or in a corridor if the sleeping areas are not served by a corridor; (2) a smoke alarm must be installed on the ceiling or on the wall provided the top of the alarm is not less than 10 cm or more than 30 cm from the ceiling; (3) smoke alarms must be installed with a permanent connection to an electrical circuit, with no disconnect switch, except for the overcurrent device, or they must be battery-powered; (4) when several smoke alarms must be installed in a dwelling unit, they must be wired so that the activation of one alarm causes all alarms to sound simultaneously, except if they are battery-powered alarms. Smoke alarms in a rooming house or in building erected after August 27, 1985, must be permanently connected to an electrical circuit with no disconnect switch, except the overcurrent device Every lessee or occupant of dwelling unit must ensure that the battery or the overcurrent device that feeds a smoke alarm in a dwelling unit is in place and in good working condition. SUBSECTION 4 FIRE DETECTION AND ALARM SYSTEMS Except as provided in article 64.46, a building of more than 3 storeys, including the basement floors or of more than 10 dwelling units or rooms in a rooming house must be provided with a fire detection and alarm system in accordance with the Construction Code. However, when a residential use constitutes the main use of the building, such a system is not required in the following cases: (1) no more than 4 dwelling units are served by a public means of egress; (2) a building of no more than 3 storeys in building height where each dwelling unit is served by an exterior exit leading to ground level; (3) a building of 3 storeys in building height and containing no more than 10 dwelling units or rooms in a rooming house /13
14 When required under article 64.45, an existing fire detection and alarm system must include: /14 (1) smoke detectors at the top of each exit stairwell; (2) fire detectors at the following places: (a) in every dwelling unit; (b) in every public corridor; (c) in every waste storage area that is not part of a dwelling unit; (d) in every service room that is not part of a dwelling unit; (e) in every elevator shaft; (f) in every storage garage; (g) in every suite or room that is not part of a dwelling unit; (3) on every storey, at least a horn at least 150 mm in diameter or equivalent, connected to the detectors required under paragraphs (1) and (2) and manual pull stations required under paragraph (4); (4) on every storey, manual pull stations near every required exit; (5) a panel consisting of one or more circuits under electronic surveillance, an emergency electrical power source, and a visual and audible trouble indicator Every existing fire detection and alarm system must be put to the test to ensure compliance with CAN/ULC-S536-M When a building partly occupied by a residential use contains another main use for which a fire detection and alarm system is required under another by-law, the residential part of the building must be served by the same system. SUBSECTION 5 PORTABLE EXTINGUISHERS AND STANDPIPE AND HOSE SYSTEMS The public areas of a building containing more than 4 dwelling units or rooms in a rooming house must be provided with category 2-A:10-B.C. portable fire extinguishers, on each storey near exits, in sufficient number so that the travel distance to reach one from the exit door of a dwelling unit, of a room or of any other room, does not exceed 23 m.
15 A building of more than 4 storeys in building height must be provided with a standpipe and hose system consisting of: (1) on every storey, at least one hose station, with a flexible pipe 38 mm in diameter and no more than 30 m long, capable of spraying every part of the storey by projecting water at 9 m; (2) on every storey above the fourth storey, at least one hose connection 64 mm in diameter capable of spraying all parts of the storey with a flexible pipe no more than 30 m long, projecting water at 9 m; (3) a two-way connection outside the building in a visible and easily accessible location; (4) a residual water pressure of at least 207 kpa with a flow rate of 6.3 L/s at the topmost outlet. SUBSECTION 6 HEATING EQUIPMENT Solid-fuel-burning equipment or oil burning equipment must be in accordance with the following standards or previous editions of standards applicable at the time of installation of the appliance or equipment: (1) CAN/CSA-B365-M91 Installation Code for Solid-Fuel-Burning Appliances and Equipment; (2) CAN/CSA-B139-M91 Installation Code for Oil Burning Equipment No combustion stove may be installed or used in a room of a rooming house A service room where a fuel-burning appliance has been installed must be provided with a fresh air inlet well suited to the operation of the appliance. SECTION III GUARDS AND HANDRAILS Balconies, galleries, roof decks, overhead walkways and mezzanines must de provided with guards at least 900 mm high on all open sides where the difference in level exceeds 600 mm An exterior stairway with more than 6 risers must be provided with a guard at least 900 mm high on all open sides where the difference in level between the stairway and adjacent ground level exceeds 600 mm /15
16 An interior stairway with more than 3 risers must be provided with a guard at least 900 mm high on all open sides In the case of an interior stairway serving more than one dwelling unit and in the case of a balcony, a gallery, a roof deck and an overhead walkway, the size of any opening through guards must be designed to prevent any spherical object 100 mm in diameter from going through A balcony or a gallery serving a single dwelling unit and where the difference in level between the floor and ground level does not exceed 900 mm is not subject to article An interior stairway must be provided with one handrail when its width is 1100 or less, and with 2 handrails when its width is more than 1100 mm. A handrail must be continuous, except when it is interrupted by doors or posts An interior stairway with more than 3 risers must be provided with a handrail. 15. That by-law is amended by adding the following chapter and article after article 66: CHAPTER XI.1 INTERPRETATIVE PREVISION This by-law may in no way be interpreted as to restrict or limit the scope of a more specific or a more stringent requirement in an another by-law The Housing By-law (R.B.C.M, chapter L-1) is repealed. The public notice relating to this by-law was posted at city hall and published in The Gazette on May 6, /16
BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS
CITY OF MONTRÉAL BY-LAW 03-096 BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS As the municipal administration seeks to ensure that all Montrealers benefit from acceptable housing conditions;
More informationNumber of Sides Required to Have a Handrail
Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance
More informationMINIMUM STANDARDS FOR HIGH-RISE BUILDINGS
CHAPTER 93 MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS Note: Chapter 93 is entirely Seattle amendments to the International Fire Code and is not underlined. Point of Information The requirements of this
More informationCh. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE Sec. 58.1. Division D-O occupancies. 58.2. Separation and mixed occupancy. OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM
More informationBUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS
DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE
More informationExcerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
More informationCITY OF TORONTO. BY-LAW No. 349-2008
Authority: Licensing and Standards Committee Item 12.3, adopted as amended, by City of Toronto Council on April 28 and 29, 2008 Enacted by Council: April 29, 2008 CITY OF TORONTO BY-LAW No. 349-2008 To
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationBuilding Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International
More informationNew Ontario Building Code Highlights
New Ontario Building Code Highlights Part 9 This summary highlights items that are believed to be significant changes to the 2012 OBC and is not intended to include all changes made within this or other
More information9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
More informationOverview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
More information- 5 - Table1. Maximum Compartment Volumes
- 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,
More informationNew Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
More informationMINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us
More informationName Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
More informationMinimum Housing and Health Standards
APPENDIX M.O. 57/2012 Minimum Housing and Health Standards Original version July 20, 1999. Revisions to Part lll, Housing Premises, sections 3 and 4, June 30, 2012 (all revisions are bolded and underlined).
More informationBUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
More informationFIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
CHAPTER 46 FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS SECTION 4601 GENERAL 4601.1 Scope. The provisions of this chapter shall apply to existing buildings constructed prior to a state building
More informationMINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us
More informationBasement Development Construction requirements for the development of basements in residential dwellings.
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Basement Development Construction requirements for the development of basements in residential dwellings. June 2009 contents GENERAL INFORMATION 3 BUILDING
More informationDesign Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have
More informationFlorida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationGuidance on loft conversions in two-storey houses
Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for
More informationBuilding Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
More informationhttp://www.iccsafe.org/
Sections R311 and R312 from the 2006 International Residential Code These sections of Chapter 3 of the 2006 International Residential Code for One and Two Family Dwellings (R311 and R312) including the
More information2007 ICC FINAL ACTION AGENDA
907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal
More informationBuilding Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
More informationErrata has been identified as follows:
2009 IFC Performing Commercial Fire Inspections Inventory Number: 1424S09 Second Printing; July 2014 Changes HAVE been made- Third Printing: September 2014 Errata has been identified as follows: 1. Page
More informationKITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
More informationCHAPTER 9 FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. Provisions of this chapter shall govern the application, design, installation, testing and maintenance of automatic sprinklers, standpipes
More informationSPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS
Document F SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS This document is intended as a specific guide for persons who own, manage or control Houses
More informationPage 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.
Page 1 of 17 Page 2 of 17 Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology. CODE PARAGRAPH WITH SUGGESTED CHANGES: 6.4.6.1.2 Residents should be rated as response probable
More informationDecree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
More informationNew York City Department of Buildings
The New NYC Building Code Chapter 10 Means of Egress New York City Department of Buildings Technical Affairs Fatma M. Amer, P.E. Copyright Materials This presentation is protected by US and International
More informationProperty Maintenance Check List
Property Maintenance Check List Scope These minimum conditions and responsibilities of persons for maintenance of structures, equipment and exterior property shall govern. Responsibility. Owners shall
More informationWe hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.
September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify
More informationCHILD CARE CENTER INFORMATION SHEET
CHILD CARE CENTER INFORMATION SHEET SECTION 1 INTRODUCTION This fire safety information sheet is based on the 2007 Minnesota State Fire Code (MSFC) and the 2007 Minnesota State Building Code (MSBC). It
More informationArizona Health Care Association DISASTER PLANNING AND EMERGENCY MANAGEMENT GUIDE POST INCIDENT DAMAGE ASSESSMENT CHECKLIST
It is essential to perform a Basic Damage Assessment (BDA) following an adverse event to help ensure the safety of building occupants as well as prevent additional losses from occurring. This checklist
More informationSt. John s University
St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica
More informationGeneral Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
More information5-8.1.4* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.
NFPA 101 Life Safety Code Section 5-8 Illumination of Means of Egress 5-8.1 General. 5-8.1* Illumination of means of egress shall be provided in accordance with this section for every building and structure
More informationCity of Bettendorf Fire Alarm System Requirements
City of Bettendorf Fire Alarm System Requirements Section 907 of the 2009 Edition of the International Fire Code (IFC) and Section 10-7-3 of the Municipal Code provide fire alarm requirements. IFC Section
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationTYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
More informationArea of Rescue Assistance Communication System ADA Code Applicable excerpts:
Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment
More informationFIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No
General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency
More informationREVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationHealthcare Engineering. Code Summary Report
American Society for Healthcare Engineering Code Summary Report CODE SUMMARY HEALTH CARE NEW BUILDINGS This code summary is based on the following codes: 2000 Edition NFPA 101, The Life Safety Code (LSC),
More informationBOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
More informationFire Safety In High Rise Building
Fire Safety In High Rise Building CLASSIFICATION OF BUILDINGS AS PER NATIONAL BUILDING CODE 1. GROUPING. Group A - Residential : Lodgings, Dwellings, Dormitories, Flats, Hotels. Group B Group C - Educational
More informationEAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST
DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1
More informationFIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures
More informationMAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
More informationTelluride Fire Protection District Fire Alarm Systems Policy Version 03/2007
Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 FIRE ALARM SYSTEMS POLICY TELLURIDE FIRE PROTECTION DISTRICT TABLE OF CONTENTS FIRE ALARM PROTECTION POLICY PLAN REVIEW SUBMITTAL
More informationOntario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
More informationMUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number 07-2012
MUNICIPALITY OF KAZABAZUA SMOKE DETECTORS By-Law number 07-2012 Notice of motion : August 7, 2012 Publication : September 9, 2012 Adoption : November 15, 2012 Effective November 15, 2012 Resolution: 2012-09-234
More informationCONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
More informationFIRE-FIGHTING DESIGN BRIEF REPORT
P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM
More informationIssue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste
150 Code for Sustainable Homes Category 5: te Issue ID Description No. of Credits Available Mandatory Elements 1 Storage of Non-recyclable te and Recyclable Household te 4 Yes Aim To provide adequate internal
More informationHow To Write A Fire Risk Assessment
Fire Safety Risk Assessment This form is to aid you in carrying out a fire safety risk assessment of a property. The form is separated in to two parts: Part 1 initial assessment form and guidance notes
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 STAIRWAYS 46. LANDINGS. Section R311 IRC 2009 R311.7.5 Landings for stairways. There shall be a floor or
More informationHow To Build A Basement House
Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International
More informationVestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004]
Vestibule Case Study [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Requirement Intent Page 1 of 14 The primary intent behind the requirement for a vestibule is to reduce infiltration
More informationFLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:
More informationSPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)
SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon) SECTION SR101 GENERAL SR101.1 General. Group SR occupancies shall comply with the provisions of this appendix
More informationSchedule B to By-law 33-2009
Amended by By-law 8-2016 Note: This consolidation is prepared for convenience only. For accurate reference the original by-laws should be reviewed. Floor Area Calculation Floor area shall: Schedule B to
More informationEducational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application
February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management
More informationFirefighter Review. Instructor Guide
Firefighter Review Instructor Guide Session Reference: 3 Topic: Attack Line Handling Level of Instruction: Time Required: Three Hours Materials: Two Fully Equipped Pumpers Structure for Use in Advancing
More informationOntario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)
Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Notice: This e-learning module is intended for general information purposes only. It only highlights certain provisions of the
More informationCITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
More informationGeneral Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
More informationMobile Fire Rescue Department Bureau of Fire Prevention
222 Mobile Fire Rescue Department Bureau of Fire Prevention Samuel L. Jones Mayor Stephen A. Dean Fire Chief February 2011 2009 International Fire Code Fire Alarm and Detection Systems 907.1 General. This
More informationFire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
More informationNorthern Ireland Housing Executive: HMO Fire Safety Guide
Northern Ireland Housing Executive: HMO Fire Safety Guide Contents Equality Statement 5 Houses in Multiple Occupation (HMOs) means of escape in case of fire and other fire precautions 6 1.0 Introduction
More informationDepartment of Licenses and Inspections PARTNERS FOR GOOD HOUSING
City of Philadelphia Department of Licenses and Inspections PARTNERS FOR GOOD HOUSING Revised - April 2004 Produced by the Commissioner s Office PARTNERS FOR GOOD HOUSING The City of Philadelphia, on behalf
More informationIndiana Building Rehabilitation Standard
Rule 8. Indiana Building Rehabilitation Standard 675 IAC 12-8-1 Definitions Sec. 1. The following definitions apply throughout this rule: (1) "Building code" means the Indiana Building Code under 675 IAC
More informationWalking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
More informationNC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02
NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02 PART A: Project Data and Classification 1. Project name & location Renovation of the Cheerwine Building, 322 East Council St.,
More informationBuilding Department John Fiedler Construction Official Ext. 211. SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev 4-3-2014
TOWNSHIP OF HILLSBOROUGH COUNTY OF SOMERSET Hillsborough Township Municipal Complex The Peter J. Biondi Building 379 South Branch Road Hillsborough, NJ 08844 P: (908) 369-4313 F: (908) 369-3954 Building
More informationCOMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
More informationBY-LAW NO. 181-04 OF THE CORPORATION OF THE CITY OF CAMBRIDGE
BY-LAW NO. 181-04 OF THE CORPORATION OF THE CITY OF CAMBRIDGE Being a by-law of the Corporation of the City of Cambridge for prescribing standards for the maintenance and occupancy of property within the
More informationDecree of the Ministry of the Environment. on fire safety of garages
E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision
More informationRHODE ISLAND DIVISION OF STATE FIRE MARSHAL
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL Smoke Alarm and Carbon Monoxide Brochure JOHN E. CHARTIER STATE FIRE MARSHAL 118 PARADE STREET PROVIDENCE, RI 02909 DAYS 401-462-4200 24 Hr. 401-222-2331 FAX#
More information2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes. Questions. 1004.1 Design Occupant Load. 1005 - Means of Egress Capacity Determination
2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes Clay Aler, P.E. Principal caler@koffel.com Andrew M. Schneider, P.E. Senior Fire Protection Engineer aschneider@koffel.com Questions Submit
More informationHow To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
More informationWINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
More informationSARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions
More informationProposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata - 700090 Developer Premier Mica Mining And Manufacturing Company
RISK MANAGEMENT PLAN is an integral part of a modernized and sophisticated residential complex. No efforts will be spared in identifying the all possible risks and disasters, evaluating them, installing
More informationOPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: GUARDING FLOORS, STAIRS, AND OTHER OPENINGS Guidelines: This checklist covers some of the
More informationINSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
More informationUnderwriting Guidelines for Condominium Pac and Condominium Pac Plus
UNDERWRITING GUIDELINES FOR CONDOMINIUMS SEGMENT Local exceptions to these underwriting guidelines may apply. Please consult with your underwriter or sales executive for details and to discuss risks which
More informationALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
More informationSpray Booth Guideline
Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that
More informationPlanning Information. Passenger and Freight Elevators.
A company of ThyssenKrupp Elevator Thyssen Aufzüge tk This planning information will give you an overview of the most important planning criteria of passenger and freight elevators. However you should
More informationc. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.
Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent
More informationSCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST
SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST School Name: School Address: Town: Phone: Inspected By (Please Print): Inspection Organization Name: Inspector Phone: Date of Inspection: Building Name:
More information