MTU Onsite Energy unveils new Series 1600 diesel generator sets
|
|
|
- Juliana Bell
- 9 years ago
- Views:
Transcription
1 October 7, 2009 Press Information Contact: Jennifer Riley Telephone: Agency contact: Robert E. Sheldon, APR Creative Communications Consultants, Inc. Phone: Editor note: To download this news release, go to: MTU Onsite Energy unveils new Series 1600 diesel generator sets New MTU Series 1600 generator sets extend range of MTU diesel-powered generator sets from 250 kw to 3,250 kw. Mankato, Minnesota MTU Onsite Energy, a leader in distributed power solutions, introduces its newest MTU diesel-powered generator set covering a range of 250 kw to 600 kw. The new genset is based on the MTU Series 1600 engine, through which MTU s proprietary power range is extended from as low as 250 kw up to 3,250 kw. The Series 1600 engine is a completely new engine for MTU and is the smallest engine that the company produces. It has all the hallmarks of an MTU engine: exceptional reliability, high power density and fuel efficiency. When combined with MTU Communications, Outer Drive West, Detroit, Michigan USA
2 2/5 the completely new design of the generator set package, the result is a compact powerhouse that is ideal for emergency standby and peak-shaving applications. The engine s load acceptance is exceptional, says Neil Majeski, program manager for the Series 1600 genset. It is an incredibly stable engine that is very well built. The Series 1600 engines, from 12V to 6-cylinder inline, will offer an advantage in covering power nodes that were previously sourced from two different engine manufacturers. The Series 1600 diesel generator set comes standard with many features that previously required custom ordering. Standard features include: EPA Tier 2 certification Compliance to ISO testing for transient response at 85% load (as opposed to standard testing at 70% load) NFPA 110 one-step rated load acceptance (1 step 100% block load) Digital control panels that are UL recognized In addition, the outlet box on the Series 1600 genset has been designed to incorporate not only the outlet box, but also the breaker and control panels in one streamlined package. Its design allows for the flexibility to switch the control panels and breakers to the right or left depending on the need, and allows the mainline circuit breaker to be installed in a compartment on the right or left side per customer specification. The outlet box can accommodate multiple mainline circuit breakers,
3 3/5 utilizing both compartments. This is a standard design feature that previously would have required custom engineering. We are very excited about the outlet box housing everything, says Majeski. The design not only offers greater flexibility, but it also gives the genset a well-packaged look with very clean lines. The Series 1600 generator sets also have an improved electrical stub-up compared to similar gensets powered by other engine types. The new design allows ample room for connecting cables in the stub-up area, thus making installation easier. Another design advantage is in the mounting of the outlet box. Whereas previous generator set designs mounted the outlet box to the barrel of the alternator, the Series 1600 outlet box is mounted directly to the base of the genset. This significantly reduces the amount of vibration to which the outlet box is subjected, which has a positive effect on the life of the electrical system. Generator sets based on the 12V configuration of the Series 1600 are currently available in 550 kw kw power nodes. MTU Onsite Energy has already received several orders for the Series 1600 generator sets, the first of which are scheduled for delivery in December.
4 4/5 EDITOR S NOTE: To download this news release and high-resolution photo, go to: (MTU-8141) To introduce the new MTU Series 1600 gensets, this 600 kw unit was used to power a social event for nearly 300 MTU Onsite Energy customers and distributors at the company's headquarters in Mankato, Minnesota. - End - MTU Onsite Energy Corporation MTU Onsite Energy Corp. (formerly Katolight Corporation) is a leading producer of diesel-powered generator sets from 30 to 3,250 kw and natural gas-powered generator sets from 20 to 400 kw for standby, prime power and cogeneration applications. The company also provides automatic transfer switches, paralleling switchgear, controls and accessories for complete power system solutions. Based in Mankato, Minnesota, MTU Onsite Energy Corp. combines the expertise of Katolight and MTU Detroit Diesel Power Generation under one brand to meet the ever increasing distributed power needs of customers in North America and around the world. MTU Onsite Energy Corp. is part of the Tognum Group s business unit, Onsite Energy and Components. For more information, visit Tognum With its two business units, Engines and Onsite Energy & Components, the Tognum Group is one of the world s leading suppliers of engines, propulsion systems and distributed energy systems. These products are based on diesel engines with up to 9,100 kilowatts (kw) power output, gas engines up to 2,150 kw, fuel cells up to 360 kw and gas turbines up to 50,000 kw.
5 5/5 The product portfolio of the Engines business unit comprises MTU engines and propulsion systems for ships, for heavy land, rail and defense vehicles, and for the oil and gas industry. The portfolio of the Onsite Energy & Components business unit includes distributed energy systems of the brand MTU Onsite Energy, fuelinjection systems from L Orange, and drive shafts from Rotorion. The energy systems comprise diesel engines for emergency power generation, basic and peak load, and cogeneration power plants based on gas engines, fuel cells and gas turbines that generate both electricity and heat. In 2008, Tognum generated revenue of more than 3.1 billion and employs more than 8,900 people. Tognum has a global distribution and service structure with 26 fully consolidated subsidiaries, more than 140 sales partners and over 500 authorized dealerships at approximately 1,200 locations. The shares of Tognum AG (ISIN: DE000A0N4P43) have been stock-exchange listed since 2007 and are included in the MDAX.
Energy-efficient data center achieves 2N reliability; MTU Onsite Energy generator sets provide critical backup
Press Release Contact: Gary Mason Tognum America Inc. Phone: +1 248 560 8480 E-mail: [email protected] Agency contact: Robert E. Sheldon, APR Creative Communications Consultants, Inc. Phone: +1 210
LEED-certified COPT DC-6 Data Center s green design includes innovative backup power solutions from MTU Onsite Energy
Press Release Contact: Gary Mason Tognum America Inc. Phone: +1 248 560 8480 E-mail: [email protected] Agency contact: Robert E. Sheldon, APR Creative Communications Consultants, Inc. Phone: +1 210
POWER GENERATION. www.mtu-online.com
POWER GENERATION A TOGNUM GROUP BRAND Valid for north america Europe / Middle East / Africa / Latin America MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax + 49 7541
Bergen Engines Products and Applications
Bergen Engines Products and Applications 1 Since 1948 Bergen Engines, a Rolls-Royce Power Systems Company, has delivered more than 6,500 four-stroke medium-speed diesel and gas engines for power generation
Anwendung von Polyspace im Software Entwicklungsprozess nach IEC 60880. München, 19.05.2011, Dr.-Ing. Jörg Barrho
Anwendung von Polyspace im Software Entwicklungsprozess nach IEC 60880 München, 19.05.2011, Dr.-Ing. Jörg Barrho Agenda 01 Tognum and MTU Friedrichshafen 02 Background and project 03 Overview IEC 60880
Understanding Tier 4 Interim and Tier 4 Final EPA regulations for generator set applications
Understanding Tier 4 Interim and Tier 4 Final EPA regulations for generator set applications While Tier 4 standards that begin to take effect in 2011 do not apply to generator sets used strictly for emergency
MTU ONSITE ENERGY. Madrid, November 19 th, 2014. MTU Onsite Energy GmbH All rights reserved
MTU ONSITE ENERGY Madrid, November 19 th, 2014 MTU Onsite Energy GmbH All rights reserved MTU ONSITE ENERGY Rolls Royce Introduction 01. Our Vision 02. Our Roots 03. Rolls-Royce Power Systems AG 04. The
Integrated Power Systems for Data Centers
Integrated Power Systems for Data Centers A Commitment to Data Centers Caterpillar is committed to providing optimum value to the Data Center industry by leveraging our engineering, manufacturing, distribution,
A reliable and experienced supplier
Email : [email protected] A reliable and experienced supplier A joint venture to increase efficiency Two CATERPILLAR dealers for more than 75 years decided to associate their experiences and skills
Development of Power Supply System with Hybrid Turbocharger for Marine Application
JFE TECHNICAL REPORT No. 19 (Mar. 2014) Development of Power Supply System with Hybrid Turbocharger for Marine Application SUTO Naonori*1 MINAMI Hiroki*2 Abstract: Hybrid turbocharger is a turbocharger
Brochure. Electric generators to power the world
Brochure Electric generators to power the world We provide motors and generators, services and expertise to save energy and improve customers processes over the total life cycle of our products, and beyond.
Power backup in data centers. Something going on. 24 I MTU Report 03/10
Power backup in data centers Something going on 24 I MTU Report 03/10 Energy All over the world, Internet commerce is growing at an incredibly rapid rate as more and more people become accustomed to banking,
FPT FIAT POWERTRAIN TECHNOLOGIES PRESENTS ITS ENGINE RANGE FOR CONSTRUCTION APPLICATIONS AT INTERMAT 2009
FPT FIAT POWERTRAIN TECHNOLOGIES PRESENTS ITS ENGINE RANGE FOR CONSTRUCTION APPLICATIONS AT INTERMAT 2009 FPT Fiat Powertrain Technologies, is the Fiat Group Company dedicated to the research, development,
NO-BREAK KS 7e. Concentrated Energy. 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM
NO-BREAK KS 7e Concentrated Energy e 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM Data Centre owners, operators and designers are required to meet ever increasing and
Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines
36 Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines KEIICHI SHIRAISHI *1 YOSHIHISA ONO *2 YUKIO YAMASHITA *3 MUSASHI SAKAMOTO *3 The extremely slow steaming of ships has become
Redesign of 400-600kW Diesel Products Reflects Voice-of-The-Customer Improvements
When Your Credibility Depends On It - Connect With Us Volume III, Issue 1V December 2012 In This Issue: Redesign of 400-600kW Diesel Products Page 1 University of Utah Install is MPS Showpiece Page 2 New
STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities
Generator Testing in Nursing Facilities Introduction Recent emergencies and natural disasters have emphasized the need to ensure that nursing facilities have an adequate EPSS in place should the loss of
STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts
DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,
Minimizing Impact of Electric Utility Outages with Backup Generation
Minimizing Impact of Electric Utility Outages with Backup Generation Introduction of the Speaker Michael Dempsey, PE Senior Electrical Engineer Carter & Burgess, Inc. Energy & Power Solutions Facility
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES by Kazuhiro Takeda Research Manager, Research and Development Center and Kengo Hirano Instrument and Control Engineer,
TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength
SPP Pumps Inc. Atlanta
SPP Pumps Inc. Atlanta UL Listed, FM Approved Fire Pump Sets Horizontal Split Case Pumps Flows from 200-5000 US GPM Vertical Turbine Flows to 5000 US GPM In-Line Pumps Flows to 750 US GPM End Suction Flows
TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,
J. Freihaut, Ph.D. Architectural Engineering, Professor Penn State Univesity
Philadelphia NAVY YARD Energy Innovation Campus J. Freihaut, Ph.D. Architectural Engineering, Professor Penn State Univesity Navy Yard Grid Background Navy Yard Grid Background One of the largest non-municipal
Paralleling Switchgear
Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more
Frequently Asked Questions Generators
Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books
VM 32. Efficiency and Performance New Product Development Modular Design 12 16 Cylinder
VM 32 E with Efficiency and Performance New Product Development Modular Design 12 16 Cylinder VM 32 E Power Output 6,720 8,960 kw The new VM 32 E engine is designed for our offshore customers seeking the
ABB Inc. April 19, 2011 Slide 1
ABB Automation & Power World: April 18-21, 2011 Allen Austin - Solar Segment Manager North America, Low Voltage Products WLP-123-1-CEU Solar applications for low voltage products ABB Inc. April 19, 2011
THM Gas Turbines Heavy duty gas turbines for industrial applications
THM Gas Turbines THM Gas Turbines Heavy duty gas turbines for industrial applications Combined advantages The THM 1304 heavy duty gas turbine family consists of two members with ISO power outputs of 10,500
SSE s criteria used for GHG emissions reporting
SSE s criteria used for reporting 1 Introduction This document details the annual greenhouse gas emissions reporting approach used by SSE Plc to report the tonnes of carbon dioxide equivalent (CO2e) during
DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET
DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA
Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime
Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure for Business-Critical Continuity Are you deploying a remote site faster than you can
MICRO HYDRO POWER GENERATING EQUIPMENT
MICRO HYDRO POWER GENERATING EQUIPMENT TOSHIBA TOSHIBA ENGINEERING In general, specifications of hydroelectric power system vary depending upon the installation location. The hydro turbine and generator
Dual Fuel Medium Speed Product. Presenter Name Date
Dual Fuel Medium Speed Product Presenter Name Date Contents Caterpillar, Inc. Overview Our Product Line Dual Fuel Product Dual Fuel Conversion Performance & Maintenance References Caterpillar, Inc. Making
INSPECTION AND TESTING OF EMERGENCY GENERATORS
INSPECTION AND TESTING OF EMERGENCY GENERATORS Certification requirements NFPA 101(00), Sec. 7.9.2.3 requires that emergency generators be installed, tested and maintained in accordance with NFPA 110,
Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy
Data Center Combined Heat and Power Benefits and Implementation Justin Grau, Google Inc. Sam Brewer, GEM Energy Data Center Challenges Electric Load Densification Thermal Dissipation Requires constant
4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm
The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance
Power to the adaptable data center
Business Unit Manager, Data Center Solutions, Eaton s electrical group IT managers have more options than ever to tailor the power infrastructure to their unique data center and business requirements.
HyPM Fuel Cell Power Modules
HyPM Fuel Cell Power Modules HyPM XR Fuel Cell Power Module for stationary and backup power applications HyPM HD Fuel Cell Power Module for mobility applications Purpose-built to deliver the best in performance
C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm
CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression
CAT CG132. Series Gas Generator Sets
CAT CG132 Series Gas Generator Sets CAT CG132 SMARTER ENERGY SOLUTIONS COMMERCIAL AND INDUSTRIAL FACILITIES Facilities such as manufacturing plants, resorts, shopping centers, office or residential buildings,
Paralleling Power Sources Which Share a Common Neutral
Paralleling Power Sources Which Share a Common Neutral By: Tony Hoevenaars, P.E., President & CEO, Mirus International, Inc. Mike McGraw, President, NSOEM, Inc. When paralleling power sources that share
Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:
Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs Layout of the plant Index:
Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice
Bulk Storage the OIL SAFE Way OIL SAFE Bulk Systems are the most feature rich and highest quality lubricant storage and dispensing systems available. Fully Modular and ships ASSEMBLED Three System Types
DIESEL GENERATOR SETS
DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete
Powering Productivity. EveryTMEngine. QSX11.9 And QSX15 (290-600 hp) Tier 4 Interim/Stage IIIB
Powering Productivity. EveryTMEngine. QSX11.9 And QSX15 (290-600 hp) Tier 4 Interim/Stage IIIB Powering Productivity. Every Engine. Better Performance. Every Time. At Cummins, we re driving higher productivity
Clear Advantage. EveryTMEngine. QSB6.7 And QSL9 (190-400 hp) Tier 4 Interim/Stage IIIB
Clear Advantage. EveryTMEngine. QSB6.7 And QSL9 (190-400 hp) Tier 4 Interim/Stage IIIB Clear Advantage. Every Engine. Your Best Solution. Every Time. With the arrival of more stringent emissions regulations,
Power Island. Industrial Power Plants. www.siemens.com / energy
Power Island Industrial Power Plants www.siemens.com / energy Flexible combined-cycle power plants With today s increasing demands for flexible power plants, intensified by the increased amount of electricity
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
Auxiliary Power Unit (APU) for Military Vehicles
Auxiliary Power Unit (APU) for Military Vehicles Jeff Humble General Dynamics Land Systems 640 Seminole Rd. Muskegon, Michigan 49441 (231)780-5609 [email protected] Page 1 APU Program Summary Developed
DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility
DC Traction Power Supply Powerful, efficient and safe siemens.com/mobility 2 DC traction power supply More people, more challenges, one solution: Complete mobility. Needed more than ever before: Not only
Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S.
Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S. Armstrong, PE DISTRIBUTED CO-GENERATION DEFINED Electricity and Heat production
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Fluid Automation Solutions
Fluid Automation Solutions www.asconumatics.com Our markets Wherever goods and materials are manufactured, processed, or packaged, ASCO Numatics solutions are found. We serve a wide range of industrial
Floating. Diesel power stations
Floating Diesel power stations MAN Diesel & Turbo The responsible way in leading technology MAN Diesel & Turbo is the world s leading designer and manufacturer of low and medium speed engines. Our involvement
Generators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
MTU and Deutsche Bahn test hybrid train
Drive solutions for local rail passenger transport MTU and Deutsche Bahn test hybrid train Who: What: Why: DB RegioNetz Verkehrs GmbH Westfrankenbahn Hybrid Powerpack To promote energy-efficient and ecologically
Distributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption
IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,
ACTURA 4855. -48 V DC, 3-40 kw, 60-800 A. The Regional DC power system with Global Muscle
ACTURA 4855-48 V DC, 3-40 kw, 60-800 A The Regional DC power system with Global Muscle Reliability or Price Efficiency? Now you can have both! Customized power systems with high reliability at a competitive
Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply. www.siemens.com/siestorage
Totally Integrated Power SIESTORAGE The modular energy storage system for a reliable power supply www.siemens.com/siestorage Totally Integrated Power (TIP) We bring power to the point. Our products, systems,
Diesel and gas engine systems for EURO VI on-highway applications
Diesel and gas engine systems for EURO VI on-highway applications Mercedes-Benz engines in the OM 93X and OM 47X model series. Outstanding design and efficiency. Specifically developed to comply with the
Training Systems for Renewable Energies. Acquiring Practical Skills and Project-oriented Expertise
Training Systems for Renewable Energies Acquiring Practical Skills and Project-oriented Expertise Qualifications through Quality Inexhaustible, sustainable, real the future is green The move away from
Reduce the cost of communication with ComAp. Telecom tower solutions
Reduce the cost of communication with ComAp Telecom tower solutions Telecom tower solutions The world is going through a digital transformation. As subscriber penetration and data traffic continue to rise,
-Liquid-cooled frequency converter switchgear
-Liquid-cooled frequency converter switchgear VEO knows your needs We deliver automation and electrification solutions for energy production, distribution and consumption in close collaboration with our
Using the Phoenix MultiPlus
Using the Phoenix MultiPlus to reduce operating cost of a generator www.victronenergy.com 1. The traditional AC generator system Per Watt ac-power, an inverter is generally more expensive than a generator.
Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)
Ralf Christian, CEO Low and Medium Voltage Making Things Right with Totally Integrated Power (TIP) siemens.com/hannovermesse Making Things Right with Totally Integrated Power (TIP) Trade LV 100 kw Industrial
1. Do you have onsite emergency power generation in any of your facilities? R=992
Load Bank Testing Load Bank Testing Whether required by code or as simply part of good building operations strategy, facility executives whose organizations own emergency generators must test them regularly
A Discussion of PEM Fuel Cell Systems and Distributed Generation
A Discussion of PEM Fuel Cell Systems and Distributed Generation Jeffrey D. Glandt, M. Eng. Principal Engineer, Solutions Engineering May 2011 The information contained in this document is derived from
CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC 28262. DRAFT V0.
Innovation Park Charlotte. NC 28262 DRAFT V0.1 Page 2 CyberFortress Data Center at Innovation Park BECO South purchased Innovation Park in March 2010 and immediately launched a dramatic top-to-bottom $30M
Power Generation generator sets - 400 kva to 15 MW
Generator s Power Generation Power Generation generator sets - 400 kva to 15 MW MGS B/C/HV diesel range MUG diesel range KU diesel range GSR gas range KU gas range Stand-by, prime power & continuous power
How To Drive A Marladebronn Hybrid Bus
New Mercedes-Benz hybrid bus in operation 250 customers test the Mercedes-Benz Citaro G BlueTec Hybrid city bus World's largest lithium-ion battery in vehicle operation Diesel consumption and CO2 emissions
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
A study into the fuel savings potential by a major rebuild of propulsion system
A study into the fuel savings potential by a major rebuild of propulsion system Per Rønnedal Senior Manager New Design Research & Development Marine Low Speed < 1 > Agenda 1 Introduction of MAN and our
Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems
Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in
Bharat Petroleum: Fueling Real Estate Revenues with SAP Real Estate Management
Bharat Petroleum: Fueling Real Estate Revenues with SAP Real Estate Management How does one of India s most recognized energy companies gain more clarity and control over a vast and geographically spread-out
Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks
Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks White Paper Anil K. Trehan, Vice President, Energy Solutions CommScope, Inc. May 28, 2013 Contents
How To Control A Power Command Powerplant
Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power
Galaxy VM. Three-phase power protection. schneider-electric.com
Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
Gas turbine power plants
Gas turbine power plants A global challenge Apart from other sources of energy such as water, coal and uranium, the use of natural gas and fuel oil is an important factor in assuring a reliable supply
Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions?
Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions? The first team in power management ......... The world s best cabinet power
Technical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
TRITON V. Cylinder Pressure Monitoring CPM 500. Replaces mechanical indicators on diesel engines. Improves combustion
TRITON V Cylinder Pressure Monitoring CPM 500 Replaces mechanical indicators on diesel engines Improves combustion Reduces fuel consumption and emissions Optimises engine settings Engine & Turbine Management
Fast Charging Facts Enhancing use of electric lift trucks, AGVs, and other motive electric vehicles
Fast Charging Facts Enhancing use of electric lift trucks, AGVs, and other motive electric vehicles Nasser Kutkut, Ph.D. PowerDesigners USA, LLC Madison, WI Introduction Fast charging of industrial batteries
PROCUREMENT GUIDE: SELECTING A CONTRACTOR/PROJECT DEVELOPER
PROCUREMENT GUIDE: SELECTING A CONTRACTOR/PROJECT DEVELOPER 1. Overview CHP project development and implementation are similar to many central plant construction projects or comprehensive energy conservation
www.nissens.com NISSENS WATER-COOLED CHARGE AIR COOLER
www.nissens.com NISSENS WATER-COOLED CHARGE AIR COOLER NISSENS WCAC WCAC is short for Water-cooled Charge Air Cooler. A water-cooled charge air cooler is a charge air cooler, where the charge air is cooled
Engine catalogue. Marine Diesel engines. MAN range - light duty
Engine catalogue Marine Diesel engines MAN range - light duty ENG 10 November 2010 Marine Diesel engines Engine Power Num. of Displacement Design kw cylinders cm3 R6-730 537 6 12,8 inline R6-800 588 6