MPSV 15 INSTALLATION MANUAL / NÁVOD NA INŠTALÁCIU
|
|
|
- Ashlie Gaines
- 9 years ago
- Views:
Transcription
1 N211/R01 ( ) - SK INSTALLATION MANUAL / NÁVOD NA INŠTALÁCIU MPSV 15 CABLE HEATING CIRCUITS / VODIČOVÉ VYKUROVACIE OKRUHY GENERAL TERMS AND CONDITIONS / VŠEOBECNÉ PODMIENKY The heating part of the cable heating circuit may not be shortened or otherwise adjusted in any way. Only the cold connection ends may be shortened, as needed. The connector joining the cold connection end and the heating circuit must not be installed in a bend. The heating cables may neither touch nor cross one another. The minimum distance between the cables is 30 mm, and the diameter of a bend must be at least eight times greater than the cable s diameter. If the heating or power supply cables are damaged, they must be replaced or repaired by the manufacturer, its service technician or a similarly qualified person in order to prevent a dangerous situation from arising. The heating cable must be supplied with electricity by means of a residual current circuit breaker with rated actuating current of IΔn 30 ma. We recommend that each heating unit/circuit be equipped with a separate residual current device. The heating cables may be stored at temperatures up to the resistance of the jacket (80 C) and installed at a temperature of greater than - 5 C. When in use, the cables may not be exposed to temperatures exceeding 80 C. The installation must allow disconnecting the cables at both poles. Before and after laying the cables, it is necessary to measure the insulation resistance between the heating conductor and the protective braiding. This measured value may not be less than 0.5 MΩ. Record the measured values in the certificate of warranty. In case of any discrepancies, you should report these immediately to the manufacturer or supplier and discontinue the work completely. Before using the heating cable, it is necessary to check whether the data on the label is in accordance with your requested product The supplier must inform other construction suppliers of the place where the heating unit is installed and of the related risks. The perimeter of the area must be separated from the vertical structures by an expansion joint (polystyrene, Mirelon, etc., up to 10 mm wide). Vykurovacia časť vodičového vykurovacieho okruhu sa nesmie krátiť, ani inak upravovať. Krátené podľa potreby môžu byť len studené pripojovacie konce. Spojka spojujúca studený koniec a vykurovací okruh sa nesmie inštalovať v ohybe. Vykurovacie vodiče sa nesmú dotýkať, ani krížiť, vzdialenosť vykurovacích vodičov od seba je min. 30 mm, priemer ohybu vodiča môže byť minimálne osemnásobok jeho priemeru. Ak je vykurovací vodič alebo napájací prívod poškodený, musí byť nahradený alebo opravený výrobcom, jeho servisným technikom alebo podobne kvalifikovanou osobou, aby sa zabránilo vzniku nebezpečnej situácie. Vodiče neinštalujte pomocou hrebíkov a vrutov! Vykurovací vodič musí byť napájaný cez prúdový chránič s menovitým vybavovacím prúdom IΔn 30 ma. Doporučujeme každý vykurovací celok/okruh vykurovania vybaviť samostatným prúdovým chráničom. Vykurovacie vodiče sa môžu skladovať do teplotnej odolnosti plášťa (80 C) a inštalovať pri teplote vyššej než 5 C, pri prevádzke nesmú byť vystavené teplotám vyšším než 80 C. Inštalácia musí umožniť odpojenie vodičov v oboch póloch. Pred pokládkou aj po pokládke je nutné premerať odpor vykurovacieho okruhu. Namerané hodnoty sa musia zhodovať. Namerané hodnoty zapíšte do Záručného listu. Tolerancia nameraných hodnôt ±5-10%. Pred pokládkou a po pokládke musí byť premeraný izolačný odpor medzi vykurovacím vodičom a ochranným opletením nameraná hodnota nesmie byť nižšia než 0,5 MΩ. Namerané hodnoty zapíšte do Záručného listu. Akékoľvek nezhody ihneď oznámte výrobcovi alebo dodávateľovi a ukončite všetky práce. Pred použitím vykurovacieho vodiča je nutné skontrolovať štítkové údaje, či sa zhodujú s požadovaným výrobkom. Dodávateľ musí informovať ostatných dodávateľov stavby o umiestnení vykurovacej jednotky a o rizikách z toho vyplývajúcich. Plocha musí byť po celom obvode oddelená od zvislých konštrukcií dilatačnou škárou (polystyrén, mirelon apod., hr. do 10 mm).
2 In case that cables are laid in an area larger than 20 m 2 or with a diagonal greater than 7 m, it is necessary to account for expansion of the foundation materials (expansion unit max. 25 m 2 for mats up to 80 W/m 2 ). The heating cable may not cross the expansion joints. The non- heating connecting cables located at the expansion joints must be laid loosely in a protective tube. All installed elements cold connection end, thermo regulator s probe where they pass from the wall to the floor must be placed in installation tubes and must allow for movement of the floor and wall relative to one another. An insufficient thermal insulation layer below the heating system may cause significant thermal loss (warmth moving downwards). Recommended thermal insulation is mm of extruded polystyrene or similar thermal insulation materials. The cable may be placed neither under furnishings, nor under furniture that does not allow air to circulate. The distance between the heating part of the cable and the wall should not be less than 50 mm. When putting the cable into operation, each layer must be fully set see the instruction for use and recommendation from the manufacturer of the materials. Materials used in finishing the floor surface (glue for tiles, carpet, parquets, etc.) must be approved by their respective manufacturers for use on floors under thermal stress. Any manner of use different from those specified in this user guide should be consulted with the manufacturer. Pri kladení na plochu väčšiu než 20 m 2 alebo s uhlopriečkou väčšou než 7 m je nevyhnutné rešpektovať dilatáciu podkladových materiálov (dilatačný celok max. 25 m 2 pri vodičoch do 80W/m 2 ). Vykurovací vodič nesmie prechádzať cez dilatačné škáry. Pripojovacie nevykurovacie vodiče musia byť v mieste dilatačných škár volne uložené v ochrannej rúrke. Prechod všetkých inštalácií studený koniec, sonda termostatu zo steny do podlahy musia byť urobené v inštalačných rúrkach a umožňovať vzájomný pohyb podlahy a steny. Nepoužitím dostatočnej vrstvy tepelnej izolácie pod vykurovacím systémom sa vystavujete riziku značných tepelných strát smerom dole. Doporučená tepelná izolácia je mm extrudovaného polystyrénu a obdobne tepelne izolujúcich materiálov. Vodič nesmie byť kladený pod zariaďovacie predmety, ako aj pod nábytok neumožňujúci voľné prúdenie vzduchu. Vzdialenosť vykurovacej časti vodiča od steny nemá byť menšia ako 50mm. Pri uvádzaní vodiča do chodu musia byť jednotlivé vrstvy vyzreté viď. návod a doporučenie výrobcu hmoty. Materiály používané na zušľachtenie povrchu podlahy (lepidlo na dlažbu, koberec, parkety apod.) musí mať doporučenie od výrobcu, že sú určené pre tepelne namáhané podlahy. Iné použitie než je v tomto návode konzultujte s výrobcom.
3 1. Description and connection The heating cables should be connected to a 230V, 50Hz electric network. Degree of protection: IP67. The protective braiding is to be connected to the PE protective conductor. CONSTRUCTION: Core: stranded resistance wire Insuletion: cross- linked polyethylene (XLPE) - 1mm thickeness Protective braiding: 14 tinned copper wires Ø 0,3mm + AIPET foil Jacket: PVC 105 C thickness 0,8mm 1. Popis a zapojenie Vykurovacie vodiče sa pripojujú na sústavu 230V, 50Hz. Krytie IP67. Ochranné opletenie sa pripojuje na PE vodič. KONŠTRUKCIA: Jadro: zlanený odporový drôt Izolácia: sieťovaný polyetylén (XLPE) - hrúbka 1mm Ochranné opletenie: 14 Cu drôtikov Ø 0,3mm pocínovaných + AlPET fólia Plášť: PVC 105 C (UV odolné) hrúbka 0,8mm 2. Use for floor heating in residential buildings, houses, workshops, and restrooms a) Dimensioning If the floor heating is intended to be used to warm the floor surface for short intervals, we recommend that the heating cable be installed close to the floor surface within the upper limit of the recommended outputs W/m 2. If the floor heating is to be used to heat a room, it is necessary to know the thermal loss value for the building to select the most suitable heating system. The installed output should correspond to a multiple of 1.1 to 1.3 times the calculated thermal loss due to the maximum recommended outputs (see table below). An additional heating device must be used (for example, convector ECOFLEX or ATLANTIC). 2. Použitie pre mierne akumulačné a poloakumulačné podlahové vykurovanie a) Dimenzovanie Ak ide o vykurovanie miestnosti, tak pre správnu voľbu vykurovacieho systému musíme poznať hodnotu tepelných strát objektu. Inštalovaný príkon by mal zodpovedať 1,1 až 1,3 násobku vypočítaných tepelných strát z dôvodu max. doporučených výkonov (viď. TAB), musí sa použiť prídavné vykurovanie (napr. konvektor ECOFLEX alebo ATLANTIC). Doporučený plošný príkon pre poloakumulačné vykurovanie je v rozmedzí W/m 2. RECOMMENDED AND MAXIMUM OUTPUTS / TABUĽA DOPORUČENÝCH A MAXIMÁLNYCH PRÍKONOV FLOOR COVERING, ROOM / PODLHOVÁ KRYTINA, MIESTNOSŤ RECOMMENDED FLAT OUTPUT / MAXIMUM FLAT OUTPUT / MAX. DOPORUČENÝ PRÍKON PLOŠNÝ PRÍKON NOTE / POZNÁMKA W/m 2 W/m 2 LAMINÁTOVÁ PODLAHA FLOOR TILES / DLAŽBA FLOOR TILES / DLAŽBA Tepmeratur of floor surface in rooms occupied for long time perions may not exceed 27 C / Teplota povrchu podlahy v dlhodobo obývaných miestnostiach nesmie presiahnuť 27 C
4 b) Installation system with moderate accumulation of heat INSTALLATION INTO CONCRETE (self- levelling screed) Firstly, read General conditions. In the case of fixing of the heating cable directly to thermal insulation (only extruded polystyrene), higher input than 160W/m2 must not be installed. Concrete mixture has to be compacted to such extent that no air bubbles, caverns etc. are present in the layer and so that it ensures perfect contact with the heating cable. The compacting has to be performed carefully and manually, so that the cable is not damaged. In no case it is possible to use immersion vibrators. The concrete mixture must contain so- called plastifiers. In the course of concreting, it is necessary to pay attention to the fact that a break longer than 60 minutes results in an imperfect uniting of areas being concreted. So, in the case of longer pause, it is necessary to create an adhesive connecting bridge, for example by means of penetration or in another way. Be careful when installing the reinforcing grid not to damage the cable insulation. PROCEDURE Lay the thermal insulation to damp- proof base. Unroll the heating cable to the shape of meander, according to required output. Attach the heating cable directly to the thermal insulation, so that it cannot move in the course of concreting, for example with using of Grufast tape or plastic cable clips. Measure the resistance of heating circuit and leakage - differential current, record the measured values in the Certificate of Warranty. Pour concrete to the cable up to required thickness. After the completion of concreting work, perform the measurements again and record measured values in the Certificate of Warranty. The mat may be put into operation only after 28 days, after full maturity of the concrete. b) Montáž mierne akumulačný systém INŠTALÁCIA DO BETÓNU (samonivelačné hmoty) Najprv si prečítajte Všeobecné podmienky. V prípade fixácie vykurovacieho vodiča priamo na tepelnú izoláciu (len extrudovaný polystyrén) nesmie byť inštalovaný príkon väčší než 160W/m2. Betónová zmes musí byť natoľko zhutnená, aby vrstva neobsahovala vzduchové bubliny, kaverny apod. a zaisťovala dokonalý kontakt s vykurovacím vodičom. Hutniť je nutné opatrne, ručne, aby nedošlo k poškodeniu vodiča. V žiadnom prípade nepoužívať ponorné vibrátory. Betónová zmes musí obsahovať tzv. plastifikátory. Pri betónovaní je nutné dbať na skutočnosť, že pri prestávke dlhšej než 60 minút sa betónované plochy dokonale nespoja. Preto pri dlhšej prestávke je nutné vytvoriť adhezívny spojovací mostík, napr. penetráciou alebo iným spôsobom. Pri inštalácii armovacieho železa je nutné dať pozor, aby nedošlo k poškodeniu izolácie vodiča. POSTUP Na hydroizolovaný podklad položte tepelnú izoláciu. Rozviňte vykurovací vodič v tvare meandra, podľa požadovaného výkonu. Vykurovací vodič fixujte priamo na tepelnú izoláciu tak, aby sa pri betonáži nemohol pohnúť, napr. páskou Grufast alebo Plastovou príchytkou vodiča. Premerajte odpor vykurovacieho okruhu a unikajúci rozdielový prúd, zapíšte do Záručného listu. Vodič zalejte vrstvou betónu do požadovanej výšky, po skončení betonárskych prác opäť premerajte a zapíšte do Záručného listu. Rohož uveďte do prevádzky najskôr po 28 dňoch, po úplnom vyzretí betónu. System with moderate accumulation of heat / Mierne akumulačný systém 1) Base / Podklad 2) Thermal insulation 80mm / Tepelná izolácia 80mm 3) Ecofloor heating cable / Vykurovací vodič Ecofloor 4) Reinforcing steel grid / Armovacia oceľová sieť 5) Concrete accumulation layer 40 50mm / Betónová akumulačná vrstva 40 50mm 6) Wiring tube with floor probe / Inštalačná rúrka s podlahovou sondou 7) Finish floor / Nášľapná vrstva
5 PROCEDURE: Cover the hydro- insulated foundation with a thermalinsulation layer, then cover this layer with a 4 cm layer of concrete. Allow the concrete to set fully. Clean the concrete area, remove any sharp objects and coat it using a suitable penetrating solution. Place the heating cable in an open- looping pattern in accordance with the required output. Fix the heating cable (e.g., using Grufast fastening strips) so that it cannot move during further concreting. In humid spaces, connect the protective braiding of the cable to the protective grounding connection for the room. Measure the resistance of the heating circuit and the insulation resistance and record the measured values in the certificate of warranty. Cover the cable with a concrete layer up to the required height. After concreting is finished, measure the resistance values again and record them in the certificate of warranty. Wait at least 28 days after installation before putting the mat into operation, so that the concrete will be set fully. Materials used in finishing the floor surface (glue for tiles, carpet, parquets, etc.) must be approved by their respective manufacturers for use on floors under thermal stress. POSTUP poloakumulačný systém Na hydroizolovaný podklad položte tepelnú izoláciu, na izolácii vytvorte 4cm vrstvu betónu. Betón nechajte vyzrieť. Betónovú vrstvu očistite a zbavte ostrých predmetov a natrite penetračným náterom. Rozviňte vykurovací vodič v tvare meandra, podľa požadovaného výkonu. Vykurovací vodič fixujte tak, aby sa pri ďalšej betonáži nemohol pohnúť, napr. páskou Grufast. Vo vlhkých priestoroch spojte ochranné opletenie vodiča s ochranným pospojovaním miestnosti. Premerajte odpor vykurovacieho okruhu a izolačný odpor a zapíšte do Záručného listu. Vodič zalejte vrstvou betónu do požadovanej výšky, po skončení betonárskych prác opäť premerajte a zapíšte do Záručného listu. Rohož uveďte do chodu najskôr po 28 dňoch, po úplnom vyzretí betónu. Materiály používané na zušľachtenie povrchu podlahy (lepidlo na dlažbu, koberec, parkety apod.) musí mať doporučenie od výrobcu, že sú určené pre tepelne namáhané podlahy. Semi- accumulating system / Poloakumulačný systém 1) Base / Podklad 2) Thermal insuletion, 80mm / Tepelná izolácia 80mm 3) Reinforcing steel grid / Armovacia oceľová sieť 4) Ecofloor heating cable / Vykurovací vodič Ecofloor 5) Accumulating concrete layer, mm / Betónová akumulačná vrstva mm 6) Installation pipe with a floor probe / Inštalačná rúrka s podlahovou sondou 7) Floor finish / Nášľapná vrstva c) Regulation For regulation, use one of FENIX s available thermostats. For floors where exceeding the hygienic limit of 27 C is not anticipated, or for floors in rooms occupied for only short intervals (bathroom, lavatory, corridor) with surface area output of up to 160 W/m 2, it is optional to use the thermostat s limiting floor probe. For all other applications, the thermostat must be equipped with a floor probe with the maximum temperature set to 35 C. For semi- accumulating floor heating, a thermostat with a floor probe is required c) Regulácia Na reguláciu použite termostat z aktuálnej ponuky firmy FENIX. Pri podlahách, kde sa nepredpokladá prekročenie hygienickej hranice 27 C alebo ide o krátkodobo obývané miestnosti (kúpelňa, WC, chodba) s plošným príkonom do 160 W/m 2 nie je podmienkou limitujúca podlahová sonda termostatu. Pri všetkých ostatných aplikáciách musí byť termostat vybavený podlahovou sondou s max. nastavením 35 C. Pri poloakumulačnom podlahovom vykurovaní je nevyhnutný regulátor s podlahovou sondou.
6 d) Accelerating the warming of heating floors FOR HEATING MAT LAID IN A CONCRETE LAYER Wait at least 4 6 weeks after installation before putting the mat into operation, so that the concrete will be set fully. On the first day, set the temperature of the floor to be the same as the temperature in the room (maximum 18 C). In the following days, increase the temperature in increments of 2 C per day up to 28 C. Maintain the temperature of 28 C for three days. Then, decrease the temperature of the floor by 5 C per day until you reach the initial temperature. Afterwards, you can set the desired temperature and put the floor into normal operation. d) Nábehy vykurovacích podláh ULOŽENIE VO VRSTVE BETÓNU Vykurovacia podlaha sa uvádza do prevádzky až po riadnom vytvrdnutí betónu po 4 6 týždňoch. Prvý deň nastaviť teplotu podlahy zhodnú s teplotou v miestnosti (maximálne 18 C). Nasledujúce dni zvyšovať teplotu podlahy postupne o 2 C/deň až na 28 C. Teplotu podlahy udržovať na teplote 28 C po dobu troch dní. Následne znižovať teplotu podlahy o 5 C denne pokým nedosiahne počiatočnú teplotu. Potom je možné teplotu podlahy nastaviť na požadovanú a uviesť podlahu do bežnej prevádzky. 3. Moderate heating of piping to provide antifrost protection The heating cables placed on metal or plastic pipes prevent liquid in the pipes from freezing when outside temperatures are below 0 C. The heating cables may also be used to heat or maintain a certain temperature in the pipes up to 60 C. 3. Použitie na protimrazovú ochranu a na vyhrievanie potrubí Vykurovacie vodiče umiestnené na kovové alebo plastové potrubie poskytujú ochranu pred zamŕzaním kvapalín v potrubí pri okolitých teplotách nižších ako 0 C. Vykurovacie vodiče je možné taktiež použiť na vyhrievanie alebo udržovanie teploty v potrubí až do teploty 60 C. a) Dimensioning / Dimenzovanie Insulation thickness (mm) / Hrúbka izolácie (mm) Min. outside temperatur ( C) / Min. okolitá teplota ( C) Diameter of pipe (inches/mm) / Priemer potrubia (G/mm) ½ ¾ 1 1 ¼ 1 ½ 2 2 ½ Output of heating cable to 1 m (W) / Príkon vykurovacieho vodiča na 1 bm (W) Values in this table apply to the insulations λ=0,05 W/mK / Tabuľka je platná pre izolácie s λ=0,05 W/mK
7 b) Installation The heating cables and sensor must be affixed to the pipe along its entire length using alu num selfadhesive tape, which ensures that the heat is distributed evenly. The temperature sensor must be placed on the coldest point of the pipe. After completing installation, the entire pipe including the heating cables must be covered with insulation. The thickness of the insulation must be the same along the entire length of the pipe. Should the sensor be insulated more than other parts of the pipe, the pipe could freeze. If the sensor is insulated less than other parts of the pipe, the heating cable could overheat. To protect plastic pipe, first cover the pipe with aluminum foil and then seal the cable along its entire length using aluminum tape. When installing the heating circuit, please bear in mind that valves, connections and flanges have greater thermal loss. Therefore, it is necessary to wind the cable in these parts in a closely- spaced manner. b) Montáž Vykurovacie vodiče a senzor sa musia k potrubiu pripevniť po celej dĺžke hliníkovou samolepiacou páskou, ktorá zaručí rovnomerné rozloženie tepla. Senzor teploty musí byť umiestnený na najchladnejšom mieste potrubia. Po montáži je nutné celé potrubie vrátane vykurovacích vodičov obaliť izoláciou. Hrúbka izolácie musí byť po celej dĺžke potrubia rovnomerná, pretože v prípade, že by senzor bol zaizolovaný viac než iné časti potrubia, mohlo by dochádzať k zamŕzaniu potrubia. V prípade, že by senzor bol zaizolovaný menej, dochádzalo by k prehrievaniu vykurovacieho vodiča. V prípade ochrany plastového potrubia, najskôr potrubie obaľte do hliníkovej fólie (alobal) a vodič v celej dĺžke prelepte hliníkovou páskou. Pri inštalácii je nutné brať do úvahy, že ventily, spojky a príruby majú väčšie tepelné straty. Preto je potrebné na tieto časti navinúť vodič hustejšie.
8 c) Regulation For economical operation and safety, it is necessary to install a thermostat with a remote probe placed on the pipe. We recommend using a KABLOREG A1-4, OJ ETV or EBERLE ITR3. Each of these is currently available at FENIX. When using the heating cable to prevent freezing, always set the thermostat to 3 5 C. 4. Warranty, claims ECOFLOOR, supplier of the cable circuits, provides a warranty period of 24 months for the product s functionality, beginning from the date of its installation that is confirmed in the certificate of warranty (installation must be made at latest within 6 months from the date of purchase), provided that: a certificate of warranty and proof of purchase are submitted, the procedure described in this user guide has been followed, data on laying and connecting the cable in the floor and the resulting measured values of the insulation resistance of the heating cable are provided, and the procedure for applying the sealing cement specified by its producer has been followed. Claims may be made in writing at the company that performed the installation, or directly to the manufacturer Provided that the aforementioned conditions were met and the warranty period has expired, the conditions under the claims procedure, clause 5, applies for an additional period of 3 years. The claims procedure also is available at the website c) Regulácia Z hľadiska úspornej prevádzky a bezpečnosti je potrebné inštaláciu vybaviť termostatom s oddelenou sondou umiestnenou na potrubí. Z aktuálnej ponuky firmy FENIX doporučujeme KABLOREG A1-4, OJ ETV alebo EBERLE ITR3. Pri použití vodiča pre nezamŕzajúcu teplotu nastavujeme vždy na termostate teplotu 3 5 C. 4. Záruka, reklamácie Dodávateľ vodičových okruhov ECOFLOOR poskytuje záruku na ich funkčnosť po dobu 24 mesiacov odo dňa inštalácie potvrdenej na záručnom liste (inštalácia musí byť zrealizovaná maximálne 6 mesiacov od dátumu predaja) ak je: doložený záručný list a doklad o zakúpení, dodržaný postup podľa tohto návodu, doložené údaje o skladbe vodiča v podlahe, zapojení a výsledkoch meraní izolačného odporu vykurovacieho vodiča, dodržaný návod výrobcu na aplikáciu tmelov. Reklamácia sa uplatňuje písomne u firmy, ktorá realizovala inštaláciu, pripadne priamo u výrobcu. Pri dodržaní vyššie uvedených podmienok a po uplynutí záručnej doby platia po dobu ďalších 3 rokov podmienky podľa reklamačného poriadku, bod č. 5. R eklamačný poriadok je taktiež na FENIX SLOVENSKO s.r.o. Iliašská cesta Banská Bystrica tel.: 048/ fax: 048/ [email protected]
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE
Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE Commercial Products Type FLX TM Freezer Floor Frost Heave Protection DESIGN GUIDE Contents Introduction...2 Application Information... 2-3 Product
www.the Floor Heating Warehouse.co.uk
www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES
SnoTrace Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace INSTALLATION PROCEDURES Refer to the SnoTrace Cable Testing Report for required recording of test data and circuit information. Upon
FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2
FACTORY AUTOMATION Manual Laying loops for Loop detector LC10-1 and LC10-2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
INSTRUKTIONSMANUAL INSTALLATION INSTRUCTION
FROSTSIKRINGSKABEL M/ TERMOSTAT IPX7 NO-FROST HEATING CABLE W/THERMOSTAT IPX7 INSTRUKTIONSMANUAL INSTALLATION INSTRUCTION 2 M: Art nr 600002 EAN nr 5709133560041 4 M: Art nr 600004 EAN nr 5709133560058
The original heating cable just got better
The making of the DEVIflex heating cable IEC 60800:2009 approved PVC outer sheath Install down to -5 C Round construction 360 full screening The original heating cable just got better DEVIflex Strong.
INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
Ústredná knižnica FaF UK informuje svojich používateľov o prístupe do ONLINE VERZIE EUROPEAN PHARMACOPOEIA (EP)
Ústredná knižnica FaF UK informuje svojich používateľov o prístupe do ONLINE VERZIE EUROPEAN PHARMACOPOEIA (EP) 1. Vstup cez webovú stránku fakulty: http://www.fpharm.uniba.sk/index.php?id=2415 alebo cez
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
Federation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu [email protected] Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 Use of
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
0.3 mm Contact Pitch, 0.9 mm above the board, Flexible Printed Circuit ZIF Connectors.
0.3 mm Contact Pitch, 0.9 mm above the board, Flexible Printed Circuit ZIF Connectors. FH Series (51pos. type) 3.45mm 17.1mm 0.9mm Features 1. Extremely light weight The largest version, with all contacts
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com
Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Electric Heat Tracing INSTALLATION PROCEDURES
INSTALLATION PROCEDURES The following installation procedures are suggested guidelines for the installation of a Thermon electric heat tracing system 1. Individuals installing these products are responsible
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
Pipe Clamps and Accessories
Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
The Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
ScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
building applications copper - redefined
building applications copper - redefined copper - redefined The task The development of an innovative tube for the future: economical, environmentally friendly, ecological, completely safe and easy to
FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS
Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL
FLEXIBLE THERMAL INSULATION MADE OF SILICONE 2012-06
FLEXIBLE THERMAL INSULATION MADE OF SILICONE 2012-06 Table of Contents 1. Flexible, thermal insulation made of Silicone...3 1.1 Features and benefi ts...3 1.2 Designs...3 1.3 Silicone processing at Winkler...3
Cold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
: Architectural Lighting : Interiérové svietidlá
SEC Lighting : Architectural Lighting : nteriérové svietidlá : Shape Harmony : Tradition The company SEC accepts with enthusiasm the challenges of continuously changing world. n our opinion, luminaries
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
Puddle Flange. FRANK Puddle Flange
Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many
SELF-REGULATING PIPE TRACING HEATER CABLE
SELF-REGULATING PIPE TRACING HEATER CABLE Installation & Operation Manual TABLE OF CONTENTS GENERAL INFORMATION... 1 How Heating Systems Work...1 PRODUCT SELECTION... 1 RECEIPT & STORAGE... 1 Receipt...1
Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale
Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
Network Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
The calculus and simulation of underfloor heating systems
The calculus and simulation of underfloor heating systems DORIN CRISTIAN NĂSTAC*, IOAN CĂLDARE**, IOAN GIURCA***, CORNEL MUNTEA*** * Building Services Engineering Department, Transilvania University of
RayClic Connection System Installation Instructions
RayClic Connection System Installation Instructions Description RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit These kits are for use with Raychem IceStop, XL-Trace
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P2.6.3.2. Thermodynamic cycle Heat pump
Heat Thermodynamic cycle Heat pump LD Physics Leaflets P2.6.3.2 Investigating the function of the expansion valve of the heat pump Objects of the experiment g To study the operational components of the
RayClic Connection System Installation Instructions
F M -W RayClic Connection System Installation Instructions RayClic WARNING: Shock Hazard 718K Pipe Heating Cable with HWAT, IceStop, also Listed De-icing and and XL-Trace heating Snow Melting Equipment
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables
1. GENERAL INFORMATION Description Snow or ice dams that have built up on a roof can cause water damage to the interior of homes as well as damage to gutters and downspouts. This custom TXLP/1 single conductor
Underfloor Heating Mat
Installation Manual: Underfloor Heating Mat TECHNICAL HELPLINE 0845 345 2288 IMPORTANT Read this manual before attempting to install the heater. Incorrect installation could damage the heater and will
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities
ZPU MIĘDZYRZECZ PREINSULATED PIPE Detection of Pipe Leaks in Thermal Utilities Assembly Manual Principles of Assembly and Servicing ZAKŁAD PRODUKCYJNO USŁUGOWY Międzyrzecz Polskie Rury Preizolowane Sp.
Pictorial Index... A-14 Introduction to Heat Trace Cable Systems... 6-2 Installation Examples... 6-3 Engineering Guide... 6-4 Heat Loss Tables...
Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss
White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection
White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls
Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems
Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers
Vapor Chambers A vapor chamber is a high-end thermal management device that can evenly dissipate heat from a small source to a large platform of area (see Figure 1). It has a similar construction and mechanism
Product Specification
Sheet 1/7 Polymer Lithium-ion Battery (For high discharge ratio battery) Model:GEB201212C General Electronics Battery Co., Ltd. Address: Huihuang Industrial Building, Huada Road, Dalang, Longhua, Baoan
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors
PD-0050 Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors Page: 1 of 10 Table of Contents 1.0 SCOPE...2 2.0 PRODUCTS TESTED...2 2.1 Cables Tested...3 3.0 GENERAL CONDITIONS...4 3.1
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
www.jameco.com 1-800-831-4242
Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. SPECIFICATION CUSTOMER: JAMES DATE: 04.08.23 MODEL NO: DBU090030 DESIGNED
STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.
STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
Product Specification
Specification No. Q/WAPL523334-1011 Polymer Lithium-ion Battery Model:523334 500mAh Prepared by:sunping Checked by:zhu Qi Approve by: Jin Gang All 10 pages 1 Scope 2/10 This product specification describes
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
NI-ZN BATTERY SPECIFICATION
NI-ZN BATTERY SPECIFICATION 252000 Model Name: AA2500mWh(Ni-Zn) Issued Date: Sept. 2010 NICKEL ZINC BATTERY SPECIFICATION 1.APPLICATION The applicable range: This specification is available only for the
Series 510 Submersible Level Transmitters
Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable
ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.
Two-component flexible, waterproofing and protective cementitious grout. 1504-2 PI-MC-IR Technical features Two-component grout, based on cements, selected aggregates, special additives and synthetic polymers
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
Please read operating instructions carefully before use and keep for further reference.
GB OPERATING INSTRUCTIONS LEISTER Welding-Pen R Hot air tool Please read operating instructions carefully before use and keep for further reference. APPLICATION The LEISTER Welding-Pen R is a hot air tool
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
The Solid Wood Flooring Company Unit 1 Helena Court, Hampton Street, Tetbury, Gloucestershire GL8 8JN
The Solid Wood Flooring Company Unit 1 Helena Court, Hampton Street, Tetbury, Gloucestershire GL8 8JN London Office: The Building Centre, Store Street WC1E 7BT Tel: 01666 504015 Fax: 05603 146907 Mobile:
Product Specification
==== Specification No. = Edition No. ====== ===== =1.0====== Polymer Lithium-ion Battery Product Specification Model:503562 1200mAh Hunan Sounddon New Energy Co., Ltd Address:No.98, Fuzhou Road,Jinhua
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
Ontario Electrical Safety Code - Info Sheet
Ontario Electrical Safety Code - Info Sheet The following are the Code requirements and explanatory material for buried electrical wiring that are applicable to most residential applications. 12-012 Underground
0.2 mm Pitch, 0.9 mm above the board, Flexible Printed Circuit ZIF Connectors
0.9 0.2 mm Pitch, 0.9 mm above the board, Flexible Printed Circuit ZIF Connectors FH43B Series Space saving 17.8mm(81 pos. shown) 2.77 Can be mounted over conductive traces. Features 1. Low-profile, small
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS
EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS Thermal Properties ENGR 3350 - Materials Science Dr. Nedim Vardar Copyright 2015 Thermal Properties of Materials Engage: MSEIP Engineering Everyday Engineering
VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260
THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260 STANDARD THERMOSTAT KIT 1.0 KIT CONTENTS Parts included: 1 x Thermostat 1 x Wall plate 2 x Mounting box screws 1 x Floor temperature
How to build a Pizza Oven in 4 days
How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc. Abstract The technology for connecting lead and magnet wires for electric motors and electro mechanical devices
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE
Mapeguard WP System ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE Products used: Mapeguard WP 200, Mapeguard ST, Mapeguard IC, Mapeguard EC, Mapeguard WP
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
Calculation panel heating/cooling
Calculation panel heating/cooling 3.2.200 Page Customer Building object MultiDRAW Street Street Postal code/city Postal code/city Tel. Country Deutschland EMail Planner MULTIBETON GmbH Heating specialist