The 'FM-1000' How To Guide
|
|
|
- Avice Gilmore
- 9 years ago
- Views:
Transcription
1 The 'FM-1000' How To Guide
2 Contents Title FM-1000 "How To Guide" Table of contents Section/Page 1. Administration Password... 1/3 2. Firmware 2.1 Check the Firmware Version... 2/3 2.2 Check USB stick compatibility... 2/3 2.3 Downloading firmware... 2/4 2.4 Unzipping firmware and placing firmware onto USB Stick... 2/5 2.5 Updating the Screen... 2/5 3. Upgrading features & Unlock codes 3.1 FM1000 Receiver/Screen Unlocks... 3/6 3.2 Upgrading to OmniSTAR... 3/6 3.3 Upgrading to RTK... 3/7 3.4 Installing Rover Radio... 3/8 3.5 Unlocking Features... 3/9 4. Configuring the Receiver 4.1 EGNOS... 4/ OmniSTAR... 4/10 i. OmniSTAR ID... 4/10 ii. Convergence Time... 4/ RTK... 4/ VRS... 4/11 5. Installation of Equipment 5.1 Correctly Mounting the Antenna... 5/ Upgrading the Antenna... 5/ Mounting the Screen... 5/13 6. Screen Add On's 6.1 Connecting EZ Steer... 6/ Coverage Switch... 6/ Radar Out... 6/ NMEA Out... 6/17 7. Data Management 7.1 Field Management... 7/ Summary Reports... 7/20 2
3 1. Administration Password The FM-1000 Administration password is 2009, this password will have to be entered when trying to change any of the 'Configuration' menu settings. 2 - Firmware Figure 1.1 Note: Firmware is the software that runs the EZ Guide screen. Firmware/Software must be up to date to ensure satellite configurations and the latest features are installed on the screen. 2.1 Firmware Version On the home screen choose the 'system information' tab. The software version is displayed on the left hand side of the screen as shown in figure 2.1. Figure Check USB stick compatibility Please note that not all USB sticks are compatible with the FM-1000 screen. Some (Not all) FAT/FAT32 USB sticks are compatible with the screen. The colour of the USB stick icon will show the status of the USB stick as shown in Figure 2.3. Compatible USB sticks can be ordered through CNH Parts. Part No Figure 2.2 Figure 2.3 3
4 2.3 Downloading firmware FM-1000 firmware can be got from the CNH Trimble Support Page, this can be accessed through the assist home page. When logged into assist home page, choose 'Auto-guidance support files, download equipment and advice' shown in [Figure 2.6]. Click on the 'Auto-guidance' link. [Figure 2.4] From the link that opens chose the 'Trimble AutoPilot and EZ Support files'. [Figure 2.5] This opens the 'Trimble Support Page'. Under the product listing drop down box choose FM From the 'File/Document Type' choose the 'Firmware' option and click the search icon [Figure 2.6] Figure 2.7 4
5 2.4 Unzipping firmware/preparing USB stick Once downloaded the ZIP file should then be copied to the root (first) folder of a compatible USB stick. The file must then be Unzipped before it can be used. This can be done by right clicking on the file and selecting 'extract here' as shown in [Figure 2.8]. Note: The computer programme WinZip is needed to Unzip the file before the USB stick can be inserted into the FM Figure Updating the Screen To upgrade the fm FM-1000, on the support tab on the home screen press the 'Upgrade' button. In the new window, the newer level of firmware will appear in the 'Firmware' box, the upgrade icon will become active and pressing this will allow the firmware to be updated. Note: For an AutoPilot steering system please ensure the Trimble NAVII controller has been updated with the latest level of software also. Figure 2.9 Figure
6 3 Upgrading features & Unlock codes 3.1 FM-1000 Receiver/Screen Unlocks I. EGNOS to OmniSTAR II. OmniSTAR to RTK III. Glonass IV. Second Antenna V. TrueTracker VI. TrueGuide VII. Variable Rate & Section Control Figure Upgrading to OmniSTAR The EGNOS to OmniSTAR Part Number is The dealer must place an order with SAP. Then he must send an to with following information : I. Serial number of the screen II. CNH part number III. SAP order number The Customer must then purchase a subscription for a HP or XP correction signal from OmniSTAR (for info please visit Once the upgrade code has been ordered, A minimum of 2 full days is necessary to send back the Upgrade code. Also included in the Upgrade is a new level antenna which is needed to replace the Ag15 antenna that comes with the EGNOS level FM The Ag15 can receive an EGNOS signal. Figure 3.2 Figure 3.4 Figure 3.3 6
7 The Upgrade code must then be entered in to the screen. Choosing the 'Support' tab on the 'Home' screen and pressing the 'Unlocks' button and choosing the correct unlock feature Note: The serial number asked for on the OmniSTAR order form is the OmniSTAR User ID number and not the screen serial number, both are on the 'Support' Tab on the home screen, shown in [Figure 3.2] & [Figure 3.3]. Figure Upgrading to RTK The RTK upgrade code can be received using the same method as that of EGNOS to OmniSTAR. The same antenna used for OmniSTAR can be used for RTK. The FM needs an Internal radio module to pick up the RTK signal. If the FM-1000 has got the radio module it will have a sticker. If the FM screen doesn't have the radio, see the installing Radio module section below. Figure 3.5 Note: If the VRS Ag3000 modem is being used then the FM-1000 will not need the radio module. It will only need to be unlocked to a RTK level. 7
8 please do not open the anti-static package 3.4 Installing Radio Module Order the FM radio module kit with: Unlock code P/N: ZTN69523 Radio Module P/N: ZTN that contains the radio board. Components are ESD sensitive and could be damaged. Upon receipt of the radio kit, please send the FM-1000TM display, radio kit and the attached form filled in to our Service Provider : GEO-KONZEPT GmbH, Gut Wittenfeld Adelschlag, Bayern GERMANY Note : please send the radio module only with the FM-1000TM display to the Service Provider. All other parts are not required for the installation. The Service Provider will complete the following actions within 3 to 5 days (excluding shipping time) : 1. Perform a pre-test on the equipment 2. Install the upgrade components 3. Upgrade the firmware 4. Test the radio to verify operation The FM-1000TM display with installed radio will be returned to the location specified on the form. Notes : When sending the radio and the FM- 1000TM display to the Service Provider, 8
9 The Service Provider will install the radio. Cost of the radio installation is covered by the supplier. You are responsible for all the freight costs, shipping to and from the Service Provider (incl. insurance if required). Up to you to include these additional costs into the price to the customer. 3.5 Screen Unlocks For the screen unlocks shown below, the method shown in sections 3B. I. Glonass - P/N: ZTN69525 II. Second Antenna - P/N: III. TrueTracker - P/N: ZTN69537 IV. TrueGuide - P/N: ZTN69538 V. Variable Rate - P/N: ZTN69540 Note: For the GLONASS unlock code there is a ZEPHER antenna which is needed to replace the Z+ antenna. The Z+ antenna that comes with the OmniSTAR unlock code is unable to receive signal from the GLONASS satellites. 9
10 4 Configuring the Receiver 4.1 EGNOS To configure the EGNOS settings on the FM-1000 screen firstly ensure that the firmware is the latest release (Version 4.0). Having the latest level of Firmware is enough to ensure that the correct EGNOS settings are being used. From the Home screen choose the 'Spanner icon' and then on the right hand corner press 'Configure'. Shown in figure 4.1, from the 'Corrections' drop down box choose WAAS or SBAS depending on the level of firmware installed in the screen. 4.2 OmniSTAR Go to the 'GPS Receiver Settings' screen as shown in figure 4.2. This is the same screen used for choosing the EGNOS and RTK correction. From the corrections drop down box choose 'Omni*' 'XP or HP' which ever has been subscribed to. I. OmniSTAR ID/Free Demo Signal The OmniSTAR ID can be located in the 'Support tab' on the home screen. This ID is used to receive an OmniSTAR signal and an OmniSTAR demo signal. To receive an OmniSTAR demo signal, ring and quote the OmniSTAR ID number, the location, the company and the reason for the demo signal. Either HP or XP can be chosen. Figure 4.1 Figure
11 The signal will last for 3 days. Please refer to section 3B about receiving an OmniSTAR signal. II. Convergence Time To default setting for the OmniSTAR convergence time is 30cm. To prevent long convergence times and frequent drop outs from starting work earlier in the it is possible to increase the convergence time to 150cm. Doing this allows the operator to start working earlier in the day without having to wait for the signal to fully converge. This can be done by going to the RDI screen. Figure RTK Going to the 'GPS Receiver Settings' screen as shown in figure 4.4. Choose RTK from the drop down menu, and then choosing the Channel ID number with is located directly below. Choosing the 'Frequencies' tab the channel settings are located here. Selecting Add/Edit and then entering the relevant RTK frequency ID that the customer wants to pick up. Figure VRS Please refer to the 'VRS Installation Guide' which can be located from the assist home page. 11
12 5. Installation of Equipment 5.1 Correctly mounting the Antenna The antenna should be mounted on the roof of the cab, in the centreline and as far forward as possible (without blocking the signal). The blue square shown in [Figure 4.1] displays where the antenna should be mounted. The antenna must be mounted as far forward as possible because once the tractor goes off line the further forward the antenna is the sooner the FM-1000/EZ Steer can correct the error. [Figure 5.1] 5.2 Upgrading the Antenna At EGNOS level the FM-1000 comes with an Ag15 Antenna. In order to receive an OmniSTAR signal the FM-1000 receiver will have to be upgraded from an EGNOS level to an RTK level. Included in the upgrade is the Unlock code and the upgraded Z+ antenna because the Ag15 antenna can't receive an OmniSTAR signal. When the screen is further unlocked to receive GLONASS satellites, also included in the unlock code is the upgraded ZEPHER(Ag25) antenna. This is the only antenna which can be used to receive GPS and GLONASS satellites. GLONASS cannon must be used when receiving an EGNOS signal because EGNOS only works on GPS satellites [Figure 5.2] 12
13 5.3 Mounting the screen If the FM-1000 screen is being used as a Lightbar then it is recommended that the LB25 External Lightbar is mounted to the front windscreen using a suction cup shown in [Figure 5.3]. The part number for the 'LB25 External Lightbar' suction cup is Figure 5.3 If the FM-1000 screen is being used on AutoPilot/EZ Steer then the most convenient way of mounting the screen is to fix it to the bracket on the right hand door shown in [Figure 5.4]. This is an ideal location for AutoPilot and EZ Steer, also the engage button is in a more convenient location. 5.4 [Figure 5.5] shows the screen mounted at the end of the right hand arm rest. Figure 5.5 Another convenient way of mounting the screen is to use a Baler Bar. This is shown in [Figure 5.6] Figure
14 6. Screen Add On's 6.1 Connecting EZ Steer Figure 5.1 shows how to connect the Fm integrated display with the EZ-Steer assisted system. There are two add on cables needed to connect the EZ Steer system to the FM-1000 that are not included in the EZ Steer kit. These are shown as number 6 and number 7 in [Figure 5.1]. I. No 6 P/N - ZTN75742 II. No 7P/N - ZTN67259 Note: Please ensure that the FM-1000 to EZ Steer cable is plugged in to 'port C' only on the back of the FM-1000 screen, using other ports could damage to the FM Figure Coverage Switch The switch must make and break the connection on pins 10 and 11 on the FmX port connector. Connect pin A of the switch to pin 10 of the 12-pin Deutsch connector on Port A or Port B of the display. Connect pin B of the switch to pin 11 of the 12-pin Deutsch connector on Port A or Port B of the display. Doing this results in the connection being made between pins 10 and 11 of Port A or B of the display when the implement is raised or lowered. 14
15 6.3 Radar Output i. Raven Controller Figure 6.2 shows the FM-1000 with radar output and serial variable rate for a Raven SCS400 or SCS600 controller. FM-1000 Radar output for a raven controller needs cables 11 and 14 from figure (11) - FM-1000 universal radar adaptor P/N - ZTN (14) - Cable, radar speed output, Raven P/N - ZTN64272 Figure 6.2 ii. Rawson Controller Figure 6.3 shows the FM-1000 with radar output and serial variable rate for a Rawson controller. FM-1000 Radar output for a Rawson controller needs cables 11 and 14 from figure (11) - FM-1000 universal radar adaptor P/N - ZTN (14) - Rawson radar speed output cable P/N Figure
16 iii. DICKEY-john/ Hiniker Figure 6.4 shows the FM-1000 with radar output and serial variable rate for a DICKEY-john/ Hiniker controller. FM-1000 Radar output for a DICKEY-john controller needs cables 11 and 13 from figure 6.4. FM-1000 Radar output for a Hiniker controller needs cables 11 and 14 from figure (11) - FM-1000 universal radar adaptor P/N - ZTN (13) - DICKEY-john radar speed output cable P/N - ZTN (14) - Hiniker radar speed output cable P/N - ZTN64273 Figure 6.4 iv. Rawson Controller Figure 6.5 shows the FM-1000 with radar output for a Hardi 5500 controller. FM-1000 Radar output for a Hardi 5500 controller needs cables 11 and 12 from figure (11) - FmX to DE9, RS232 - P/N ZTN (14) - DB9(F) to DB9(F) null modem cable P/N - ZTN59043 Figure
17 6.4 NMEA Out The NMEA message formats are a standard format through which GPS receivers can communicate. If you have an external device connected to the AgGPS Autopilot controller, you can enable NMEA message output from the controller so that the device receives NMEA GPS positions. The messages are output through the Nav Controller harness laptop connector. Some GPS receivers can output NMEA messages to an external device. To do this: I. On the Configuration screen, select the appropriate GPS Receiver plug-in and then tap Setup. The GPS Receiver Settings screen appears. II. Tap NMEA Output: III. Select the appropriate Message Rate and then the Baud Rate. IV. In the Messages Enabled group, select the appropriate NMEA message types to output. Do not just enable all formats. V. Tap OK to continue. Figure 6.7 Figure 6.6 Note To enable NMEA output from another receiver ( for example, the GPS receiver connected to an AgGPS TrueTracker system controller), select the plug-in for that receiver in the plug-in list. 17
18 7. Data Management NOTE: To take data from the FM-1000 a compatible USB stick is needed. Please refer to page 3 for the compatible USB sticks section. 7.1 Field Management The FM-1000 can hold approximately 2GB of data in it internal USB. Once the memory is full then the operator will need to transfer or delete some of the data to be able to continue. The memory available can be seen in the 'System Information' tab on the home screen as 'Storage' (hours). Figure 7.1 I. Sending fields to a USB stick. Choosing the 'Support' tab in the home screen and pressing the 'Data files' button this will open up the 'Data files' menu. A green USB stick symbol means the USB stick is compatible. tapping everything on the internal memory column and then copy will copy all the data from the screen on to the USB stick. Tapping any other option, E.G. fields, will just copy the field information to the USB stick. Once the data is copied then all the data remaining on the screen must be deleted. Figure 7.2 Figure
19 II. Deleting Data To delete data from the screen then choose the 'Support' tab in the home screen and pressing the 'Data files', the 'Delete Data' option is located on the bottom left hand corner of the screen. Choosing this will open the delete data screen. Before the delete data screen opens the administration password must be entered if it hasn't already been entered into the screen. Figure 7.4 In the delete data storage screen there are a number of ways of deleting data from the screen. The field coverage/logging can be deleted by selecting 'Delete All Events' shown in figure 7.7. To delete all the information from the screen then choose the delete everything button. and if it is only selected information that needs to be deleted from the screen then just select the relevant information in the column and press the delete button. Figure 7.6 Figure
20 III. Selecting data from the USB stick When all the field data is saved on the USB stick this can be brought back on to the screen by simply reversing the method that was used to copy the data from the screen to the USB stick. NOTE: This is useful when transferring fields from one screen to another. Figure Summary Reports To view field summary reports, insert a USB Stick and go to 'Configuration, Data Management, Summary Reports, Send Summary Reports to USB'. This will then allow you to choose the field that you want to view the summary report or send all the summary report to the USB Stick. Plug the USB Stick in to the computer, go to "My Computer, USB Disk, AgGPS, Data, (Choose Relevant Client), (Choose Relevant Farm), (Choose Relevant Field), (Choose Relevant Event)" and open up the Word document called "EventSummary.rtf". In this word document there are 6 pages. The information on them is as follows Figure 7.9 Figure
21 I. Event Details II. Map of Overlap III. Map of Height IV. Map of Applied Rate V. Map of Speed VI. Mapped Features Field area, Productive Area, and Total Times are all included in the report along with other information. Figure 6.7 Shows an example of the report. Figure
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE DCM-300 Modem Activation and Setup DCM-300 Modem Overview Setting up the VRS Correction Service Troubleshooting Web Service Tool Over-the-Air Firmware Update FAQ Installation Diagrams
Trimble R8 Base and Rover Quick Setup Guide. Inland GPS Inc.
Trimble R8 Base and Rover Quick Setup Guide Inland GPS Inc. Setting up the GPS Base Equipment Hardware First Find the best, most advantageous secure place to setup the GPS base equipment. Look for a high
GPS Selection Guide. EZ Guide 500 & 250 Trimble #
GPS Selection Guide Trimble FMX 1000 & Case IH FM 1000 Precision Parts Ref Doc Trimble CFX 750 & Case IH FM 750 750 1000 with Hydraulic Steer - Trimble Aftermarket 725599 955443 955439 with Hydraulic Steer
AgGPS 542 Receiver: Enable GLONASS through the Web Browser
15 April 2011 AgGPS 542 Receiver: Enable GLONASS through the Web Browser This document describes how to use the web browser to enable GLONASS on a Trimble AgGPS 542 receiver. Note: Some AgGPS 542 receivers
Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23
Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23 1. Outline 1.1 Operation and Maintenance Terminal The OMT is powerful software when it is incorporated with the repeaters;
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
Trimble Survey Controller Software (TSC2) Connection with mobile phone
Trimble Survey Controller Software (TSC2) Connection with mobile phone In the main Windows screen, pick on the Start menu and then pick settings. In the Wireless Manager disable wireless internet. In the
Shearwater Research Dive Computer Software Manual
Shearwater Research Dive Computer Software Manual Revision 1.3 Table of Contents 1. Basic overview of components 2. O/S IrDA driver installation 2.1 USB IrDA installation for Windows XP Home/Pro editions
User Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software The following document will outline the installation and use of the IF-NMEASC and SC-30 USB drivers and SC-30Tool software in three parts:
HOW TO TRANSFER FILES BETWEEN EEN IDL7000 PVR AND USB2 DEVICE
HOW TO TRANSFER FILES BETWEEN EEN IDL7000 PVR AND USB2 DEVICE CONTENTS CONTENTS...2 FOREWORD...3 TRANSFERRING FILES BETWEEN IDL7000M PVR AND USB2 DEVICE...4 CONNECTING AN EXTERNAL USB2 DEVICE...4 COPYING
X30 Apollo System Upgrading Monitor Software & ECU Firmware
X30 Apollo System Upgrading Monitor Software & ECU Firmware 3.18.513 3.18.513 1. Download zip file attachment to a folder on your computer. File name will be 3.18.513.zip 2. Extract files from the zip
PLM PRODUCT INFORMATION
PLM PRODUCT INFORMATION Agricultural Equipment UK & ROI Precision Farming Reference UK- PLM_03_13 Date: 1st May 2013 Announcing the new RangePoint RTX Correction Service RangePoint RTX is a GPS and GLONASS
DUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges
Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges 1. USB and Serial Communication Ports: Newer DG-700 and DG-500 gauges contain both a USB and a DB-9 Serial Communication Port,
System update procedure for Kurio 7 (For build number above 110)
System update procedure for Kurio 7 (For build number above 110) IMPORTANT NOTE: Before starting the procedure, please check your current Android build number, that can be found as follows: exit the Kurio
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app
User Guide Table of Contents Welcome Setup Use Troubleshooting 2 What s in the box 2 What you need 3 Installing the Blink app 4 Setting up the Sync Module 5 Connecting the Sync Module to Your Wi-Fi 7 Adding
Connecting your Omega/BetaPAT PLUS to a PC via a USB
Connecting your Omega/BetaPAT PLUS to a PC via a USB Install software Windows XP and below Insert the disc into your computers disc drive and run through the setup wizard. Windows Vista & 7 1. Insert the
Evolution Connex Control Field Software Updates Version 12 rev. 20150218
Software updates to the Evolution Connex control may be performed in the field using a USB memory device (USB drive). You will obtain best results using a USB drive that is 2GB, 4GB or 8GB in size, and
Infinity Touch Control Field Software Updates Version 10 rev. 20131112
Software updates to the Infinity Touch control may be performed in the field using a USB memory device (USB drive). You will obtain best results using a USB drive that is 2GB, 4GB or 8GB in size, and is
Tutorial How to upgrade firmware on Phison S5 controller MyDigitalSSD
Tutorial How to upgrade firmware on Phison S5 controller MyDigitalSSD Version 1.3 This tutorial will walk you through how to create a bootable USB drive and how to apply the newest firmware S5FAM030 to
Installing S500 Power Monitor Software and LabVIEW Run-time Engine
EigenLight S500 Power Monitor Software Manual Software Installation... 1 Installing S500 Power Monitor Software and LabVIEW Run-time Engine... 1 Install Drivers for Windows XP... 4 Install VISA run-time...
Sierra Wireless AirCard Watcher Help for Mac OS X
Sierra Wireless AirCard Watcher Help for Mac OS X Sierra Wireless AirCard Watcher allows you to manage and monitor the connection between your modem and the network. With Watcher, you can: Determine signal
EPIC 950 THERMAL TICKET PRINTER
EPIC 950 THERMAL TICKET PRINTER Software Reference Guide www.transac-tech.com 2 Contacting Information / Serial Plate Info TransAct Technologies Incorporated is the manufacturer of Ithaca brand POS, Banking,
RELEASE NOTES. Trimble. SPS Series Receivers. Introduction. New features and changes
RELEASE NOTES Trimble SPS Series Receivers Introduction New features and changes Version 4.41 Revision A April 2011 F Corporate office Trimble Navigation Limited Engineering and Construction group 5475
SMART CONSOLE Software and Firmware Upgrade Procedure
Smart Console Technical Document 114-01 20/04/07 SMART CONSOLE Software and Firmware Upgrade Procedure Overview Professional and Elite Series This document describes the process of upgrading both the software
FOR MORE INFORMATION. 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner
FOR MORE INFORMATION 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner getting to know your telstra pre-paid 4G WI-FI (760S) LET S GET THIS
Maxtor OneTouch User's Guide
EXTERNAL HARD DRIVE Maxtor OneTouch User's Guide TM II P/N:20259600 i Contents 1 Introduction................................................. 1 Maxtor OneTouch II Drive Components............................
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
MS830 / MS833 Barcode Reader v1.0 9-December-2014
MS830 / MS833 Barcode Reader v1.0 9-December-2014 Publication Information 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents
Installation and initial configuration of UI View32, with PMap Server 7 and Precision Mapping Streets and Traveler 8.0 on Microsoft Vista
Installation and initial configuration of UI View32, with PMap Server 7 and Precision Mapping Streets and Traveler 8.0 on Microsoft Vista Background: UI View is considered one of the best Automated Position
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Using the Parani SD1000U/SD1000 with Carlson SurvCE
Using the Parani SD1000U/SD1000 with Carlson SurvCE Table of Contents Installing the Radio Driver...2 Pair the Radios...3 Connecting the Radio to the Total Station...4 Configuring SurvCE...5 Parts List...6
TPG MOBILE BROADBAND QUICK SETUP GUIDE
TPG MOBILE BROADBAND QUICK SETUP GUIDE TPG USB E1762 Modem Thank you for choosing TPG Mobile Broadband and USB E1762 modem. This User Guide provides step by step instructions that will take you through
Select Correct USB Driver
Select Correct USB Driver Windows often installs updated drivers automatically, and defaults to this latest version. Not all of these drivers are compatible with our software. If you are experiencing communications
RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP
RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance
USER S MANUAL. Settop Cell-Xtrem
USER S MANUAL Settop Cell-Xtrem Rev. March 2014 USER S MANUAL 2 Index USER S MANUAL... 1 Settop Cell-Xtrem... 3 Become familiar with the Settop Cell-Xtrem... 4 Become familiar with the Settop Cell-Xtrem
DIAL-UP DATA. User s Guide
DIAL-UP DATA User s Guide Iridium Satellite LLC Rev. 5; January 1, 2003 DIAL-UP DATA SERVICE--------------------------------------------------------------------------------------- TABLE OF CONTENTS 1 Dial-Up
nüvi 1400 series quick start manual
nüvi 1400 series quick start manual for use with these nüvi models: 1410, 1490 2009 Garmin Ltd. or its subsidiaries April 2009 190-01073-01 Rev. A Printed in Taiwan Looking at Your nüvi See the Important
Package Contents: TRADEMARKS
Package Contents: SATA/IDE-USB adapter: 1. SATA/IDE-USB Adapter 2. Power Adapter with On/Off Switch 3. Power Cable 4. SATA Data Cable 5. SATA Power Supply Cable 6. User Manual (Disc) TRADEMARKS Apple,
PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming
Work Off-Line Set up a new database or modify a previously saved database (without being connected to the telephone system). This helps minimize on-site programming time. Work On-Line (connected directly
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL 086-333
ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL 086-333 BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704, Tel: 800-224-6339
Windows XP.. ELITE Firmware Update procedures.. v1.41
Windows XP.. ELITE Firmware Update procedures.. v1.41 Download and Extract the ELITE update. Note.. Please ensure you are logged in to Windows as an Administrator before carrying out the instructions in
ScotEID Desktop Quick Start Guide
ScotEID Desktop Quick Start Guide Last updated 16/01/2013 Table of Contents Table of Contents Supported Readers Installation Java Runtime Environment ScotEID Desktop Configuration General Default Lot ScotEID
HYDROSOFT Version 1.0.2 INSTALLATION AND OPERATING
HYDROSOFT Version 1.0.2 INSTALLATION AND OPERATING Overview The Hydrosoft software allows HG-302 controller users to monitor pool performance directly from a computer. As many as 32 controllers may be
A. I do not have my own personal certificate I am a new client or want to download a new certificate
This user guide will help you to create your personal certificate in file/browser or smart card certificate. If you already own a personal certificate in file that you have saved on your computer, you
OnDemand Version 1.7. Installation Manual and User s Guide. AST Technology. Sophienstrasse 4 32051 Herford Germany
OnDemand Version 1.7 Installation Manual and User s Guide AST Technology Sophienstrasse 4 32051 Herford Germany Contents Overview of OnDemand Software... 1 System and Software Requirements... 1 CVe Monitor
for Windows Media Center User's Guide
for Windows Media Center User's Guide Table of Contents Introduction System Requirements Installation Running HAI Home Control Using HAI Home Control Product Support Introduction Thank you for purchasing
ThinLinX TLXOS 64-bit Firmware Installation Guide for the Intel NUC Range. Materials Required
ThinLinX TLXOS 64-bit Firmware Installation Guide for the Intel NUC Range The Intel NUC is a small form factor computer that incorporates several models from Intel Core processors to the economical Single
Guide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
Step By Step Guide To Setting Up Your System
www.kenwood-electronics.co.uk/vw Kenwood Navigation Systems DNX525DAB Keep up-to-date with the latest software by registering today. Registrate your system on Kenwood s website to receive notifications
F-Series Desktop User Manual F20. English - Europe/New Zealand
F-Series Desktop User Manual F20 en English - Europe/New Zealand Contents Key to icons and text...3 What is F-Series Desktop?...4 How do I install F-Series Desktop onto my computer?...4 How do I subscribe
XConsole GUI setup communication manual September 2010.
XConsole GUI setup communication manual September 2010. XConsole is compatible with Microsoft XP, Vista and Windows 7. The software will also work if using Boot camp on a Mac. IMPORTANT NOTES: - Do NOT
CM HOST CM CardTransporter Fuel Communication and Management Software 10.10.06 Software version up to 3.1
CM HOST CM CardTransporter Fuel Communication and Management Software 10.10.06 Software version up to 3.1 CM Host Manual For CardMaster Fuel Control www.cardlockvending.com customers call 888-487-5040
User s Manual for Fingerprint Door Control Software
User s Manual for Fingerprint Door Control Software Foreword The naissance of F7 indicated that fingerprint reader enters into professional door control domain. That s why we developed this software to
Phaser 3635MFP Software Upgrade Process
Overview Phaser 3635MFP Software Upgrade Process The Software Upgrade feature allows the customer to upgrade the machine software as requested by a Xerox Customer Support Center Representative, without
PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE
PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE INTRODUCTION This technical note provides simple procedures that can be performed in the field to help identify and correct the cause
BUS-WATCH R1001/R4001 Quick Guide Series
Part 1: Video File Source Connection To Review stored video, you must first connect a PC to a video file source. There are 2 ways to connect to the stored video files: Through the Removable Hard Drive
The Parts of the System
2 The Parts of the System THE RECEIVER THE RECEIVER FRONT PANEL Power Light This green light on the receiver front panel lights up when the receiver is turned ON. This light flashes when the receiver memory
SOS SO S O n O lin n e lin e Bac Ba kup cku ck p u USER MANUAL
SOS Online Backup USER MANUAL HOW TO INSTALL THE SOFTWARE 1. Download the software from the website: http://www.sosonlinebackup.com/download_the_software.htm 2. Click Run to install when promoted, or alternatively,
ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter
ABB solar inverters Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter Introduction This document details the procedure for the installation on a user s computer
Configuring the Siemens TC35 modems for use with the MI2292
Configuring the Siemens TC35 modems for use with the MI2292 The following instruction describe how to set up GSM communication between an MI2292 Power Quality Analyser Plus and a computer 1. Equipment
ROYAL REGISTERLINK USER'S GUIDE
1 1 ROYAL REGISTERLINK USER'S GUIDE 2 Royal RegisterLink Help 2 Contents About RegisterLink 3 Support 4 Important Information 5 How the data maps 6 Daily Procedure using RegisterLink 7 Installing RegisterLink
PC Instructions for Miller LiveArc Software
PC Instructions for Miller LiveArc Software Contents Instructions for Installing LiveArc Software on a PC... 2 Instructions for Loading Data from the LiveArc System onto a PC... 10 Instructions for Transferring
History of Revisions. Ordering Information
No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is
Web'n'walk. Manager. for Windows USER MANUAL
Web'n'walk Manager for Windows USER MANUAL Content 03 Introduction 04 Hardware and Software Requirements 04 Connecting Your Device to the Computer 05 User Interface 05 Selecting Network 06 Connecting to
User s Manual. Management Software for ATS
ATS Monitor User s Manual Management Software for ATS Table of Contents 1. ATS Monitor Overview... 2 2. ATS Monitor Install and Uninstall... 2 2.1. System Requirement... 2 2.2. Software Install... 2 2.3.
Note: With v3.2, the DocuSign Fetch application was renamed DocuSign Retrieve.
Quick Start Guide DocuSign Retrieve 3.2.2 Published April 2015 Overview DocuSign Retrieve is a windows-based tool that "retrieves" envelopes, documents, and data from DocuSign for use in external systems.
Downloading <Jumping PRO> from www.vola.fr-------------------------------------------- Page 2
Downloading from www.vola.fr-------------------------------------------- Page 2 Installation Process on your computer -------------------------------------------- Page 5 Launching
AUDITVIEW USER INSTRUCTIONS
The AuditGard AuditView software allows the Manager to view, save, and print the audit records. The AuditGard lock maintains the last 512 lock events in non-volatile memory. Accessing the audit records
USB VoIP Phone Adapter. User s Manual
USB VoIP Phone Adapter User s Manual FCC Certifications This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 68 of the FCC Rules.
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
FOR MORE INFORMATION CALL 125 8880 or FROM A NON-TELSTRA PHONE, CALL 13 2200 AND SAY PRE-PAID VISIT telstra.com/ppmbb VISIT A TELSTRA STORE OR PARTNER GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
Iridium Extreme TM Satellite Phone. Data Services Manual
Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...
Getting the most from your Maxtor OneTouch TM USB hard drive and Linksys Network Storage Link
Getting the most from your Maxtor OneTouch TM USB hard drive and Linksys Network Storage Link Share your OneTouch drive with everyone on your network. With the Linksys Network Storage Link, you can now
PekaoBIZNES 24 QUICK Start. User Guide First steps in the system
PekaoBIZNES 24 QUICK Start User Guide First steps in the system INTRODUCTION Managing your finances may be really convenient. After completing the steps outlined in this document, you will join a big group
Hello Modem. Today I would like
Quick Setup Guide Hello Modem. Today I would like to Start from scratch 1 Plug Modem in 3 Connect a computer to Modem 7 Learn how to view Modem settings 21 Change my wireless network name 22 Change my
Application Note: Connecting to a 2500 Series Processor using PLC Workshop
Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The
Printer Support Guide. FedEx Ship Manager Software
Printer Support Guide FedEx Ship Manager Software Printer FAQs Installing Printer Drivers How do I download and install the Zebra printer drivers? To download and install the current Zebra printer drivers
C-Nav1010 Receivers Only C-Nav1010M and C-Nav1010R Models
C-Nav1010 Receivers Only C-Nav1010M and C-Nav1010R Models This firmware build will only function in C-Nav1010 receivers containing the SF-2110 GPS Engine. Important Update the receiver with a consistent
Trimble TerraSync User Guide for Laser GPS Offset
Trimble TerraSync User Guide for Laser GPS Offset Intro Trimble TerraSync software is designed for fast and efficient field GIS data collection and maintenance. Integrating all the ways you collect data
How to downgrade Samsung Galaxy Tab 2 back to original V4.1.1 Android OS
How to downgrade Samsung Galaxy Tab 2 back to original V4.1.1 Android OS Important information: This procedure restores the Samsung Galaxy tablet, used with the 1750 Fluke Power Recorder product back to
Plena Voice Alarm System Firmware update
Plena Voice Alarm System Firmware update 1. Introduction It is advised to update a Bosch Plena Voice Alarm System with the latest released firmware. This Application Note describes how a firmware update
COBRA Reprogramming Instructions
COBRA Reprogramming Instructions The purpose of this document is to provide instructions on how to setup and use the COBRA reprogrammer to update the software on your COBRA firing system. 1 It s a little
Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment
Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment Version 2.0 This tutorial will walk you through how to create a bootable USB drive to enter into a WINPE
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-21 Case IH Puma 165 Puma 180 Puma 195 Puma 210 New Holland T7030 T7040 T7050 T7060 Revision A June 2007 Part Number 53345-21-EU2
EPSON Stylus COLOR 740. USB Software Installation Guide (Windows 98/iMac ) USB Setup Guide (imac)
EPSON Stylus COLOR 740 TM USB Software Installation Guide (Windows 98/iMac ) USB Setup Guide (imac) This guide includes USB setup instructions for your imac computer, as well as software installation instructions
Installing the Gerber P2C Plotter USB Driver
Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing
atbusiness Deposit Installation Guide Table of Contents
Installation Guide atbusiness Deposit Installation Guide Table of Contents Merchant Installation Technical Requirements...3 Overview...4 Setup CAR...6 Download Device Driver...9 Merchant Capture Merchant
User Manual. Windows 7 / Vista / XP. iotablet Driver
User Manual Windows 7 / Vista / XP iotablet Driver I. General Information 2 1. Overview 2 2. Pen Tablet Function 2 3. System Requirements 2 4. Driver Installation 3 5. Hardware Installation 3 6. Verifying
CashFlow Programming Module CPM
CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
Quick Start Guide Vodafone Mobile Broadband USB Stick. Designed for Vodafone
Quick Start Guide Vodafone Mobile Broadband USB Stick Designed for Vodafone Welcome to the world of mobile communications 1 Welcome 2 Set up your USB Stick 3 Start the software 4 Software overview (Microsoft
Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM
Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation
Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.
Instrument Software Update Instructions Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Purpose Upgrading an older version to A.12.09 and above The purpose of this document is to outline the instrument
Bluetooth Installation
Overview Why Bluetooth? There were good reasons to use Bluetooth for this application. First, we've had customer requests for a way to locate the computer farther from the firearm, on the other side of
Pioneer AVIC Z140BH and AVIC X940BT firmware update (v4.600) for iphone with Lightning connector compatible with AppRadio Mode
Pioneer AVIC Z140BH and AVIC X940BT firmware update (v4.600) for iphone with Lightning connector compatible with AppRadio Mode Update instructions for navigation models: AVIC-Z140BH and AVIC-X940BT Download
