LOW NOX MODULATING DUAL FUEL BURNERS
|
|
|
- Alfred Austin
- 9 years ago
- Views:
Transcription
1 OW OX MODUATIG DUA FUE BURERS RS/M MX SERIES RS 68/M MX FS1 2/35 86 kw RS 68/M MX FS2 2/35 86 kw RS 12/M MX FS1 3/6 12 kw RS 12/M MX FS2 3/6 12 kw RS 16/M MX FS1 3/ kw The RS/M MX series of burners covers a firing range from 2 to 184 kw, and they have been designed for use in hot or superheated water boilers, hot air or steam generators, diathermic oil boilers. Operation is two stage at the oil side and modulating at the gas side with the installation of a PID logic regulator and respective probes. RS/M MX series burners guarantees high efficiency levels in all the various applications, thus reducing fuel consumption and running costs. Optimisation of sound emissions is guaranteed by the special design of air suction circuit and the use of sound proofing material. The exclusive design ensures reduced dimensions, simple use and maintenance. A wide range of accessories guarantees elevated working flexibility. TS64UK1
2 TECHICA DATA Model RS 68/M MX RS 12/M MX RS 16/M MX Approval Emissions Electrical data Fuel / air data Burner operation mode Modulation ratio at max. output Servomotor run time Heat output Working temperature net calorific value Oil viscosity delivery Pump delivery Atomised pressure Fuel temperature Fuel preheater net calorific value G2 density gas delivery net calorific value G25 density gas delivery net calorific value PG density gas delivery Fan Air temperature Electrical supply Auxiliary electrical supply Control box Total electrical power Auxiliary electrical power Heaters electrical power Protection level Pump motor electrical power Rated pump motor current Pump motor start up current Pump motor protection level Fan motor electrical power Rated fan motor current Fan motor start up current Fan motor protection level Ignition transformer Operation Sound pressure Sound power CO emission grade of smoke indicator Oil CxHy emission Ox emission CO emission G2 Ox emission Directive Conforming to Certification type s kw Mcal/h C min./max. kwh/kg mm 2 /s (cst) kg/h type kg/h bar max. C kwh/m 3 kg/m 3 m 3 /h kwh/m 3 kg/m 3 m 3 /h kwh/m 3 kg/m 3 m 3 /h type max C Ph/Hz/V Ph/Hz/V type kw kw kw IP kw A A IP kw A A IP type V1 V2 I1 I2 db (A) W mg/kwh Bacharach mg/kwh mg/kwh mg/kwh mg/kwh two stages light oil two stages progressive/modulating gas 1 2 (light oil) / 1 4 (gas) SQ / /6 12 3/ / / / /4 11, / / / J6 C J7 C 23/ /4 23 (at 12 bar) 12 6 O,71 3/6 12 8,6,78 35/ ,8 2,2 3/ /8 214 reverse blade fan straight blade fan 3 1,5 5,9 3,4 35, /5/234~(±%) 1/5/23~(±%) F (FS1) GK 16 (FS2) 3,7 1,5 44,55 3,6 9,5 44 2,2 8,8 5,1 52,8 3, V 2x5 kv 1,9A 3mA 6, 4,5 15,8 9, ,8 FS1 intermittent (1 stop each 24 h) FS2 continuos (1 stop each 72 h) < < 1 < < 185 < < 8 99/396 88/336 72/23 EEC E 267 E 676 8,5 CE 85BP175 CE 85B625 Reference conditions: Temperature: 2 C Pressure: mbar Altitude: m a.s.l. oise measured at a distance of 1 meter. Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIEO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part. 2
3 FIRIG RATES RS 12/M MX RS 16/M MX RS 68/M MX mm H 2 O hpa (mbar) Mcal/h kw Useful working field for choosing the burner Modulation range Test conditions conforming to E 267 E 676: Temperature: 2 C Pressure: mbar Altitude: m a.s.l. 3
4 FUE SUPPY GAS TRAI The burners are fitted with a butterfly valve to regulate the fuel, controlled by a variable profile cam servomotor. Fuel can be supplied either from the right or left hand sides. A maximum gas pressure switch stops the burner in case of excess pressure in the fuel line. The gas train can be selected to best fit system requirements depending on the fuel output and pressure in the supply line. The gas train can be Multibloc type (containing the main components in a single unit) or Composed type (assembly of the single components). MUTIBOC gas train type MBD P MUTIBOC gas train type MBC 12 P P2 6 5 P COMPOSED gas train P2 7 5 P Example of the variable profile cam 1 Gas input pipework 2 Manual valve 3 Antivibration joint 4 Pressure gauge with pushbutton cock 5 Filter 6 Pressure regulator (vertical) 7 Minimum gas pressure switch 8 VS safety solenoid (vertical) 9 VR regulation solenoid (vertical) Two settings: firing output (rapid opening) maximum output (slow opening) Gasket and flange supplied with the burner 11 Gas adjustment butterfly valve 12 Burner 13 Seal control mechanism for valves 89. According to standard E 676, the seal control is compulsory for burners with maximum output above 12 kw (in gas train with seal control) 14 Gas trainburner adapter 15 Maximum gas pressure switch P1 Combustion head pressure P2 Pressure downstream from the regulator P3 Pressure upstream from the filter Gas train supplied separately, with the code given in the table 1 Installer s responsibility 12 P P2 5 P
5 Y Y Example of gas train COMPOSED type without seal control Øo Øi Z X Example of gas train MUTIBOC type without seal control Øo Øi Z X Gas trains are approved by standard E 676 together with the burner. The overall dimensions of the gas train depends on how they are constructed. The following table shows the maximum dimensions of the gas trains that can be fitted to RS/M MX burners, intake and outlet diameters and seal control if fitted. Please note that the seal control can be installed as an accessory, if not already installed on the gas train. The maximum gas pressure of gas train Multibloc type is 36 mbar, and that one of gas train Composed type is 5 mbar. MUTIBOC guarantees a range of pressure toward the burner from 3 to 6 mbar. For version D 65 and D 8 is from 2 to 4 mbar. The range of pressure in the MUTIBOC with flange can be modified choosing the stabiliser spring (see gas train accessory). ame Code Ø i Ø o X mm Y mm Z mm Seal Control COMPOSED MUTIBOC GAS TRAIS GAS TRAIS MBD 42 MBD 42 CT MBC 12 SE 5 MBC 12 SE 5 CT MBC 19 SE 65 FC MBC 19 SE 65 FC CT MBC 3 SE 8 FC MBC 3 SE 8 FC CT D 65 D 65 D 8 D D 65 D 65 D 8 D
6 PRESSURE DROP DIAGRAM The diagrams indicate the minimum pressure drop of the burners with the various gas trains that can be matched with them; at the value of these pressure drop add the combustion chamber pressure. The value thus calculated represents the minimum required input pressure to the gas train. RS 68/M MX P Combustion head and gas train Combustion head mbar G MB 42 MB 12 SE ATURA GAS G Gas train MBD 42 MBD 42 CT MBC 12 SE 5 MBC 12 SE 5 CT Code Adapter Seal Control Accessory 15 Pressure drop kcal/h X kw RS 12/M MX P Combustion head and gas train Combustion head mbar G MB 42 MBC 12 SE MBC 19 SE G Gas train MBD 42 MBD 42 CT MBC 12 SE 5 MBC 12 SE 5 CT MBC 19 SE 65 FC MBC 19 SE 65 FC CT Code Adapter Seal Control Accessory 2 Pressure drop kcal/h X RS 16/M MX P Combustion head and gas train Combustion head mbar Pressure drop kw G G kcal/h X MB 42 MBC 12 SE MBC 19 SE MBC 3 SE kw Gas train MBD 42 MBD 42 CT MBC 12 SE 5 MBC 12 SE 5 CT MBC 19 SE 65 FC MBC 19 SE 65 FC CT MBC 3 SE 8 FC MBC 3 SE 8 FC CT Code Adapter Seal Control Accessory note Please contact the Riello Burner Technical Office for different pressure levels from those above indicated and refer to the technical manual for the correct choice of the spring. 6
7 2" 3" 6" 4" SEECTIG THE FUE SUPPY IES The following diagram enables pressure drop in a preexisting gas line to be calculated and to select the correct gas train. The diagram can also be used to select a new gas line when fuel output and pipe length are known. The pipe diameter is selected on the basis of the desired pressure drop. The diagram uses methane gas as reference; if another gas is used, conversion coefficient and a simple formula (on the diagram) transform the gas output to a methane equivalent (refer to figure A). Please note that the gas train dimensions must take into account the back pressure of the combustion chamber during operations. Control of the pressure drop in an existing gas line or selecting a new gas supply line. The methane output equivalent is determined by the formula fig. A on the diagram and the conversion coefficient. Once the equivalent output has been determined on the delivery scale ( V ), shown at the top of the diagram, move vertically downwards until you cross the line that represents the pipe diameter; at this point, move horizontally to the left until you meet the line that represents the pipe length. Once this point is established you can verify, by moving vertically downwards, the pipe pressure drop of on the botton scale below (mbar). By subtracting this value from the pressure measured on the gas meter, the correct pressure value will be found for the choice of gas train. Example: gas used G25 gas output 9.51 mc/h pressure at the gas meter 2 mbar gas line length 15 m conversion coefficient.62 (see figure A) equivalent methane output V = 9.51 = mc/h.62 once the value of has been identified on the output scale ( V ), moving vertically downwards you cross the line that represents 1" 1/4 (the chosen diameter for the piping); from this point, move horizontally to the left until you meet the line that represents the length of 15 m of the piping; move vertically downwards to determine a value of 1.4 mbar in the pressure drop botton scale; subtract the determined pressure drop from the meter pressure, the correct pressure level will be found for the choice of gas train; correct pressure = ( 21.4 ) = 18.6 mbar V , PIPE EGTH (m) 2" 1/2 V = Gas output mc/h f 1" 1" 1/4 1" 1/2 3/4 f 1 G2 =,62 G25 {1,18 G31 1/2 Figure A 1,4,1,2,3,4,5,6,7, PRESSURE DROP (mbar) PIPE DIAMETER 7
8 HYDRAUIC CIRCUIT The burners are fitted with three valves (a safety valve and two oil delivery valves) along the oil line from the pump to the nozzle. A thermostatic control device, on the basis of required output, regulates oil delivery valves opening, allowing light oil passage trough the valves and to the nozzle. Delivery valves open contemporary to the air damper opening, controlled by a servomotor. The pumping group is fitted whit a pump, an oil filter and a regulating valve: through this it is possible to manaully adjusts atomised pressure, which in factory is preset at 12 bar. Example of light oil pump of RS 16/M MX burner RS/M MX VS V2 V1 PV U1 U2 P P VS V1 V2 PV U1 U2 Pump with filter and pressure regulator on the output circuit Safety valve on the output circuit 1st stage valve 2nd stage valve ozzle holder 1st stage nozzle 2nd stage nozzle 8
9 SEECTIG THE FUE SUPPY IES The fuel feed must be completed with the safety devices required by the local norms. The table shows the choice of piping diameter, depending on the difference in height between the burner and the tank and their distance. MAXIMUM EQUIVAET EGTH FOR THE PIPIG [m] Model RS 16/M MX Diameter piping Ø12mm Ø14mm Ø16mm +H, H (m) max (m) max (m) max (m) +4, , , , , , , , , , V P +H cm H Ø P V Difference in height pumpfoot valve Internal pipe diameter Max. height m Height 4 m Burner Burner pump Filter Manual shut off valve Suction pipework Bottom valve Remote controlled rapid manual shut off valve (compulsory in Italy) Type approved shut off solenoid valve (compulsory in Italy) Return pipework Check valve H 6 note With ring distribution oil systems, the feasible drawings and dimensioning are the responsibility of specialised engineering studios, who must check compatibility with the requirements and features of each single installation. 9
10 VETIATIO The ventilation circuit produces low noise levels with high performances pressure and air output, in despite of the compact dimensions. The special design of the air suction circuit and the use of soundproofing material keeps noise level very low. A variable profile cam connects the fuel and air regulations, ensuring high fuel efficiency at all firing ranges. A minimum air pressure switch stops the burner when there is an insufficient quantity of air at the combustion head. Example of the servomotor for air/gas setting COMBUSTIO HEAD Different lengths of the combustion head can be chosen for the RS/M MX series of burners. The choice depends on the thickness of the front panel and the type of boiler. Depending on the type of generator, check that the penetration of the head into the combustion chamber is correct. The internal positioning of the combustion head can easily be adjusted to the maximum defined output by adjusting a screw fixed to the flange. note The burners of RS/M MX series are not suitable to be installed on boiler with reverse flame chamber. Example of RS 16/M MX burner combustion head. Flame dimensions 4 3 max min 2 1,5 D Flame lenght (m) 2 1 D max D min Burner output (MW) 1,5 Flame diameter (m) Example: Burner thermal output = 2 kw; flame (m) = 2,7 m (medium value); D flame (m) =,8 m (medium value)
11 ADJUSTMET BURER OPERATIO MODE The RS/M MX series of burners can have two stage operation at the oil side and modulating operation at the gas side with the installation of a PID logic regulator and respective probes. When burner is supplied with light oil a modulation ratio of 2:1 is reached thanks to the two nozzles solution; when burner is supplied with gas modulation ratio is 6:1. The air is adapted to the servomotor rotations. Example of a regulator On two stage operation, the burner gradually adjusts output to the requested level, by varying between the two preset levels (see figure A). Two stage operation Output Controlled variable C bar MAX MI time time Figure A In modulating operation, normally required in steam generators, in superheater boilers or diathermic oil burners, a specific regulator and probes are required. These are supplied as accessories that must be ordered separately. The burner can work for long periods at intermediate output levels (see figure B). Modulating operation Output Controlled variable Figure B C bar MAX MI Time Time START UP CYCE Thermostat closes. The motor starts running The servomotor opens the air damper Prepurge with air damper open The servomotor takes the air damper to the firing position. 7 Preignition 76 Solenoid security valve VS and V1 1st stage valve open; 1st stage flame 79 After 3 firing the ignition transformer switches off (if flame is detected, otherwise there is a lockout) 88 If heat request is not yet satisfied, 2nd stage solenoid valve V2 opens and at the same time servomotor open completely the air damper. The starting cycle comes to an end. 2nd stage flame. RS /M MX 11
12 WIRIG DIAGRAMS Electrical connections must be made by qualified and skilled personnel, according to the local regulations. Example of the terminal board for electrical connections for the RS/M MX model TWO STAGE PROGRESSIVE OPERATIO RS/M MX without seal control MB PE S3 R3 T1 T2 P1 P2 T6 T7 T8 3 V21 V11 M PT1 PT3 PT5 DC+ DC GD D1 PE PE ph ~ 5Hz 4/23V M 3 ~ F TS P ϑ T6A S 1ph ~ 5Hz 23V PS T P ϑ I PG P TR ϑ P VR VS MB Burner terminal board TS Safety thermostat S External lockout signal I Manual switch T Threshold thermostat TR High/low flame setting thermostat T6A 6A fuse F Fuse (see table A) ead section (see table A) PG Minimum gas pressure switch PS ockout reset button VR Adjustment valve VS Safety valve RS/M MX with seal control MB PE PE ph ~ 5Hz 4/23V M 3 ~ F S3 TS P ϑ T6A S 1ph ~ 5Hz 23V PS R3 T1 T P ϑ I T2 P1 P2 T6 T7 T8 3 V21 V11 S1 TR ϑ P VR M PT1 PT3 PT5 VS DC+ DC GD D1 PE MB Burner terminal board TS Safety thermostat S External lockout signal S1 External lockout signal on the seal control I Manual switch T Threshold thermostat TR High/low flame setting thermostat T6A 6A fuse F Fuse (see table A) ead section (see table A) PG Minimum gas pressure switch PS ockout reset button VR Adjustment valve VS Safety valve VPS Seal control T8 T7 T6 B5 PE VPS PG P The following table shows the supply lead sections and the type of fuse to be used. Model F A mm 2 RS 68/M MX 23V T16 2,5 4V T 1,5 RS 12/M MX 23V T16 2,5 4V T 1,5 RS 16/M MX 23V T25 2,5 4V T2 2,5 Table A 12
13 MODUATIG OPERATIO temperature probe MB RS/M MX a b c d BT Q13 Q14 1 M1 G1+ I1 U1 G+ G Q Y1 Y2 GD D1 TE RWF 4 MB Burner auxiliary terminal board S External lockout signal I Manual switch BT Temperature probe F Fuse (see table A) ead section (see table A) RWF4 Regulator (installed on the burner) MODUATIG OPERATIO pressure probe MB RS/M MX T2 T1 M PT1 PT3 PT5 DC+ DC T6 T8 T7 GD D1 PE T2 T1 M PT1 PT3 PT5 DC+ DC T6 T8 T7 GD D1 PE 1 2 PE 4/2mA PE BP Q13 Q14 1 M1 G1+ I1 U1 G+ RWF 4 G Q Y1 Y2 GD D1 TE MB Burner auxiliary terminal board S External lockout signal I Manual switch BP Pressure probe F Fuse (see table A) ead section (see table A) RWF4 Regulator (installed on the burner) 13
14 EMISSIOS The emission data has been measured at maximum output, according to E 676 and E 267 standard. The Ox emissions of RS/M MX burners are conforming to class 3 of E 676 (gas) and Class 2 of E 267 (oil). mg/kwh 25 2 Ox EMISSIOS mg/kwh 25 2 CO EMISSIOS db(a) 8 OISE EMISSIOS RS/M MX RS/M MX RS/M MX Gas working ight oil working Combustion head operating diagram of RS/M MX model In the RS/M MX burners part of the gas is distributed through outlets which are perpendicular to the air flow, while the remaining gas is injected directly into the centre of the flame. This prevents no homogeneous concentrations in the flame with areas of high oxidation, producing very stable flame with gradual and progressive combustion as the flame develops, thus giving polluting emission values below even the most restrictive norm values. 14
15 OVERA DIMESIOS (mm) BURER B A C O O(1) E F F(1) H D V I M Model A B C D E F F (1) H I M O O (1) V RS 68/M MX RS 12/M MX RS 16/M MX Rp (1) ength with extended combustion head. BURER BOIER MOUTIG FAGE P Q R Model RS 6812/M MX RS 16/M MX P Q R M12 M16 PACKAGIG Z X Y Model X X(1) Y Z kg RS 68/M MX RS 12/M MX RS 16/M MX (1) ength with extended combustion head. 15
16 ISTAATIO DESCRIPTIO Installation, start up and maintenance must be carried out by qualified and skilled personnel. All operations must be performed in accordance with the technical handbook supplied with the burner. BURER SETTIG All the burners have slide bars, for easier installation and maintenance. After drilling the boilerplate, using the supplied gasket as a template, dismantle the blast tube from the burner and fix it to the boiler. Adjust the combustion head. Fit the gas train choosing this on the basis of the maximum boiler output and following the diagrams included in the burner instruction handbook. Refit the burner casing to the slide bars. Install the nozzle choosing this on the basis of the maximum boiler output and following the diagrams included in the burner instruction handbook. Check the position of the electrodes. Close the burner, sliding it up to the flange, keeping it slightly raised to avoid the flame stability disk rubbing against the blast tube. EECTRICA AD HYDRAUIC COECTIOS AD START UP The burners are supplied for connection to two pipes fuel supply system. Connect the ends of the flexible pipes to the suction and return pipework using the supplied nipples. Make the electrical connections to the burner following the wiring diagrams included in the instruction handbook. Prime the pump by turning the motor (after checking rotation direction if it is a three phase motor). Adjust the gas train for first start. On start up, check: Pressure pump and valve unit regulator (to max. and min.) Gas pressure at the combustion head (to max. and min. output) Combustion quality, in terms of unburned substances and excess air. 16
17 BURER ACCESSORIES ozzles The nozzles must be ordered separately. The following table shows the features and codes on the basis of the maximum required fuel output. ozzles type 6 B Burner Rated delivery kg/h (*) GPH ozzle code 21,2 5, ,3 5, ,5 6, ,6 6, RS 6812/M MX 29,7 7, ,8 7, ,9 8, ,1 8, ,2 9, ,3 9, ,4, ,7 11, ,9 12, ,1 13, ,4 14, ,6 15, RS/M MX 67,9 16, ,1 17, ,4 18, ,6 19, ,8 2, ,3 22, ,8 24, RS 16/M MX (*) ozzle rated delivery is reffered to atomized pressure 1,3 26, ,8 28,
18 Spacer kit If burner head penetration into the combustion chamber needs reducing, varying thickness spacers are available, as given in the following table: Spacer kit Burner Spacer thickness S (mm) Kit code RS/M MX S Continuous ventilation kit If the burner requires continuous ventilation in the stages without flame, a special kit is available as given in the following table: Continuous ventilation kit Burner Kit code RS/M MX 394 Accessories for modulating operation To obtain modulating operation, the RS 16/M MX series of burners requires a regulator with three point outlet controls. The following table lists the accessories for modulating operation with their application range. Burner RS/M MX Regulator type RWF 4 Regulator code 3212 The relative temperature or pressure probes fitted to the regulator must be chosen on the basis of the application. Probe type Temperature PT Pressure 4 2 ma Pressure 4 2 ma Range ( C) (bar) 5 C 2,5 bar 16 bar Probe code
19 Depending on the servomotor fitted to the burner, a threepole potentiometer ( Ω) can be installed to check the position of the servomotor. The KITS available for the various burners are listed below. Burner RS/M MX Kit code 321 Sound proofing box If noise emission needs reducing even further, soundproofing boxes are available, as given in the following table: Burner RS 6812/M MX RS 16M/MX Sound proofing box Box type C3 C4 Box code GAS TRAI ACCESSORIES Adapters When the diameter of the gas train is different from the set diameter of the burners, an adapter must be fitted between the gas train and the burner. The following table lists the adapters for various burners. Adapters Burner Gas train Dimensions Adapter code RS 12/M MX RS 16/M MX MBC 19 SE 65 FC (CT*) D 65 2"1/2 1" 1/2 2" 3825 RS 16/M MX MBC 3 SE 8 FC (CT*) D 8 2"1/2 2" 3826 * with and without seal control 19
20 Seal control kit To test the valve seals on the gas train, a special seal control kit is available. The valve seal control device is compulsory (E 676) on gas trains to burners with a maximum output over 12 kw. The seal control is type VPS 54. Burner RS/M MX Seal control kit Gas train MBD 42 MBC 12 SE 5 MBC 19 SE 65 FC MBC 3 SE 8 FC Kit code 3367 Stabiliser spring Accessory springs are available to vary the pressure range of the gas train stabilisers. The following table shows these accessories with their application range. Stabiliser springs Gas train MBC 19 SE 65 FC (CT)* MBC 3 SE 8 FC (CT)* * with and without seal control Spring White from 4 to 2 mbar Red from 2 to 4 mbar Black from 4 to 8 mbar Green from 8 to 15 mbar Code Please refer to the technical manual for the correct choice of spring. 2
21 SPECIFICATIO A specific index guides your choice of burner from the various models available in the RS/M MX series. Below is a clear and detailed specification description of the product. DESIGATIO OF SERIES Series : R Fuel : S atural Gas ight oil S ight oil/atural Gas Heavy oil Size Setting : /1 Single stage /E Electronic cam... Two stage /P Proportioning air/gas valve /M Modulating /EV Electronic cam predisposed for variable speed (with inverter) Emission :... Class 1 E267 E676 MZ Class 2 E267 E676 BU Class 3 E267 E676 MX Class 2 E267 Class 3 E676 Head : TC Standard head T Extended head Diagnostic : P ed panel ST Status panel Flame control system : FS1 Standard (1 stop every 24 h) FS2 Continuous working (1 stop every 72 h) Electrical supply to the system : 1/23/5 1/23V/5Hz 3/23/5 3/23V/5Hz 3/4/5 3/4V/5Hz 3/234/5 3/23V/5Hz 3/4V/5Hz 3/22/6 3/22V/6Hz 3/38/6 3/38V/6Hz 3/2238/6 3/22/6Hz 3/38V/6Hz Auxiliary voltage : 23/56 23V/56Hz 1/56 1V/56Hz ID: Differential switch R S 16 /M MX TC FS1 3/234/5 23/5 BASIC DESIGATIO EXTEDED DESIGATIO AVAIABE BURER MODES RS 68/M MX TC FS1 3/234/5 23/5 RS 68/M MX T FS1 3/234/5 23/5 RS 68/M MX TC FS2 3/234/5 23/5 RS 68/M MX T FS2 3/234/5 23/5 RS 12/M MX TC FS1 3/234/5 23/5 RS 12/M MX T FS1 3/234/5 23/5 RS 12/M MX TC FS2 3/234/5 23/5 RS 12/M MX T FS2 3/234/5 23/5 RS 16/M MX TC FS1 3/234/5 23/5 RS 16/M MX T FS1 3/234/5 23/5 Other versions are available on request. 21
22 PRODUCT SPECIFICATIO Burner: Monoblock forced draught OW Ox dual fuel burner with two stage operation at the oil side and two stage progressive or modulating operation at the gas side, with a specific kit, fully automatic, made up of: air suction circuit lined with soundproofing material centrifugal fan with high performance and low sound emissions air damper for air flow setting and butterfly valve for regulating gas output controlled by a servomotor with variable cam starting motor at 28 rpm, threephase 4V with neutral, 5Hz low emission combustion head, that can be set on the basis of required output, fitted with: stainless steel end cone, resistant to corrosion and high temperatures ignition electrodes gas distributor flame stability disk maximum gas pressure switch to stop the burner in the case of excess pressure on the fuel supply line minimum air pressure switch stops the burner in case of insufficient air quantity at the combustion head gears pump for high pressure fuel supply pump starting motor oil safety valves two oil valves (1st and 2nd stage) flame control panel UV photocell for flame detection burner on/off selection switch manual or automatic output increase/decrease selection switch Oil/Gas selector flame inspection window slide bars for easier installation and maintenance protection filter against radio interference IP 44 electric protection level. Gas train: Fuel supply line, 2 configuration: MUTIBOC with integrated filter minimum gas pressure switch. Fuel supply line D 65 e D8 configuration: filter MUTIBOC minimum gas pressure switch. Conforming to: 89/336/EEC directive (electromagnetic compatibility) 73/23/EEC directive (low voltage) 92/42/EEC directive (performance) 9/396/EEC directive (gas) 98/37/EEC directive (machinery) E 676 (gas burners) E 267 (oil burners). Standard equipment: 1 gas train gasket 1 flange gasket 4 screws for fixing the flange 1 thermal screen 4 screws for fixing the burner flange to the boiler 2 flexible pipes for connection to the oil supply network 2 nipples for connection to the pump with gaskets Instruction handbook for installation, use and maintenance Spare parts catalogue. 22
23 Available accessories to be ordered separately: ozzles Spacer kit Continuous ventilation kit RWF 4 output regulator Pressure probe 2.4 bar Pressure probe 16 bar Temperature probe 5 C Potentiometer kit for the servomotor Gas train adapter Seal control kit Stabiliser spring Sound proofing box. 23
24 ISO 91 Cert. n. 61 RIEO S.p.A. Via degli Alpini, EGAGO (VR) Italy Tel Fax Internet: [email protected] Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIEO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.
MODULATING LIGHT OIL BURNERS RL/M SERIES
MODULATING LIGHT OIL BURNERS RL/M SERIES RL 28/M 95/166 332 kw RL 38/M 11/237 45 kw RL 5/M 13/296 593 kw RL 7/M 261/474 143 kw RL 1/M 332/711 1482 kw RL 13/M 498/948 1779 kw RL 19/M 534/1423 2431 kw The
TWO STAGE GAS BURNERS
TWO STAGE GAS BURNERS GAS/2 SERIES GAS 3/2 8/13 3 kw GAS 4/2 12/18 47 kw GAS /2 1/32 66 kw GAS 6/2 3/2 1 kw 4/8 176 kw 1/17 32 kw The GAS/2 series of burners covers a firing range from 8 to 32 kw and they
ONE STAGE LIGHT OIL AND KEROSENE BURNERS
ONE STAGE LIGHT OIL AND KEROSENE BURNERS RDB SERIES RDB-R 6,8 4,6 kw RDB-R 4, 46, kw RDB.-.R, 4, kw RDB.-.R,, kw RDB,6 68,7 kw RDB. 4,, kw RDB4,7, kw The Riello RDB series of one stage light oil and kerosene
TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/41 106 kw GS20D 58/81 220 kw
TWO STAGE GAS BURNERS RIELLO 4 GSD SERIES 9/4 6 58/8 The Riello 4 GSD series of two stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 4
LOW NOx DUAL FUEL BURNERS RLS/BP MX SERIES
LOW NOx DUAL FUEL BURNERS RLS/BP MX SERIES RLS 300/BP MX 600/1250 3650 kw RLS 400/BP MX 1000/2000 4500 kw RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary
ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS3 11 35 kw FS5 23 58 kw FS8 46 93 kw FS10 42 116 kw FS20 81 220 kw
ONE STAGE GAS BURNERS RIELLO FS SERIES FS3 35 kw FS5 3 5 kw FS 93 kw FS kw FS kw The Riello FS series of one stage gas burners, is a complete range of products developed to respond to any request for light
RL Series. Technical Data Leaflet. Two Stage Light Oil Burners. Light Oil TS0035UK03
Technical Data Leaflet TS0035UK03 Light Oil RL Series Two Stage Light Oil Burners RL 34 MZ 97/154 395 kw RL 44 MZ 155/235 485 kw RL 50 148/296 593 kw RL 64 MZ 200/400 820 kw RL 70 255/474 830 kw RL 100
Oil - kerosene burners
Installation, use and maintenance instructions Oil - kerosene burners One stage operation CODE MODEL TYPE 3747469 G0 474T5 90 (0) - 05/008 TECHNICAL FEATURES Thermal power output 95 3 kw 8 8 kg/h Fuel
Oil, Gas and Dual Fuel Burners
Oil, Gas and Dual Fuel Burners Burner series 130...150 250, 280 Group 3 Capacity 390-3500 kw Table of contents General 1 How to choose a burner 2 Light oil burners Technical data and dimensions 3-4 PI-diagrams
Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften D F GB NL Öl-Gebläsebrenner Brûleur fioul Oil burner
Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander
Montage und Bedienungs Anleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften D F GB NL Öl-Gebläsebrenner Brûleur fioul Oil burner
- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW.
- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-9kW. Low NO x Comprehensive control panel Gas rack Low NOx combustion head Strong light alloy pressuremoulded housing Electronic ignition transformer
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
I D F GB E NL 3755116 GS3 551T1 3755117 GS3 551T1
Istruzioni per installazione, uso e manutenzione Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Instrucciones para la instalación, uso y mantenimiento
1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.
LOW PRESSURE OIL BURNERS CBW 50 CBW-150 OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS. CBW-50 CBW-150 40 100 kw 80 150 kw THIS TECHNICAL DOCUMENTATION
FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES
01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection
Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission
Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
Weishaupt gas burners type G Gas/oil dual fuel burners types GL and RGL Sizes 1 and 3 1/2000 GB
Weishaupt gas burners type G Gas/oil dual fuel burners types GL and RGL Sizes 1 and 3 1/2000 GB Description Weishaupt G, GL and RGL gas and dual fuel burners satisfy the requirements for operational safety,
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Aludesign K A T A L O G
Aludesign K A T A L O G plynové radiátory DESIGN The result of lengthy experience and technological research, GAZELLE TECHNO today is a universally recognised gas radiator*. It has been completely re-designed
Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
Automatic control equipment for HVAC systems
Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
Condensate water pump with neutralisation system
Pumps for fuel oil and gas boiler Condensate water pump with neutralisation system SK9E/FP8E débit obtenu (l/h) caractéristriques selon la fréquence réglée performances avec une hauteur d aspiration de
SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2
SERVICE COMPACT SERVICE 000 MANUAL Mod. 000 9X Mod. 000 9X Mod. 000 94X Part Forward This Service Handbook is intended to assist with servicing and fault-finding in Caravans and Motor Caravans equipped
OPERATING AND MAINTENANCE INSTRUCTIONS LIGHT OIL BURNERS
OPERATING AND MAINTENANCE INSTRUCTIONS LIGHT OIL BURNERS ❹ KP-6 ❹ KP-6 L ❹ KP-6 LH ❹ KP-6-2 ❹ KP-6 H-2 OILON OY P.O.Box 5 FIN-15801 LAHTI FINLAND +358-3-85 761 Fax +358-3-857 6239 E-mail [email protected]
TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
DUAL FUEL BURNERS GAS/HEAVY OIL
M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Product Overview Benefits
Trade Data CP CP Upright / CP Horizontal / CP Counterflow / CP EA External Heaters and Fired Warm Air Heaters Heat Outputs from 26kW - 586kW Issue 1.02 Print 2 ay 2011 Product Overview Benefits Installer
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.
SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
United Kingdom en. ErP information. Gas fired condensing boiler Gas 210 ECO PRO
United Kingdom en ErP information Gas fired condensing boiler Gas 210 ECO PRO Dear customer, Thank you for purchasing this appliance. Please read this manual carefully before using the product and keep
LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34
LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
OilonChooser Operating Instructions
OilonChooser Operating Instructions 1. Menu display and structure OilonChooser s menu display shows the data input field in the central area. The navigation bar is located in the left column. It shows
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district
PLANT TORINO NORD Iren Energia is the company in the Iren Group whose core businesses are the production and distribution of electricity, the production and distribution of thermal energy for district
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Diesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS
MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS Measuring and Controlling Equipment ensuring required water quality in public pools. This is fully automatic measuring and controlling equipment with
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)
REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED) MODELS 0, 80, 00, 20 PARTS LIST AUGUST 202 A REDFYRE CENTRAL HEATING COOKER ---- TOP - PLATE & LIDS 2 REDFYRE CENTRAL HEATING COOKER ---- TOP - PLATE &
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
BIOHOUSING Seminar Success stories of biomass heating in small scale
BIOHOUSING Seminar Success stories of biomass heating in small scale Pellet stove: attractive and fully automatic central heating systems Lorenzo Corbella 28th October 2008 House of Cities, Municipalities
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
Öl-Gebläsebrenner Brûleur fioul domestique Light oil burner Stookoliebrander Quemadores de gasóleo Καυστήρας Πετρελαίου
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Instrucciones de instalación, uso y mantenimiento Οδηγίες
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners
A Honeywell Company Gas Burner Safety Control For 2-stage forced draught and combi oil/gas burners Possible flame detectors: - Ionisation probe - Infrared flicker detector 1020 - UV flame sensor UVD 971
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
ECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
High efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
Designed for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
Heating with wood chips and pellets
YOUR RELIABLE PARTNER Heating with wood chips and pellets Present on the market 110 for over years 90-150 Advantages of the HERZ firematic boiler User friendly with: Easy operation Automatic cleaning system
- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013
Sid/Page 1 SESOBS THE SMOKE DENSITY MONITOR - Easy and safe to operate and install - Complete with sealing air fans. - Remote smoke density indication possible. - Designed to meet with the environmental
Kerosene and Gas oil burner
Installation, use and maintenance instructions Kerosene and Gas oil burner One stage operation CODE MODEL TYPE 20030780 G3B 437T50 (2) - 03/2012 Original instructions Contents 1 Declaration... 3 2 Information
www.optimumheat.co.uk
The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Wall boiler spare parts
SAUNIER Disconnector see page.14 Wall boiler spare parts Saunier Duval/ Chaffoteaux/MTS/ ELM > CHAFFOTEAUX Printed Circuit see page.39 SD Substituted spare parts Saunier Duval Description New ref Old ref
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM
SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM Volumetric SYSTEM 1 Ph +39 0331 601697 Fax +39 0331 365149 - www.ilclube.com - [email protected] VOLUMETRIC SYSTEM INDEX INTRODUCTION 4-5 MANUAL PUMPS PRD-13 6-7
226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) 80 90 : 3 CxHy CO2 H2O. CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () CO ( ).
226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) I 80 90 1 / / 1 (C) ( 2 ) CO 2 2 21 % 79 % 3 CxHy CO2 H2O CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () 4 CO2 ( ) 5 CO2 ( ) CO ( ) 6 1atm 100C 7 8 ( ) 9 10 11 12
Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control