AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)
|
|
|
- Rudolph Griffin
- 9 years ago
- Views:
Transcription
1 AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)
2 AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)
3 CONTENTS Part 1. Introduction Part 2. Indoor Unit(Hydro kit) Part 3. Outdoor Unit Part 4. Accessories
4 Guide Revision History Pub. No. Frequency Type Product name Refrigerant Models Notes Published in 5BPU0-01A 50Hz Air to Water Heat Pump Therma V R410A AHUW096A1 (HU091 U41) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) New edition of EPDB (Preliminary Version) July BPU0-02A 50Hz Air to Water Heat Pump Therma V R410A AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) Added outdoor unit model April BPU0-03A 50Hz Air to Water Heat Pump Therma V R410A AHNW09606A1(HN0916 NK1) AHNW09A06A1(HN0926 NK1) AHNW09806A1(HN0936 NK1) Added indoor unit model June Air-to-Water Heat Pump _ 3
5 Part 1. Introduction 1. System Configuration 2. System Layout 3. Features 4. Advantages & Benefits 5. System Application Schematic Examples
6 1. System Configuration LG Supply Indoor Unit(Hydro kit) Outdoor Unit Introduction Radiator or Sanitary tank(only) or Sanitary tank + Solar heat source Fan coil unit Under floor pipe Field supply Refer to the installation manual regarding various applications in detail Air-to-Water Heat Pump _ 1
7 2. System Layout Introduction Outdoor Unit Refrigerant (R410A) Indoor Unit (Hydro kit) Water 9kW Hydro kit 12/14/16kW Heat exchange between Refrigerant and Water Internal electric heater Boiler can be interlocked Sanitary water tank (+ Solar heat source) Floor Heating Radiator or Fan coil unit Sanitary water tank Solar heat source Under floor pipe Radiator Fan coil unit Refer to the installation manual regarding various applications in detail 2 _ Air-to-Water Heat Pump
8 3. Advantages & Benefits Central Control Introduction Air-to-Water Heat Pump VRF System Heat recovery Ventilation system Air-to-Water Heat Pump _ 3
9 3. Advantages & Benefits Emergency Control Easy checking of system failure Introduction Slight trouble Heavy trouble - Slight / Heavy trouble Emergency operating - Heavy trouble - Electric heater ON - Secure at least heating before A/S Easy Setting Feature Water Inlet temp. Water Outlet temp. Water Tank temp. Space temp. Solar Heating temp. Indoor temp. or Water temp. (Optional temp. setting) 4 _ Air-to-Water Heat Pump
10 3. Advantages & Benefits Controller Configuration 1 Display Panel Change Temperature Button Silent Mode On / Off Button Mode Selection Button Water Heating Enable / Disable Button ESC Button Introduction Direction Button (Up, Down, Left, Right) Power Button Function Setting Button Temperature Setting Mode Button Temperature View Mode Button Programming Button Set / Clear button Display Panel Cooling Heating Weather-dependent Heating Space Temp. Water Inlet Temp. Water Outlet Temp. Central Controller Thermostat Electric Heater (1) Electric Heater (2) Water Tank Electric Heater Water Pump Solar Heating Pump Water Tank Heating Enable / Disable Water Tank Heating (by Heat Pump) Silent Mode ON / OFF Water Tank Temp. Solar Heating Temp. Defrost Water-Pipe Anti-Freezing Water Tank Disinfection Outdoor Unit Child Lock Not Available Function Slight Trouble Heavy Trouble Air-to-Water Heat Pump _ 5
11 3. Advantages & Benefits Introduction 3.1 More Ecological Background for EU regulations... A. To preserve, protect and improve the quality of the environment, protect human health and utilise natural resources prudently and rationally B. Basic principle = preventive action, environmental damage should be rectified at source and the polluter should pay C. If waste cannot be avoided, it should be reused or recovered for its material or energy. LGE Environmental Policy ; LG Electronics has finalized the development strategy with the following goals to develop eco-friendly products to meet a range of environmental challenges and secure Advanced production technology 3 key Eco-design strategies LGE RoHS management ; Declared eliminating the six hazardous substances specified in the EUʼs RoHS Directive (Pb, Cd, Cr6+, HG, PBBs, PBDEs) from all LGEʼs products in July * RoHS : Restriction of Hazardous Substances LGE ECO-friendly Activity ; We are operating a special lab for analyzing Hazardous substance. - Fully equipped with precision analysis instruments such as ICP, IC, GC-MS, FR-IR - Developed and standardized methods to analyze and test hazardous substance - Certified as an official lab by the UL (Underwriters Laboratories) in February 2005, and by TÜV Rheinland in May Participating in the assessment done by external organizations - Enhancing the reliability of internal analysis through regular assessment of skills, education, workshops and six sigma activities 6 _ Air-to-Water Heat Pump
12 4. System Application Schematic Examples 4.1 Connecting Heat Emitters for Heating and Cooling (Under floor loop, Fan Coil Unit, and Radiator) Outdoor Unit Outdoor Indoor Indoor Unit Introduction NOTE Fan coil unit Floor heating loop Radiator Room thermostat - Type of thermostat and specification should be complied with chapter 4 and chapter 7 of THERMA V installation manual. 2way control valve - It is important to install 2way control valve to prevent dew condensation on the floor and radiator while cooling mode. - Type of 2way control valve and specification should be complied with chapter 4 and chapter 7 of THERMA V installation manual. - 2way valve should be installed at the supply side of the collector. By-pass valve - To secure enough water flow rate, by-pass valve should be installed at the collector. - By-pass valve should guarantee minimum water flow rate in any case. Minimum water flow rate is described in water pump characteristics curve. High Temperature Low Temperature Shut-off valve Room Thermostat(Field supply) 2way control valve(field supply) By-pass valve(field supply) CAUTION If is installed with pre-existing boiler, the boiler and should not be operated together. If entering water temperature of is above 55 C, the system will stop operation to prevent mechanical damage of the product. For detailed electric wiring and water piping, please contact authorized installer. Some installation scenes are presented for example. As these scenes are conceptual figures, installer should optimize the installation scene according to the installation conditions. Air-to-Water Heat Pump _ 7
13 4. System Application Schematic Examples 4.2 Connecting Sanitary Water Tank Introduction Outdoor Unit Outdoor Indoor Indoor Unit Fan coil unit Floor heating loop Radiator Hot water City water Sanitary water tank NOTE Sanitary water tank - It should be equipped with internal electric heater to generate sufficient heat energy in very cold season. 3way control valve - Type of 3way control valve and specification should be complied with chapter 4 and chapter 7 of installation manual. High Temperature Low Temperature Shut-off valve Room Thermostat(Field supply) 2way control valve(field supply) By-pass valve(field supply) 3way control valve (Field supply) CAUTION If is installed with pre-existing boiler, the boiler and should not be operated together. If entering water temperature of is above 55 C, the system will stop operation to prevent mechanical damage of the product. For detailed electric wiring and water piping, please contact authorized installer. Some installation scenes are presented for example. As these scenes are conceptual figures, installer should optimize the installation scene according to the installation conditions. 8 _ Air-to-Water Heat Pump
14 4. System Application Schematic Examples 4.3 Connecting Solar thermal system Outdoor Unit Outdoor Indoor Indoor Unit Introduction Solar heat source Fan coil unit Floor heating loop Radiator Hot water Sanitary water tank City water NOTE Sanitary water tank - It should have additional indirect heat exchanger to utilize heat energy by solar thermal system. Pump - Maximum power consumption of pump should be less than 0.25kW. High Temperature Low Temperature Shut-off valve Room Thermostat(Field supply) 2way control valve (Field supply) By-pass valve(field supply) 3way control valve (Field supply) Pump(Field supply) CAUTION If is installed with pre-existing boiler, the boiler and should not be operated together. If entering water temperature of is above 55 C, the system will stop operation to prevent mechanical damage of the product. For detailed electric wiring and water piping, please contact authorized installer. Some installation scenes are presented for example. As these scenes are conceptual figures, installer should optimize the installation scene according to the installation conditions. Air-to-Water Heat Pump _ 9
15 Part 2. Indoor Unit (Hydro kit) 1. Nomenclature 2. Model Line-up 3. List of Functions 4. Specifications 5. Dimensions 6. Wiring Diagrams 7. External Wiring Diagrams 8. Piping Diagrams 9. Pump Hydraulic Performance
16 1. Nomenclature 1.1 Global Model Name AH N W 16 A 06 A 1 Serial Number Chassis Name Heater Capacity (kw) Ex) 06 : 6kW Class Heater Electrical Ratings 6 : 1 phase V 50Hz 8 : 3 phase V 50Hz A : 3 phase 220V 50Hz Heating Capacity (kw) Ex) 16 : 16kW Class 1.2 Europe Model Name Model Type W : DC Inverter Heat Pump H : Heat Pump Classification N : Indoor Unit U : Outdoor Unit - : Set Air-to-Water Heat Pump for R410A Indoor Unit H N Heater Capacity (kw) Ex) 04 : 4kW Class 06 : 6kW Class 09 : 9kW Class Electrical Ratings 1 : 1 Phase V 50Hz 2 : 3 Phase 220V 50Hz 3 : 3 Phase V 50Hz Classification 09 (Combined with 09kW of Outdoor Unit) 16 (Combined with 12/14/16kW of Outdoor Unit) N : Hydro kit (Indoor Unit) H : Air to Water Heat Pump Air-to-Water Heat Pump _ 1
17 2. Model Line-up 2.1 Hydrokit Indoor Unit Model Name AHNW09604A1 (HN0914 NK1) AHNW09606A1 (HN0916 NK1) AHNW09A06A1 (HN0926 NK1) AHNW09806A1 (HN0936 NK1) AHNW16606A1 (HN1616 NK1) AHNW16A06A1 (HN1626 NK1) AHNW16806A1 (HN1636 NK1) AHNW16A09A1 (HN1629 NK1) AHNW16809A1 (HN1639 NK1) Electric Heater Capacity(kW) Power Source (Electric Heater) 4(2+2) 1Ø, V, 50Hz 6(3+3) 6(2+2+2) 1Ø, V, 50Hz 3Ø,220V, 50Hz 3Ø, V, 50Hz 6(3+3) 1Ø, V, 50Hz 6(2+2+2) 9(3+3+3) 3Ø, 220V, 50Hz 3Ø, V, 50Hz 3Ø, 220V, 50Hz 3Ø, V, 50Hz 2.2 Outdoor Unit Model Name AHUW096A1 (HU091 U41) AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) Capacity Cooling (kw) Heating (kw) Power Source 1Φ, V, 50Hz 3Φ, V, 50Hz 2 _ Air-to-Water Heat Pump
18 3. List of Functions Category Installation Reliability Convenience Individual control CAC network function Special function kit Others AWHP Function Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller(control panel) Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control General central controller (Non LGAP) Dry contact Network Soluation(LGAP) PDI(power distribution indicator) PI 485 Zone control CTIE Electro thermostat Remote room temperature sensor (TH8) Anti-Condensation on floor (cooling) Water Pump ON / OFF Control Flow Switch Control Thermostat Interface (230V AC) Thermostat Interface (24V AC) Sanitary Tank Heating Solar-Thermal Interface with Sanitary Tank PHEX Anti-Freezing Control Water Pump Forced Operation Autosetting according to Ambient Temperature Silent Operation Anti-overheating of Water Pipe Emergency Operation AHNW166**A1 (HN161* NK1) AHNW168**A1 (HN163* NK1) AHNW16A**A1 (HN162* NK1) PQDSA PQDSA PQDSA PQRSTA0 PQRSTA0 PQRSTA0 Indoor Unit Notes O : Applied, X : Not applied, : No relation * TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)' * Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Air-to-Water Heat Pump _ 3
19 3. List of Functions Indoor Unit Category Installation Reliability Convenience Individual control CAC network function Special function kit Others AWHP Function Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller(control panel) Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control General central controller (Non LGAP) Dry contact Network Soluation(LGAP) PDI(power distribution indicator) PI 485 Zone control CTIE Electro thermostat Remote room temperature sensor (TH8) Anti-Condensation on floor (cooling) Water Pump ON / OFF Control Flow Switch Control Thermostat Interface (230V AC) Thermostat Interface (24V AC) Sanitary Tank Heating Solar-Thermal Interface with Sanitary Tank PHEX Anti-Freezing Control Water Pump Forced Operation Autosetting according to Ambient Temperature Silent Operation Anti-overheating of Water Pipe Emergency Operation AHNW09604A1 (HN0914 NK1) AHNW09606A1 (HN0916 NK1) AHNW09A06A1 (HN0926 NK1) AHNW09806A1 (HN0936 NK1) O O O O O O O PQDSA PQDSA PQDSA PQDSA O PQRSTA0 PQRSTA0 PQRSTA0 PQRSTA0 O O O O O O O O O O O O O Notes O : Applied, X : Not applied, : No relation * TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)' * Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. 4 _ Air-to-Water Heat Pump
20 4. Specifications Indoor Units Nominal Power Input W Nominal Running Current without Electric Heater A Operation Range Cooling(Fan coil unit) C (Min.~Max.) Cooling(Under floor) C Leaving Water Heating(Fan coil unit or Radiator) C Temperature Heating(Under floor) C Pump Type - Steps of Speed EA Power Input W Water Flowrate Limit LPM Heat Exchanger Type - Number of Plate EA Quantity EA Expansion Vessel Volume liter Water Pressure(Max.) bar Water Pressure(Pre) bar Strainer Mesh Size mm Material - Electric Heater Type - Number of Heating Coil EA Capacity Combination kw Operation - Heating Steps Step Power Supply Ø / V / Hz Rated Current A Maximum Current(MCA) A Water Circuit Safety Valve bar Entering Side Diameter inch Leaving Side Diameter inch Manometer - Drain Valve / Fill Valve - Shut Off Valve - Air Vent - Refrigerant Circuit Gas Side Diameter mm(inch) Liquid Side Diameter mm(inch) Dimensions Unit(H x W x D) mm Packed Unit(H x W x D) mm Weight Unit kg (Without water) Packed Unit kg Sanitary Water Tank Type - Heater Capacity kw Power Supply Ø / V / Hz Power Supply Type - Thermal Protector Range C Relay Contactor - ELB A Sensor Adaptor Diameter mm(inch) Accessory Kit - AHNW166**A1 (HN161* NK1) AHNW168**A1 (HN163* NK1) AHNW16A**A1 (HN162* NK1) ~ 30 6 ~ 30 6 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 55 Canned type for hot water circulation 2 (In Max. / Med. / Min., Min. step is not used) At least 15.0 At least 15.0 At least 15.0 Brazed Plate HEX Brazed Plate HEX Brazed Plate HEX x 1 1 x 1 1 x 1 Stainless Steel Stainless Steel Stainless Steel Sheath Sheath Sheath or 9 6 or 9 Automatic Automatic Automatic / / 50 3 / / 50 3 / 220 / Male PT 1 Male PT 1 Male PT 1 Male PT 1 Male PT 1 Male PT (5/8) (5/8) (5/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 850 x 490 x x 490 x x 490 x x 563 x x 563 x x 563 x Indirect heating(+ Electric heater) Max. 3 1 / 230 / 50 Separated power source Max. 90 Needed (1/2) LG Supply(model : PHLTA) Indoor Unit Note : 1. The specification may be subject to change without prior notice for purpose of improvement. Air-to-Water Heat Pump _ 5
21 4. Specifications Indoor Unit Indoor Units Nominal Power Input W Nominal Running Current without Electric Heater A Operation Range Cooling(Fan coil unit) C (Min.~Max.) Cooling(Under floor) C Leaving Water Heating(Fan coil unit or Radiator) C Temperature Heating(Under floor) C Pump Type - Steps of Speed EA Power Input W Water Flowrate Limit LPM Heat Exchanger Type - Number of Plate EA Quantity EA Expansion Vessel Volume liter Water Pressure(Max.) bar Water Pressure(Pre) bar Strainer Mesh Size mm Material - Electric Heater Type - Number of Heating Coil EA Capacity Combination kw Heating Steps Step Power Supply Ø / V / Hz Maximum Current(MCA) A Water Circuit Safety Valve bar Entering Side Diameter inch Leaving Side Diameter inch Manometer - Drain Valve / Fill Valve - Shut Off Valve - Air Vent - Refrigerant Circuit Gas Side Diameter mm(inch) Liquid Side Diameter mm(inch) Dimensions Unit(H x W x D) mm Packed Unit(H x W x D) mm Weight Unit kg (Without water) Packed Unit kg Sanitary Water Tank Type - Heater Capacity kw Power Supply Ø / V / Hz Power Supply Type - Thermal Protector Range C Relay Contactor - ELB A Sensor Adaptor Diameter mm(inch) Accessory Kit - MCCB A AHNW09604A1 (HN0914 NK1) AHNW09606A1 (HN0916 NK1) AHNW09A06A1 (HN0926 NK1) AHNW09806A1 (HN0936 NK1) ~30 16~30 15~55 15~55 Canned type for hot water circulation 2 (In Max. / Med. / Min., Min. step is not used) 135 At least 15 LPM Blazed Plate HEX x 1 Stainless Steel Sheath Sheath Sheath Sheath / / 50 1 / / 50 3 / 220 / 50 3 / / Male PT 1 Male PT 1 O O O O (5/8) 9.52 (3/8) 850 x 490 x 315 1,032 x 563 x Indirect heating (+ Electric heater) Max. 3 1/ 230 / 50 Separated power source Max. 90 Needed (1/2) LG Supply 32 Note : 1. The specification may be subject to change without prior notice for purpose of improvement. 6 _ Air-to-Water Heat Pump
22 5. Dimensions 5.1 Internal [Unit:mm] AWHP AHNW09***A1 (HN09** NK1) AHNW16***A1 (HN16** NK1) No Name Remarks 1 Refrigerant Pipe Ø15.88mm 2 Refrigerant Pipe Ø9.52mm 3 Entering Water Pipe Male PT 1 inch 4 Leaving Water Pipe Male PT 1 inch 5 Control Panel Built-in Remote Controller 6 Water Pump Max Head 7.5 / 6.5 meter 7 Safety Valve Open at water pressure 3 bar 8 8' Thermal switch Thermal switch Cut-off power input to electric heater at 90 centigrade (manual return at 55 centigrade) 9 Control Box PCB and terminal blocks 10 Flow Switch Minimum operation range at 12 LPM 11 Plate Heat Exchanger Heat exchange between refrigerant and water 12 Pressure Gage Indicates circulating water pressure 13 Expansion Tank Absorbing Volume change of heated water 14 Air Vent Air purging when Charging water 15 Electric Heater Additional heating source 16 Strainer 17 Shut-off valve 18 Carrying handle Cut-off power input to electric heater at 90(primary) and 200(secondary) centigrade (auto return at 70 centigrade for first thermal switch) Filtering and stacking particles inside circulating water When connecting water pipes,drain water or block the flow from indoor unit To carry the product Notice : Item 8 and Item 8 will be applied exclusively Note 1. Unit should be installed in compliance with the installation manual in the product box. 2. Unit should be grounded in accordance with the local regulations or applicable national codes. 3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes. 4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter. Hydro kit Indoor Unit Air-to-Water Heat Pump _ 7
23 5. Dimensions 5.2 External [Unit:mm] Indoor Unit AWHP AHNW09***A1 (HN09** NK1) AHNW16***A1 (HN16** NK1) No Name Remarks 1 Door Control panel is shown after this door is opened. 2 Handle Used to cover or uncover the front case Note 1. Unit should be installed in compliance with the installation manual in the product box. 2. Unit should be grounded in accordance with the local regulations or applicable national codes. 3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes. 4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter. Hydro kit 8 _ Air-to-Water Heat Pump
24 6. Wiring Diagrams AHNW**6**A1 (HN**1* NK1) Indoor Unit Air-to-Water Heat Pump _ 9
25 6. Wiring Diagrams AHNW**A**A1 (HN**2* NK1) AHNW**8**A1 (HN**3* NK1) Indoor Unit 10 _ Air-to-Water Heat Pump
26 7. External Wiring Diagrams AHNW**6**A1 (HN**1* NK1) Indoor Unit Air-to-Water Heat Pump _ 11
27 7. External Wiring Diagrams AHNW**A**A1 (HN**2* NK1) AHNW**8**A1 (HN**3* NK1) 1~ 230V 50Hz M/C 3 MCCB M/C Indoor Unit 3~ 220V 50Hz MCCB M/C 12 _ Air-to-Water Heat Pump
28 8. Piping Diagrams AHNW*****A1 (HN**** NK1) Sanitary water tan k is installed (Sanitary water tan k kit is necessary) Solar thermal syst em is connected (Solar thermal kit i s necessary) Indoor Unit Basic installation (IDU + ODU) Underfloor Heating Radiator Fan Coil Unit Solar Thermal Componets Air-to-Water Heat Pump _ 13
29 8. Piping Diagrams Indoor Unit Category Symbol Meaning PCB Connector Remarks TH1 TH2 TH3 Refrigerant temperature sensor (Gas side) Refrigerant temperature sensor (Liquid side) Entering Water temperature sensor CN_PIPE/OUT CN_PIPE TH4 TH5 Interim Water temperature sensor Leaving Water temperature sensor CN_TH3 F/S Flow Switch CN_FLOW1 Indoor Unit Water Heating Solar Heating E/HT W_PUMP1 EXP/TANK TH8 CTR/PNL 2WAY V/V_1 W/TANK B/HT 3WAY V/V_1 CITY WATER SHOWER TH6 TH7 3WAY V/V_2 W_PUMP/2 SOLAR THER- MAL SYSTEM Electric Heater Internal Water Pump Expansion Tank Remote Air temperature sensor Control Panel (or Remote Controller ) To control water flow for Fan Coil Unit Sanitary Water Tank Electric Heater - Flow control for water which is leaving from indoor unit. - Flow direction switching between underfloor and water tank Water to be heated by Indoor unit and B/HT of W/TANK Water supplied to end-user W/TANK water temperature sensor Solar-heated water temperature sensor - Flow control for water which is heated and circulated by SOLAR THERMAL SYSTEM. - Flow direction switching between SOLAR THERMAL SYSTEM and W/TANK External Water Pump - This system can include following components : Solar panel, Sensors, Thermostats, Interim heat exchanger, Water pump, etc. - To utilized hot water heated by SOLAR THERMAL SYSTEM, end-user must by LG AWHP Solar-Kit. CN_E/HEAT(A) CN_E/HEAT(B) CN_W/PUMP(A) (no connector) CN_ROOM CN_REMO CN_2WAY(A) (no connector) CN_B/HEAT(A) CN_3WAY(A) (no connector) (no connector) CN_TH4 CN_3WAY(B) CN_W/PUMP(B) (no connector) - Meaning is expressed based on Cooling mode. - TH3, TH4, and TH5 are connected at 6 pin type connector CN_TH3. - Heating capacity is divided into two level : partial capacity by E/HEAT(A) and full capacity by E/HEAT(A) + E/HEAT(B). - Operating power(230v AC 50Hz) of E/HEAT(A) and E/HEAT(B) are supplied by external power source via relay connector and ELB. - Operating power(230v AC 50Hz) of internal water pump is supplied by the connector. - Absorb volume change of heated water, - Optional accessory (sold separately) - Model : PQRSTA0 - Pre built-in at indoor unit - 3rd party accessory and Field installation (sold separately) - 2wire NO or NC type 2way valve is supported. - 3 rd party accessory and Field installation (sold separately) - Generating and storing sanitary hot water by AWHP or built-in electric heater- - 3 rd party accessory and Field installation (usually built-in at W/TANK) - Supplying additional water heating capacity. - 3 rd party accessory and Field installation (sold separately) - SPDT type 3way valve is supported. - Field installation - Field installation - TH6 and TH7 are connected at 4 pin type connector CN_TH4. - TH6 is a part of sanitary water tank kit. (model: PHLTA) - TH7 is a part of solar thermal kit (model: PHLLA) - 3 rd party accessory and Field installation (sold separately) - SPDT type 3way valve is supported. - 3 rd party accessory and Field installation (sold separately) - If water pump of SOLAR THERMAL SYSTEM is incapableof circulation,external water pump can be used. - 3 rd party accessory and Field installation (sold separately) 14 _ Air-to-Water Heat Pump
30 9. Pump Hydraulic Performance 9.1 Static Pressure Drop Model : AHNW09***A1 (HN09** NK1) Hydraulic Head Loss(mH2O) Med. 1.5 Max Water Flowrate(l/min) Indoor Unit Model : AHNW16***A1 (HN16** NK1) Hydraulic Head Loss(mH2O) H Max. : high speed setting Med. : low speed setting Max. Med Water Flowrate(l/min) Warning : Selecting a water flowrate outside the curves can cause damage to or malfunction of the unit. : Operation cutoff range Air-to-Water Heat Pump _ 15
31 Part 3. Outdoor Unit 1. Nomenclature 2. List of Functions 3. Specifications 4. Dimensions 5. Wiring Diagrams 6. Piping Diagrams 7. Performance Data 8. Capacity Correction Factor 9. Operation Range 10. Noise Criteria
32 1. Nomenclature 1.1 Global Model Name AH U W 16 8 A 1 Serial Number Chassis Name Electrical Ratings 6 : 1 phase V 50Hz 8 : 3 phase V 50Hz Nominal Heating Capacity Indication Conversion to kw Ex) "09" : 9 kw Class "12" : 12 kw Class "14" : 14 kw Class "16" : 16 kw Class Combination of Inverter Type and Cooling Only or Heat Pump W : DC Inverter Heat Pump Classification U : Outdoor Unit Air-to-Water Heat Pump for R410A 1.2 Europe Model Name H U 09 1 M Leaving Water Combination None : Low Temperature Leaving Water H : High Temperature Leaving Water M : Middle Temperature Leaving Water 1 : 1 Phase V 50Hz 3 : 3 Phase V 50Hz Nominal Heating Capacity Indication Conversion to kw Class Ex) "09" : 9 kw Class "12" : 12 kw Class "14" : 14 kw Class "16" : 16 kw Class U : Outdoor Unit Outdoor Unit H : Air to Water Heat Pump Air-to-Water Heat Pump _ 1
33 2. List of Functions Category Reliability Convenience CAC network function Function Defrost / Deicing High pressure switch Low pressure switch Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Auto operation(artificial intelligence) Auto restart operation Network soluation(lgap) PDI(Power Distribution Indicator) PI485 Special function kit Low ambient operation Others Thermistor AWHP Sanitary Tank Heating Silent Operation Emergency Operation AHUW096A1 (HU091 U41) AHUW126A1 (HU121 U31) AHUW146A1 (HU1461 U31) AHUW166A1 (HU161 U31) O O O O O O PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A O O O Outdoor Unit Category Reliability Convenience CAC network function Special function kit Others AWHP Function Defrost / Deicing High pressure switch Low pressure switch Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Auto operation(artificial intelligence) Auto restart operation Network soluation(lgap) PDI(Power Distribution Indicator) PI485 Low ambient operation Thermistor Sanitary Tank Heating Silent Operation Emergency Operation AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) PMNFP14A0 PMNFP14A0 PMNFP14A Notes O : Applied, X : Not applied, : No relation * Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. 2 _ Air-to-Water Heat Pump
34 3. Specifications Outdoor Units Power Supply Ø / V / Hz Maximum Running Cooling A Current Heating A Wiring Connections For Power Supply (Included Earth) Number of wires For Connection with Indoor Unit (Included Earth) Number of wires * Capacity Cooling(A35/W18) kw Heating(A7W35) kw * Power Input Cooling(A35/W18) kw Heating(A7W35) kw * EER Cooling(A35/W18) W/W COP Heating(A7W35) W/W Operation Range(Min.~Max.) Cooling C DB Outdoor Temperature Heating C DB Compressor Type - Model - Quantity EA Displacement cm 3 /Rev. Capacity kw Compressor Motor Type - Quantity EA Rated Output W Refrigerant Type - Charge g(oz) Control - Refrigerant Oil Type - Charged Volume cc Heat Exchanger Quantity EA Rows EA Columns EA FPI Fins/inch Fan Type - Quantity EA Air Flow Rate CMM(l/s) Fan Motor Model - Quantity EA Output W Sound Pressure Cooling db(a)±3 Level Heating db(a)±3 Liquid Piping Type - Connection Outer Diameter mm(inch) Gas Piping Type - Connection Outer Diameter mm(inch) Piping Length Minimum m (Outdoor Unit ~ Standard m Indoor Unit) Maximum m Height Difference (Outdoor Unit ~ Indoor Unit) Maximum m Additional Refrigerant Charge g/m Dimensions Unit(W x H x D) mm Packed Unit(W x H x D) mm Weight Unit kg Packed Unit kg AHUW096A1 (HU091 U41) AHUW126A1 (HU121 U31) 1 / / 50 1 / / , , ~48 5 ~ 48-20~30-20 ~ 30 Hermetic Motor Hermetic Motor GJT240DAA Note : 1. Capacities and power inputs are based on the following conditions: * : Cooling conditions - Indoor Water Temperature 23 C/18 C; Outdoor Air Temperature 35 CDB/24 CWB Heating conditions - Indoor Water Temperature 30 C/35 C; Outdoor Air Temperature 7 CDB/6 CWB Standard piping length 7.5m 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. GPT425DBA Brushless Brushless 1 1 1,700 4,000 R410A R410A 1,900(67.0) 2,850(100.5) Electronic Expansion Valve Electronic Expension Valve FVC68D FVC68D 900 1, Propeller Propeller (1,000) 60(1,000) SIC-72FW-F SIC-72FW-F Flare Flare 9.52(3/8) 9.52(3/8) Flare Flare 15.88(5/8) 15.88(5/8) x 834 x Χ 1,380 Χ 330 1,140 x 900 x 461 1,140 Χ 1,462 Χ Outdoor Unit Air-to-Water Heat Pump _ 3
35 3. Specifications Outdoor Unit Outdoor Units Power Supply Ø / V / Hz Maximum Running Cooling A Current Heating A Wiring Connections For Power Supply (Included Earth) Number of wires For Connection with Indoor Unit (Included Earth) Number of wires * Capacity Cooling(A35/W18) kw Heating(A7W35) kw * Power Input Cooling(A35/W18) kw Heating(A7W35) kw * EER Cooling(A35/W18) W/W COP Heating(A7W35) W/W Operation Range(Min.~Max.) Cooling C DB Outdoor Temperature Heating C DB Compressor Type - Model - Quantity EA Displacement cm 3 /Rev. Capacity kw Compressor Motor Type - Quantity EA Rated Output W Refrigerant Type - Charge g(oz) Control - Refrigerant Oil Type - Charged Volume cc Heat Exchanger Quantity EA Rows EA Columns EA FPI Fins/inch Fan Type - Quantity EA Air Flow Rate CMM(l/s) Fan Motor Model - Quantity EA Output W Sound Pressure Cooling db(a)±3 Level Heating db(a)±3 Liquid Piping Type - Connection Outer Diameter mm(inch) Gas Piping Type - Connection Outer Diameter mm(inch) Piping Length Minimum m (Outdoor Unit ~ Standard m Indoor Unit) Maximum m Height Difference (Outdoor Unit ~ Indoor Unit) Maximum m Additional Refrigerant Charge g/m Dimensions Unit(W x H x D) mm Packed Unit(W x H x D) mm Weight Unit kg Packed Unit kg AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) 1 / / 50 1 / / 50 3/ / ,690 5, ,150 3, ~ 48 5 ~ 48 5~48-20 ~ ~ 30-20~30 Hermetic Motor Hermetic Motor Hermetic Motor GPT425DBA GPT425DBA GPT425DAA (at 60Hz) Brushless Brushless Brushless ,000 4,000 4,000 R410A R410A R410A 2,850(100.5) 2,850(100.5) 2,980(105.1) Electronic Expension Valve Electronic Expension Valve Electronic Expansion Valve FVC68D FVC68D FV50S 1,300 1,300 1, Propeller Propeller Propeller (1,000) 60(1,000) 60(1,000) SIC-72FW-F SIC-72FW-F SIC-72FW-F Flare Flare Flare 9.52(3/8) 9.52(3/8) 9.52(3/8) Flare Flare Flare 15.88(5/8) 15.88(5/8) 15.88(5/8) Χ 1,380 Χ Χ 1,380 Χ x 1,380 x 330 1,140 Χ 1,462 Χ 461 1,140 Χ 1,462 Χ 461 1,140 x 1,462 x Note : 1. Capacities and power inputs are based on the following conditions: * : Cooling conditions - Indoor Water Temperature 23 C/18 C; Outdoor Air Temperature 35 CDB/24 CWB Heating conditions - Indoor Water Temperature 30 C/35 C; Outdoor Air Temperature 7 CDB/6 CWB Standard piping length 7.5m 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. 4 _ Air-to-Water Heat Pump
36 3. Specifications Outdoor Units Power Supply Ø / V / Hz Maximum Running Cooling A Current Heating A Wiring Connections For Power Supply (Included Earth) Number of wires For Connection with Indoor Unit (Included Earth) Number of wires * Capacity Cooling(A35/W18) kw Heating(A7W35) kw * Power Input Cooling(A35/W18) kw Heating(A7W35) kw * EER Cooling(A35/W18) W/W COP Heating(A7W35) W/W Operation Range(Min.~Max.) Cooling C DB Outdoor Temperature Heating C DB Compressor Type - Model - Quantity EA Displacement cm 3 /Rev. Capacity kw Compressor Motor Type - Quantity EA Rated Output W Refrigerant Type - Charge g(oz) Control - Refrigerant Oil Type - Charged Volume cc Heat Exchanger Quantity EA Rows EA Columns EA FPI Fins/inch Fan Type - Quantity EA Air Flow Rate CMM(l/s) Fan Motor Model - Quantity EA Output W Sound Pressure Cooling db(a)±3 Level Heating db(a)±3 Liquid Piping Type - Connection Outer Diameter mm(inch) Gas Piping Type - Connection Outer Diameter mm(inch) Piping Length Minimum m (Outdoor Unit ~ Standard m Indoor Unit) Maximum m Height Difference (Outdoor Unit ~ Indoor Unit) Maximum m Additional Refrigerant Charge g/m Dimensions Unit(W x H x D) mm Packed Unit(W x H x D) mm Weight Unit kg Packed Unit kg AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) 3/ /50 3/ / ~48 5~48-20~30-20~30 Hermetic Motor Hermetic Motor GPT425DAA GPT425DAA (at 60Hz) (at 60Hz) Brushless Brushless 1 1 4,000 4,000 R410A R410A 2,980(105.1) 2,980(105.1) Electronic Expansion Valve Electronic Expansion Valve FV50S FV50S 1,300 1, Propeller Propeller (1,000) 60(1,000) SIC-72FW-F SIC-72FW-F Flare Flare 9.52(3/8) 9.52(3/8) Flare Flare 15.88(5/8) 15.88(5/8) x 1,380 x x 1,380 x 330 1,140 x 1,462 x 461 1,140 x 1,462 x Outdoor Unit Note : 1. Capacities and power inputs are based on the following conditions: * : Cooling conditions - Indoor Water Temperature 23 C/18 C; Outdoor Air Temperature 35 CDB/24 CWB Heating conditions - Indoor Water Temperature 30 C/35 C; Outdoor Air Temperature 7 CDB/6 CWB Standard piping length 7.5m 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. Air-to-Water Heat Pump _ 5
37 4. Dimensions Outdoor Unit 3 4 [Unit:mm] AHUW096A1 (HU091 U41) Liquid side service valve(mm) Gas side service valve(mm) Air discharge grill Control Cover Note 1. Unit should be installed in compliance with the installation manual in the product box. 2. Unit should be grounded in accordance with the local regulations or applicable national codes. 3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes. 4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter. 6 _ Air-to-Water Heat Pump
38 4. Dimensions Supporter [Unit:mm] AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) Liquid side service valve(mm) Gas side service valve(mm) Air discharge grill Control Cover Note 1. Unit should be installed in compliance with the installation manual in the product box. 2. Unit should be grounded in accordance with the local regulations or applicable national codes. 3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes. 4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter. 490 Outdoor Unit Air-to-Water Heat Pump _ 7
39 5. Wiring Diagrams AHUW096A1(HU091 U41) Outdoor Unit 8 _ Air-to-Water Heat Pump
40 5. Wiring Diagrams AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) Outdoor Unit Air-to-Water Heat Pump _ 9
41 5. Wiring Diagrams AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) Outdoor Unit 10 _ Air-to-Water Heat Pump
42 6. Piping Diagrams AHUW096A1 (HU091 U41) AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) INDOOR UNIT OUTDOOR UNIT LIQUID SIDE EEV Th2 3-Way Service Valve Th6 Th7 Indoor Unit Plate Heat Exchanger Th3 Low Pressure Switch Outdoor Unit Heat Exchanger Th8 Description GAS SIDE 3-Way Service Valve Category Symbol Meaning Indoor Unit Outdoor Unit Th1 Th2 Th3 Th4 Th5 Th6 Th7 Th8 *1 EEV Remote air temperature sensor Th4 Accumulator Inlet evaporator temperature sensor Outlet evaporator temperature sensor Compressor-suction pipe temperature sensor Compressor-discharge pipe temperature sensor Condenser temperature sensor Outdoor air temperature sensor Condenser middle temperature sensor Electronic Expansion Valve COMPRESSOR PCB Connector CN_ROOM CN_PIPE CN_PIPE/O CN_TH3 CN_TH3 CN_TH2 CN_TH2 CN_TH3 CN_LEV1 Th5 High Pressure Switch Reversing Valve Remarks COOLING HEATING - Optional accessory (being sold separately) - Not shown in diagram - Meaning is expressed based on Cooling mode. - Th4 and Th5 are connected at 4 pin type connector CN_TH3. - Description is expressed based on Cooling mode. - Th6 and Th7 are connected at 4 pin type connector CN_TH2 - Th8 is connected at 4 pin type connector CN_TH3 - Adjusting mass flow rate of circulating refrigerant Outdoor Unit *1:Applied Model : AHUW128A1, AHUW148A1, AHUW168A1, AHUW096A1, AHUW126A1, AHUW146A1, AHUW166A1 Air-to-Water Heat Pump _ 11
43 7. Performance Data 7.1 Cooling Operation Model AHUW096A1 (HU091 U41) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI Model AHUW126A1 (HU121 U31) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI Model AHUW146A1 (HU141 U31) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI Outdoor Unit Model AHUW166A1 (HU161 U31) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI LWT : Leaving Water Temperature TC : Total Capacity (Averaged value) PI : Power Input Notice : Measuring procedure follows EN Notice : Above table values may not be matched according to installation condition 12 _ Air-to-Water Heat Pump
44 7. Performance Data Model AHUW128A1 (HU123 U31) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI Model AHUW148A1 (HU143 U31) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI Model AHUW168A1 (HU163 U31) Outdoor Temperature 20 C 30 C 35 C 40 C 45 C LWT 7 C LWT 10 C LWT 13 C LWT 15 C LWT 18 C LWT 20 C LWT 22 C TC PI TC PI TC PI TC PI TC PI TC PI TC PI LWT : Leaving Water Temperature TC : Total Capacity (Averaged value) PI : Power Input Notice : Measuring procedure follows EN Notice : Above table values may not be matched according to installation condition Outdoor Unit Air-to-Water Heat Pump _ 13
45 7. Performance Data 7.2 Heating Operation Model AHUW096A1 (HU091 U41) Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI Model AHUW126A1 (HU121 U31) Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI Outdoor Unit Model AHUW146A1 (HU141 U31) Model AHUW166A1 (HU161 U31) Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI LWT : Leaving Water Temperature TC : Total Capacity (Averaged value including defrost effect) PI : Power Input Notice : Measuring procedure follows EN Notice : Above table values may not be matched according to installation condition 14 _ Air-to-Water Heat Pump
46 7. Performance Data Model AHUW128A1 (HU123 U31) Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI Model AHUW148A1 (HU143 U31) Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI Model AHUW168A1 (HU163 U31) Outdoor Temperature -15 C -7 C -2 C 2 C 7 C 10 C LWT 35 C LWT 45 C LWT 50 C LWT 55 C TC PI TC PI TC PI TC PI LWT : Leaving Water Temperature TC : Total Capacity (Averaged value including defrost effect) PI : Power Input Notice : Measuring procedure follows EN Notice : Above table values may not be matched according to installation condition Outdoor Unit Air-to-Water Heat Pump _ 15
47 8. Capacity Correction Factor 8.1 Rate of change in the capacity by the piping length : AHUW096A1 (HU091 U41) Cooling Operation Heating Operation HU (m) HU (m) HL (m) HL (m) Outdoor Unit Symbols HU : Level difference between indoor and outdoor units where indoor unit in inferior position (m) HL : Level difference between indoor and outdoor units where indoor unit in superior position (m) L : Equivalent pipe length (m) α : Capacity correction factor 16 _ Air-to-Water Heat Pump
48 8. Capacity Correction Factor 8.2 Rate of change in the capacity by the piping length : AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) Cooling Operation HU (m) HU (m) Heating Operation HL (m) HL (m) Symbols HU : Level difference between indoor and outdoor units where indoor unit in inferior position (m) HL : Level difference between indoor and outdoor units where indoor unit in superior position (m) L : Equivalent pipe length (m) α : Capacity correction factor Outdoor Unit Air-to-Water Heat Pump _ 17
49 9. Operation Range 9.1 Cooling Operation AHUW096A1 (HU091 U41) AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) (Fan coil unit) (Under floor) Outdoor Temperature( ) Outdoor Temperature( ) Leaving Water Temperature( ) Leaving Water Temperature( ) Continuous Operation Outdoor Unit Operative 18 _ Air-to-Water Heat Pump
50 9. Operation Range 9.2 Heating Operation AHUW096A1 (HU091 U41) AHUW126A1 (HU121 U31) AHUW146A1 (HU141 U31) AHUW166A1 (HU161 U31) AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) (Fan coil unit or Radiator) (Under floor) Outdoor Temperature( ) Outdoor Temperature( ) Leaving Water Temperature( ) Leaving Water Temperature( ) Continuous Operation Operative Outdoor Unit Air-to-Water Heat Pump _ 19
51 10. Noise Criteria Overall 1m Microphone 1.5m Notes: - Sound measured at 1m away with 1.5m height. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference acoustic pressure acoustic 0dB-20Pa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. (db(a)±3) 1Φ, V, 50Hz Model Cooling Heating AHUW096A1 (HU091 U41) AHUW126A1(HU121 U31) AHUW146A1(HU141 U31) AHUW166A1(HU161 U31) (db(a)±3) 3Φ, V, 50Hz Model Cooling Heating AHUW128A1 (HU123 U31) AHUW148A1 (HU143 U31) AHUW168A1 (HU163 U31) Sound pressure level n Cooling(1Ø) 80 AHUW096A1 (HU091 U41) 80 AHUW126A1(HU121 U31) 80 AHUW146A1(HU141 U31) Outdoor Unit Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) 80 AHUW166A1(HU161 U31) 70 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) 20 _ Air-to-Water Heat Pump
52 10. Noise Criteria n Heating(1Ø) 80 AHUW096A1 (HU091 U41) 80 AHUW126A1(HU121 U31) 80 AHUW146A1(HU141 U31) Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC Approximate Hearing Threshold Octave Band Center Frequency (Hz) NC-25 NC-20 NC-15 AHUW166A1(HU161 U31) Approximate Hearing Threshold Octave Band Center Frequency (Hz) NC-25 NC-20 NC Approximate Hearing Threshold Octave Band Center Frequency (Hz) NC-25 NC-20 NC-15 Octave Band Sound Pressure Level (db re 20µPa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC Approximate Hearing Threshold n Cooling(3Ø) AHUW128A1 (HU123 U31) NC-25 NC-20 NC AHUW148A1 (HU143 U31) 80 AHUW168A1 (HU163 U31) Outdoor Unit Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) 20 NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) 20 NC-25 Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) Air-to-Water Heat Pump _ 21
53 10. Noise Criteria n Heating(3Ø) 80 AHUW128A1 (HU123 U31) 80 AHUW148A1 (HU143 U31) 80 AHUW168A1 (HU163 U31) Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 Octave Band Sound Pressure Level (db re 20Pa ) NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC NC NC NC-25 Approximate NC-20 Hearing Threshold NC Approximate NC-20 Hearing Threshold NC Approximate NC-20 Hearing Threshold NC Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Approximated SPL at specific distance : SPL[dB] = A + 20xLog(B/C) where A[dB] : SPL at 1m distance B[m] : 1m C[m] : specific distance Outdoor Unit 22 _ Air-to-Water Heat Pump
54 Part 4. Accessories 1. Dry Contact (PQDSA) 2. Remote Temperature Sensor (PQRSTA0) 3. PI485 (PMNFP14A0) 4. Sanitary Water Tank Kit(PHLTA) 5. Solar Thermal Kit(PHLLA / PHLLB)
55 1. Dry Contact (PQDSA) 1.1 Overview LG Dry Contact is a solution for automatic control of air conditioning system at the ownerʼs behest. In simple words, itʼs a switch which can be used to turn the unit On/Off after getting the signal from external sources like key-in lock, door or window switch etc specially used in Hotel rooms. Itʼs a small PCB that either can be fit inside the control box of Indoor unit or can be outside the unit in a plastic case if there is no sufficient space inside the Indoor unit. Apart from simple installation, it can also be linked to Central Controller via Indoor unit PI485 pcb. For this, all connecting wires & an additional small pcb for looping is also provided along with Dry Contact. Dry Contact can be used in two ways. 1. It can be used to actually turn On/Off the system on receiving the signal from the source. In this case, user doesn't need to use remote controller anymore to turn On/Off the system. However all the further settings like temperature, fan speed, mode etc can be done through remote controller only. 2. Other way is almost similar as above but in this case, after getting the On signal from the external source, user has to turn On the system from remote controller only. Dry contact just activates the system. However system can be turned Off directly from the external source. So only On mode is different here. So in both of above conditions, system canʼt be operated without signal from external source which prevents unnecessary use of system & facilitates its operation only when its required. These settings can be selected from the remote controller whose details have been explained in the later part of this manual So depending upon the requirement, Dry Contact offers a variety of applications to suit the customerʼs requirement in the best possible way. Power Connector Indoor PCB Connector Accessories Dry Contact Controller Connector Air-to-Water Heat Pump _ 1
56 1. Dry Contact (PQDSA) 1.2 Part Description 1 CN-POWER : AC 220V Connector CN-CC : Indoor PCB Connector CN_DRY (L) : DRY CONTROLLER Connector CN_DRY ( SIG ) : DRY CONTROLLER Connector CN_DRY (ERROR CHECK) : ERROR Check Display Connector CN_DRY( OPER STATE): Operation Display Connector Accessory Cable 1EA (for Central controller) Connecting PCB (6871A30056A) *for Central Controller Dry contact (For installation, 4EA) Cable 3EA (for connecting with indoor unit) Dry contact - 4EA (For assembly the case) Accessories NOTE [Structure of each cable] User/Installation Manual These cable using for connection between Dry contact and Indoor unit. So before using these things Please check the connector type first and use cables on proper indoor unit. 2 _ Air-to-Water Heat Pump
57 1. Dry Contact (PQDSA) 1.3 Installation Guide Step 1 Connect CN-CC with Indoor PCB by the cable(provided) - Connection of Dry contact only Indoor PCB CN-CC CN-CC DRY CONTACT PCB AC 220V - Connection of Dry contact & LG Central Controller in case of single constant models. Connection PCB (6871A30056A) Indoor PCB CN-CC CN-CC DRY CONTACT PCB AC 220V S1 BR1 ON L SWITCH U03Y OSC01B L02D L01D U04Y U02Y C01A LED1 LED01G LED02G LED03G IC01A PI485 PCB : Special purchase for Central Control (Ex : PHNFP14A0 or PSNFP14A0...) TANS01Y C03Y C04Y ZNR01Y CN_COMM * Single Only - When you install single product this PCB have to add. Accessories Air-to-Water Heat Pump _ 3
58 1. Dry Contact (PQDSA) Step 2 Connect CN_DRY with Control Unit. (Fix SUB PCB into the proper location.) - To apply power source through PCB DRY CONTACT PCB CN-CC RY1 RY CN_DRY N L Operation Display Error Check Display Dry contact Controller INPUT AC 220V LG does not supply this section - To apply power source directly to external source DRY CONTACT PCB CN-CC RY1 RY CN_DRY N L Operation Display Error Check Display Dry contact Controller INPUT AC 220V LG does not supply this section Accessories 4 _ Air-to-Water Heat Pump
59 2. Remote Temperature Sensor (PQRSTA0) 2.1 Part Description Remote temperature sensor can be installed any place a user wants to detect the temperature Remote Sensor 70mm Remote Sensor 120mm Connection Wire Parts Connection wire 15m(1EA) Fixing screw for Remote Sensor(2EA) Installation Manual Accessories Air-to-Water Heat Pump _ 5
60 2. Remote Temperature Sensor (PQRSTA0) 2.2 Installation Method How to use 1. After deciding where the remote temperature sensor is installed, decide the location and height of the fixing screws. (Interval between the screws : 60mm) Fixing screws 60mm 2. Insert the connector of the connection wire into the space for the connector in place of the room temperature sensor. (CN_ROOM) 3. Separately, set the option code of the attached controller on the indoor unit. In detail, refer to "installer setting mode" in the owner's manual How to connect the remote temperature sensor and the connection wire The Connection wire does not matter if you change the color of the wire because of non-polar How to install the remote temperature sensor on the wall Integrate the remote temperature sensor with the screws as the order of arrows. Fixing the Remote Sensor Accessories CAUTION 1. Choose the place where the average temperature can be measured for the place the indoor unit operates. 2. Avoid direct sunlight. 3. Choose the place where the cooling/heating devices do not affect the remote sensor. 4. Choose the place where the outlet of the cooling fan do not affect the remote sensor. 5. Choose the place where the remote sensor isnʼt affected when door is open. 6 _ Air-to-Water Heat Pump
61 3. PI485 (PMNFP14A0) 3.1 Part Description 1 KSDO4H ON L h The location of parts might be different in case of PMNFP14A1. PMNFP14A0 : For connecting 1 ~ 16 Indoor Units PI485 GATEWAY(M) 1 CN_PWR: AC 220V Connector 2 +10V: DC 10V Terminal 3 GND: Ground 4 BUS_A: *RS-485 (+) Terminal (Refer to note) 5 BUS_B: RS-485 (-) Terminal 6 CN_OUT: Outdoor Unit Connector 7 LED1:RS-485 Status LED 8 DIP Switch: Product Selection (Refer to the DIP Switch Configuration ) 9 LED01G, 02G, 03G: Communication Status LED 10 Reset Switch: PI485(M) Reset 11 CN_DRY: DRY Contact NOTE RS-485 is one of the international interface standards for serial communication. Accessories Air-to-Water Heat Pump _ 7
62 3. PI485 (PMNFP14A0) Accessories ON 3.2 Accessory Parts Multi-V KSDO4H L PI485 : PMNFP14A0(1EA) or PMNFP14A1(1EA) or PGNFP14A0(1EA) BRACKET (1EA) SCREW (4EA) Multi-V MPS Multi WIRE ASSY 1(1EA) WIRE ASSY 2(1EA) WIRE ASSY 3(1EA) Others : Tie Wrap (3 EA) - Cable Tie Clamp (1 EA) 8 _ Air-to-Water Heat Pump
63 3. PI485 (PMNFP14A0) 3.3 Installation Guide Installation Steps 1. 6 Connect CN_OUT with Outdoor Unit by the cable (provided) Connect RS-485 BUS_A(+) and BUS_(B)(-) with other network products (ex. Central Controller, I- Gateway...) In case of using Simple Central Controller, connect VCC(+10V) and GND. No need to connect otherwise Select DIP Switch Configuration(Refer page 8) 5. 1 Connect CN_PWR with Outdoor PCB Power connector (Refer page 9, 10) 6. After Power is ON, check the Communication LED 9 - LED1G(Red) Normal : LED blinks for 5 times and then gets OFF This process is repeated after every 3 minutes Error : Check the Indoor Unit's address & wiring connections - LED2G(Yellow), LED3G(Orange) Normal : LED blinks continuously Error : Check the DIP Switch setting & wiring connections 7. 7 Check RS-485 Communication Status LED: Normal : LED's blinks 2 times in every 10~30 seconds Error : Check the wiring connections 8. Finally if all of the above steps are OK, then tie the cables by tie wraps & clamp CAUTION Install the PI485 after checking the hole for screw. Accessories Air-to-Water Heat Pump _ 9
64 4. Sanitary Water Tank Kit(PHLTA) - Must be used for communication of sanitary water tank and indoor unit. 4.1 Part Description Sensor (Thermister) : This sensor (RHRSTA0) can be supplied separately. Sensor Adaptor - It can be attached on the sanitary water tank - Thermister is inserted in the sensor adaptor - connection 1/2"(12.7mm) BSP ELB (Earth Leakage Breaker) 40A Relay contactor Installation Manual Solar Thermal Kit(PHLLA / PHLLB) - Must be used for communication of solar thermal component and indoor unit. 5.1 Model - PHLLA : Sensorʼs limit temperature PHLLB : Sensorʼs limit temperature 120 Accessories 5.2 Part Description 1 Sensor (Thermister) 2 Sensor Adaptor - It can be attached on T type pipe fitting attatched in the pipe of solar thermal component - Thermister is inserted in the sensor adaptor - connection 1/2"(12.7mm) BSP 3 T type pipe fitting (option) _ Air-to-Water Heat Pump
65 P/No.: 3828A20892W Air Conditioner 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, , Korea. All rights reserved Printed in Korea June/2010 The specifications, designs, and information in this brochure are subject to change without notice. The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system.
AIR CONDITIONER SERVICE MANUAL. Please read this manual carefully before operating your set and retain it for future reference. System.
SERVICE MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. AH Series System P/NO : MFL67478328 www.lg.com 1. Specification Indoor Indoor
AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B)
AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B) CONTENTS Part 1. Indoor Unit(Hydro kit) Part 2. Outdoor Unit Part 3. Accessories Part 1. Indoor Unit (Hydro kit) 1. Features 2. Nomenclature
System SVC MANUAL. MODEL: AH Series CAUTION. Internal Use Only http://biz.lgservice.com
Internal Use Only http://biz.lgservice.com System SVC MANUAL MODEL: AH Series CAUTION Before servicing the unit, read the safety precautions in general SVC manual. Only for authorized service personnel.
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Multi Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A5UW306FA3 CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
Multi V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2 ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Versati Air to Water Heat Pump
Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
Air Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
Appendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
Technical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
Multi Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.co Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A7UW406FA3[FM40AH UH3] CAUTIN Before Servicing the unit, read the safety precautions in General SVC anual.
Condensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.
AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice
Unico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV
Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
Hot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.
TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/
SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the
INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.
INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
ROTEX gas hybrid heat pump. A strong team.
ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
DESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS
Europe Inverter Single 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A)
Europe 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A) -50Hz(R410A) 1. Models line up 2. Nomenclature 3. Features & Benefits 4. Specifications 5. Dimensions 6. Wiring diagrams 7. Refrigerant cycle diagrams
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE
AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
Nordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.
English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface
13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit
Troubleshooting 13. Troubleshooting Indoor unit s LED indication of Corona DC inverter unit MCAC-HTSM-2007-11 E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P5 EEPROM error outdoor communication error Zero-crossing examination
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
Daikin Altherma. hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet
Test Report issued under the responsibility of:
Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
YUTAKI S. Domestic Heating
YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance
Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73
MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
NEW 3-PIPE ECOi MF2 SERIES
NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3
EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:
innovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
Split Controller. User Manual SM-SS-F 2009/01/04
Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed
1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target
4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
How To Measure Temperature On A Thermostat
Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK20HD-S, SRK28HD-S, SRK40HD-S, SRK20CD-S, SRK28CD-S, SRK40CD-S CTENTS 1. GENERAL INFORMATI... 1 1.1 Specific features...
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most
DESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.
Room Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LSN092CE(ASNC0914DH0)/LSN092HE(ASNH091E1H0) LSU092CE(ASUC0914DH0)/LSU092HE(ASUH091E1H0) LSN122CE(ASNC121E1H0)/LSN122HE(ASNH121E1H0)
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS
AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS 2011 ECO IDEAS FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO 2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: 30% of total sales