Multi V Air Conditioner SVC MANUAL(Exploded View)

Size: px
Start display at page:

Download "Multi V Air Conditioner SVC MANUAL(Exploded View)"

Transcription

1 Internal Use nly Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2 ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.

2 1. Specification Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 Motor utput x Number W Running Current A (High Modefactory set) cfm Fan External Static Pressure mmaq(pa) (Standard Mode) cfm External Static Pressure mmaq(pa) Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm Net Weight kg(lbs) Noise Level(Sound Press, 1.5m, H/M/L) db(a) Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission cable mm 2 Ceiling Concealed Duct High Static ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA ,900 2,400 3,100 3,900 7,500 9,600 12,300 15, ,200 2,800 3,400 4,300 8,500 10,900 13,600 17,100 Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate 882x450x x450x x450x x450x x17.7x x17.7x x17.7x x17.7x10.2 2x10x21 2x10x21 2x10x21 2x10x Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan /7.5/6 10/8.5/7.5 12/10/ /12/ /230/ /282/ /353/ /424/353 8(80) 8(80) 8(80) 8(80) 8.5/8/ /8/7.5 11/8.5/8 13.5/12/11 247/230/ /282/ /353/ /424/353 6(60) 6(60) 6(60) 6(60) Direct Direct Direct Direct BLDC BLDC BLDC BLDC Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Foamed polystrene Foamed polystrene Foamed polystrene Foamed polystrene Fuse Fuse Fuse Fuse Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) (57.4) 26(57.4) 26(57.4) 26(57.4) 35/34/33 35/34/33 37/35/34 39/38/37 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60 1, 220, 60 1, 220, 60 EEV EEV EEV EEV CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C CVVSB 1.25 x 2C CVVSB 1.25 x 2C CVVSB 1.25 x 2C CVVSB 1.25 x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB utdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB utdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. EEV : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 nly for training and service purposes 2 LGE Internal Use nly

3 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 Motor utput x Number W Running Current A (High Modefactory set) cfm Fan External Static Pressure mmaq(pa) (Standard Mode) cfm External Static Pressure mmaq(pa) Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm Net Weight kg(lbs) Noise Level(Sound Press, 1.5m, H/M/L) db(a) Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission cable mm 2 Ceiling Concealed Duct(High Static) ARNU18GBHA2 ARNU24GBHA2 ARNU28GBGA ,800 6,100 7,100 19,100 24,200 28, ,400 6,900 8,000 21,500 27,300 31,500 Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate 882x450x x450x260 1,182x450x x17.7x x17.7x x17.7x10.2 3x10x21 3x10x21 3x12x Sirocco Fan Sirocco Fan Sirocco Fan /13.5/ /16.9/ /24.1/ /477/ /597/ /851/770 8(80) 8(80) 10(100) 15.3/13.6/ /16.4/ /21.8/ /480/ /579/ /770/622 6(60) 6(60) 8(80) Direct Direct Direct BLDC BLDC BLDC Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Foamed polystrene Foamed polystrene Foamed polystrene Fuse Fuse Fuse Ø6.35(1/4) Ø9.52(3/8) Ø9.52(3/8) Ø12.7(1/2) Ø15.88(5/8) Ø15.88(5/8) (58.4) 26.5(58.4) 38(83.8) 42.5/41/37 45/43/41 44/42/40 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60 1, 220, 60 EEV EEV EEV CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C CVVSB 1.25 x 2C CVVSB 1.25 x 2C CVVSB 1.25 x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB utdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB utdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. EEV : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 nly for training and service purposes 3 LGE Internal Use nly

4 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 Motor utput x Number W Running Current A (High Modefactory set) cfm Fan External Static Pressure mmaq(pa) (Standard Mode) cfm External Static Pressure Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device mmaq(pa) Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm Net Weight kg(lbs) Noise Level(Sound Press, 1.5m, H/M/L) db(a) Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission cable mm 2 ARNU36GBGA ,100 36, ,200 40,600 Galvanized Steel Plate 1,182x450x x17.7x10.2 3x12x Sirocco Fan /29/25.3 1,141/1,024/893 10(100) 28.4/25.3/21.8 1,003/893/770 8(80) Direct BLDC Microprocessor, Thermostat for cooling and heating Foamed polystrene Fuse Ø9.52(3/8) Ø15.88(5/8) (83.8) 46/44/42 1, 220 ~ 240, 50 1, 220, 60 EEV CV1.5 x 3C CVVSB 1.25 x 2C Ceiling Concealed Duct(High Static) ARNU42GBGA2 ARNU48GBRA ,600 12,100 42,000 48, ,000 13,200 43,800 51,200 Galvanized Steel Plate Galvanized Steel Plate 1,182x450x298 1,230x590x x17.7x x23.2x15 3x12x21 3x13x Sirocco Fan Sirocco Fan /32.3/ /40.6/33.3 1,218/1,141/1,084 1,582/1,434/1,176 10(100) 14(140) 32/28.4/ /39.5/33.5 1,130/1,003/961 1,568/1,395/1,183 8(80) 10(100) Direct Direct BLDC BLDC Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Foamed polystrene Foamed polystrene Fuse Fuse Ø9.52(3/8) Ø9.52(3/8) Ø15.88(5/8) Ø15.88(5/8) (83.8) 53(117) 48/46/45 45/43/41 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60 EEV EEV CV1.5 x 3C CV1.5 x 3C CVVSB 1.25 x 2C CVVSB 1.25 x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB utdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB utdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. EEV : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 nly for training and service purposes 4 LGE Internal Use nly

5 2. List of Functions Category Air flow Air purifying Installation Reliability Convenience Individual control Special function kit Function Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / antifungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Wide Character wired remote controller Picto wired remote controller Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Zone control CTIE Electro thermostat ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2, ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2, ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2, ARNU48GBRA2 1 3/3/3 (only heat recovery) (only heat pump or cooling only) : Applied : Not applied : No relation ption : Model name & price are different according to options, and assembled in factory with main unit. : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. nly for training and service purposes 5 LGE Internal Use nly

6 3. Piping Diagrams Heat Exchanger EEV Filter :Cooling :Heating Th3 Sirocco Fan Th2 Filter Th1 lndoor unit Refrigerant pipe connection port diameter [unit: mm(inch)] MDEL GAS LIQUID ARNU07GBHA2 Ø12.7(1/2) Ø6.35(1/4) ARNU09GBHA2 Ø12.7(1/2) Ø6.35(1/4) ARNU12GBHA2 Ø12.7(1/2) Ø6.35(1/4) ARNU15GBHA2 Ø12.7(1/2) Ø6.35(1/4) ARNU18GBHA2 Ø12.7(1/2) Ø6.35(1/4) ARNU24GBHA2 Ø15.88(5/8) Ø9.52(3/8) ARNU28GBGA2 Ø15.88(5/8) Ø9.52(3/8) ARNU36GBGA2 Ø15.88(5/8) Ø9.52(3/8) ARNU42GBGA2 Ø15.88(5/8) Ø9.52(3/8) ARNU48GBRA2 Ø15.88(5/8) Ø9.52(3/8) LC. Th1 Th2 Th3 Description Room thermistor Pipe in thermistor Pipe out thermistor nly for training and service purposes 6 LGE Internal Use nly

7 4. Wiring Diagrams BH Chassis CN_PIPE/IN CN_PIPE/UT CN_REM CN_RM CN_CM CN_D/PUMP CN_CC CN_PWER CN_DISP CN_PTIN CN_EEV CN_ZNE CNFLAT CN_MTR1 CN_MTR2 nly for training and service purposes 7 LGE Internal Use nly

8 5. Exploded View BH W1JK B A B A THERMISTR B THERMISTR C W A THERMISTR C D W0FZZ W A B W Thermistor A Air Housing color : yellow Thermistor B Eva. in Housing color : white Thermistor C Eva. out Housing color : red nly for training and service purposes 8 LGE Internal Use nly

9 BG W1JK B A B A THERMISTR 2 THERMISTR B C W0FZZ W A THERMISTR D C E W W G B A Thermistor A Air Housing color : yellow Thermistor B Eva. in Housing color : white Thermistor C Eva. out Housing color : red nly for training and service purposes 9 LGE Internal Use nly

10 BR W1JK A B THERMISTR B THERMISTR C W0FZZ W A THERMISTR C W D E G W B A Thermistor A Air Housing color : yellow Thermistor B Eva. in Housing color : white Thermistor C Eva. out Housing color : red nly for training and service purposes 10 LGE Internal Use nly

11 P/N : MFL January, 2008

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A5UW306FA3 CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for

More information

PRODUCT CATALOG. Indoor Units

PRODUCT CATALOG. Indoor Units PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?

More information

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.co Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A7UW406FA3[FM40AH UH3] CAUTIN Before Servicing the unit, read the safety precautions in General SVC anual.

More information

System. SERVICE MANUAL R410A (Exploded View)

System. SERVICE MANUAL R410A (Exploded View) Internal Use nly http://biz.lgservice.com System utdoor Unit R410A SERVICE MANUAL R410A (Exploded View) MDEL : ARUN Series CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.

More information

System. SERVICE MANUAL R410A (Exploded View)

System. SERVICE MANUAL R410A (Exploded View) Internal Use nly http://biz.lgservice.com System utdoor Unit R410A SERVICE MANUAL R410A (Exploded View) MDEL : ARUN Series CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LSN092CE(ASNC0914DH0)/LSN092HE(ASNH091E1H0) LSU092CE(ASUC0914DH0)/LSU092HE(ASUH091E1H0) LSN122CE(ASNC121E1H0)/LSN122HE(ASNH121E1H0)

More information

Air Conditioner SVC MANUAL(General)

Air Conditioner SVC MANUAL(General) Internal Use nly http://biz.lgservice.com Air Conditioner SVC MANUAL(General) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.

More information

AIR CONDITIONER SERVICE MANUAL. Please read this manual carefully before operating your set and retain it for future reference. System.

AIR CONDITIONER SERVICE MANUAL. Please read this manual carefully before operating your set and retain it for future reference. System. SERVICE MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. AH Series System P/NO : MFL67478328 www.lg.com 1. Specification Indoor Indoor

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

innovative comfort solutions

innovative comfort solutions engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,

More information

Multi Air Conditioner SVC MANUAL(General)

Multi Air Conditioner SVC MANUAL(General) Internal Use Only http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(General) MODEL : Multi-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Single Zone Air Conditioner SVC MANUAL(General)

Single Zone Air Conditioner SVC MANUAL(General) Single Zone Air Conditioner SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 960-914-06 Air Conditioner Service

More information

Celxia. http://www.lge.com. a s. Artcool uses state-of-the art technology to assure customer satisfaction.

Celxia. http://www.lge.com. a s. Artcool uses state-of-the art technology to assure customer satisfaction. http://www.lge.com Artcool uses state-of-the art technology to assure customer satisfaction. a s Kulde Varmepumpe Ventilasjon Aircondition Varmeanlegg Celxia Tlf: 69 26 85 00 Faks: 69 26 85 01 www.celxia.no

More information

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Residential and Light Commercial Air Conditioning Systems

Residential and Light Commercial Air Conditioning Systems Residential and Light Commercial Air Conditioning Systems Beautifully Designed to Save Engineering and Specifications Guide Beautifully Designed to Save As air conditioners have reached high levels of

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal

More information

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible LG Duct-Free Split Systems Product Overview LG comfort solutions that you never thought possible TABLE OF CONTENTS Company Introduction Introduction 4 Duct Free System Introduction 6 Key Features 8 Duct-Free

More information

Instruction manual for Firstline FCS12000CH

Instruction manual for Firstline FCS12000CH Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Ventilation System Air Conditioner SVC MANUAL(Exploded View)

Ventilation System Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Ventilation System Air Conditioner SVC MANUAL(Exploded View) MODEL : LZ-H015GBA2 LZ-H025GBA2 LZ-H035GBA2 LZ-H050GBA2 LZ-H080GBA2 LZ-H100GBA2 LZ-H150GBA2 LZ-H200GBA2

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS

More information

Residential and Light Commercial Air Conditioning Systems

Residential and Light Commercial Air Conditioning Systems Residential and Light Commercial Air Conditioning Systems Beautifully Designed to Save Engineering and Specifications Guide Beautifully Designed to Save As air conditioners have reached high levels of

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

Pioneer in sustainability

Pioneer in sustainability Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.

More information

LG Air Conditioning & Energy Solutions Price List

LG Air Conditioning & Energy Solutions Price List LG Air Conditioning & Energy Solutions Price List Valid from March 2015 Splits VRF Heat Pumps Ventilation Controls Introduction About LG Electronics Air Conditioning and Energy Solutions LG manufactured

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

Split System Air Conditioners SkyAir Inverter

Split System Air Conditioners SkyAir Inverter SiUS28-902_a SiUS28-902 06/2009 AK Service Manual / SkyAir Inverter R-410A Heat Pump 60Hz / P Series SiUS28-902 Specifications, designs and other content appearing in this brochure are current as of June

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

Technical Service Manual. Version One

Technical Service Manual. Version One [Gree Central Air Conditioner] Technical Service Manual Ducted type unit 2.3KW-16KW Version One GREE ELECTRIC APPLIANCES.INC.OF ZHUHAI - 1 - FG Series wind pipe blowing air-conditioning unit Section One:

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90 6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

Multi Air Conditioner SVC MANUAL(General)

Multi Air Conditioner SVC MANUAL(General) Internal Use Only http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(General) MODEL : Multi-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only

More information

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will

More information

How To Measure Temperature On A Thermostat

How To Measure Temperature On A Thermostat Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK20HD-S, SRK28HD-S, SRK40HD-S, SRK20CD-S, SRK28CD-S, SRK40CD-S CTENTS 1. GENERAL INFORMATI... 1 1.1 Specific features...

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

Air Conditioning & Heat Pump Products

Air Conditioning & Heat Pump Products Air Conditioning & Heat Pump Products Preliminary Revised April 06 SANYO Air Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000 Type Standard Low Ambient Standard Low

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED

More information

Customized Assessment Blueprint

Customized Assessment Blueprint Customized Assessment Blueprint HVAC Installer Basic - Test Codes: 7906 and 7796 Measuring What Matters Competencies and Skills Tested in this Assessment: HVAC Theory Heat Theory and Refrigeration HVAC

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

Single Zone LCD Thermostat Operating Instructions

Single Zone LCD Thermostat Operating Instructions Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2 SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-

More information

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14 Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type ) Manual No. 06. SRK-T. 050 updated September 29, 2009 INVERTER WALL MOUNTED TYPE ROOM AIR-CDITIER ( Split system, air to air heat pump type ) SRK20ZD-S1, SRK25ZD-S1, SRK35ZD-S1, SRK50ZD-S1 SRK63ZE-S1, SRK71ZE-S1

More information

8 0 0 2 k.u o.c e.lg w w w

8 0 0 2 k.u o.c e.lg w w w www.lge.co.uk 2008 LG Air Conditioning features guide EO Plasma Air Purifying System Anti Corrosion Gold Fin Auto Cleaning Auto Changeover Jet Cool Healthy Dehumidification Auto Restart Hour O/OFF Setting

More information

Multi Air Conditioner SVC MANUAL(General)

Multi Air Conditioner SVC MANUAL(General) Internal Use Only http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(General) MODEL : Multi-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Ceiling Cassette Air Conditioner

Ceiling Cassette Air Conditioner website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG LG Ceiling Cassette Air Conditioner SERVICE MANUAL MDEL: LCN240CP/LCU240CP LC240CPI/LC240CP LCN340CP/LCU340CP LC340CPI/LC340CP

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................

More information