RS232/485 - ETHERNET Converter
|
|
|
- Roy Chapman
- 9 years ago
- Views:
Transcription
1 RS232/485 - ETHERNET Converter
2 The complete shipment contains Closed converter box with a unique preset MAC address. RS232 interconnection cable (serial port extension cord, Cannon 9-1:1) Propojovací kabel RS232 (prodloužení sériového portu Cannon 9-1:1) Datasheet. We can supply upon request: Brackets for wall mounting. RS232/RS485 conversion module (no galvanic insulation) Basic communication types TCP server (Passive mode) After powering up, the converter listens on the given port and awaits client connection. When the client connects, data from the Ethernet are sent to the serial line and vice versa. If the client is not connected and data are coming from the serial line, they are stored in a buffer (size is configurable) and transmitted immediately after establishing a connection, unless clearing of the buffer upon establishing a connection has been requested in the SETUP. TCP client (Active mode) The converter behaves similarly to the previous case. However, when data arrive from the serial line, it tries to actively establish the connection to the specified remote IP address as a client and transmit the data. If it does not succeed, data are kept in the buffer and transferred as soon as a connection is established, regardless of the converter connection mode (client or server). In this mode, two converters communicating with each other can "tunnel" the serial line through the Ethernet. And, when using the Charon modules or the I/O Controller, the Ethernet can be used to extend the parallel inputs and outputs as well. UDP Data from the Ethernet are expected on a given port. Data coming from the serial line form a packet according to the specified triggers and are sent to a specified IP address. During UDP transfer, acknowledgements from the remote side are not verified; the application itself should support recovery from a data loss. An advantage is a shorter response time, useful especially for RS485 lines. NVT (Network Virtual Terminal) When using TCP/IP communication, the converter function can be enhanced via NVT according to RFC2217 using a control data stream that can, for example, change the baud rate of the remote serial port, control inputs and outputs, or clear the buffer. These control commands are mixed into the data stream and prefixed with "FF" ("FF"s in the regular data stream are doubled). Detailed description of NVT is available in the "Programming Ethernet Applications" guide at our website that also describes the supplied communication subroutines. February 2003 page 2 / 16
3 RS232/485 - ETHERNET Converter The asynchronous serial line conversion to the ethernet include support of RS485 protocols. Features : TCP/IP, UDP/IP., NVT, TEA and many more.. The I/O Controller contains all functions of the converter and adds support of binary inputs + outputs with using the NVT see the last chapter Converter features Serial RS232 port accessible over an Ethernet network. Configurable communication speed Bd, handshake (CTS/RTS, Xon/Xoff, none) RJ 45 interface - 10BASE-T and RS-232. Parameters configured locally over RS232 or over the Ethernet using a Windows application. Support for TCP/IP data transfer - TELNET-like client + optional NVT support (Network Virtual Terminal) Option to activate UDP transfer with RS485 support. Triggers for packet start and packet end. Support for passive or active mode (the converter can establish a connection with the remote side upon serial line activity) Two devices can extend a serial port over the Ethernet. Security measures consist of a fixed specification of the remote IP address range and optional connection authorization using the 128-bit TEA encryption algorithm. Support for interfacing with special software, or a Windows configuration application. It is possible to add x51 assembly code for protocol conversion between the Ethernet and the serial line. This way the converter can for example recognize your proprietary protocols and so on. Converter Applications Instrumentation control and monitoring over the Ethernet. Connection of any device controlled over RS232 to the Internet through Ethernet. Securely authorized access to a device over the Internet from anywhere. Support for UDP communication - fast and advantageous for Ethernet LANs. Basic HW parameters Electrical parameters Network parameters Power supply DC 8-20V / 0 2A - Polarity: Supported protocols TCP/IP + NVT, UDP/IP Dimensions 38 x 105 x 135 (H x W x D ) RS232 - transfer rate Bd Temp. ranges Temperature : 5 50 C RS232 data stream RTS/CTS, Xon/Xoff, none Ethernet RJ45 10BaseT IEEE RS232 - data 8 or 7 data bits Serial port 1x DB9F (RxD,TxD,RTS,CTS,GND) RS232 parity None/Odd/Even/Mark/Space RS485 With internal RS485 module only TCP connection close Data/ACK/NOP timeout 50s February 2003 page 3 / 16
4 Connector description PC RS232 Port Cannon 9 - Male Pin 1 <- CD 2 <- RxD 3 -> TxD 4 -> DTR 5 -- GND 6 <- DSR 7 -> RTS 8 <- CTS 9 <- RI Signal RS485 converter module RS232 Converter Port Cannon 9 - Female Pin Signal 1 <-> 2 -> TxD 3 <- RxD 4 Setup ON 5 -- GND 6 B RS485 7 <- CTS 8 -> RTS 9 <-> A RS485 Power supply: DC 8..20V / max. 0.3 A Ethernet : The module for physical RS485 conversion is not supplied. However, it can be ordered as a separate accessory for no additional charge. The RS485 line is wired according to the description of the Cannon 9 connector. When installing the module, please remove the top two jumpers and insert the module. For configuration, you will probably need to use the original RS232. Do not forget to insert the two jumpers after removing the module. Looking at the converter with the Cannon 9 and RJ45 connectors on the right side, the top two jumpers next to the Cannon 9 connector need to be in place. Two empty jumper positions should remain below them. Here is a detailed diagram of the connector wiring. Converter connection configurations Converter <-TCP/IP-> PC The PC can open a network connection, e.g. with the TeraTerm program, to the converter IP address and port 23. For the opposite direction, a server program needs to be installed on the PC. This mode is the most common one for monitoring and remote control of any device over the serial port. Converter <-UDP/IP-> PC Special software is needed for connecting to the converter. UDP is intended for transferring data on a local segment of an internal network only. We do not recommend UDP for communication over longer distances. Converter <-TCP/IP-> Konvertor Two devices bridge the serial ports over the Ethernet network - creating a "virtual wire". Converters can authorize themselves upon establishing the connection, remote IP addresses can be restricted. As a result, serial ports of two devices can be connected together via the world-wide network. The serial ports can communicate with different speeds; this can sometimes decrease latency. Converter <-UDP/IP-> Konvertor Special software is needed for connecting to the converter. UDP is intended for transferring data on a local segment of an internal network only. We do not recommend UDP for communication over longer distances. February 2003 page 4 / 16
5 Installation Mechanical installation Converter is supplied in a metal box with four self-tapping screws in the sides. The screws are 80 mm apart, their diameter is 3 mm. The box can be attached with these screws into a custom "L" profile 1.2 mm thick. We supply the sidewise "L" profiles as optional accessories. Drawings of the box and the profiles are available upon request. Configuring the converter parameters The converter needs to be configured before it can be used in routine operation. Converter parameters (IP address, mask, gateway, serial port speed, etc.) can be configured by the software shown in the figure. It is available for download at our website. Three configuration methods are available: Locally over a RS232 serial line. All parameters can be configured using a textual setup menu. Over the network, using an UDP application for Windows. Basic network parameters are configurable.limited to a local Ethernet segment only. Over the network using TCP (everything can be configured and the device can be anywhere; however, the netmask, GW and IP address must be pre-configured and cannot be changed in this mode). Remote configuration over TCP/IP has to be enabled through a special option accessible in the RS232 SETUP. SETUP over the serial RS232 line For converter configuration, set the RS232 line parameters to 9600Bd, 8N1. The PC can be connected using the supplied cable with Canon 9 connectors. Activation of the setup mode: Drive pin 4 (DTR) low when the converter powers up. Jumper JP3 needs to be in the 1-2 ("PC") position - factory default. This method is used by the configuration SW. Automatically at power up, if the jumper JP3 is in the 2-3 position ("SETUP"). (to the left from the connectors). The setup menu cannot be activated if the jumper JP3 is removed entirely. February 2003 page 5 / 16
6 The converter can be configured using any terminal in line mode, you don't need our software. However, in that case, you need to manipulate with the JP3 jumper, or need a terminal that can define the value of DTR - for example, TeraTerm can't do it. The configuration itself is performed by communicating with the converter over the serial line. After powering up, the converter tests the JP3 jumper. If present, it sends the following screen over the serial port. (Port settings: 9600 Bd 8N1) If the converter does not respond, verify the serial port settings. If no success, verify the serial cable wiring. Then, verify the JP3 setting on the converter board. Network activity (receiving and transmitting) is indicated by the LEDs ETx and ERx on the PCB turning off. The converter reacts to ICMP Echo requests ("ping") for the given IP address. Response time is 4 ms. To set the IP address for testing "PING" replies, our program in UDP mode can be used. The configuration itself is performed by typing the letter(s) identifying the option and its value. (for examle I to set the device IP address). Help for an option is printed by sending its letter, question mark and <Enter> I? <Enter>. A figure detailing this configuration process is shown on the page with the list of configuration options. Over the network using UDP The configuration is performed using our program; see the figure on the previous page. In this mode, the converter can be detected and configured on a local network segment only. No routers, firewalls, or other devices filtering UDP broadcasts can stand in the way. Over the network using TCP Using our program or any telnet that supports TEA. See the figure on this page for an example. This setup can be disabled by the "%S: TCP/IP setup" option in the RS232 setup. This configuration mode is protected with the chosen TEA key that is required for access to the device (unless the password requirement is disabled in the setup). Thus, the configuration process is secure enough even for remote configuring from anywhere in the world. Note: Configuration over TCP is not possible for HW version 4.5 and the "I/O Controller" version. February 2003 page 6 / 16
7 Application tips and recommendations Security To increase security in TCP mode, both sides can authorize themselves via the symmetric TEA 128 cipher whenever a connection is established. The password set on both sides will not travel over the network. This option is available only for TCP/IP connections. UDP mode is intended for local networks only. Detailed TEA description is available in the "Programming Ethernet Applications" guide at our website. Increasing connection timeout Since the converter supports only one concurrent connection, a timeout needs to be set. By default, a connection is terminated 50 seconds after the last data transfer. However, it is possible to enable "K: Keep connection" to send a NOP into the open NVT connection once about every 10s. Starting with version 2.4, a new function will allow a connection to remain open after timing out until someone else wants to establish another connection. In that case, if no data are transmitted for about 50s and someone else tries to access the converter, the converter closes the inactive connection and attends to the new connection. Access to the NVT port Starting with version 2.4, a separate port with enabled processing of NVT commands is implemented on the same IP address. The original port can have the NVT commands turned off. This can be used for example to create a transparent "raw" conversion from the IP address to RS232 and at the same time control inputs and outputs via NVT on another port, or use 9-bit RS232 communication. Packet triggers in the UDP mode The converter in UDP mode supports RS485 protocols. By configuring the protocol parameters, response time over the Ethernet can be reduced from about ms in TCP/IP mode to ms. The converter can recognize the end of a RS485 packet and send the data to the other side without waiting for a timeout to expire. The following conditions trigger the end of collecting data from RS485 and transmission over the Ethernet in one packet. When the triggers overlap, the packet is sent if any one of them is activated. Start and end of a packet is triggered by a sequence of 1 to 4 bytes with a configurable mask. February 2003 page 7 / 16
8 Converter SETUP mode MAC Address 00:0A:59:00:95:6C MAC address is a unique network device address in the Ethernet and is always factory-preset. You can find it on the label inside the device. Using this address, the devices can be distinguished for example in the UDP mode of the configuration program. The address respects restoring of the default configuration with the "D0" command. I: Address Configuration of the converter's IP address. J: Port 23 Configuration of the converter's communication port range: Port 99 is used for TCP configuration, if supported by the version and enabled in the setup. M: Mask Configuration of the IP mask for the local network. All IP addresses outside of the area delimited by the converter's own IP address and this mask will be accessed via the Gateway. G: Gateway Address of the gateway that provides access to outside networks, as defined by the IP address and the mask. Consequence of the MASK, IP and GW Ethernet device communicates : You don t even need Gateway in local ethernet but IP adrresses of both sides must be chosen from allowed mask. Therefore there might be difference on the last byte only from IP address when configuraton of mask is Out of local net - use Gateway, that is located in MASK allowed range of IP addresses. Besides basic configuration it is possible to restrict the range of IP addresses that the conveter will not communicate with in In IP Setup. We recommend to keep this paramether on the value ====== In IP Setup ====== W: Address IP address of a network or computer that is allowed to communicate with the converter. This value must result from multiplying the remote IP address and the restriction mask (option N), otherwise the converter does not react. N: Mask This mask restricts addresses that may communicate with the converter. Security can be greatly enhanced by setting a fixed address or a suitable restrictive mask that disallow communication with unauthorized parties. February 2003 page 8 / 16
9 ====== Out IP Setup ====== S: Send to IP U: Port 23 Remote IP address and port for establishing a connection upon reception of data from the serial port. Value switches the converter into passive mode. Note: If UDP communication is used, a remote address must be specified here. The converter does not establish connections, responses are sent to this address only! T: IP mode TCP Switches between the TCP and UDP protocols. UDP is faster but packets can be lost or delivered out of order. Hence it is suitable for communication only on a local network segment in request-reply mode, usually for converting a RS485 communication. UDP communication is hard to debug since there is no simple PC terminal (like TELNET for TCP/IP). Switches between the TCP and UDP protocols. UDP is faster but packets can be lost or delivered out of order. Hence it is suitable for communication only on a local network segment in request-reply mode, usually for converting a RS485 communication. UDP communication is hard to debug since there is no simple PC terminal (like TELNET for TCP/IP). IP mode: 0: TCP / 1: UDP V: NetworkVirtualTerminal Off Network Virtual Terminal allows the interpreting of Telnet protocol sequences including certain RFC2217 extensions, enabling on-the-fly changes of serial port parameters (speed, parity,...). NVT description is available in the "Programming Ethernet Applications" guide at our website. When communicating with the serial port using telnet, e.g. with the TeraTerm program, this option should be turned on. Otherwise, telnet control commands (seen as "junk") intended for configuration negotiation at the beginning of the communication are forwarded to the serial port. If you don't want to use this option, set your client to RAW communication mode. 0: Off (don't use telnet control code, pass through to serial port) 1: On (accept telnet control code) K: Keep connection Off This option allows keeping the connection alive with NOP commands, as long as NVT is on. (see "Increasing connection timeout" in the Application Tips section). 0: no keep connection (prefered) 1: keep connection E: Erase buffer on Open connection Option to clear the internal converter buffer whenever a connection is established or closed. This option is useful e.g. if your device periodically says "I'm alive" and you don't want to waste time retrieving these notifications from the buffer. 0: none 1: close TCP/IP connection 2: open TCP/IP connection 3: open & Close TCP/IP connection February 2003 page 9 / 16
10 ====== Serial Setup ====== &B: Speed 9600 Configuration of the communication speed for the serial line, range Bd. To set 9600 Bd, enter : &B9600. &D: Data bits 8 Number of data bits for the serial transfer. Options are : 7: 7 bits / 8: 8 bits issue &D8 &P: Parity NONE Parity of the serial asynchronous communication: N: none / O: odd / E: even / M: mark / S: space &S: Stop bits 2 Number of stop bits for the RS232 serial line. It is possible to set 1 or 2 bits. &C: Flow Control NONE Flow control configuration for the serial ports. For details, see the box on the previous page. 1: none - No flow control, see &R for the RTS level. 2: RTS/CTS Control pins RTS/CTS 3: Xon/Xoff - SW flow control. &R: RS485/RS422 control Defines idle level of the output RTS pin. Important for devices powered from RTS or for add-on RS485 converters that use RTS to switch direction. Especially for the internal RS485 module, the "HW echo" option should be on. This means that the receiver reads the data back from RS485 and generates hardware echo from the actual RS485 bus. Note: For the internal RS485 module, use &R3 and &R4 options. 0: RTS = Low [+8V] (recomended for non RS485/422 mode) 1: RTS = High [-8V] 2: TxRTS HW echo ON 3: TxRTS HW echo OFF &T: Serial Line Timeout 0 Off Specifies how long the converter waits after receiving a character before wrapping up the data in a packet and transmitting them. The timeout is specified as the number of characters and displayed as the number of chars as well as time according to the given serial communication speed. If the speed changes, the time is changed also but the number of characters defining the timeout is not (10 characters at 9600 Bd = about 11 ms, or 5.7ms at 19,200 Bd). February 2003 page 10 / 16
11 &G: Char. Transmit Delay 0 Off For controlling units with small RS232 buffer, it is sometimes advantageous to keep relatively high baudrate but insert delays between individual characters. The delay is in milliseconds and is defined as the time between the starts of individual characters; so, for 2400 Bd a 2ms delay has no effect since the character starts are 2.4 ms apart. &H: Tx Control Tx FULL duplex When HALF duplex is activated, the converter assumes unidirectional medium connected to the serial line (e.g. RS485) and won't start transmitting data while receiving. 0: FULL duplex 1: HALF duplex (RS485) &M: Serial buffer size Medium Rx / Medium Tx Sets the size of the ring buffer in the converter memory for individual directions. For example, to collect data from the serial line, it is advantageous to use option "2: High Rx / Low Tx". 0: Medium Rx / Medium Tx (approx. 50% / 50% of memory) 1: Low Rx / High Tx (approx. 30% / 70% of memory) 2: High Rx / Low Tx (approx. 70% / 30% of memory) &O: Buffer SpaceCompresion Off Memory can be sometimes saved using space compression - especially when storing unified lines of text. In such a case, one of the compression options can be useful: 0: Off 1: On (compress on serial buffer, send unexpanded on I/O) 2: Transparent (compress on serial buffer, expand on I/O) ===== Security Setup ====== %A: TCP autorisation Off Activates TEA authorization - requested from the remote side after the connection is established. 0: TEA authorisation Off 1: TEA authorisation On %K: TEA key 0:01:02:03:04 1:05:06:07:08 2:09:0A:0B:0C 3:0D:0E:0F:10 To set the TEA key, use the "%K" option. Set 16 bytes in quadruples using four hexadecimal values separated with colons. The first string defines 0-3rd quadruple of bytes. So, to set the last 4 bytes to the displayed value, use "%K 3:0D:0E:0F:10". %S: TCP/IP setup On Enables remote configuration via the TCP setup. ========= Other ========= D: Load/Save Settings from/to Flash Options "D0" and "D1" reload default factory settings. R: Reboot Soft restart of the converter. Necessary after changing the IP address, etc. February 2003 page 11 / 16
12 UDP mode settings If you select "T: IP mode UDP", the converter will communicate with the remote side using unacknowledged UDP packets. Also, the following menu appears in the setup. ==== Trigerring Setup ===== *L: Trigger Length 1 Number of bytes of the start and end packet trigger condition. Allowed values are 0 to 4. If the lengths of your start and stop triggers differ, use the trigger mask and don't forget to include the masked characters in the lengths - even though they contain actual frame data. *P: Post Trigger Length 0 In some protocols, checksum or other info follows the stop trigger. This value defines the number of characters after the stop trigger that should be included in the packet. If the start and stop triggers are equal, this value specifies packet length less the 0 to 4 bytes of start trigger. *S: Start Trigger Pattern Start trigger for packet transmission. Four bytes are set, but only the number of bytes specified in "L: Trigger Length" is considered. *M: Start Trigger Mask Mask of the start trigger. Masking works similarly to the ethernet netmasks, using a bitwise AND. Value of 255 means that the tested character must be equal to the character specified in "*S: Start Trigger Pattern". For example, to start the transfer with any control ASCII character (0..31d), use for the trigger pattern, for the mask, and 1 for the length. If you set both the character and the mask to 0, the trigger activates for any character. *X: Stop Trigger Pattern Sets the stop trigger for sending data to the Ethernet. *Y: Stop Trigger Mask Mask of the stop packet trigger for serial line data. For example, the settings displayed here are intended for transferring data in the IntelHEX format over RS485. The start trigger is a colon and the transfer is terminated after receiving the control character <LF> (0Ah = 10d). *E: Max. Start-Stop Length 999 Maximum number of characters sent after the start trigger, if the stop trigger is not found sooner. After transmission, another START trigger is expected. Essentially, this is a "timeout" specified as the number of characters. February 2003 page 12 / 16
13 Configuring the I/O Controller Parameters The I/O Controller product contains all the functions of the classic converter. It adds the options to control parallel inputs and outputs. The Charon module uses the 8-bit port P1 as these inputs and outputs. The IO Controller command activates the I/O Controller configuration menu. In practice, the inputs and outputs can be controlled via Network Virtual Terminal. Its complete description, together with command examples, is available in the "Programming Ethernet Applications" guide at our website. Inputs of the I/O Controller All 8 inputs are implemented using 8 optocouplers with a common ground on the IGND pin. The optocouplers input voltage range is V. The IGND pin needs to be connected to GND on the outside connector. Then, the pins can be simply controlled via contacts to the POWER pin that provides supply voltage from the adapter input on the Cannon 37F connector. Maximum current load of the Power pin is 300 ma! Outputs of the I/O Controller Outputs are implemented with eight transistors using the "open collector" circuit. Two outputs are internally connected to a relay whose switching contacts are also available. The protective diodes of the transistors are connected to the common pin, which should be connected to the positive supply terminal of e.g. external relays. This way the pins are be protected from voltage spikes. The diagram next to the Cannon 37F pinout table shows the pin connections. 8x INPUTS 8x OUTPUTS 2x RELAYS Name Description Pin Power External adapter power supply (8-20V) 28 GND Ground 29 GND Ground 20 I0 Optocoupler Input 5-15V 16 I1 Optocoupler Input 5-15V 15 I2 Optocoupler Input 5-15V 14 I3 Optocoupler Input 5-15V 13 I4 Optocoupler Input 5-15V 12 I5 Optocoupler Input 5-15V 11 I6 Optocoupler Input 5-15V 10 I7 Optocoupler Input 5-15V 09 IGND Optocouplers ground 08 COMMON Common free wheeling diodes 33 O0 Output transistor up to 50V and 400 ma 21 O1 Output transistor up to 50V and 400 ma 02 O2 Output transistor up to 50V and 400 ma 22 O3 Output transistor up to 50V and 400 ma 03 O4 Output transistor up to 50V and 400 ma 23 O5 Output transistor up to 50V and 400 ma 04 O6 Output transistor up to 50V and 400 ma 24 O7 Output transistor up to 50V and 400 ma 05 R7 A Output relay D7 contact 30 R7 B Output relay D7 contact 31 R7 C Output relay D7 contact 32 R6 A Output relay D6 contact 26 R6 B Output relay D6 contact 25 R6 C Output relay D6 contact 27 February 2003 page 13 / 16
14 Application Tips If you don't need flow control but need to power your device attached to the serial port (max. 5-10mA), you can use the RTS pin (pin 8 on the Cannon 9 connector of the converter). To have about +8V available on this pin, activate "&R: RS485/RS422 control". If you want to allow only a certain single remote device to communicate with the converter, enter its (remote) IP address in "In IP Setup - W: Address" and set its mask "N" to Learn to use the Network Virtual Terminal in your application. It is an easy and transparent way of transferring control information, standardized in RFC2217. If you use the conversion to RS485, set the configuration to &R2 or &R3 and don't forget to turn HALF DUPLEX on using &H1. Take advantage of our configuration and application software, it is free. Up-to-date versions of our control subroutines are available at our website, or we can them to you if you prefer. Free Application Software Take advantage of the supplied free SW, either for configuring or for ideas for writing drivers. Detailed description of the free subroutines, TEA encryption, and our NVT implementation is available in the "Programming Ethernet Applications" document. The depicted Web51 Charon demo terminal is a simple terminal for transferring data through the Windows network layer. The program is available with its source code - Visual Basic 6. According to the checkboxes "DATA I/O pins", the program mixes a 6-byte control word that sets the parallel outputs into the data stream. It is possible to control, for example, a LED on the parallel output of the I/O Controller or the Charon I module. February 2003 page 14 / 16
15 Some of our related products RS232 - Ethernet Converter Industrial version of our RS232 converter for TCP/IP or UDP/IP protocols. RS485 conversion module is available. Configurable over UDP/IP or RS232. All serial parameters configurable ( Bd, 7-9 data bits, parity,...) Supports 9-bit transfer protocols Secure configuration over the Ethernet Support for an internal or external RS485 converter (protocol detection, converter addressing, HW echo, waiting for silence on half-duplex media, etc.) Support for proprietary protocols can be added Embedded RS232 - Ethernet Converter Module Embedded module, approx. 40x50 mm with 2x12 pins. Ethernet connection on one side, RS232 and 8 TTL inputs controllable over the network on the other side. Only the RJ45 connector with a built-in magnetic (supplied) for connecting a network TP cable is outside of the module. Continuously updated firmware available free of charge in the following versions: RS232 Ethernet Converter - described in this document SNMP controls up to 64 remote I/O ports Empty (raw) version - user programmable, contains the I/O Controller Lite The module price is about half of the converter price! Ethernet - serial Buffer 512 kb Buffer with 512 kb of FLASH memory for data received from the serial line. Data can be read out over the Ethernet using the TCP/IP protocol. If the buffer overflows, a warning is sent to the operator. Secure reading of data from the buffer warning when buffer is filling up (two levels corresponding to about 75% and 90% of capacity) or when a power outage occurs 512 kb of FLASH memory with space compression support Powerful remote configuration options, easy installation February 2003 page 15 / 16
16 Recommended literature and references Programming Ethernet Applications (21 pages) Detailed how-to for Ethernet application programming. Documented examples of the source codes supplied with our devices. Description of the NVT and the TEA algorithms. Charon I - datasheet (12 pages) Datasheet for the Charon I web51 based modules. Contains in particular the electrical parameters, connector descriptions, programming procedures, etc. Circuit diagram is available for download at our website. Detailed informations for every application (for example the RS232-Ethernet Converter) is not part of this datasheet. RS232 - Ethernet Converter - Physical description of the "boxed" converter. - Details and the SETUP description of the "RS232-Ethernet Converter" application available for the "Charon I" modules as well. WWW pages of the HW Group about final products: For professionals and developers: Web51 Project - Contacts and detailed information HW group (HW server) Rumunska 26/122 Prague Czech Republic - Europe Phone : Fax : February 2003 page 16 / 16
PortStore2 PL. RS-232 - Ethernet converter + serial buffer TCP/IP Server or Client/Server mode EN 600 298
PortStore2 PL RS-232 - Ethernet converter + serial buffer TCP/IP Server or Client/Server mode EN 600 298 strana 2 z 12 October 2007 page 2 www.hw-group.com Table of contents Table of contents... 2 Table
IP Relay 2x Relay controlled over Ethernet + RS-232 / Ethernet converter (Terminal server)
IP Relay 2x Relay controlled over Ethernet + RS-232 / Ethernet converter (Terminal server) EN 900 478a Shipment contents Complete shipment of the IP Relay contains following items: IP Relay in a metal
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
TRP-C31M MODBUS TCP to RTU/ASCII Gateway
TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
LS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Manual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
IP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
The Secrets of Flow Control in Serial Communication
in Serial Communication Casper Yang, Senior Product Manager [email protected] Although RS-232/422/485 serial communication is no longer considered to be high speed, flow control is still an important function
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
Serial over Ethernet Device Server. User s Manual
Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw [email protected] Serial over Ethernet
MODBUS TCP to RTU/ASCII Gateway
MODBUS TCP to RTU/ASCII Gateway Users Manual Model MODport-101, MODport-102, MODport-104 July 2011 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Advanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: [email protected] Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16
RS232 Serial TO Ethernet convert Module USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16 Jinan USR Technology Co., Ltd. works on LAN and WAN and wireless for MCU to Ethernet Solutions, Ethernet,
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
7.7 Ethernet Communication (AFPX-COM5)
7.7 Ethernet Communication (AFPX-COM5) 7.7.1 AFPX-COM5 Overview The communication cassette AFPX-COM5 has an Ethernet interface at the COM1 port and a 3-wire RS232C interface at the COM2 port. The Ethernet
Remote Serial over IP Introduction on serial connections via IP/Ethernet
Remote Serial over IP Introduction on serial connections via IP/Ethernet TABLE OF CONTENT TABLE OF CONTENT... I TABLE OF IMAGES... I INTRODUCTION... 1 Classic Style of Communication... 1 Ethernet and
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
EMS. EtherCAN CI. Ethernet/CAN Interface. User Manual THOMAS WÜNSCHE. Documentation for Ethernet/CAN interface EtherCAN CI version 2.1.
Documentation for Ethernet/CAN interface version 2.1. Document version: V3.0 Documentation date: June 16th, 2007 This documentation is not valid for version 2.0 and earlier versions. No part of this document
Operation Manual of EX-9132C-2. Serial to TCP/IP Converter
Operation Manual of EX-9132C-2 Serial to TCP/IP Converter Version 1.2.1 20th May 2013 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 6 Product Specifications
Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.
Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents
isco Connecting Routers Back to Back Through the AUX P
isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
RS-232/422/485, Power over Ethernet
IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware
LBNP16312. RS-232/485/422 serial device server. User manual
Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
NVT (Network Virtual Terminal) description
NVT (Network Virtual Terminal) description English version Czech version Communication with the TCP/IP device over the Ethernet network can be extended to more functions using NVT (Network Virtual Terminal)
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999
232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been
RS-232 Communications Using BobCAD-CAM. RS-232 Introduction
RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running
Cable Pinouts. SRP I/O Module
Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4
Portable BACnet /IP to MS/TP Router
Portable BACnet /IP to MS/TP Router Installation Instructions TL-BRTRP-0 Part No. 24-10414-2, Rev. F Issued April 2016 Refer to the QuickLIT website for the most up-to-date version of this document. Applications
1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking
POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
ILPH technical documentation Ethernet - serial interface e-ilph
ILPH technical documentation Ethernet - serial interface ABB Page 1 1SNB 002323 R2100 V1.1 1. Description... 3 2. Connection... 3 2.1. Power supply... 3 2.2. Ethernet Network... 4 2.3. Serial port... 4
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
Serial Over IP Ethernet Device Server
NETRS2321E NETRS2321EEU NETRS2321EGB Instruction Manual Serial Over IP Ethernet Device Server 1 Port RS-232/422/485 Serial over IP Ethernet Device Server Manual Revision:10/13/2010 For the most up-to-date
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Application Note. Terminal Server G6
MICROSENS GmbH & Co. KG Küferstr. 16 59067 Hamm/Germany Tel. +49 2381 9452-0 FAX +49 2381 9452-100 E-Mail [email protected] Web www.microsens.de Summary As of firmware version v10.6 MICROSENS Generation
Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions
Applications What are some of the applications for the Model 2120 Single Port Terminal Server? The Patton Single Port RS-232 Terminal Server provides the ability to bring virtually any RS-232 device onto
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
FBs-CM25/CM55/CBE. Ethernet Module. User s Manual
FBs-CM25/CM55/CBE Ethernet Module User s Manual Ver. 2.1 Fatek Automation Corp. 7/1/2004 1. Preface...2 2. Specification...2 2.1 Serial Communication Connector(FBS-CM25E/CM55E only)...2 2.2 Ethernet Serial
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
LTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION
RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction
OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R
OSBRiDGE 5XLi Configuration Manual Firmware 3.10R 1. Initial setup and configuration. OSBRiDGE 5XLi devices are configurable via WWW interface. Each device uses following default settings: IP Address:
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
FINS Gateway For OMRON PLCs
1 Purpose This Technical Note describes how to set up a remote collaboration. A remote collaboration consists in configuring, programming or monitoring a PLC from a remote location, without the need of
INTRODUCTION FEATURES OF THE ICM
INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you
RS232/485 TCP/IP converter TPC2RS. Ver. 01A- GB
RS232/485 TCP/IP converter TPC2RS Ver. 01A- GB ----------- TCP2RS -------------- User s manual -------------------- page 2/43 1: INTRODUCTION...5 1.1 NETWORK PROTOCOLS...5 1.1.1 Packing Algorithms...6
TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module
Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually
WHQL Certification Approval...2 User Interface...3 128K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5
0 INDEX WHQL Certification Approval...2 User Interface...3 128K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5 1.0 Introduction 6 2.0 Features.. 6 3.0 Hardware Guide... 7 3.1 System
Cable Specifications and Information
APPENDIX A This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG224 voice gateway. To order cables from Cisco, see the Obtaining Technical
WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4
INDEX WHQL Certification Approval...2 User Interface....3 SUNIX s COMLab..4 1.0 Introduction...5 2.0 Specification..5 2.1 Features 2.2 Universal Serial PCI Card 2.3 RS-232 Specification 2.4 Low Profile
DK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR
AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
EZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
LotWan Appliance User Guide USER GUIDE
LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document
VSCOM USB PRO Series Industrial I/O Adapters
VSCOM USB PRO Series Industrial I/O Adapters 1.Introduction The VSCOM USB PRO Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS-232/422/485 serial devices.
Cabling Guide for Console and AUX Ports
Cabling Guide for Console and AUX Ports Contents Introduction Prerequisites Requirements Components Used Conventions Table of Routers with Console and AUX Ports Console Port Settings for Terminal Connection
LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and
XPort Device Server User Guide
XPort Device Server User Guide Part Number 900-270 Revision P November 2014 Intellectual Property 2014 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced
RS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci
Firmware Loader User Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876
UDS10 UDS100 User Guide
UDS10 UDS100 User Guide Part Number 900-360 Revision A June 2004 Copyright & Trademark 2004, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any
How To Run An Nport I5000A Device Server
NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
EZL-50L User s Manual
EZL-50L User s Manual Version 1.1 Sollae Systems - 1 - To all residents of the European Union Important environmental information about this product This symbol on this unit or the package indicates that
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
NPort DE-311 Hardware Installation Guide
NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation
Wifi Web Server Module w TF Socket User s Guide
Wifi Web Server Module w TF Socket User s Guide 2004-2010 Sure Electronics Inc. MB-CM14117_Ver1.0 WIFI WEB SERVER MODULE W TF SOCKET USER S GUIDE Table of Contents Chapter 1. Overview...1 1.1 Overview...
Operation Manual of EX9132C-RS485. Serial to TCP/IP Converter
Operation Manual of EX9132C-RS485 Serial to TCP/IP Converter Version 1.0 27th May 2014 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Product Features 7 Product Specifications
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
IP WatchDog Lite Dual monitor of Ethernet devices with automatic reset function
IP WatchDog Lite Dual monitor of Ethernet devices with automatic reset function EN 600 218 Shipment contents Complete shipment of IP Watchdog Lite contains following items: IP Watchdog Lite in a plastic
SenseLink TM. End-Point Controller. Addendum
SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink